TY - JOUR ID - TI - Spot Welding of Galvanized Steel ASTM A653 Using Oxygen Free High Conductivity Copper Interlayer اللحام النقطي للفولاذ الكاربوني (ASTM A653) باستخدام نحاس عالي النقاوة كطبقة وسطية AU - Mohammed Hillan Sar PY - 2016 VL - 14 IS - 1 SP - 63 EP - 72 JO - journal of kerbala university مجلة جامعة كربلاء SN - 18130410 AB - The effect of spot welding parameters (Current and Applied Load) are studied in welding of galvanized steel specimens. Three values of current 9600, 11000 and 12300 AMP and load of 350, 400, 450 kg are used. The results indicate that the shear force improve with increasing the current and decreasing the load. The optimum shear force is achieved with current of 12300 AMP and load of 350 kg. Those parameters is used to weld steel (with and without galvanize layer) using the OFHC copper as interlayer with different thickness (0.1, 0.2 and 0.3mm). The results show that OFHC as interlayer reduce the shear force.

تم دراسة تأثير متغيرات لحام النقطة (التيار وحمل مسلط ) على عينات من الفولاذ المغلون . اختيرت ثلاث قيم من التيار ( 9600, 11000، 12300 أمبير) وثلاث قيم من حمل مسلط ( 350 , 400 ، 450 كغم ) للحام العينات . اظهرت النتائج ازدياد قوة القص بزيادة التيار وصولا الى 12300 امبير وحملا مسلطاً عند 350 كغم. استخدمت هذه المتغيرات للحام العينات المغلونة وغير المغلونة ( بعد ازالة طبقة الزنك) باستعمال طبقة رقيقة من النحاس عالي النقاوة كمعدن حشو وباسماك (0.1، 0.2 ، 0.3 ملم ). بينت النتائج ان استخدام معدن الحشو ساعد على خفض قوة القص. ER -