TY - JOUR ID - TI - Joined Liquid Ion Exchange with Cloud Point Extraction Methods for Separation and Determination of Cr(VI), Mn(VII AU - Dr. Shawket Kadhim Jawad PY - 2016 VL - 2 IS - 1 SP - 1 EP - 17 JO - JOURNAL OF KUFA FOR CHEMICAL SCIENCES مجلة الكوفة لعلوم الكيمياء SN - 20772351 AB - Sensitive and selective extraction method used for separation, preconcentration and spectrophotometric determination of Cr(VI) as Cr2O7= and Mn(VII) as MnO4- from HCl media by used Janus green B after formation ion pair association complex, studies the optimum condition for extraction demonstrated 0.1M and 0.05M of HCl suitable for extraction efficiency of Cr(VI) and Mn(VII) respectively , in presence 50µg Mn(VII) or 20µg of Cr(VI). with 0.8mL 1% TritonX-100 for extraction ion pair association of Cr(VI) as well as 0.5mL for Mn(VII) and 95°C suitable for formation CPL and extraction ion pair complex for both metal ions ,with 15 min. of heating time for both metal ions. Then study effect of interferences and electrolyte presence. This method applied for spectrophotometric determination of Cr(VI) and Mn(VII) in different samples. The wave length for maximum absorbance of ion pair complex extracted was λmax=560 nm for Mn(VII) and 603nm for Cr(VI) complexes.

تم فصل وإغناء وإستخلاص أيوني Cr(VI) على هيئة Cr2O7= و Mn(VII) على هيئة MnO4- من وسط حامض HCl وباستخدام صبغة Janus green B لتكوين معقد الترابط الأيوني، دراسة الظروف المثلى للأستخلاص أظهرت التركيز الامثل لحامض الهيدروكلويك 0.1M HCl و 0.05M على التوالي وبوجود 50µg Mn(VII) أو 20µg of Cr(VI) وبوجود 0.8mL 1% TritonX-100 لاستخلاص Cr(VI) و 0.5mL لاستخلاص Mn(VII) وكانت 95°C هي الدرجة الحرارية الملائمة وبزمن تسخين 15 min. لكلا الأيونين. أضافة الى دراسة تأثير المتداخلات والأملاح الألكتروليتية. واستخدمت هذه الطريقة لتقدير كلا الأيونين في نماذج مختلفة. وكان الطول الموجي لأعظم إمتصاص لمعقد الترابط الأيوني المستخلص λmax=560 nm لمعقد المنغنيز و 603nm لمعقد الكروم. ER -