@Article{, title={EVALUATION THE PRECISION OF " DOCTORE TEST" FOR MERCAPTANS DETECTION IN PETROLEUM PRODUCTS BY SULPHIDE ION-SELECTIVE ELECTRODE تقييم طريقة (فحص الدكتور) لتقدير المركبتانات في المنتوجات النفطية باستعمال قطب الكبريتيد الانتقائي.}, author={TAHSEEN A. ZAIDAN تحسين علي زيدان}, journal={Journal of university of Anbar for Pure science مجلة جامعة الانبار للعلوم الصرفة}, volume={1}, number={3}, pages={41-44}, year={2007}, abstract={Mercaptan sulphur in petroleum products ( Motor fuel, kerosene, aviation fuel ,….etc) were detected with standard test method of British Institute of Petroleum ( IP) that marked by the number IP-30 . The detection of this method was qualitatively and the precision has not been established. In this research a précised results were tabulated for the IP-30 test method, using sulphide ion selective electrode. A comparable results of quantitative value for mercaptans of IP-30 test method now are available.

الخلاصة:والمطابقة لطريقة (IP- تعد طريقة "فحص الدكتور" المعروفة بطريقة المعهد البريطاني للنفط ( 30مقياسًا تحليليُا نوعيًا سريعًا للكشف عن تواجد (ASTM-D484- القياسي الأمريكي للفحص والمواد ( 52. RSH بعض مركبات الكبريت المهمة في المنتوجات النفطية وخاصة المركبتانتم في هذا البحث توسيع مدى الفائدة من استخدام هذه الطريقة وتحويلها من طريقة تحليلية نوعيةإلى طريقة تحليلية كمية، باستخدام قطب الكبريتيد الانتقائي لتقدير المركبتان في نماذج منتوجات نفطيةأعطت كشفًا تحليليًا نوعيًا عن المركبتان. لقد تم مطابقة قيم المركبتان التي تعطي كشوفًا موجبة أو سالبةمع تراكيز محسوبة من المركبتان باستخدام قطب الكبريتيد الانتقائي، لذا يمكن اعتبار طريقة فحص الدكتورطريقة تحليلية كمية سريعة لتعيين المركبتان في مختبرات السيطرة النوعية في مصافي النفط.} }