TY - JOUR ID - TI - Treatment of Industrial Waste Water using Reverse Osmosis Technique AU - Rasha H. Salman AU - Sama M. Abdullah AU - Nada S.Ahmedzeki PY - 2009 VL - 15 IS - 4 SP - 4356 EP - 4363 JO - Journal of Engineering مجلة الهندسة SN - 17264073 25203339 AB - Reverse osmosis technique was used for the treatment of industrial waste water. Ions like calcium, magnesium, sodium, sulfate, and nitrate were found in the waste water of the General Company of Vegetable Oil with high concentrations which must be treated for reuse. Feed water containing the above mentioned ions was fed to the RO unit at feed flow rates (0.4 and 0.8 lit/min) and different operating pressure (2-4bar) .It is concluded that increasing operating pressure and feed flow rate improved the separation by a decrease in the concentration of ions in the product. High rejection was obtained for all ions present in feed water, ranging from (63.8-97.6%). Rejection of TDS was 87% when the concentration of TDS was reduced from 1192 to 154.94 ppm.

تقنية التنافذ العكسي أستخدمت لمعاملة المياة الصناعية . أيونات الكالسيوم و المغنيسيوم و الصوديوم و االكبريتات و النترات توجد في المياه الصناعية المطروحة من الشركة العامة للزيوت النباتية وبتراكيز عالية يجب أن تعالج لغرض اعادة استعمالها. المياه الحاوية على الأيونات أعلاه تدخل الى وحدة المعالجة بالتناضح العكسي بمعدل جريان (0.4 و0.8 لتر/دقيقة) وتحت ضغط تشغيلي (2-4 بار).لقد استنتج ان زيادة الضغط ومعدل الجريان ادى الى تحسين عملية الفصل بتقليل تركيز الايونات في الماء الناتج. أزالة عالية لكل الأيونات الموجودة في المياه الداخلة تمت بمعدل (63.8-97.6 %). ومعدل أزالة لكمية المواد الصلبة الكلية الذائبة كان (87%) عندما أنخفضت هذه الكمية من 1192 الى 154.94جزء بالمليون. ER -