TY - JOUR ID - TI - STUDY THE PERFORMANCE OF SULFAMIC ACID AND CITRIC ACID IN REMOVAL THE SCALE DEPOSITED ON THE DURA REFINERY HEAT EXCHANGE PIPING SYSTEM دراسة ادائية حامضي السلفامك والستريك في ازالة التكلسات المترسبة على انابيب اجهزة المبادلات الحرارية في مصفى الدورة AU - Najwa S. Majeed PY - 2010 VL - 16 IS - 1 SP - 4478 EP - 4487 JO - Journal of Engineering مجلة الهندسة SN - 17264073 25203339 AB - This paper describes an experimental study on the performance of sulfamic acid and citric acid in scale removal of Dura refinery heat exchange piping systems.Experiments were carried out using sulfamic acid and citric acid inhibited by hexamine as cleaning solutions at different time, temperature and concentrations. A dynamic flow system was designed for this state. A scaled copper alloy pipes from the main hot water lines (heat exchanger) was used. Hexamine was used as corrosion inhibitor.The research involved a study of effect of the time ,temperature and acid concentration of each acid on the scale removal, and a comparison of the performance of the two used acids were investigated.

يهدف البحث الى دراسة عملية لادائية حامضي السلفامك و الستريك في ازالة التكلسات المترسبة على انابيب المبادلات الحرارية المستخدمة في مصفى الدورة .اجريت تجارب عملية استخدم فيها حامضي السلفامك والستريك المثبطة بمادة الهكسامين كمواد كيمياوية مزيلة للتكلسات عند ازمان مختلفة ودرجات حرارة مختلفةوتراكيز متعددة.صممت منظومة جريانية لهذا الغرض استخدمت فيها قطع من انابيب مأخوذة من اجهزة المبادلات الحرارية المستخدمة في مصفى الدورة.لقد تضمن البحث دراسة تاثير زمن المعالجة ودرجة الحرارة وتركيز الحوامض المستخدمة واجراء مقارنة لادائية كل من الحامضين المستخدمين لازالة تكلسات الانابيب المستخدمة في المبادلات الحرارية في مصفى الدورة. ER -