TY - JOUR ID - TI - Determination of Bio-decay Coefficient of Disposed Activated Sludge from Wastewater Treatment Plant in Medical Assembly of Mosul City إيجاد معامل الانحلال الحيوي (kd) للحمأة المنبوذة من محطة معالجة المياه المطروحة في مجمع المستشفيات لمدينة الموصل AU - Ahmed Y. Shehab احمد ياسين شهاب PY - 2011 VL - 19 IS - 2 SP - 28 EP - 37 JO - AL-Rafidain Engineering Journal (AREJ) مجلة هندسة الرافدين SN - 18130526 22201270 AB - AbstractThis research, has dealt with determination of bio-decay coefficient of activated sludge disposed from wastewater treatment plant of medical assembly in Mosul city. four bench scale reactors were used of 2.25 liter capacity for each as aerobic digestion units. Throughout the operation period which lasted for a month temperature was controlled and it was (15, 20, 25, 30) ċ in the first second third and fourth reactor respectively, the bio-decay coefficients was found as (kd15=0.02, kd20=0.03, kd25=0.04, kd30=0.05) d-1 , while the temperature constant (θ) was (1.059). Also the results showed that the required periods for aerobic digestion process to reduce 50% of biomass concentration in the reactors at digestion temperature (15, 20, 25, 30) ċ were (17, 7, 5, 4) days respectively.

الخلاصةتناول البحث دراسة معامل الانحلال الحيوي للحمأة المطرحة من محطة معالجة المياه المطروحة في مجمع المستشفيات لمدينة الموصل، أُعدت أربعة أحواض مختبرية بسعة 2.25 لتر للحوض وجُهزت لتعمل كوحدات هضم هوائية. وفي أثناء فترة تشغيلية استمرت لمدة شهر تمت فيها السيطرة على درجة حرارة الهضم بحيث كانت ċ(30, 25, 20, 15) في الحوض الأول والثاني والثالث والرابع على التوالي، أُحتسب معامل الانحلال الحيوي للحمأة وكان d-1(kd15=0.02, kd20=0.03, kd25=0.04, kd30=0.05). كما تم إيجاد الثابت الحراري لمعامل الانحلال الحيوي (θ) وقُدرة قيمته بـ (1.059). فضلا عن ذلك أثبتت نتائج الدراسة بأنه لخفض %50 من تركيز الكتلة الحية في الأحواض الاختبارية عند درجة حرارة هضم تساوي ċ(30, 25, 20, 15) تطلب استمرار عملية الهضم الهوائي لمدة(3, 4, 7, 17) يوم على التوالي. ER -