TY - JOUR ID - TI - Experimental Investigation on the Effect of the Use of Steel Wire Meshes on Shear Transfer Strength of Reinforced Concrete Push-Off Specimens دراسة عملية لتاثير الشبكات الحديدية على انتقال القص في الخرسانة المسلحة AU - Nibras N. Al-Chalabi نبراس نزار PY - 2011 VL - 15 IS - 1 SP - 205 EP - 215 JO - Journal of Engineering and Sustainable Development (JEASD) مجلة الهندسة والتنمية المستدامة SN - 25200917 25200925 AB - Using push-off specimens with shear plan length of 200mm and depth of 100mm, the influence of the addition of relatively widely spaced layers of steel wire meshes on shear transfer strength of reinforced concrete was experimentally investigated in this study. Eleven push-off specimens were fabricated and were divided into three groups depending on the number of layers of wire meshes crossing the shear plan. The other studied parameters were the shear parameter of the conventional stirrups (ρfy) and the angle of the plan of the steel wire mesh layers to shear plan of the push-off specimens.Using push-off specimens with shear plan length of 200mm and depth of 100mm, the influence of the addition of relatively widely spaced layers of steel wire meshes on shear transfer strength of reinforced concrete was experimentally investigated in this study. Eleven push-off specimens were fabricated and were divided into three groups depending on the number of layers of wire meshes crossing the shear plan. The other studied parameters were the shear parameter of the conventional stirrups and the angle of the plan of the steel wire mesh layers to shear plan of the push-off specimens.The test results showed that the use of relatively widely spaced (about 40mm) steel wire meshes has only trivial effect on shear transfer strength of reinforced concrete, where the percentage increase in shear transfer strength was about 8% in best cases. While using steel wire meshes in combination with conventional shear reinforcement (stirrups) gave better results, the percentage increase was about 13% compared to specimens reinforced with the same amount of stirrups but without steel wire meshes.

إستخدمت في هذا البحث نماذج خاصة (Push-off) ذات مستوى قص بطول 200 ملم وعمق 100ملم لدراسة تأثير إضافة طبقات متباعدة نسبياً من مشبكات أسلاك حديدية على مقاومة انتقال القص في الخرسانة المسلحة. تم استخدام 11 نموذجاً قسمت الى ثلاثة مجاميع إعتماداً على عدد طبقات مشبكات الأسلاك الحديدية. العوامل الأخرى التي تم دراستها هي مقدار معامل القص لحديد القص التقليدي (الأترية) بالإضافة الى زاوية مشبكات الأسلاك الحديدية مع مستوى القص للنماذج.أظهرت النتائج أن استخدام طبقات متباعده نسبياً (حوالي 40 ملم) من مشبكات أسلاك حديدية له تأثير متواضع على مقاومة انتقال القص للخرسانة المسلحة, حيث كانت نسبة الزيادة في مقاومة انتقال القص حوالي 8% في أفضل الحالات. بينما أظهرت النتائج أن استخدام هذه المشبكات مع حديد القص التقليدي (الأترية) يعطي نتائج أفضل, حيث أن نسبة الزيادة بلغت 13% مقارنة مع نماذج مسلحة بنفس الكمية من الأترية ولكن بدون مشبكات الأسلاك الحديدية. ER -