@Article{, title={Indirect Spectrophotometric Method for Determination of Bromhexine-Hydrochloride in Pharmaceutical Preparations طريقه طيفيه غير مباشره لتقدير البرومهكسين – هيدروكلورايد في مستحضراته الصيدلانيه}, author={Shilan A. Omer شيلان عمر and Nabeel S. Othman نبيل صبيح عثمان}, journal={Rafidain journal of science مجلة علوم الرافدين}, volume={19}, number={2 E}, pages={16-27}, year={2008}, abstract={A sensitive indirect spectrophotometric method is developed for the determination of bromhexine-HCl in pure and dosage forms. The method is based on the oxidation of bromhexine-HCl with iron(III) in acidic medium, then reaction of iron(II) with 1,10-phenathroline to produce a ferroin complex which is water-soluble, stable, and has a maximum absorption at 510 nm against the reagent blank with a molar absorptivity of 3.51×104 l.mol-1.cm-1. Beer’s law is valid over the concentration range of 10 to 220g bromhexine-HCl in a final volume of 25 ml. The proposed method has been applied successfully to determine bromhexine-HCl in different pharmaceutical preparations.

تم تطوير طريقة طيفية غير مباشره حساسة لتقدير البرومهكسين بشكله الحر وفي مستحضراته الصيدلانية. تعتمد الطريقة على أكسدة البرومهكسين بوساطة الحديد الثلاثي في الوسط ألحامضي ومفاعله الحديد الثنائي الناتج مع الكاشف 10،1-فيناثرولين لينتج معقد الفيرون الذي يكون ذائباُ في الماء ومستقراُ ويعطي أعلى شدة امتصاص عند الطول الموجي 510 نانوميتر مقابل المحلول الصوري، وكانت قيمة الامتصاصية المولارية 3.507×104 مول.لتر-1.سم-1. وينطبيق قانون بير في مدى التركيز من 10 إلى 220 مايكروغرام برومهكسين في حجم نهائي 25 مل. تم تطبيق الطريقة بنجاح في تقدير البرومهكسين في مستحضراته الصيدلانية المختلفة.} }