Table of content

Al-Qadisiyah Journal for Engineering Sciences

مجلة القادسية للعلوم الهندسية

ISSN: 19984456
Publisher: Al-Qadisiyah University
Faculty: Engineering
Language: Arabic and English

This journal is Open Access

About

Al-Qadisiyah Journal for Engineering Sciences (QJES), ISSN: 1998-4456, was established in 2008. The Journal, in its current form, is intended to contribute to the state of the art in all fields of engineering research.
The Journal is a peer-reviewed journal and is published by the Faculty of Engineering, University of Al-Qadisiyah. The journal is now published Quarterly(March, June, September and December).

Loading...
Contact info

College of Engineering - Al-Qadisiyah university - Al-Diwaniya province - Rep. of Iraq box ( 1759 ) - fax (00964 (0) 36 652663) - Tel: +964(780)1432941
E-mail: engjou@qu.edu.iq

Table of content: 2011 volume:4 issue:1

Article
EFFECT OF ALUMINA PARTICLES ON THE MECHANICAL PROPERTIES OF DISCONTINUOUS GLASS FIBER REINFORCED UNSATURATED POLYESTER COMPOSITES
تأثير إضافة دقائق الألومينا على الخواص الميكانيكية للمادة المركبة ذات الأساس من البولي أستر غير المشبع المقواة بألياف الزجاج غير المستمرة

Loading...
Loading...
Abstract

he polyester matrix composites reinforced with short glass fiber and reinforced with glass fiber and Al2O3 particles with different weight fractions (3, 5, and 7 wt% Al2O3) were prepared and then the mechanical testing (bending, impact, and hardness) were measured. The results showed the mechanical properties improve with increasing weight fraction. The impact energy of hybrid composite is better than compared with the composite reinforced with glass fiber alone at same weight fractions. تم تصنيع مادة مركبة ذات أساس بوليمري (بولي أستر) مقواة بألياف زجاجية مقطعة نوع (E-glass) ، ونماذج أخرى من المادة ذات الأساس البوليمري مقواة بألياف الزجاج ودقائق الألومينا معاً وبثلاث كسور وزنية مختلفة (3, 5, 7 % wt). وتم إجراء فحوصات ميكانيكية للعينات مثل فحص الصدمة والصلادة والانحناء ، ومن النتائج تبين أن الخواص الميكانيكية تتحسن مع زيادة الكسر الوزني. إن الطاقة الممتصة للكسر أعطت أفضل النتائج للعينات المقواة بألياف الزجاج ودقائق الألومينا مقارنة مع العينات المقواة بألياف الزجاج فقط وبنفس الكسور الوزنية.


Article
REINFORCING BY HYBRID FIBERS AND ITS EFFECT ON THERMAL CONDUCTING FOR POLYMERIC COMPOSITE MATERIAL
التسليح بألياف هجينة وتأثيرها على التوصيل الحراري لمادة متراكبة بولميرية

Loading...
Loading...
Abstract

The aims of this study is to investigation the effect of reinforcing with hybrid fibers included natural palms fibers and carbon fibers on thermal behavior of araldite resin(AY103) . This resin was reinforced with natural palms fibers is studied and compared it with another material reinforced by carbon fibers(°0)with (1.75g/cm3) density ,and then these two types of fibers combined together in same matrix to make a hybrid composite material and also calculated the range of it's thermal conductivity coefficient .Fourier equation used to calculate the thermal conductivity coefficient(k) to obtained composite material and. the results obtained from thermal conductivity test show that the thermal conducting value of natural palms fibers higher than reinforcing with carbon and hybrid fibers . تهدف هذه الدراسة إلى البحث في تأثير التسليح بألياف هجينة مكونة من ألياف النخيل الطبيعية وألياف الكاربون على السلوك الحراري لراتنج الإرلدايت(AY103) . تم تسليح الراتنج بألياف النخيل الطبيعية ومقارنتها مع مادة أُخرى مقواة بألياف الكاربون أحادية الإتجاه(°0) ذات كثافة سطحية (1.75gcm3) ، بعدها تم دمج هذين النوعين من الألياف في أرضية واحدة لتكوين مادة متراكبة هجينة والتي تم حساب معامل التوصيل الحراري لها أيضاً. إستخدمت معادلة فورير لحساب معامل التوصيل الحراري(k) للمادة المتراكبة الناتجة. لقد أظهرت النتائج التي تم الحصول عليها من إختبار الموصلية الحرارية إن قيمة التوصيل الحراري لألياف النخيل الطبيعية هو أعلى منه في حالة التسليح بألياف الكاربون والألياف الهجينة .


Article
EFFECT OF REINFORCING BY FIBERS ON THERMAL CONDUCTIVITY AND MECHANICAL PROPERTIES OF THERMOSETTING RESINS
تأثير التقوية بالألياف على الموصلية الحرارية والخواص الميكانيكية للراتنجات المتصلبة بالحرارة

Loading...
Loading...
Abstract

The objective of this research is to study the effect of reinforcement by carbon fibers as woven roving (°90-°0) with density (1.75gcm3)on thermal conductivity for unsaturated polyester resin after reinforcing it by different percentage of fibers (20%, 40%,60%) and we used Fourier equation to calculate the thermal conductivity coefficient (k) . Also the mechanical properties of this resin was calculated with the same reinforcing percentage of fibers and these properties included : impact strength , tensile strength , compression strength , flexural strength , and hardness . The results show that improvement in thermal and mechanical properties after reinforced by fibers , and these properties will rise as increased in reinforcement percentage . إن الهدف من هذا البحث هو دراسة تأثير التقوية بألياف الكاربون بشكل ظفائر محاكة ثنائية الإتجاه (°0-°90) ذات كثافة سطحية (1.75gcm3) على الموصلية الحرارية لراتنج البولي أستر غير المشبع بعد تقويته بنسب وزنية مختلفة من هذه الألياف (%60, %40, %20) حيث إستُخدمت معادلة فورير لحساب التغير في قيمة معامل التوصيل الحراري (k) . إضافة إلى ذلك فقد تم حساب التغير في قيم الخواص الميكانيكية لهذا الراتنج بنفس النسب الوزنية المذكورة أعلاه وقد شملت هذه الخواص كل من مقاومة الصدمة ، مقاومة الشد ، مقاومة الإنثناء ، مقاومة الإنضغاط ، والصلادة . لقد أظهرت النتائج تحسن الموصلية الحرارية والخواص الميكانيكية بعد التقوية بالألياف ، وترتفع القيمة الخواص المذكورة بزيادة نسبة التقوية .


Article
BEHAVIOR 0F HIGH STRENGTH CONCRETE BEAMS USING RISEN EPOXY
تصرف الجسور الخرسانية عالية المقاومة باستخدام ايبوكسي الراتنج

Loading...
Loading...
Abstract

Reinforced concrete beams for high-strength concrete often exhibit structural and nonstructural cracking due to variety steel reinforcement. Four reinforced concrete beams with dimensions of (120*230*2550)mm were investigated. Beams (1&2) have tensile steel ratio (0.0099), while beams (3&4) have tensile steel ratio (0.018). Deflections were measured at first third, second third and mid span for original repaired beams using dial gauges with accuracy 0.01 mm. The repair strength achieved for risen epoxy injection high-strength reinforced concrete beams was shown similar that original beams, but a little deference. The failure load for repaired beams higher than original beams.العتبات الخرسانية المسلحة عالية المقاومة ترسم تشققات إنشائية وغير إنشائية تبعا لتنوع حديد التسليح.أربع عتبات خرسانية مسلحة بأبعاد (120*230*2550 ملم) تم فحصها.العتبات (1 و 2) تمتلك نسبة حديد تسليح في منطقة الشد (0,0099) بينما العتبات (3 و 4) نسبة حديد التسليح في منطقة الشد (0,018). الانحرافات التي قيست في الثلث الأول والثلث الثاني ومنتصف العتبات الأصلية والمصلحة باستخدام مقاييس بدقة 0,01 ملم.مقاومة التصليح لايبوكسي الراتنج المحقون للعتبات الخرسانية المسلحة نفس مقاومة العتبات الأصلية لكن باختلاف قليل.حمل الفشل للعتبات المصلحة اكبر من العتبات الأصلية.


Article
PRESSURE DROP CONSTRAINTS IN SLUDGE DOUBLE-PIPE HEAT EXCHANGER DESIGN
محددات فرق الضغط في تصميم مبادلات الحمأة الحرارية نوع الأنبوب المزدوج

Loading...
Loading...
Abstract

Recent years have witnessed a rapid development in the understanding of heat exchangers design. Those developments have justified the use of a global minimum allowable temperature approach under which the heat transfer area of the heat exchanger is minimized. Values of the allowable pressure drops of streams of exchangers are specified to calculate film heat-transfer coefficients of streams and heat-transfer area. By coupling this with the understanding of what dictates the energy consumption, it is possible to determine the trade-off between the heat exchanger capital cost and energy cost prior to design work. Pressure drop is an important issue in the design of a heat exchanger. Pumps and (or) compressors must be installed to overcome pressure losses when streams flow through heat exchangers. The total cost for a system of pumps and compressors consists of the purchase cost of equipments and the electricity cost to run these equipments. This cost could occupy a significant part of the overall cost for a heat exchanger. Therefore, the pressure drop aspect should be considered together with the costs of heat exchanger area. This paper demonstrates how pressure drop is considered in the context of a sludge double-pipe heat exchanger design. A relationship between heat transfer coefficient and heat exchanger pressure drop was determined and its capital cost implications were assessed. شهدت السنوات الأخيرة تطور سريع في تصاميم المبادلات الحرارية. تميزت معظمها باستخدامها مفهوم أدنى فرق في درجات الحرارة للحصول على اقل مساحة انتقال حراري. وطبقا لتلك الطريقة يتم تحديد قيم فرق الضغط المقبول لحساب معامل انتقال الحرارة ومساحة الانتقال الحراري من خلال ربط هذه الطريقة مع أسلوب حساب استهلاك الطاقة في المبادلات الحرارية ويمكن إجراء المفاضلة بين كلفة المبادل الحراري وكلفة الطاقة اللازمة لتشغيله قبل مرحلة التصاميم التفصيلية. وحيث أن فرق الضغط في المبادلات الحرارية ينعكس على كلف ملموسة في المبادلات الحرارية تتمثل بكلف المضخات والدافعات وكلف الطاقة اللازمة لتشغيل تلك المضخات والدافعات، فان دراسة تلك الكلف نسبة إلى كلفة المبادل الحراري تعتبر أمر ضروري ومهم. يستعرض هذا البحث كيفية تضمين فرق الضغط في مبادلات الأنبوب المزدوج المستخدم لتسخين الحمأة في أحواض الهضم ضمن مرحلة التصميم من خلال إيجاد علاقة بين معامل انتقال الحرارة وفرق الضغط وتقييم انعكاس ذلك على الكلفة المثالية للمبادل الحراري.


Article
TEMPERATURE CONTROL OF HIGH POWER MICROPROCESSOR
السيطرة على درجة الحرارة للمعدات الالكترونية ذي القدرة العالية

Loading...
Loading...
Abstract

Active control of the die-level temperature is desirable during production testing of high power microprocessors, so as to ensure accurate performance classification. The analysis in this research demonstrates fundamentals limits of temperature control for typical devices under test conditions. These limits are identified for specified control power to die power ratios. The effects of test sequence deign and device package design on the temperature control limits are also examined. The theory developed can be applied to any thermal control problem where a conductive medium separates the control source from the location where control is desired. As a dimensional example, when the die power density (Qd =10 W/cm2 ) and frequency of the die power variation ( =10 HZ) with ( = 4K ) , the required control power density ( Qc =63 W/cm2 ) . This performance is much better than for ideal temperature control where the control magnitude was found to be (173 W/cm2 ) with no change with the convective heat transfer coefficient f t when it varies from 500 W/m2.K to 2000 W/m2.K.السيطرة على درجة حرارة مادة المعالج الالكتروني مهمة جدا" خلال عمليات الإنتاج والفحص للتحقق من دقة الأداء. التحليل الرياضي في هذا البحث، يستخدم أساسيات انتقال الحرارة لسيطرة على درجة حرارة معدات الكترونية نموذجية تحت الفحص. كذلك تم دراسة تأثير عمليات التصميم والفحص على حدود السيطرة على درجة حرارة المعالج الالكتروني. أيضا"، تم توضيح عملية السيطرة بمثال نموذجي لمعالج الكتروني ذو قدرة Qd=100 W/cm2 وتردد 10 Hz حيث وجد أن القدرة اللازمة للسيطرة هي Qc=63 W/cm2 وهذا الأداء أفضل من نضيره في عمليات السيطرة العادية حيث يحتاج المعالج الألكتروني الى Qc=173W/cm2 مع تبات معامل انتقال الحرارة بالحمل hc ولمعدلات من 500 W/m2.K إلى 2000 W/m2.K.


Article
THREE DIMENSIONAL FINITE ELEMENT SIMULATION OF COLD FLAT ROLLING
تمثيل ثلاثي الإبعاد لعملية الدرفلة على البارد باستخدام طريقة العناصر المحددة

Loading...
Loading...
Abstract

In this paper the finite element analysis of the cold flat rolling is well presented to predict the roll force, slab velocity at entry and exit, temperature rise in the slab during cold rolling, strain and stress distribution around the slab. The effects of friction coefficient and yield stress of slab material on rolling are assumed. It is found that maximum force occurs at the position of neutral point between entry and exit, also it is found that the velocity of slab at exit is larger than that at entry. The finite element results of temperature distribution around the slab predict that there is a considerable rise in slab temperature. في هذا البحث تم تحليل عملية الدرفلة على البارد باستخدام طريقة العناصر المحددة وذلك لغرض تخمين القوة المؤثرة على الدرفيل، سرعة الكتلة المدرفلة في بداية الدخول والخروج من الدرافيل، الارتفاع في درجة حرارة الكتلة نتيجة التشوه الدن، واخيراً توزيع الانفعال والاجهاد المؤثرة خلال عملية الدرفلة. تم الأخذ بنظر الاعتبار معامل الاحتكاك واجهاد الخضوع للمادة المدرفلة. النتائج المستحصلة توضح ان أقصى قيمة للقوة المؤثرة على الدرافيل تكون في نقطة التعادل والتي تقع في مكان ما على سطح التماس بين منطقة الدخول والخروج كذلك توضح النتائج ان سرعة الكتلة المدرفلة تكون اكبر في منطقة الخروج عن تلك السرعة في منطقة الدخول. ان النتائج المستحصلة بطريقة العناصر المحددة توضح ان هناك ارتفاع في درجة حرارة الكتلة المدرفلة يجب ان تؤخذ بنظر الاعتبار.


Article
EXPERIMENTAL STUDY OF R.C. CORNER DETAILS
دراسة عملية لتفاصيل الوصلات الخرسانية المسلحة

Loading...
Loading...
Abstract

This investigation presents an experimental study of strength and behaviour of various types of reinforcement details in concrete corner subjected to bending moment tended to open the angle. Ten specimens with various arrangements of reinforcement in the corner region are tested to study the effect of reinforcement detail, corner strength, cracks type, cracking moment, cracks pattern, corner deflection and corner efficiency. The specimens are designed to represent an actual prototype of a portal frame corner. The compressive strength of concrete in the test varies from (37.1) to (43.6) MPa, and steel tension ratio in legs is constant at ρ = 0.0081 in all test specimens. The nominal dimensions of the tested corners are (1077.8 mm) in overall length, (600 mm) in height and (150mm) in thickness, the nominal width, and the effective depth for all corner's leg section is held constant at (150 mm) and (129 mm) respectively. All corners are supported to be hinged in one leg by two hooks and rolled in other leg, also all corners are loaded by steel frame where, it produces moment tends to open the angle. Concrete strains at three different loading stages are recorded for each tested corner; also load deflection curves were plotted. Throughout the test operation crack patterns were drawn and the mode of failure of the tested corners is identified, which is divided into two types (flexural and bearing) failure. It was found that reinforcement detailing in corners subjected to moment tends to open the corner has important effect on the strength and the mode of failure of the corner. Depending on the results of the current experimental work some details are recommended to be used in the field work.يستعرض البحث الحالي دراسة عملية لمقاومة وتصرف أنواع متعددة من تفاصيل التسليح للأركان الخرسانية المعرضة لعزوم إنحناء تعمل على فتح الزاوية. تم فحص (10) نماذج لتفاصيل تسليح مختلفة في منطقة الأركان لدراسة تأثير تفاصيل التسليح، مقاومة الخرسانة، نوع التشققات، عزوم التشققات، أشكال التشققات، هطول الركن الخرساني وكفاءته. صممت النماذج لكي تمثل وتحاكي أركان الهياكل الإنشائية. مقاومة إنضغاط الخرسانة في الفحوصات تراوحت بين (37,1 و 43,6) ميكاباسكال، نسبة حديد الشد في سيقان الأركان كانت ثابتة وتساوي(ρ = 0.0081) لكل النماذج المفحوصة. أبعاد الأركان التي تم فحصها هي (1077,8ملم للطول، 600ملم للإرتفاع و 150ملم للسمك). تم الحفاظ على العرض والعمق الفعال ثابتاً لسيقان كل الأركان وبما يساوي (150ملم و 129ملم) على التوالي. أسندت جميع الأركان على شكل مفصلي في أحد السيقان بإستخدام عقفتين وأسندت الجهة الأخرى بمفصل متحرك. تم تحميل جميع الأركان بواسطة هيكل فولاذي يقوم بتوليد عزم يعمل على فتح الزاوية. تم تسجيل الإنفعالات في الخرسانة لثلاثة مراحل تحميل مختلفة ولكل ركن تم فحصه كما وتم رسم منحيات الحمل والإزاحة. أثناء عملية الفحص تم رسم التشققات الحاصلة في الركن الخرساني وتحديد نوعية الفشل الحاصلة والتي كانت على نوعين (فشل إنحناء أو إرتكاز). لقد تبين بأن تفاصيل التسليح في الأركان الخرسانية المعرضة لعزوم انحناء تعمل على فتح الزاوية لها تأثير كبير على مقاومة ونوع الفشل الحاصل في الركن الخرساني. بالإعتماد على النتائج المستحصلة من البحث الحالي تم إختيار عدد من التفاصيل والتوصية بإعتمادها في المجال الحقلي.


Article
A COMPARISON OF (CBR) SOAKED TEST WITH BRITISH SPECIFICATIONS FOR FINE-GRAINED SOILS FROM AL-KUT IN IRAQ
مقارنة اختبار معدل التحمل (CBR) المغمور مع المواصفات البريطانية لتربة دقيقة الحبيبات من الكوت في العراق

Loading...
Loading...
Abstract

The California bearing ratio (CBR) test has been widely used in pavement design since mid 1940's. It is a relative measure of sub-grade soil or base/sub-base aggregate strength. Nine samples, about 50 kg are taken from different test pits dig to 1.5m from natural ground surface, the soil is fine grained either silt or clay. The nine (CBR) specimens were compacted at optimum moisture content and at 95% of the maximum dry density of the modified compaction test were prepared. All specimens were soaked for periods of 96hr with more than 4.5kg surcharge load. Penetration test was done for both two faces (top and bottom) of the specimen. The tests denoted that most CBR curves are convex upwards so no correction is needed. CBR number is less than 20 so is very poor to fair, where the best using for sub grade due to its fine grained soil. Mostly CBR number that is calculated from bottom face is grater than top face, as they are less wetting than top face. The paper reveals that most CBR values are small, depended from 5mm penetration of the bottom face of specimens, which no correction method is needed for curves. فحص معدل التحمل (CBR) يتم استخدامه بشكل واسع في تصميصم الطرق منذ منتصف أربعينات القرن الماضي. حيث يعتبرالفحص مقياس نسبي لقوة تربة التدرج او ركام طبقات السبيس او تربة التسوية. تسعةعينات بحدود 50 كغم اخذت من حفر اختبارية مختلفة بحفر يصل الى 1,5 متر من سطح الارض, التربة هي دقيقة الحبيبات أما غرين او طين. نماذج CBR)) التسعة قد تم رصها حسب محتوى الرطوبةالأمثل واعدادها عند مستوى 95% من الكثافة الجافة القصوى لفحص الرص المعدل .


Article
EFFECT OF AGGREGATE PROPERTIES ON HOT MIX ASPHALT PERFORMANCE
تأثير خواص الركام على اداء الخلطة الاسفلتية الحارة

Loading...
Loading...
Abstract

Mineral aggregates make up 90 to 95% of a HMA mix by weight or approximately 75 to 85% by volume. The properties of the mineral aggregates have significant affects in performance of our local roadways which offers the possibility of investment in these properties towards resisting different ranges of external applied loads and environmental conditions. For this reason, the performance properties susceptibility due to aggregate properties (Consensus and Source) is going to be evaluated with a wide range of blends, fine, medium and coarse gradation mixtures. The selected source property in this study was toughness (% abrasion), and the consensus property used in this study was angularity (% crushed). Results show that the medium graded mixtures were more susceptible in terms of Marshall Stability due to the change in % abrasion and % crushed aggregate, while the coarse graded mixtures were more susceptible in terms of Marshall Flow due to the change in % abrasion and % crushed aggregate.يشكل الركام حوالي 75 % الى 85 % من حجم الخلطة الاسفلتية الحارة و 90 الى 95 % من وزن الخلطة. ونوعية الركام المعدني له تاثير كبير على اداء طرقنا المحلية، والذي يوفر امكانية استثمار هذه الخواص باتجاه مقاومة مختلف مديات القوى المسلطة الخارجية والظروف البيئية. لهذا السبب اصبح من الضروري تقييم تأثرية الخواص الادائية للخلطة الاسفلتية نتيجة التغيير في خواص الركام ( الخواص المصدرية والخواص المتفق عليها) باستعمال مجال واسع من التدرجات الناعمة والمتوسطة النعومة ( الكثيفة) والخشنة. وفي هذه الدراسة تم تقييم خاصية المصدر بالاعتماد على خاصية القساوة وتقييم خاصية الركام المتفق عليها وهي التزاوي . اظهرت نتائج الدراسة بان الخلطة الاسفاتية ذات التدرج الكثيف تتأثر بشكل اكبر بتغيير خواص الركام من ناحية ثباتية مارشال. اما الخلطة الاسفلتية ذات التدرج الخشن فقد اظهرت تاثرية اكبر عند تغيير خواص الركام من ناحية جريان مارشال.


Article
REUSE OF TREATED SANITARY SEWAGE IN NAJAF CITY FOR AGRICULTURAL PURPOSES
إعادة استعمال مياه الصرف الصحي المعالجة في محطة معالجة المياه الثقيلة في مدينة النجف للإغراض الزراعية

Loading...
Loading...
Abstract

Sanitary sewage treatment plants can be considered as a source for water that can be used for different purposes. The agricultural sector is a steady and very big potential consumer of reclaimed water . so , treated sewage reusing in agricultural purpose is a good goal where it requires simpler treatment in comparison with other purposes In this study , the quality of treated sewage in Najaf sewage treatment plant have been evaluated and compared with standard specifications of America, Egypt and Iraq water quality that used for agricultural purposes. The evaluation process includes samples collection from effluent of treatment plant for a period of (12) months from January 2009 to January 2010. Then measuring the quality of treated sewage which includes measurement of Biochemical Oxygen Demand (BOD), Suspended Solid (S.S) ,Total Dissolved Solid (TDS), and PH .Also concentration of chemical elements which may cause harmful effect on plants like Cl, Based on the results of this study it was found that: (1) Biochemical Oxygen Demand, Suspended solid , Total Dissolved Solid and PH values of effluent treated sewage of all date of measurement are within the maximum allowable range according to the Egyptian Standards and American Standards. (2) the concentrations of values of chlorine (Cl),sulphate (SO4), Phosphate (PO4), Sodium (Na) and Calcium(Ca) are :83%, 75%, 100%, 75%, 92% respectively are less than the Egyptian allowable rang while 75% of magnesium (Mg) values are exceeding the allowable limit. (3) TDS, PH, PO4, NO3 and Ca values of effluent treated sewage of all data of measurement are within the Iraqi allowable range. (4) The concentration values of BOD, S.S, Na and Mg are 58%, 75%, 75% and 1% respectively are less than the Iraqi allowable range. (5) no sodicity problem in the soil as a result of the use of treated water effluent from Najaf sewage treatment plant. يمكن اعتبار مياه الصرف الصحي مصدرا للمياه التي يمكن استخدامها للأغراض المختلفة . القطاع الزراعي هو المستهلك الكبير للمياه المستصلحة , لذلك إعادة استخدام مياه الصرف الصحي المعالجة للأغراض الزراعية هو هدف جيد حيث يتطلب معالجة بسيطة قياسيا بالمعالجات المطلوبة للإغراض الأخرى . في هذه الدراسة تم تقييم المياه المعالجة في محطة النجف ومقارنتها بالمواصفات القياسية المستخدمة للأغراض الزراعية حيث تم مقارنتها بالمواصفات المصرية والأمريكية والعراقية . عملية التقييم تتضمن جمع العينات من المياه المعالجة الخارجة من محطة النجف لفترة ( 12) شهرا من كانون الثاني 2009م إلى كانون الثاني 2010م ومن ثم تم قياس نوعية المياه المعالجة والتي تشمل المتطلب الحيوي للأوكسجين , المواد العالقة , المواد الذائبة الكلية , الأس الهيدروجيني وقياس تركيز بعض العناصر الكيمياوية التي لها تاثيرات ضارة على النباتات مثل الكلور . اعتمادا على نتائج هذه الدراسة يمكن استنتاج 1- قيم المتطلب الحيوي للأوكسجين , المواد العالقة , المواد الذائبة الكلية والأس الهدروجيني للمياه المعالجة الخارجة من المحطة ولكل القياسات هي ضمن الحدود المسموحة حسب المواصفات المصرية والأمريكية . 2- قيم تراكيز ( الكلور , الكبريتات , الفوسفات , الصوديوم والكالسيوم) هي 83% ، 75% ، 100% ، 75% ، 92% على التوالي اقل من الحدود المصرية المسموحة بينما 75% من قيم المغنيسيوم تتجاوز الحد الاعلى. 3- قيم الاملاح الذائبة الكلية، الاس الهيدروجيني، الفوسفات، النترات والكالسيوم للمياه المعالجة الخارجة من المحطة ولكل القياسات هي ضمن الحدود المسموحة حسب المواصفة العراقية. 4- قيم تراكيز المتطلب الحيوي للاوكسجين، المواد العالقة، الصوديوم والمغنيسيوم هي 58% ، 75% ، 75% ، 1% على التوالي اقل من الحدود العراقية المسموحة. 5- لا توجد مشكلة صودية في التربة نتيجة استخدام المياه المعالجة الخارجة من محطة معالجة مياه الصرف الصحي في النجف.


Article
SHEAR BEHAVIOR OF HYBRID REINFORCED CONCRETE BEAMS
سلوك القص للعتبات الخرسانية الهجينة

Loading...
Loading...
Abstract

This study present experimental investigation on shear behavior of hybrid rectangular cross section reinforced concrete beams strengthened with high strength concrete on compression zone of beams. The experimental work contain six specimens, three with normal strength concrete at all section and others contain high strength concrete in compression zone. The effect of inclusion layer of high strength concrete on shear strength, ductility, deflection and cracking load are studied in this investigation. Experimental results showed that the ultimate shear strength, ductility deflection and cracking load are increased when used high strength concrete in compression zone. تقدم هذه الدراسة بحثاً عملياً لسلوك القص للعتبات الخرسانية المسلحة ذات مقطع مستطيل المقواة بالخرسانة عالية المقاومة في منطقة الانضغاط. يتضمن الجزء المختبري ستة نماذج, ثلاثة منها تحوي خرسانة عادية المقاومة في كل المقطع والثلاثة الاخرى تحوي خرسانة عالية المقاومة في منطقة الانضغاط. تأثير استخدام طبقة من الخرسانة عالية المقاومة على مقاومة القص, المطيلية, التشوهات وحمل التشقق تمت دراسته في هذا البحث. اظهرت النتائج المختبرية بان هناك زيادة في مقاومة القص والمطيلية والهطول وكذلك حمل التشقق عندما استخدمت الخرسانة عالية المقاومة في منطقة الانضغاط.


Article
ESTIMATING DELAY TIME AT PALESTINE STREET INTERSECTIONS IN BAGHDAD CITY USING HCM AND SIDRA MODELS
تخمين زمن التأخير في تقاطعات شارع فلسطين في مدينة بغداد باستخدام موديلات HCM و SIDRA

Loading...
Loading...
Abstract

The objective of this paper is to the estimate delay time at two important intersections in Baghdad City using Highway Capacity Manual Model (HCM) ,which is widely used for estimating delay at signalized intersections in Iraq, and Signalized and Unsignalized Intersection Design and Research Aid (SIDRA INTERSECTION 4) Model. Field traffic volumes and control delay were measured during peak and off-peak periods. Data on geometric design elements and signal timings and phasing were measured through a field survey. The results of the analysis indicated that SIDRA INTERSWCTION4 using HCM model was found to be the best in the comparison with the field values by observed percent of difference. Therefore a proposed model is build by derive a new parameters of the uniform delay term (d1) and random delay term (d2) for non-lane state. This model is validated on Art College Intersection. The results show that the predicted model cannot be used for other intersections. Then a proposed model is build for Art College Intersection.الهدف من هذا البحث هو تخمين قيم زمن التأخير في تقاطعين مهمين في مدينة بغداد باستخدام موديلي سعة الطرق (HCM)، الشائع استخدامه في تخمين قيم زمن التأخير في التقاطعات العاملة بنظام الاشارة الضوئية في العراق، و (SIDRA INTERSECTION 4). تم مسح الحجوم المرورية وقيم زمن التأخير الحقلية في موقع التقاطعات في ساعات الذروة وغيرها. وتم أيضاً مسح الخصائص الهندسية وعناصر زمن الدورة الضوئية وأطوارها لكل تقاطع. نتائج التحليل بينت أن برنامج SIDRA INTERSECTION 4)) باستخدام موديل (HCM) أعطى أفضل النتائج بعد المقارنة مع القيم الحقلية لزمن التأخير بنسبة اختلاف واضحة. لذلك تم استنباط موديل بمعايير جديدة لمتغير زمن التأخير المنتظم (d1) ومتغير زمن التأخير العشوائي (d2) لحالة جريان غير منتظمة. تم تدقيق صحة النتائج لهذاالموديل بتطبيقه في حساب زمن التأخير في تقاطع كلية الفنون الجميلة. بينت النتائج ان الموديل لايمكن تطبيقه على تقاطعات أخرى. لذا تم استنباط علاقة أخرى لتقاطع الفنون الجميل.

Table of content: volume:4 issue:1