Table of content

Wasit Journal of Engineering Sciences

مجلة واسط للعلوم الهندسية

ISSN: 23056932
Publisher: Wassit University
Faculty: Engineering
Language: Arabic and English

This journal is Open Access

About

Refereed journals accept research from both inside and outside Iraq, in Arabic and English in all the journals Science and Engineering, which has not previously published in any scientific journal or scientific conference proceedings published by the Faculty of Engineering / University of Wasit by two issues a year.

Loading...
Contact info

karrarali@uowasit.edu.iq

Table of content: 2014 volume:2 issue:2

Article
Study the Effect of AL Shuwaja Depression Flood On Ground Water of East Tigris River in Wasit Province
دراسة تأثير مياه منخفض الشويجة على المياه الجوفية في منطقة شرق دجلة في واسط

Authors: Ali N. Hilo علي ناصر حلو
Pages: 1-11
Loading...
Loading...
Abstract

Present study was conducted at al Shuwaja depression east of wasit to evaluate the impact of surface water and it is effect on regional ground water. The study done with a system of 38 wells along line of 38 km passes the area of study. The work divided the line of study area in to three regions, one called the mid-section locate in the path of flood flow, and the other first and third on shoulder of the depression, right and lift. To assess the level of the pollution in ground water. The study shows an effect of the surface water on concentration of Mg, Cl and Na by increasing the concentration in depression in comparism with the other sector’s first and third. Also the study show that the effect of flood on ground water was to decrease the concentration of total dissolved solids (TDS), TSS, NaCl, and SO4. The study suggest to avoid the harem effect of water in depression on ground water by optimize and reduce the detention time of the flood water by pumping it to Tigris River at effluent of depression.تعتبر المياه الجوفية من المصادر المهمة للمياه في العالم ومن المصادر المهمة في العراق تم في هذا البحث دراسة تأثير المياه المتجمعة في منخفض الشويجة في واسط وتراكيزها على تراكيز ونوعية المياه الجوفية في المنطقة قيد الدراسة. استخدمت في هذه الدراسة منظومة من الابار تم حفرها على طول خط الدراسة البالغ (38 كم) وبمسافة (1كم) بين بئر واخر . وتم تقسم خط الدراسة الى ثلاثة مناطق المنطقة الاولى من (0-7 كم) ايسر والمنطقة الثانية من (7-29 كم) وهي منطقة منخفض الشويجة والمنطقة الثالثة من (29-38كم) على يمين المنخفض. تم في هذا البحث دراسة تأثير مياه الفيضانات المتجمعة في منخفض الشويجة من خلال تقييم تأثير انتشار الملوثات المتمثلة في الأس الهيدروجيني (PH)، المواد الذائبة الكلية(TDS) , ايونات الكبريتات وايونات الصوديوم على نوعية المياه الجوفية ضمن منطقة الدراسة. تم التوصل من خلال الفحوصات المختبرية ضمن شهر ايار لعام 2008 الى ان تأثير مياه منخفض الشويجة على المياه الجوفية يؤدي الى زيادة في تراكيز المغنسيوم (Mg), الصوديوم (Na) و اوكسيد الكبريت (SO4) ضمن المسافة (7-29 كم) و كذلك يودي الى انخفاض في تراكيز ال (CL) و (TSS) و (TDS ) و (NaCl) ضمن المنخفض. بينت الدراسة ارتفاع عالي في تراكيز المكونات في المياه الجوفية بصورة عامة عن مقبوليتها ضمن المعايير العالمية. و اوصت الدراسة ان يتم تقليل فترة البقاء لمياه الفيضانات المتجمعة ضمن منخفض الشويجة الى اقل فترة ممكنة لتلافي زيادة التراكيز في المياه المتجمعة نتيجة التبخر وعمل معادلة موازنة مائية يتم بموجبها اطلاق التصاريف الى نهر دجلة في منطقة اتصال المنخفض بالنهر.

Keywords


Article
Experimental investigation of vapor compression refrigeration system performance using Nano-refrigerant
استقصاء تجريبي لأداء منظومة تبريد انضغاطيه باستخدام وسيط تبريد نانوي

Loading...
Loading...
Abstract

Experimental investigation of vapor compression refrigeration system performance using Nano-refrigerant is presented in this work. Nano-refrigerant was prepared in current work by mixing 50 nanometers diameter of copper oxide CuO nanoparticles with Polyolester lubrication oil and added to the compressor of the refrigeration system to be mixed with pure refrigerant R-134a during its circulation through refrigeration system. Three concentrations (0.1%, 0.25%, and 0.4%) of CuO-R134 a Nano-refrigerant are used to study the performance of the refrigeration system test rig and to investigate the effect of using Nano-refrigerant as a working fluid compared with pure refrigerant R-134a. The results showed that, the increasing in concentration of CuO nanoparticles in the Nano-refrigerant will significantly enhance the performance of the refrigeration system, as adding nanoparticles will increase the thermal conductivity, heat transfer and improve the thermo-physical properties of Nano-refrigerant. Investigation of performance parameters for refrigeration system using Nano-refrigerant with 0.4% concentration compared with that for pure refrigerant R-134a shows that, Nano-refrigerant has reflect higher performance in range of 10% and 1.5% increase in COP and refrigeration effect respectively and 7% reduction in power consumption for refrigeration system. It can be concluded that, Nano-refrigerants can be efficiently and economically feasible to be used in the vapor compression refrigeration systems. يقدم هذا البحث استقصاء تجريبي لأداء منظومة تبريد انضغاطيه باستخدام وسيط تبريد نانوي. تم تحضير وسيط التبريد النانوي خلال العمل الحالي بخلط جسيمات نانوية من اوكسيد النحاس (CuO) بقطر 50 نانومتر مع زيت التشحيم بوليليستر لمنظومة التبريد وأضيف الى ضاغط المنظومة حيث يخلط مع وسيط التبريد R-134a عندما ’يضغط خلال اجزاء منظومة التبريد. تم تحضير واستخدام وسيط تبريد نانوي بثلاثة تراكيز (0.4% , 0.25% , 0.1%) من CuO-R134a لدراسة اداء محطة فحص لمنظومة تبريد انضغاطيه ولاستقصاء تأثير استخدام وسيط تبريد نانوي كمائع عامل مقارنة مع وسيط التبريد R-134a . أظهرت النتائج , أن زيادة تركيز الجسيمات النانوية لأوكسيد النحاس في وسيط التبريد النانوي سوف تحسن اداء منظومة التبريد الانضغاطية بشكل واضح لان اضافة هذه الجسيمات النانوية تؤدي الى زيادة الموصلية الحرارية وانتقال الحرارة وكذلك تحسن الميزات الفيزيائية – الحرارية لوسيط التبريد النانوي. استقصاء معلمات الاداء لمنظومة التبريد الانضغاطية باستخدام وسيط تبريد نانوي بتركيز (0.4%) مقارنة مع وسيط التبريد R-134aأظهر بأن وسيط التبريد النانوي قد أعطى اداء افضل من خلال زيادة قيم معامل الاداء وتأثير التبريد بحدود 10% و 1.5% على التوالي مع تخفيض 7% من استهلاك القدرة الكهربائية لمنظومة التبريد. يمكن الاستنتاج بان وسائط التبريد النانوية تعتبر مجدية اقتصاديا وكفؤة اذا ما استخدمت في منظومات التبريد الانضغاطية.


Article
An Investigation of Natural convection Heat Transfer in a cubic Enclosure with Oriented Partial Partitions at Different Angles
التحقق في الحمل الحراري الحر داخل حيز مكعب يتضمن حواجز تميل بزوايا مختلفة

Loading...
Loading...
Abstract

Natural convection heat transfer in an enclosure provided with inclined partitions to the two adiabatic sides, heated from the bottom with uniform heat flux and cooled from the top at constant temperature is studied experimentally and numerically in this work. The inclined partitions is well covered with an insulated material, so that, it can be assumed as parts of the adiabatic walls that places on. The governing parameter, Rayleigh number, is fixed in this work within 2.6x1011, so that the effect of inclination angles of the two side’s partitions can be investigated. The inclination angles of the two baffles range as (0o ≤ and ≥ 150o). In numerical solution the effect of turbulence is modelled using (k-ε) model. Some applications need to use the enclosed fluid layers as insulation, so that one purpose of this work deals with improve the insulating properties of fluid layers. The experimental and numerical works are done in 36 runs, grouped into 6 collections. Each collection with 6 runs done under a fixed inclination angle of one baffle and change the second baffle inclination angle to investigate the enclosure flow field and heat transfer. The result shows that a multi cells forms when the two baffles aboard to each other’s, which is a reason to make a separation between a cold, and hot circulation cells that forms in the enclosure and act as insulator. It is also conclude that for all cases, the long insulated baffle of any inclination angle causes a reduction to the heat exchange inside the enclosure due to the damping cause to the flow field. The less average Nusselt number occurs when the two angles are equals, and the worst case is (θ=β=90o)الحمل الحراري الحر داخل مغلف مسخن من الاسفل بفيض حراري ثابت ومبرد من الاعلى بدرجة حرارة ثابتة في حين عزلت الجوانب الاخرى حراريا وثبت حواجز مائلة بزوايا مختلفة على جانبين متقابلين تمت دراستها عمليا ونظريا. تم تغليف الحواجز بمادة عازلة بشكل جيد لتكون وكأنها جزء من الجدران المعزولة حراريا. تم تثبيت عدد رالي للدراسة على 2.6x1011 لغرض ايجاد تأثير زوايا ميلان الحاجزين. مدى زوايا ميلان الحاجزين ( اكبر من او يساوي 0oو اصغر من او يساوي 150o). تم تمثيل تأثير الجريان الاضطرابي في الحل العددي باستخدام نمذجة (k-ε). بعض التطبيقات تحتاج الى خصائص العزل الحراري لطبقات المائع قرب السطح الساخن، لذلك فان احدى اهداف هذه الدراسة تعنى بتطوير هذه الخصائص. الدراسة العملية والنظرية اجريت بعمل 36 تجربة على شكل ستة مجاميع، وكل مجموعة دراسية تضمنت ستة تجارب تحت تأثير تثبيت زاوية ميلان الحاجز بإحدى الجهات وتغير زاوية ميلان الحاجز في الجانب الاخر لغرض معرفة تأثير اختلاف الميلان على حقل الجريان والتوزيع الحراري داخل المغلف. النتائج اظهرت حصول عدد كبير من الخلايا الدوامية عندما يكون الحاجزين متقاربين ، حيث تعمل هذه الخلايا على احداث منطقة عازلة بين السطحين الساخن والبارد. كما تم استخلاص ان الحواجز المعزولة حراريا والمائلة باي زاوية والمثبتة على جانبي المغلف تعمل على احباط عملية انتقال الحرارة داخل المغلف بسبب احباط حركة حقل الجريان. ان اقل معدل لعدد نسلت في جميع التجارب ال36 حدث عندما كانت (θ=β=90o).


Article
Study the Effect of AL Shuwaja Depression Flood On Ground Water of East Tigris River in Wasit Province
تعزيز جودة الصورة بطريقة كفؤة لتسوية المدرج الإحصائي

Loading...
Loading...
Abstract

A two Level Image Quality enhancement is proposed in this paper. In the first level, Dualistic Sub-Image Histogram Equalization DSIHE method decomposes the original image into two sub-images based on median of original images. The second level deals with spikes shaped noise that may appear in the image after processing. We presents three methods of image enhancement GHE, LHE and proposed DSIHE that improve the visual quality of images. A comparative calculations is being carried out on above mentioned techniques to examine objective and subjective image quality parameters e.g. Peak Signal-to-Noise Ratio PSNR values, entropy H and mean squared error MSE to measure the quality of gray scale enhanced images. For handling gray-level images, convenient Histogram Equalization methods e.g. GHE and LHE tend to change the mean brightness of an image to middle level of the gray-level range limiting their appropriateness for contrast enhancement in consumer electronics such as TV monitors. The DSIHE methods seem to overcome this disadvantage as they tend to preserve both, the brightness and contrast enhancement. Experimental results show that the proposed technique gives better results in terms of Discrete Entropy, Signal to Noise ratio and Mean Squared Error values than the Global and Local histogram-based equalization methodsلتعزيز جودة الصورة يقوم هذا البحث باستخدام طريقة مكونة من مرحلتين , في الأولى يتم تجزئة الصورة الأصلية إلى قسمين على أساس مقدار قيمة المتوسط في الصورة الأصلية وحسب طريقةDSIHE . في المرحلة الثانية و مع ارتفاع نسبة الضوضاء التي قد تظهر على شكل نبضات في الصورة الناتجة من معالجة المرحلة الأولى حيث يتم التعامل مع الضوضاء ومعالجته . تم عرض ثلاث طرق التعزيز الصورة وهي GHE، LHE,DSIHE ثم الطريقة المقترحة التي من شأنها تحسين جودة الصورة بكفاءة عالية. تم أجراء تنفيذ العمليات الحسابية على التقنيات المذكورة أعلاه لدراسة الجوانب الموضوعية لهذه الطرق وكذلك الجوانب الذاتية لها والتي منها مثلا PSNR نسبة الإشارة إلى الضوضاء ، والأنتروبياH ومعدل مربع الخطأ MSE لقياس جودة الصور الرمادية . أن التقنيات المعروفة مثلLHE وكذلك GHE تميل إلى تغيير متوسط سطوع صورة إلى مستوى منتصف النطاق الرمادي فيشوه بالتالي حدود الصورة ومن ثم يحد من مدى ملاءمتها لتعزيز التباين في الأجهزة الإلكترونية المستخدمة مثل شاشات التلفزيون. واحدة من طرق تجاوز هذه المشكلة هو استخدام معزز الصورة من نوع DSIHE لأنها تميل للحفاظ على حدود الصورة وبنفس الوقت فهي تعزز السطوع والتباين فيها . وقد اظهرت النتائج أن الأسلوب المقترح يعطي نتائج أفضل من حيث الانتروبيا المتقطعة و نسبة الإشارة إلى الضوضاء ومتوسط الخطأ التربيعي نسبة الى التقنيات الأخرى مثل GHE وتقنية LHE.


Article
Passive Solar Energy for Heating Buildings
الاستخدام السلبي للطاقة الشمسية في تدفئة المباني

Loading...
Loading...
Abstract

This research includes the construction of a mathematical model for thermal equilibrium equations in different sections of wall collect and stores heat (Tromp Wall) that which consider one of the most important passive solar heating system. Differential equilibrium equations of this model were solved by using numerical solution based on control volume method with the help of computer program which has been developed for this purpose .In order to study the effect of some design parameters, such as thickness of wall and type of constructed materials, the solution has been applied for five types of this wall. Three of them which are made of concrete with different thicknesses 10 cm, 20 cm and 30 cm, and the two other are made of brick and stone with 20 cm thickness .The results of the solution that has been reached showed clearly that the wall made of concrete with 20 cm thickness is the best among these walls in term of collection, storage and transfer of heat to the space to be warmed تم في هذا البحث بناء نموذج رياضي يشمل معادلات الاتزان الحراري في مقاطع مختلفة من جدار جامع وخازن للحرارة (جدار ترمب) والذي يعتبر من أهم أنوع أنظمة التدفئة الشمسية السلبية.تم حل معادلات الاتزان الحراري التفاضلية لهذا النموذج باستخدام إحدى طرق الحل العددي المسماة بطريقة الحجم المحكوم وبمساعدة برنامج حاسوب تم وضعه لهذا الغرض استخدمت فيه لغة الفورتران .ولغرض دراسة تأثير بعض العوامل التصميمية على الأداء الحراري للجدار الجامع والخازن للحرارة ، كسمك الجدار ونوع المادة المصنع منه ، فقد طبق الحل على خمس أنواع من هذا الجدار ثلاث منها مصنوعة من الخرسانة بأسماك مختلفة هـي 10cm ، 20 cm ، و30 cm واثنان مصنوعة من الطابوق والحجر بسمك20cm . نتائـج الحـل التي تم التوصل إليها والخاصة بهذه الجدران بيـنت بـأن الجدار الخرساني ذو سمك 20 cmهو الأفضل من بين هذه الجدران من ناحية تجميع وتخزين الحرارة ونقلها إلى الحيز المراد تدفئته

Keywords

Table of content: volume:2 issue:2