research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Heat Transfer Enhancement Using Helical Pipes
تحسين انتقال الحرارة باستخدام الانابيب المحلزنة

Author: Ajaj Helal Zgayer عجاج هلال زغير
Journal: Anbar Journal of Engineering Sciences مجلة الأنبار للعلوم الهندسية ISSN: 19979428 Year: 2012 Volume: 5 Issue: 1 Pages: 126-139
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

The enhancement of laminar forced convection inside helical pipes is studied numerically and compared with plain pipes. The study is achieved numerically using the (Fluent-CFD 6.3.26) software program for solving the governing equations. The heat transfer coefficient and friction coefficient are calculated using the enhancement technique and compared with the plain tube. In this research the factors that affect the enhancement technique using helical pipes are studied, these factors are the ratio of (pitch /pipe length) (SL), Reynolds number and the heat flux applied to the external surface of the pipe.The results showed that there is an increasing in the heat transfer coefficient is related to the decreasing of (SL), increasing of Reynolds number and heat flux. The performance of the helical pipes is evaluated depending on the calculation of (Enhancement ratio), and it’s found that the enhancement ratio increases as Reynolds number increases and (SL) decreases. It is found that the best enhancement ratio was (200%) at (SR=0.05), (Re=2000),(Heat flux=3000W/m2).The results are compared with the literature and there is a good agreement.

يهدف البحث الحالي إلى دراسة تحسين انتقال الحرارة بالحمل ألقسري الطباقي داخل الأنابيب المحلزنة من الداخل (helical pipes) ومقارنة أداءها مع الأنابيب الاعتيادية (plain pipes). أنجزت الدراسة عدديا باستخدام برنامج (Fluent-CFD 6.3.26) لحل المعادلات الحاكمة ومن ثم حساب معامل انتقال الحرارة باستخدام آلية التحسين المستخدمة وكذلك حساب معامل الاحتكاك .تم في هذا البحث دراسة العوامل المؤثرة على تحسين انتقال الحرارة بالأنابيب المحلزنة والمتمثلة بنسبة المسافة الفاصلة SL(خطوة طول الانبوب ) ،رقم رينولدز وكذلك الفيض الحراري المسلط على السطح الخارجي للأنبوب.من نتائج الدراسة لاحظنا زيادة قيمة معامل انتقال الحرارة في حالة نقصان SL ، زيادة رقم رينولدز وزيادة كمية الفيض الحراري المسلط. تم تقييم أداء الأنابيب المحلزنة بالاعتماد على حساب نسبة التحسين Enhancement Ratio . تبين إن نسبة التحسين تزداد بزيادة قيمة رينولدز ونقصان نسبة المسافة الفاصلة SL وكانت أفضل نسبة تحسين (200%) عند حالة ( ( SL=0.05ورقم رينولدز يساوي 2000 وفيض حراري 3000W/m2 .تم مقارنة النتائج مع البحوث السابقة وكانت النتائج متقاربة الى حد بعيد.


Article
An Investigation into Heat Transfer Enhancement by Using Oscillating Fins
دراسة لزيادة معدلات انتقال الحرارة باستخدام الزعانف المتذبذبة

Authors: Ihsan Y. Hussain احسان يحيى حسين --- Karima E.Amori كريمة اسماعيل عموري --- Dheya G. Mutasher ضياء غانم مطشر
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2013 Volume: 19 Issue: 1 Pages: 63-81
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The present work describes numerical and experimental investigation of the heat transfer characteristics in a plate-fin, having built-in piezoelectric actuator mounted on the base plate (substrate). The geometrical configuration considered in the present work is representative of a single element of the plate-fin and triple fins. Air is taken as the working fluid. A performance data for a single rectangular fin and triple fins are provided for different frequency levels (5, 30 and 50HZ) , different input power (5,10,20,30,40 and 50W) and different inlet velocity (0.5, 1, 2, 3, 4, 5 and 6m/s) for the single rectangular fin and triple fins with and without oscillation. The investigation was also performed with different geometrical fin heights ( 50mm and 35mm) and distance between the fins (3mm and 6mm). It is observed that the heat transfer increases with the increase in the frequency and Reynolds number. It is further observed that triple fins with (height=50mm and distance between the fins=3mm) gives better enhancement as compared to other cases, The study shows that the piezoelectric actuator when mounted on the rectangular fins gives great promise for enhancing the heat transfer rate.

العمل الحالي يبحث عدديا وتجريبيا خصائص انتقال الحرارة في زعانف مدمجة مع (Piezoelectric Actuator) ومثبتة على قاعدة الزعانف (Substrate). واخذ بنظر الاعتبار الزعنفة المنفردة والزعانف الثلاثية. واستخدم الهواء كمائع عمل. اختبرت قيم الاداء للزعنفة المنفردة والزعانف الثلاثية لمستويات تردد مختلفة ( 5، 30، و50 هيرتز) ، قدرات ادخال مختلفة (5، 10، 20، 30، 40، و 50 واط ) ، وسرع دخول مختلفة (0.5، 1، 2، 3، 4، 5 و 6 م/ثا ) مع وبدون ذبذبة. وانجز البحث مع ارتفاعات زعانف مختلفة (35 ملم ، 50 ملم ) ، ولمسافات بين الزعانف (3 ملم ، 6 ملم ) . يلاحظ ان انتقال الحرارة يزداد مع زيادة التردد وعدد رينولد . كذلك يلاحظ ان الزعانف الثلاثية مع (الارتفاع=50 ملم والمسافة بين الزعانف=3 ملم) تعطي افضل

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic and English (2)


Year
From To Submit

2013 (1)

2012 (1)