Experimental Study of Behavior of Reinforced Concrete One-Way Slabs Strengthened and Repaired by Ferrocement at Tension Zone
التقصي العملي لمقاومة الانثناء للبلاطات الخرسانية المسلحة ذات الاتجاه الواحد المقواة والمصلحة بغطاء من الفيروسمنت في منطقه الشد

Author: mazan D.Abdullah مازن ديوان عبد الله
Journal: Iraqi Journal of Civil Engineering المجلة العراقية للهندسة المدنية ISSN: 19927428 Year: 2017 Volume: 11 Issue: 3 Pages: 52-67
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

The principal objective of this paper is to investigation the experimental of the flexural behavior of strengthened and repaired reinforced concrete slabs with ferrocement tension zone. The result of tests on 10 simply supported one way slabs were presented, at which include 1control slab, 5strengthened slabs and 4repaired one way slabs. In the strengthened slabs, the cover of the control slab replacing with ferrocement cover, cold joint between ferrocement layer and the slab, connection type between the ferrocement layer and the slab, on the ultimate load, first crack load, the mid span-deflection, crack width and spacing were examined. In the repaired part the slabs were loaded to (55 %) of measured ultimate load of control slab, the effect of the thickness and number of wire mesh layers on crack pattern, mid span deflection and ultimate load was examined. In the repaired part the slabs were loaded to (55 %) of measured ultimate load of control slab, effect of the number of wire mesh layers of ferrocement on the mid span deflection, ultimate load and crack pattern was examined. The experimental results of strengthened and repaired slabs indicate that; the ultimate loads and mid span deflection were more effected by using ferrocement mortar at tension zone. The increase in ultimate load (8.2-18%) for strengthen slab and (9.1-17.3%) for repaired slab respect to the control slab.

ان الغرض من هذا البحث هو تقديم دراسة عملية عن مقاومة الانثناء للبلاطات المقواة والمصلحة باستخدام طبقة الفيروسمنت عند منطقه الشد.تعرض نتائج الاختبارات على 10 بلاطات بسيطه الاسناد تتضمن واحده منها كبلاطه مرجعيه وخمس منها مقواه اربع لدراسة فاعلية عملية الإصلاح. في عملية التقوية تم دراسة تأثير استبدال الغطاء الخرساني العادي من لوح التحكم بواسطة غطاء فيروسيمنت ، نوع الربط بين بلاطه وطبقه الفيروسمنت و تواجد المفصل البارد بين البلاطه وطبقه الفيروسمنت على الحمل الأقصى ,اول حمل تشقق,عرض التشقق و الحمل الأقصى والأود المقابل له. ، أما في حالة الإصلاح فقد تم تسليط ( % 55 ) من الحمل الأقصى للبلاطات المرجعية على البلاطات المراد إصلاحها ودراسة تأثير عدد طبقات المشبكات السلكية وسمك طبقه الفروسمنت على الحمل الأقصى والأود المقابل له بالإضافة إلى تأثيرها الشقوق.نتائج البلاطات المقواه والمصلحه ان االزياده بالحمل الاقصى قد ازدادت بمقدار (8.2-18%) و(9.1-17.3%) على التوالي %) مقارنة بالبلاطات الخرسانية غير المقواة باستخدام لفيروسمنت.

Keywords

: Concrete --- ferrocement --- repair --- slab --- strengthening


Article
Study on Flexural Behaviour and Cracking of Ferrocement Slabs by Neglecting Very Fine Sand
دراسة عن سلوك الانثناء والتشقق للبلاطات الفيروسمنتية بإهمال الرمل الناعم جدا

Author: Mohammed T. Nawar محمد طراد نوار
Journal: Iraqi Journal of Civil Engineering المجلة العراقية للهندسة المدنية ISSN: 19927428 Year: 2018 Volume: 12 Issue: 2 Pages: 11-22
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

This paper presents the experimental results of eight slabs made of Ferrocement. All specimens were )700mm (long, )300mm (wide and )50mm (thick. These specimens were divided into two groups (The first group has four specimens coursed of normal sand gradient and in the other four specimens, the sand that passing from sieve No. 8 was neglected), to investigate behavior of slabs under bending effect and studying the cracks that generated after bending then, comparing the results between these two groups. A thin square welded wire mesh was used as reinforcement. The number of wire mesh layers was varied between 0 to 3 layers. Ultrasonic Pulse Velocity (UPV) Test was used to detect the cracks. The results showed that there was a slight rise in bending for first group slabs compared with second group slabs. Maximum bending strength was achieved for both slab groups with 3 layers of wire mesh. it was shown that there was a significant convergence in the load values required to cause appearing of the first crack and final failure for the two groups. The percentage of ultimate load between slab reinforced with 3 layers and without reinforcement was (25.27%) for the first group, while the increase in ultimate load for a specimen that reinforced with 3 layers was (24.16%) compared to specimen without reinforcement for the same group. On the other hand, the results showed an improvement in the performance of the second group slabs due to its resistance to appearing of cracks resulted from bending. The percentage of increasing cracks after bending for the unreinforced specimen in group 1 was (9%) compared with the unreinforced slab in group 2. Whereas the numbers of cracks number in slab reinforced with 1 and 2 layers in the second group were less than slabs with 1 and 2 layers in the first group about (8.86 %) and (7.77%), respectively. While this percentage for a specimen with 3 layers in group 2 was about (8.62%) less compared to the specimen with 3 layers in group 1.

يقدم هذا البحث النتائج التجريبية لثمانية بلاطات مصنوعة من الفيروسيمنت. جميع العينات هي بطول (700mm)، وعرض ((300mm وسمك (50mm). تم تقسيم هذه العينات إلى مجموعتين: (المجموعة الأولى فيها أربع عينات استخدم فيها رمل ذو تدرج طبيعي والأربعة الأخرى هي المجموعة الثانية وناتجة من إهمال الرمل المار من منخل رقم (8)، لبحث سلوك هذه البلاطات تحت تأثير أحمال الانحناء ودراسة الشقوق التي تولدت بعد فحص الانحناء، ومقارنة النتائج بين هاتين المجموعتين. تم استخدام مشبكات سلكية ملحومة كطبقات تسليح، وقد تراوح عدد هذه الطبقات بين 0 إلى 3 طبقات. استخدم اختبار سرعة النبض للموجات فوق الصوتية (UPV) للكشف عن الشقوق. أظهرت النتائج أن هناك زيادة طفيفة في انحناء البلاطات في المجموعة الأولى مقارنة مع بلاطات المجموعة الثانية قبل حدوث الفشل النهائي. تم الحصول على أعلى قيم للانحناء عند تسليح البلاطة بثلاث طبقات من مشبك الأسلاك ولكلا المجموعتين. كما أظهرت النتائج أن هناك تقارب في قيم الأحمال اللازمة لظهور الشق الأول وأحمال الفشل النهائية لنماذج المجموعتين. فقد كانت نسبة زيادة الحمل النهائي بين العينة المسلحة بثلاث طبقات والعينة الغير مسلحة للمجموعة الأولى هي25.27%)), أما للعينة المسلحة بثلاث طبقات في المجموعة الثانية فقد كانت نسبة الزيادة في الحمل النهائي 24.16%)) مقارنة مع العينة الغير مسلحة لنفس المجموعة. من ناحية أخرى، فقد أظهرت النتائج تحسنا في أداء بلاطات المجموعة الثانية في مقاومة الشقوق الناتجة من الانحناء. وكانت نسبة الزيادة بالشقوق للعينة الغير مسلحة للمجموعة الثانية هي ((9% مقارنة مع نظيرتها في المجموعة الثانية. في حين أن عدد الشقوق بلاطات المجموعة الثانية المسلحة بطبقة واحدة وطبقتين كانت أقل من بلاطات المجموعة الأولى بحوالي (8.86%) و(7.77%) على التوالي. اما نسبة التشققات للعينة المسلحة بثلاث طبقات للمجموعة الثانية اقل بحوالي ( (8.62% بالمقارنة مع العينة المقابلة لها في المجموعة الأولى.