research centers


Search results: Found 3

Listing 1 - 3 of 3
Sort by

Article
Experimental and Numerical Investigation to Evaluate the Performance of Helical Coiled Tube Heat Exchanger
تحقيق عملي وعددي لتقييم أداء مبادل حراري حلزوني الأنبوب

Authors: Qasim Saleh Mahdi قاسم صالح مهدي --- Sahar Abdul Fattah سحر عبد الفتاح عبود --- Firas juma Abd فراس جمعة
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2014 Volume: 18 Issue: 4 Pages: 89-110
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Experimental and Numerical investigation of heat transfer enhancement in shell and helical coil tube heat exchanger is carried out in the present work. Experimental work included design of helical coil heat exchanger with different curvature ratio and coil pitch. Three helical coil tube heat exchangers with different curvature ratio (D/d) 12/1, 15/1, 17/1, 20/1 and 24/1 are studied to choose the optimum one. Four helical coils with different coil pitch 1.8d, 2d, 3d, and 5d has been chosen to study the effect of coil pitch on heat transfer coefficient. From experimental results the curvature ratio 17/1 gives optimum helical coil. Experimental results show increases of coil pitch lead to increasing in heat transfer coefficient of the shell side and indicate that convective heat transfer is increased by Reynolds number as well as Dean Number.Numerical geometry has been built using ansys fluent package 14.1 commercial copy with solid work and gambit software program depends on the optimum design . Numerical results show that the temperature decreases along the coil and the temperature difference effect on heat flow along helical coiled. Also there is different in temperature between each turn. Empirical correlation has been developed to predict Nusselt number at helical coil. The comparison between numerical and experimental results show good agreement.

التحقيق التجريبي والعددي لتحسين انتقال الحرارة لمبادل حراري مكون من أسطوانة (القشرة) وأنبوب حلزوني نفذت في هذا العمل .تضمن العمل التجريبي تصميم مبادل حراري حلزوني مع أفضل نسبة تقوس ودرجة حلزنة. خمسه مبادلات حرارية حلزونية مع نسب تقوس مختلفة24/1, 20/1, 17/1, 15/1, 12/1 درست لاختيار أفضل مبادل حراري حلزوني. أربعة مبادلات حرارية مع درجات حلزنة مختلفة (1.8d, 2d, 3d, 5d) صممت لدراسة تأثير درجة الحلزنة على معامل انتقال الحرارة. الملف الحلزوني الذي له نسبة تقوس17/1 اختير كأفضل ملف حلزوني طبقا للنتائج العملية. زيادة درجة الحلزنة تؤدي إلى زيادة معامل انتقال الحرارة في (القشرة). النتائج العملية تشير إلى إن انتقال الحرارة يزداد بزيادة رقم رينولد بالإضافة إلى رقم ديان.أما الجانب العددي فقد تم استخدام برنامج ansys fluent في رسم الشكل باستخدام برنامج solid workو gambit في التحليل وبالاعتماد على أفضل تصميم. وأظهرت الدراسة العددية ان درجات الحرارة تقل على طول الملف وفرق درجات الحرارة له تأثير على انتقال الحرارة وهناك فرق في درجة الحرارة بين لفة واخرى .تم تطوير معادلة تجريبية لتوقع عدد ناسلت لأنبوب محلزن كما بينت المقارنة بين النتائج العملية والعددية بينت توافق جيد.


Article
Helical Piles Embedded in Expansive Soil Overlaying Sandy Soil
الركائز اللولبية المغروسة فى تربة انتفاخية تستند على طبقة رملية

Authors: Hassan Obaid Abbase حسن عبيد عباس --- Bushra Suhail Al-Busoda بشرى سهيل زبار
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2016 Volume: 12 Issue: 3 Pages: 19-25
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this study, the behavior of square helical piles models (5×5) mm2 embedded in expansive soil bed overlaying a layer of sandy soil was investigated. The sand layer 200mm thickness was compacted into four sub layers in a steel container with diameter 400mm in size. Sandy soil layer was compacted into two relative densities 40% and 80%. The bed of expansive soil 300mm thickness was compacted into six sub layers on sandy soil layer. Model tests are performed with helical pile length 350mm, 400mm and 450mm and with helix diameter 15mm and 20mm. Also, one helix and double helix were used for these piles. Water was allowed to seep from bottom of sandy soil to reach surface of expansive soil through four sand drains around helical pile. This study revealed that the upward movement of helical piles decreases with increasing depth of embedment in the sandy layer, helix diameter and number of helix. The increase in these parameters provides anchorage against uplifting. Helical piles embedded in sandy soil of relative density (40%) have uplift movement more than helical piles of relative density (80%).

فى هذه الدراسة تم دراسة تصرف الركائز اللولبية ذات مقطع مربع بابعاد (5x5) ملم مربع مغروسة بتربة انتفاخية تستند على طبقة من الرمل. التربة الرملية بسمك 200 ملم حدلت باربع طبقات فى اناء حديدى بقطر 400 ملم وتم حدلها بكثافة نسبية 40%و80%. التربة الانتفاخية بسمك 300ملم تم حدلها بست طبقات فوق التربة الرملية. استخدمت ركائز لولبية باطوال 350 ملم و 400 ملم و 450 ملم وصفائح لولبية دائرية بقطر 15ملم و 20 ملم واستخدمت بصورة احادية وثنائية لكل ركيزة. الماء اضيف الى التربة من الاسفل عن طريق التربة الرملية ويرتفع للاعلى عن طريق اربع مبازل رملية حول الركيزة. وجد من خلال هذه الدراسة ان حركة الركائز اللولبية للاعلى تقل بازدياد العمق فى التربة الرملية وزيادة قطر الصفيحة وعددها. الركائز اللولبية المغروسة فى التربة الرملية ذات الكثافة النسبية 40% تكون حركتها للاعلى اكثر من المغروسة فى ذات الكثافة النسبية 80% .


Article
Experimental Investigation of the Effect of Curvature Ratio on Heat Transfer in Double Pipe Helical Heat Exchanger
تحقيق عملي من تأثير نسبة الأنحناء على انتقال الحرارة في مبادل حراري حلزوني مزدوج الأنبوب

Author: Hisham Assi Hoshi هشام عاصي حوشي
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2018 Volume: 14 Issue: 1 Pages: 10-18
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Different parameters of double pipe helical coil were investigation experimentally. Four coils were used; three with a curvature ratio (0.037, 0.031, and 0.028) and 11mm diameter of the inner tube while the fourth with 0.033 curvature ratio and 13 mm diameter of the inner tube. The hot water flow in the inner tube whereas the cold water flows in the annulus. The inlet temperatures of hot and cold water are 50 0C and 18 0C respectively. The inner mass flow rate ranges from 0.0167 to 0.0583 kg/s. The results show the Nusselt number increase with increase curvature ratio. The Nusselt number of the coil with 0.037 curvature ratio increases by approximately 12.3 % as compare with 0.028 curvature ratio. The results also reveal that the Nusselt number of the coil with curvature ratio 0.033 increases by approximately 11.6 % as compare with 0.028 curvature ratio for 400 mm coil diameter.

عدة عوامل متغيرة للفائف حلزونية مزدوجة الأنبوب وتم استخدام أربع لفائف. ثلاث مع نسبة انحناء (0.037, 0.031, 0.028) و 11 ملم قطر الأنبوب الداخلي في حين أن الرابع مع 0.033 نسبة انحناء و 13 ملم قطر الأنبوب الداخلي. يتدفق الماء الساخن في الأنبوب الداخلي في حين يتدفق الماء البارد في الحلقة. درجة حرارة مدخل الماء الساخن والماء البارد هي 50 0C 18 0C على التوالي. ويتراوح معدل التدفق الكتلي الداخلي من 0.0167 إلى 0.0583 كجم / ثانية . أظهرت النتائج زيادة عدد نسلت مع زيادة نسبة الانحناء. أن عدد نسلت من الملف نسبة انحناءه 0.037 يزيد بحوالي 12.3 % مقارنة مع الملف نسبة انحناءه 0.028 . كما كشفت النتائج أن عدد نسلت من الملف نسبة انحناءه 0.033 يزيد بحوالي 11.6 % مقارنة مع الملف نسبة انحنائه 0.028 لملف قطره 400 ملم.

Listing 1 - 3 of 3
Sort by
Narrow your search

Resource type

article (3)


Language

Arabic and English (3)


Year
From To Submit

2018 (1)

2016 (1)

2014 (1)