research centers


Search results: Found 10

Listing 1 - 10 of 10
Sort by

Article
The relation between ECG changes and troponin test in patients with non ST segment elevation acute coronary syndrome
العلاقة بين رسم القلب الكهربائي وفحص التروبونين I في مرضى المتلازمة التاجية الحادة غير المصاحبة لإرتفاع قطعة ST

Author: Arwa M. Fuzi Al-Sarraf اروى محمود فوزي الصراف
Journal: Annals of the College of Medicine Mosul مجلة طب الموصل ISSN: 00271446 23096217 Year: 2013 Volume: 39 Issue: 1 Pages: 12-18
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

ABSTRACTObjectives: This article focuses on unstable angina and non ST segment elevation myocardial infarction. The objectives are to clarify different ECG pattern, to correlate it with troponin results, and to evaluate the effects of risk factors. Methods: Seventy patients with clinical diagnosis of acute coronary syndrome were collected from coronary care unit in Ibn Sina Teaching Hospital in Mosul, 20 patients with ST segment elevation were excluded, and ECG changes were evaluated. Forty five patients had troponin I test, and the results were compared to their ECG changes. The risk factors and their numbers were studied. Data statistically analyzed using Z- 2 proportion and Chi-square tests. Results: Fifty patients with a mean age 57 year (SD 13.2), including 26 males and 24 females, show (in order of frequency): ST depression (44%), non-specific ECG (24%), T wave inversion (22%), and BBB (10%). Fifteen (33%) had positive troponin test, most of them were males (80%), showed significant association with T wave inversion (p value= 0.05). Specific ECG changes were associated with male gender, diabetes mellitus, hypertension, and old age (p value<0.03). Troponin positivity was associated with male sex (p value=0.003). Male gender and smoking were associated with positive troponin in significant ECG group (p value<0.04). All patients with positive troponin had at least two risk factors (p value=0.002).Conclusion: ST segment depression was the most common ECG changes in non ST elevation acute coronary syndrome, but T wave inversion was more significantly associated with troponin positivity, which differs from previous studies. Male gender was the most critical risk factor; this was consistent with previous studies. Number of risk factor has important effect on ECG and troponin results.

الخلاصةالأهداف: هذه الدراسة تركز على النوبة القلبية غيرالمستقرة، وإحتشاء عضلة القلب غير المصاحب لإرتفاع قطعة ST . الأهداف هي توضيح أنماط رسم القلب الكهربائي، إختبار إيجابية فحص تروبونين I ، وتقييم عواملِ الخطورة.الطريقة: سبعون مريضا شخصوا سريريا بالمتلازمة التاجية الحادة جمعوا من وحدة العناية القلبية في مستشفى ابن سينا التعليمي في الموصل، بعد إستثناء 20 حالة مصاحبة لإرتفاع قطعةST ، تم دراسة أنماط تغييرات رسم القلب لهؤلاء المرضى. وأجري إختبار التروبونين لخمسة وأربعون مريضا منهم، وقورنت نتائج إختبار التروبونين لديهم مع تغييرات رسم القلب الكهربائي. درست عوامل الخطورة وعددها وتأثيرها على أنماط رسم القلب الكهربائي ونتائج إختبار التروبونين. حللت نتائج هذه البيانات إحصائيا بإستخدام إختباري كاي وZ.النَتائِج: تم تشخيص خمسين مريضا بالمتلازمة التاجية الحادة غير المصاحبة لإرتفاع قطعة .STمتوسط أعمارهم 57 سنة: (26 ذكرا و 24 أنثى). أظهر رسم القلب الكهربائي لديهم التغييرات الآتية (من الأكثر الى الأقل شيوعا) : إنخفاض فطعة ST (44%)، تغييرات غير محددة في رسم الفلب (24% (، إنعكاس موجة T (22% (وحصرالحزيمة BBB ) 10%.( كان إختبار تروبونين إيجابي لدى خمسة عشر مريضا (33%) ، ومعظمهم كانوا ذكورا (80%)، وأظهروا علاقة إحصائية مهمة مع إنعكاس موجة .Tإرتبط وجود تغييرات مهمة في رسم القلب الكهربائي بالعوامل التالية: الجنس الذكر، داء السكري، إرتفاع ضغط الدم، والشيخوخة. فيما إرتبطت إيجابية اختبار التروبونين بالجنس الذكر. كان فحص التروبونين إيجابيا في المجموعة التي أظهرت تغييرات مهمة في رسم القلب في الذكور والمدخنون. كل المرضى الذين أظهروا فحص تروبونين إيجابي كان لديهم عاملي خطورة على الأقل.الخاتمة: إنخفاض القطعة ST كان التغير الأكثر شيوعاً في رسم القلب الكهربائي لمرضى المتلازمة التاجية الحادة غير المصاحبة لإرتفاع قطعة ST، لكن إنعكاس موجة Tكان أكثر إرتباطا بإيجابية فحص التروبونين، وهذا معارض لبعض الدراسات السابقة. الجنس الذكر كان عامل الخطورة الأكثر حرجا في المتلازمة التاجية الحادّة، وهذا كان متسقا مع الدراسات السابقة. عدد عوامل الخطورة له تأثير مهم على رسم القلب الكهربائي ونتائج فحص التروبونين.

Keywords

ECG --- troponin --- ACS


Article
Design And Implementation Of A Biomedical Signals Generator Based On Microcontroller
تصميم وتنفيذ مولد أشارات حيوية بالاعتماد على المسيطر الدقيق

Loading...
Loading...
Abstract

Biomedical signals are one of the most important parameters in the diagnosis, so the doctors and clinical trainers must be familiar with these signals. Biomedical signals generator is an electronic device used to simulate such signals for the above mentioned purpose. The biomedical signals generator (BIO-SG) is a useful tool for biomedical signals devices for calibration , monitoring and incorporate in educational tasks and clinical environments. a biomedical signals generator based on microcontroller and also we use a digital to analog convertor and an amplifier to act as a conditioning circuit for the signal and made it easy to show on an oscilloscope. The device is based on a microcontroller to generate the basic ECG wave and EMG wave, these signals can used as an input to the ECG and EMG machines. the results shows that the generated waves with low error rate compared with the biomedical standard waves.

الإشارات الطبية الحيوية هي واحدة من أهم المعايير في التشخيص، وبالتالي فإن الأطباء والمدربين السريرين يجب أن يكونوا على دراية مع هذه الإشارات. مولد الإشارات الطبية الحيوية هو جهاز إلكتروني يستخدم لمحاكاة مثل هذه الإشارات لغرض المذكورة وهو أداة مفيدة للأجهزة الطبية الحيوية لرصد إشاراتها للمعايرة وتدرج في المهام التعليمية والبيئات السريرية. مولد الإشارات الطبية الحيوية يعتمد على متحكم وأيضا نستخدم المحول الرقمي التناظري إلى ومكبر للإشارات ليكون بمثابة دائرة تكييف للإشارة، وجعل من السهل أن تظهر على راسم الذبذبات. ويستند الجهاز على متحكم ليولد الأساسية ECG موجة وموجة EMG، يمكن استخدام هذه الإشارات كمدخل للآلات ECG وEMG. النتائج تظهر أن الموجات المتولدة مع نسبة الخطأ منخفضة مقارنة مع مستوى موجات الطبية الحيوية القياسية.


Article
Finite Element Based Solution of Laplace's Equation Applied to Electrical Activity of the Human Body
العنصر المحدد لحل معادلة لابلاس مطبقة على النشاط الكهربائي للجسم الأنساني

Author: Zainab T. Baqer زينب توفيق باقر
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2010 Volume: 6 Issue: 4 Pages: 37-51
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Computer models are used in the study of electrocardiography to provide insight into physiological phenomena that are difficult to measure in the lab or in a clinical environment.
The electrocardiogram is an important tool for the clinician in that it changes characteristically in a number of pathological conditions. Many illnesses can be detected by this measurement. By simulating the electrical activity of the heart one obtains a quantitative relationship between the electrocardiogram and different anomalies.
Because of the inhomogeneous fibrous structure of the heart and the irregular geometries of the body, finite element method is used for studying the electrical properties of the heart.
This work describes the implementation of the Conjugate Gradient iterative method for the solution of large linear equation systems resulting from the finite element method. A diagonal Jacobi preconditioner is used in order to accelerate the convergence. Gaussian elimination is also implemented and compared with the Precondition Conjugate Gradient (PCG) method and with the iterative method. Different types of matrix storage schemes are implemented such as the Compressed Sparse Row (CSR) to achieve better performance. In order to demonstrate the validity of the finite element analysis, the technique is adopted to solve Laplace's equation that describes the electrical activity of the human body with Dirichlet and Neumann boundary conditions. An automatic mesh generator is built using C++ programming language. Initially a complete finite element program is built to solve Laplace's equation. The same accuracy is obtained using these methods. The results show that the CSR format reduces computation time compared to the order format. The PCG method is better for the solution of large linear system (sparse matrices) than the Gaussian Elimination and back substitution method, while Gaussian elimination is better than iterative method.

نماذج الحاسبات تستخدم لدراسة التخطيط الكهربائي لعمل القلب للتَزويد برؤية إلى الظواهرِ الفسلجيةِ التي صعبة القيَاْس في المختبرِ أَو في بيئة سريرية. التخطيط الكهربائي لعمل القلب أداة مهمة للطبيب في انهاّ تَتغيّرُ على نحو مميز في عدد مِنْ الشروطِ الباثولوجيةِ . العديد من الأمراض ممكن ان تكتشف بهذا المقياس. بمحاكاة النشاطِ الكهربائيِ للقلبِ يحصلُ على علاقة كمّية بين التخطيط الكهربائي و أشياء غير سوية مختلفة. بسبب التركيب الغير متجانس الليفي للقلب والجسم الهندسي الغير منتظم, طريقة العنصر المحدد استخدمت لدراسة الخواص الكهربائية للقلب.يصف هذا العمل بناء طريقة التدرج المرافق التكرارية لحل مجموعة المعادلات الخطية الكبيرة الناتجة من طريقة العنصر المحدد. ان طريقة الشرط الاولي لجاكوبي القطري ( PCG) استخدمت لتسريع الاقتراب. طريقة الحذف الكاوسي ايضا بنيت وقورنت معها ومع الطريقة التكرارية. لقد تم استخدام انواع مختلفة من طرق خزن المصفوفات مثل طريقة الصف المتفرق المضغوط للحصول على افضل اداء. لغرض التحقق من دقة الحسابات لتحليل العنصر المحدد,اسلوب تقني تبني لحل معادلة لابلاس التي تصف النشاط الكهربائي لقلب الانسان ضمن شروط (العالمان) درشلت ونيومان. مولد شبكة الي بني بأستخدام لغة برمجة C++ . في البداية برنامج العنصر المحدد الكامل بني لحل معادلة لابلاس. نفس الدقة حصل عليها من هذه الطرق. طريقة الشرط الاولي لجاكوبي القطري PCG هي الافضل في النظام الخطي الكبير من طريقة الحذف الكاوسي و طريقة الحذف الكاوسي افضل من الطريقة التكرارية.


Article
Noise Removal of ECG Signal Using Recursive LeastSquare Algorithms
إزالة ضوضاءِ التي تَستعملُ أقلّ تكراريةً الخوارزمياتِ المربّعةِ

Author: Noor K. Muhsin نور كمال محسن
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2011 Volume: 7 Issue: 1 Pages: 13-21
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This paper shows an approach for Electromyography (ECG) signal processing based on linear and nonlinear adaptive filtering using Recursive Least Square (RLS) algorithm to remove two kinds of noise that affected the ECG signal. These are the High Frequency Noise (HFN) and Low Frequency Noise (LFN). Simulation is performed in Matlab. The ECG, HFN and LFN signals used in this study were downloaded from ftp://ftp.ieee.org/uploads/press/rangayyan/, and then the filtering process was obtained by using adaptive finite impulse response (FIR) that illustrated better results than infinite impulse response (IIR) filters did.

هذا البحث يبحث نظرةً لمعالجةِ إشارات تخطيط القلب مستندة على التَرْشيح التكيفيِ اللاخطّيِ والخطيِّ الذي يَستعملُ خوارزمية أقلّ تكراريةً المربعِ لإزالة إثنان مِنْ أنواعِ الضوضاءِ الذي المؤثره على إشارةِ تخطيط القلب و المتمثله بضوضاءَ التذبذب العالي و ضوضاءَ التذبذب الواطئ. المحاكاة مُؤَدّية بأستخدام ال ضوضاءَ التذبذب العالي و ضوضاءَ التذبذب الواطئ َالمستعملهْ في هذه الدراسةِ حُمّلتْ مِنْ الإنترنتِ ، وبعد ذلك عملية التَرْشيح بإستعمال استجابة الحافز المحدود الذي صوّرَ نَتائِجَ افضل مِنْ مرشحاتِ استجابة الحافز اللانهائي.


Article
COMPUTER-BASED ECG SIGNAL ANALYSIS AND MONITORING SYSTEM
تحليل أشارة التخطيط الكهربائي للقلب المعتمد على الحاسوب ونظام المراقبة

Authors: Nasser N. Khamiss Al-Ani نصر نافع خميس العـاني --- Hadeel Kassim Al-Jobouri هـديـل قـاسم وادي الجـبـوري
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2008 Volume: 4 Issue: 3 Pages: 120-127
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This paper deals with the design and implementation of an ECG system. The proposed system gives a new concept of ECG signal manipulation, storing, and editing. It consists mainly of hardware circuits and the related software. The hardware includes the circuits of ECG signals capturing, and system interfaces. The software is written using Visual Basic languages, to perform the task of identification of the ECG signal. The main advantage of the system is to provide a reported ECG recording on a personal computer, so that it can be stored and processed at any time as required. This system was tested for different ECG signals, some of them are abnormal and the other is normal, and the results show that the system has a good quality of diagnosis identification.

يتناول هذا البحث تصميم وتنفيذ منظومة المُخطَط الكهربائي للقلب. المنظومة المعروضة تعطي مفهوم جديد للتعامل مع أشارة المُخطَط الكهربائي للقلب, خزنها, و تحريرها. وهو يتألف بصورة رئيسية من دوائر الاجزاء المادية والبرمجيات المتعلقة. الاجزاء المادية تتضمن دوائر تجميع أشارات المُخطَط الكهربائي للقلب, ومنظومة ألربط التبادلي. والبرمجيات قد كتبت بأستخدام لغة الـ Visual Basic,لتنفيذ مهمة تنفيذ أشارة المُخطَط الكهربائي للقلب. تكمن أهمية ألمنظومة الاساسية في القدرة على تسجيل تقرير للمُخطَط الكهربائي للقلب على الحاسوب ألشخصي, حيث يمكن خزن المعلومات بعد أجراء القياسات و معالجتها في أي وقت متى ما برزت الحاجة الى ذلك. هذه المنظومة قد أختبرت لمختلف أشارات المُخطَط الكهربائي للقلب, البعض منها هي حالات غير طبيعية والبعض الاخر حالات طبيعية, وأظهرت هذه النتائج أن المنظومة لها خاصية جيدة في تحديد المشكلة.


Article
Feature Extraction and Classification for ECG signals Processing based on Stationary Multiwavelet Transform and Artificial Neural Network
أستخلاص الميزّات والخواص و تصنيفها من اشارة القلب بلاعتماد على الشبكة المتعددة المويجات المستقرة و الشبكه العصبية الصناعية

Author: Zahraa K. Taha زهراء خضير طه
Journal: AL-MANSOUR JOURNAL مجلة المنصور ISSN: 18196489 Year: 2018 Issue: 29 Pages: 85-101
Publisher: Private Mansour college كلية المنصور الاهلية

Loading...
Loading...
Abstract

This paper proposes an algorithm that uses mix of Stationary Multiwavelet Transform and Artificial Neural Network (ANN) algorithm for classification of Electrocardiograph (ECG) signals. The MIT-BIH arrhythmia database is used to measure the performance of the suggested method and compare the results with conventional techniques. The Stationary Multiwavelet Transform (SMWT) and the Minimum Average Maximum strategy (MAM) is suggested to calculate the useful features of the signal before utilizing ANN algorithm for classification. Since SMWT is a translation invariant, therefore, it enhances the classification performance and reduces mean square error (MSE). Repeated Row Processing exists in this scheme to make it more suitable for feature extraction compared with Stationary Wavelet Transform (SWT), Multiwavelet Transform (MWT) and Principle Component Analysis (PCA). SMWT and MAM reduce dimensional space and decrease the complexity of classification circuit. ECG signal is classified using ANN. Finally, the results of the proposed method are realistic compared with SWT-ANN, MWT-ANN, and PCA-ANN. The obtained results emphasize the excellence of the presented algorithm than the traditional techniques. The SMWT-ANN achieves classification accuracy of 100% and mean square error of 〖1.4*10〗^(-3).

تم في هذا البحث الدمج بين الشبكة المتعددة المويجات المستقرة و الشبكه العصبية الصناعية لغرض تصنيف اشارة القلب. ان قاعدة البيانات MIT-BIH قد استخدمت لقياس أداء الطريقة المقترحة ومقارنة النتيجة مع التقنيات التقليدية. ان الطرق (SMWT) و (MAM) تم اقتراحها لاستخلاص الميزّات والخواص من الاشارة قبل تصنيفها بواسطة ANN. بما ان SMWT لها خاصية عدم التغير مع الزحف فأن هذا يعزز من أداء عملية التصنيف ويقلل من الخطأ. أن تكرار معالجة الأسطر الموجودة في هذا المخطط جعل الاسلوب المستخدم أكثر ملاءمة لأستخراج الميزات مقارنة مع SWT, MWT وPCA. ان الطرق (SMWT) و (MAM) تقلل من ابعاد الإشارة وتقلل من تعقيد دائرة التصنيف. أخيراً ان نتائج الطريقة المقترحة هي واقعية مقارنة مع SWT-ANN, MWT-ANNو PCA-ANN. النتائج التي تم الحصول عليها تؤكد تفوق الخوارزمية المقترحة على الاساليب التقليدية.SMWT-ANN حققت دقة تصنيف 100% و معدل خطأ بمقدار 0.0014.


Article
Comparison of the RLS and LMS Algorithms to Remove Power Line Interference Noise from ECG Signal
المقارنه بين خوارزمية (اقل معدل تربيع) و خوارزمية (تكرار اقل تربيع)لازالة ضوضاء قدرة الخط ألتداخلي من اشارة تخطيط القلب

Author: Noor K. Muhsin نور كمال محسن
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2010 Volume: 6 Issue: 2 Pages: 51-61
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Biomedical signal such as ECG is extremely important in the diagnosis of patients and is commonly recorded with a noise. Many different kinds of noise exist in biomedical environment such as Power Line Interference Noise (PLIN). Adaptive filtering is selected to contend with these defects, the adaptive filters can adjust the filter coefficient with the given filter order. The objectives of this paper are: first an application of the Least Mean Square (LMS) algorithm, Second is an application of the Recursive Least Square (RLS) algorithm to remove the PLIN. The LMS and RLS algorithms of the adaptive filter were proposed to adapt the filter order and the filter coefficients simultaneously, the performance of existing LMS algorithm of the adaptive filters cause completely removing of the PLIN comparing with the RLS algorithm that reducing the noise level only.

الاشارات الطبيه مثل اشارة تخطيط القلب مهمه جدا في تشخيص المرضى و عادة تسجل معها ضوضاء. هناك الكثير من انواع الضوضاء التي تسجل في البيئه الطبيه مثل ضوضاء قدرة الخط ألتداخلي. المرشحات المتكيفه اختيرت للتغلب على هذه العيوب، المرشحات المتكيفه بامكانها تغيير معاملات المرشح مع اعطاء رتبة المرشح. المهمه الاولى في هذا البحث هو تطبيق خوارزمية (اقل معدل تربيع)، المهمه الثانيه في هذا البحث هو تطبيق خوارزمية (تكرار اقل تربيع) لازالة ضوضاء قدرة الخط ألتداخلي. خوارزمية (اقل معدل تربيع) و خوارزمية (تكرار اقل تربيع) للمرشحات المتكيفه اختيرت لتهىء رتبة المرشح و عوامله بشكل متزامن. اداء خوارزمية (اقل معدل تربيع) تؤدي الى ازالة ضوضاء قدرة الخط ألتداخلي نهائيا مقارنة بخوارزمية (تكرار اقل تربيع) التي تؤدي الى تقليل مستواه فقط.


Article
Comparative study of Equine Chorionic Gonadotropine and Licorice Extract (Glycyrrhiza Glabra) on the some Reproductive Traits in Awassi Ram Lambs
دراسة مقارنة لتأثير محرضات القند المشيمية للفرس (eCG) و مستخلص عرق السوس على بعض الصفات التكاثرية لذكور الحملان العواسية

Loading...
Loading...
Abstract

This study was conducted to find out the effect of licorice extract and eCG on the some reproductive traits in Awassi ram lambs. This study was conducted on State Board for Agriculture Researches, Animal Researches station. Twenty four Awassi ram lambs at the age of 67-77 days were randomly divided into four groups according to the lambing date as follow: Group (A) was injected with eCG 300 I.U /lamb/week. Group (B) was treated with licorice 300 mg/kg B.W/week orally. Group(C) also was treated licorice 400 mg/kg B.W/week orally. Group (D) were kept as a control group. Testes measurements were taken at the 12th week of the study period. The level of testosterone hormone was measured at monthly intervals. Age of puberty, number of mounts/successful ejaculation were recorded. Testes measurements length and depth of right and left of animal in groups B and C showed significantly (P< 0.05) higher values than the control and group A. Width of the right and left testes of lambs in all groups did not record significant differences. Circumferences of the testes showed higher (P< 0.05) values in group B compared to other groups. Serum testosterone concentration increased in all animals during the experimental periods but group B and C showed significantly (P< 0.05) higher values than other groups. Age of puberty and sperm production of the lambs in the control group showed significantly (P < 0.05) higher values compared with all groups, but group A recorded significantly (P< 0.05) higher values compared with groups B and C, while groups B and C recorded significantly (P< 0.05) lower age of puberty compared with groups A and control. The number of Mounts/successful ejaculate decreased with progress of age in all groups, while the control group recorded significantly (P< 0.05) higher number than other treated groups. Group B recorded significantly (P< 0.05) lower values than A and C groups.

اجريت هذه الدراسةِ لمعرفة تأثيرِ مستخلصِ عرقِ السوس والـ eCGعلى بعض الصفات التكاثرية في الحملان الذكرية العواسية ، أربع وعشرون من ذكور الحملانِ العواسية بعُمرِ 67-77يوم قُسّمتْ بشكل عشوائي إلى أربع مجموعاتِ طبقاً لوزنِ الجسمِ كالتّالي: مجموعة (A) حُقِنتْ ب300 وحدة دوليةeCG حمل إسبوع. مجموعة (B) عولجتْ بعرقِ سوس 300 ملغمكغم وزن الجسم إسبوع عن طريق الفم. مجموعة (C) أيضاً عولجتْ بعرقَ السوس 400ملغمكغم وزن الجسم إسبوع عن طريق الفم. مجموعة(D) كمجموعة سيطرة. أَخذتَ قياسَات الخصيةِ فيِ الاسبوع الثاني عشر من التجربةَ، اما مستوى هورمونِ التستستيرونِ فقد تم قِياسَهِ كل شهرِ.عمر البلوغ الجنسي وانتاجِ السائل المنويَ وعدد مرات الصعود الصعود الناجح تم قياسها . نَتائِج الدراسة بينت ان : قياسات الخصى (طول وعمق) (اليمين واليسار) في المجموعتانِ B وC َسجلت فروقا احصائية (P <0.05) أعلى مِنْ مجموعةِ A و السيطرةِ بينما لم تسجل باقي ّ المجموعاتِ فروقا هامّةَ. اظهرت المجموعة B قِيَمَ أعلى بشكل حسابي مقارنة بالمجموعاتِ الأخرى. محيط الخصية اظهرَ فروقا احصائية (P <0.05) ْفي المجموعة B مقَارنة بكُلّ المجموعات الأخرى. مستوى هورمونِ التيستوستيرونَ َارتفع في كُلّ الحيواناتِ على طول فترةِ التجربة ومستواه في المجموعة B وC اظهر فروقات احصائيةَّ (P <0.05) مقارنة ْ بالمجموعاتِ الأخرى. عمرَّ البلوغ الجنسي وإنتاج الحيامنَ للحيوانات في مجموعة السيطرة أظهرت فروقات معنوية (P <0.05) مقارنة بكافة المجاميع، لكن المجموعة A سجلت فرق معنوي (P <0.05) مقارنة بمجموعتي (B وC)، بينما سجلت مجموعتي (B وC) فرق َ معنوي <0.05) (P بشكل اقل بعمر البلوغ الجنسي مقَارنةْ بمجموعتي A والسيطرةِ. عدد مرات الصعود الصعود الناجح انخفض بشكل تدريجي مع تقدم العمر في كافة المجاميع، مجموعة السيطرة سجلتَ فروقا معنوية (P <0.05) في العدد مقارنة بكافة المجاميع، بينما سجلت مجموعة B فرق معنويَ (P <0.05) بشكل اقلْ ثم مجموعتي A وC.


Article
Simulation Recording of an ECG, PCG, and PPG for Feature Extractions
تسجيل محاكاة مخطط القلب الكهربائي، مخطط اصوات القلب، مخطط التحجم لأستخراج الخصائص

Authors: Salma A. Ridha سلمى علي رضا --- Israa F. Abdulazez اسراء فائق عبد العزيز --- Noor Kamal Al-Qazzaz نور كمال القزاز
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2014 Volume: 10 Issue: 4 Pages: 81-93
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Recently, the development of the field of biomedical engineering has led to a renewed interest in detection of several events. In this paper a new approach used to detect specific parameter and relations between three biomedical signals that used in clinical diagnosis. These include the phonocardiography (PCG), electrocardiography (ECG) and photoplethysmography (PPG) or sometimes it called the carotid pulse related to the position of electrode.Comparisons between three cases (two normal cases and one abnormal case) are used to indicate the delay that may occurred due to the deficiency of the cardiac muscle or valve in an abnormal case.The results shown that S1 and S2, first and second sound of the heart respectively, can be determined from another signal like ECG. Moreover, the position of QRS complex and the end of T wave could be estimated by using PPG signal.

التطور في مجال هندسة الطب الحياتي الذي حصل مؤخرا، ادى الى تجديد الاهتمام بالكشف عن العديد من الاحداث. في هذا البحث استخدم نهج جديد للكشف عن معطيات و علاقات محددة بين ثلاث من الاشارات الحيوية التي تستخدم في التشخيص و هي: مخطط اصوات القلب، مخطط القلب الكهربائي و مخطط التحجم و الذي يسمى في بعض الاحيان النبضة التاجية المتعلقة بموقع القطب الكهربائي. المقارنة بين هذه الحالات الثلاث ( اثنان منهما حالتان طبيعيتان و الثالثة حالة غير طبيعية) ربما تستخدم في الكشف عن التأخير الذي قد يحدث نتيجة للقصور في العضلة القلبية او صمام قلبي في الحالات غير الطبيعية. النتائج اظهرت ان اصوات القلب (الصوت الاول و الثاني)، من الممكن حسابهما من اشارة اخرى مثل اشارة القلب الكهربائي. كذلك فأن جزء من الاشارة القلبية و نهايتها من الممكن التنبؤ بها عن طريق اشارة التحجم.


Article
Induction of Fertile Estrus in Bitches using Equine Chorionic Gonadotropine (eCG) and Human Chorionic Gonadotropine (hCG)
احداث الشبق الخصب في الكلاب باستخدام هرمون مصل الفرس الحامل والهرمون المشيمي البشري

Author: Talib M. Al-Hamedawi طالب موسى عبدالله الحميداوي
Journal: The Iraqi Journal of Veterinary Medicine المجلة الطبية البيطرية العراقية ISSN: 16095693 Year: 2013 Volume: 37 Issue: 1 Pages: 102-105
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Eighteen (18) anestrous bitches aged 3-6 years were used in this study. They were diagnosed clinically by external and vaginal examination and the bitches were divided randomly into three equal groups (6 bitches). The 1st group were treated I/M with 20 IU eCG / bitch for 6 days with single injection and 150 IU of hCG hormone /Bitch on day 7 . The 2nd group were treated I/M with 30 IU eCG / bitch for 6 days with single injection and 150 IU of hCG hormone /bitch on day 7, and the 3rd group were treated I/M with 40 IU eCG / bitch for 6 days with single injection and 150 IU of hCG hormone /bitch on day 7. Results showed that the number responded (show proestrus bleeding) were 83.3%, 100% and 83, 3% for the 1st,2nd and 3rd group respectively. The mean duration response from the beginning of treatment to onset of proestrus bleeding were 15.23 ± 2.36, 14.83± 2.43 and 14.16 ±2.58 day respectively .1st and 3rd group recorded significantly P<0.01 higher in response to treatment 1st group recorded significantly higher (P<0.01) compared with 2nd and 3rd group in duration of response. The conception rate was 80% (4/5), 83.3%(5/6) and 60%(3/5) in 1st, 2nd and 3rd group respectively were the 1st and 2nd group recorded higher significant compared with 3rd group. The dystocia parturition was appeared 8.4 % (1/12) from total animals, while the percentage of live newborn (whelps) was 29 (76.3%) and dead 9 (23.7%). In conclusion that the using gonadotrophic hormones (eCG and hCG) have an positive effect of induction the estrus on anestrous bitches.

اجريت هذه الدراسة على 18 كلبة عديمة الشبق (سبات جنسي) وقد تم تشخيصها سريريا بواسطة الفحص الخارجي والمهبلي، وقد تم انجاز البحث في كلية الطب البيطري-جامعة بغداد اضافة الى عيادتين بيطريتين في محافظة بغداد وكانت اعمارها تتراوح بين 3-6 سنوات وللفترة بين 2010-2012. تم تقسيم الحيوانات عشوائيا الى 3 مجاميع (ضمت كل مجموعة 6 حيوانات). المجموعة الاولى تم حقنها بهرمون مصل الفرس الحامل. بجرعة مقدارها 20 وحدة دولية/ كلبة في العضل ولفترة 6 ايام اعقبها جرعة واحدة من الهرمون المشيمي الغذائي وبمقدار 150 وحدة دولية/ كلبة في العضلة وذلك في اليوم السابع . اما المجموعة الثانية فقد حقنت بجرعة مقدارها30 وحدة دولية/ كلبة من هرمون مصل الفرس الحامل ولفترة 6 ايام ايضا اعقبها نفس الجرعة من الهرمون المشيمي الغذائي في اليوم السابع ولجرعة واحدة فقط, اما مايخص المجموعة الثالثة فقد تم حقنها ب 40 وحدة دولية/ كلبة من هرمون مصل الفرس الحامل ولفترة 6 ايام اعقبها نفس الجرعة من الهرمون المشيمي الغذائي ولليوم السابع فقط ايضا. وقد اظهرت النتائج ان عدد الحيوانات المستجيبة للعلاج (والتي اظهرت النزف قبل الشبق) هي 83,3% , 100% , 83,3% للمجاميع الاولى والثانية والثالثة على التوالي, فيما كانت الفترة اللازمة للاستجابة من بدء العلاج وحتى ظهور النزف قبل الشبق 15,53±2,36 , 14,83 ±2,43 , 14,16 ±2,58 على التوالي , وقد سجلت المجموعتين الاولى والثالثة فرقا احصائيا وبمستوىP<0.01 مقارنة بالمجموعة الثانية والتي سجلت افضلية على المجموعتين اعلاه فيما يخص نسبة الاستجابة. اما ما يخص فترة الاستجابة فقد سجلت المجموعتين الثانية والثالثة افضلية عما عليه في المجموعة الاولى وبمستوىP<0.01 ايضا. اما معدل الاخصاب فقد سجل نسبة 80% (4/5), 83,3% (5/6) و60% (3/5) للمجاميع الاولى والثانية والثالثة على التوالي وقد سجلت افضلية وبمستوى P<0.01 للمجموعتين الاولى والثانية مقارنة مع المجموعة الثالثة. اما حالات عسر الولادة فقد تم تسجيل نسبة 8,4% (1/12) ولجميع حيوانات المجاميع الثلاثة فيما كانت نسبة المواليد الحية 76,3% (29/38) اما الميتة منها فكانت 23,7 (9/38) . نستنتج من هذه الدراسة انه بالامكان استعمال الهرمونات المحفزة للقند والمتمثلة بهرمون مصل الفرس الحامل والهرمون المشيمي الغذائي له تاثير ايجابي لاحداث الشبق في الكلاب عديمة الشبق (سبات جنسي) وبجرع مختلفة.

Listing 1 - 10 of 10
Sort by
Narrow your search

Resource type

article (10)


Language

Arabic and English (10)


Year
From To Submit

2018 (1)

2014 (1)

2013 (4)

2011 (1)

2010 (2)

More...