research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Experimental Investigation of Using Evaporative Air Cooler for Winter Air-Conditioning in Baghdad
دراسة عملية باستخدام مبردة الهواء التبخيرية لغرض تكييف الهواء شتاءاً في بغداد

Authors: Zainab Hasson Hassan زينب حسون حسن --- Zainab Hassan Hanash زينب حسن حنش
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2012 Volume: 8 Issue: 4 Pages: 62-73
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This paper presents an efficient methodology to design modified evaporative air-cooler for winter air-conditioning in Baghdad city as well as using it for summer air-conditioning by adding a heating process after the humidification process. Laboratory tests were performed on a direct evaporative cooler (DEC) followed by passing the air on hot water through heat exchanger placed in the coolers air duct exit. The tests were conducted on the 2nd of December /2011 when the ambient temperature was 8.1°C and the relative humidity was (68%). The air flow rate is assumed to vary between 0.069 to 0.209 kg/s with constant water flow rate of 0.03 kg/s in the heat exchanger. The performance is reported in terms of effectiveness of DEC, saturation efficiency of DEC, outlet temperature of air and cooling capacity. Heat transfer rate in heat exchanger mode is also estimated. The paper presents the mathematical development of the equations of thermal exchanges through DEC and HE. Prediction of air condition that exits o this system show that the present system could bring the air stream to a comfortable winter zone .

هذا البحث يقدّم نموذج بسيط وفعّال لتطوير مبردة هواء لغرض استخدامها للتدفئة في فصل الشتاء وبما يلائم المناخ في مدينة بغداد، ويتم ذلك بإضافة عملية تسخين بعد عملية الترطيب. تم تصميم وبناء منظومة لهذا الغرض واخذ القراءات المختبرية، حيث تتكون هذه المنظومة من مبردة هواء مرتبطة بمجرى للهواء مثّبت في نهايته مبادل حراري. تم أجراء التجارب في الثاني من شهر كانون الثاني لسنة 2011 حيث كانت درجة حرارة الهواء 8.1°C والرطوبة النسبية 68% ومعدل تدفق الهواء الداخل للمنظومة تتغير بين 0.069 to 0.209 kg/s مع ثبوت تدفق الماء للمبادل الحراري0.03 kg/s . تم الحصول على النتائج على هيئة فعالية مبردة الهواء، كفاءة مبردة الهواء، درجة حرارة الهواء الخارج من المنظومة وسعة التبريد وكذلك تم حساب انتقال الحرارة خلال المبادل الحراري . ان هذا البحث يقدم نموذج رياضي لمعادلات التبادل الحراري خلال مبردة الهواء والمبادل الحراري. على ضوء النتائج التي تم الحصول لظروف الهواء عند خروجه من المنظومة، فقد أثبتت هذه المنظومة فعاليتها وكفاءتها حيث تم الحصول على ظروف مريحة للهواء لفصل الشتاء.


Article
An Experimental Study on the Effect of Shape and Location of Vortex Generators Ahead of a Heat Exchanger
دراسة عملية عن تأثير شكل وموقع مولدات الدوامات عند مدخل المبادل الحراري

Author: Wisam Abed Kattea وسام عبد كاطع
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2012 Volume: 8 Issue: 2 Pages: 12-29
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An experimental study is carried out on the effect of vortex generators (Circular and square) on the flow and heat transfer at variable locations at (X = 0.5, 1.5, 2.5 cm) ahead of a heat exchanger with Reynolds number ranging from 62000< Re < 125000 and heat flux from 3000 ≤ q ≤ 8000 W/m2 .In the experimental investigation, an apparatus is set up to measure the velocity and temperatures around the heat exchanger. The results show that there is an effect for using vortex generators on heat transfer. Also, heat transfer depends on the shape and location. The circular is found to be the best shape for enhancing heat transfer at location [Xm=0.5 cm] distance before heat exchanger is the best location for enhancing heat transfer. The square is the best shape for enhancing heat transfer at location [Xm=2.5 cm] distance before heat exchanger is the best location for enhancing heat transfer.The results of flow over heat exchanger with vortex generators are compared with the flow over heat exchanger without vortex generators. Heat transfer around heat exchanger is enhanced (56%, 50%, 36%) at location (X=0.5, 1.5, 2.5cm) respectively by using circular vortex generators without turbulator and heat transfer around heat exchanger is enhanced (39%, 42%, 51%) at location (X=0.5, 1.5, 2.5cm) respectively by using square shape vortex generators without turbulator.

دراسة عملية أجريت لفحص تأثير مولد الدوامات ( الشبكة الدائرية ، الشبكة المربعة ) على الجريان و انتقال الحرارة عند مواقع (X = 0.5, 1.5, 2.5 cm) قبل مبادل حراري ضمن مدى لرقم رينولد 62000< Re < 125000 و فيض حراري 3000 ≤ q ≤ 8000 W/m2.في الدراسة العملية تم نصب و صيانة جهاز مختبري لقياس السرعة و درجة الحرارة حول المبادل الحراري.أظهرت النتائج أن لوجود مولد الدوامات اثر كبير على تحسين انتقال الحرارة ويعتمد هذا على شكل المولد وموقعهِ. الشبكة الدائرية هي الأفضل لعملية نقل الحرارة عند موقع [Xm=0.5 cm] قبل المبادل الحراري. الشبكة المربعة هي الأفضل لعملية نقل الحرارة عند موقع [Xm=2.5 cm]قبل المبادل الحراري. قورنت النتائج العملية في حالة وجود مولد الدوامات مع عدم وجود مولد الدوامات. أظهرت هذه المقارنة تحسن في انتقال الحرارة حول المبادل الحراري بنسب (56%, 50%, 36%)عند مواقع (X=0.5, 1.5, 2.5cm )على التوالي بأسنخدام مولد الدوامات الدائري الشكل نسبةً الى عدم وجود عوائق جريان،وانتقال الحرارة حول المبادل الحراري يتحسن بنسب (39%, 42%, 51%)عند مواقع (X=0.5, 1.5, 2.5cm ) على التوالي بأسنخدام مولد الدوامات المربع الشكل نسبةً الى عدم وجود عوائق جريان.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic and English (2)


Year
From To Submit

2012 (2)