research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Design Of A solar Dryer Provided With Back And Heating systems And Its Testing In The Drying Of Fishes And meats
تصميم مجفف شمسي مزود بمنظومتي الراجع والتسخين واختباره في تجفيف الاسماك واللحوم

Author: Asaad R. AL-Hilphy Ghyath.H.majeed
Journal: Journal of Basrah Researches (Sciences) مجلة ابحاث البصرة ( العلميات) ISSN: 18172695 Year: 2007 Volume: 33 Issue: 3B Pages: 20-30
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

A solar dryer was designed for fish and meat drying . Its consist of solar collector with ribbed absorbent plate , its dimensions 1*0.5 m2 and drying chamber contains ten beds , plastic pipe that humid air carry to the head of solar collector and small kerosene cooker under drying chamber .The results showed that the solar dryer enable usage in the winter and summer semesters, rainy and cloudy days for drying fishes and meats .The consumption time to drying , drying efficiency , rate of dehydration , drying rate and mean of humidity reducing higher than usage of natural sun drying . And showed the results the drying rate for fish and meat was multi stage for two methods of drying, exception dried fish by natural sun drying. .

تم تصميم مجفف شمسي للاسماك واللحوم سعته 25 كغم يتكون من مجمع شمسي ذي صفيحة امتصاص مضلعة ابعادها 0.5*1 م وغرفة تجفيف تحتوي على عشرة اطباق وانبوب بلاستيكي ينقل الهواء المحمل بالرطوبة الى مقدمة المجمع الشمسي وطباخ نفطي صغير اسفل غرفة التجفيف .اظهرت النتائج امكانية استعمال المجفف الشمسي في فصلي الصيف والشتاء وكذلك في الايام الغائمة والممطرة في تجفيف الاسماك واللحوم . كما ان الزمن المستغرق للتجفيف وكفاءة التجفيف ونسبة استرجاع الماء ومعدل التجفيف ومعدل انخفاض الرطوبة باستعمال ذلك المجفف الشمسي كانت اعلى من تلك عند استعمال التجفيف الشمسي الطبيعي .كما بينت النتائج ان معدل التجفيف للسمك واللحم كان من نوع متعدد المراحل ولكلا طريقتي التجفيف ماعدا السمك في حالة التجفيف الشمسي الطبيعي.


Article
Theoretical and Experimental Study for the Effect of Mass Flow Rate and concentration ratio of PTC Close Type Solar Collector in Kirkuk City
دراسة نظرية وعملية لتأثير كمية التدفق ونسبة التركيز على أداء مجمع شمسي من نوع القطع المكافئ الأسطواني المغلق في مدينة كركوك

Loading...
Loading...
Abstract

Theoretical and experimental study has been used to analysis close type solar collector PTC in south of Kirkuk city in Iraq 43°.53" longitude, 35°.25" width with elevation of 217 m. The mass flow rate of water and concentration ratio are (0.00083, 0.0011, 0.00138, 0.00166 Kg/sec) and (10, 14, 22) respectively. The measurements and calculations were conduct, which lasted for two season winter and summer, from 9AM to 5PM. The experimental study show that the efficiency of PTC in summer increase in winter from (5 - 7)%, the efficiency is increase with increasing of mass flow rate consequently, then the efficiency is a function of mass flow rate. The efficiency of PTC increased with decreasing of concentration ratio. The maximum value of efficiency is 20% in summer decreased to 15% in winter when the mass flow rate 0.00083 Kg/sec with concentration ratio 22 then increase to 33% in summer and 22% in winter at the same concentration ratio with mass flow rate of 0.00166 Kg/sec, also the experimental study show that the efficiency in summer higher than it in winter by about (10 - 15)% is increased with decrease concentration ratio to reach in summer to 27% and 18% in winter when the mass flow rate 0.00083 Kg/sec with concentration ratio 10 while the efficiency is 42% in summer and 29% in winter at maximum mass flow rate of 0.00166 Kg/sec, and the same concentration ratio . The theoretical study has been performed according to ASHRAE 93-1986 (RA-91) for assessment of performance of PTC solar collector. The theoretical results showed that the theoretical efficiency is 50% and increase to reach 63% with increase the mass flow rate from minimum to maximum value when the concentration ratio is constant. The reason of this error because of the necessary assumption are used in ASHRAE 93-1986 (RA-91) such as steady state conditions which are difficult established in solar energy.

أجريت دراسة نظرية وعملية لأداء مجمع شمسي من نوع القطع المكافئ الأسطواني المغلق جنوب مدينة كركوك شمال العراق عند خط طول43º.53˝ وخط عرض 35º.25˝ وأرتفاع 217m فوق مستوى سطح البحر, تم أختيار معدل تدفق كتلي للمائع المستخدم وهو الماء 0.00083, 0.0011, 0.00138, 0.00166 Kg/sec وبنسب تركيز: 10،14 ،22 على التوالي لفصلي الشتاء والصيف، تبدأ القراءات عند الساعة التاسعة صباحاً وتنتهي عند الساعة الخامسة مساءً, أثبتت النتائج أن الكفاءة العملية في فصل الصيف تفوق الكفاءة العملية في فصل الشتاء بمقدار يتراوح من (5-7)% ويبدو واضحا أنها في فصل الصيف تصل ﺇلى أعلى قيمة لها 20% وفي فصل الشتاء 15% عند أقل تدفق كتلي (0.00083 Kg/sec) ونسبة تركيز(22) لتزداد تدريجياً مع زيادة كمية التدفق الكتلي لتصل ﺇلى أعلى قيمة لها 33% في فصل الصيف و 22% في فصل الشتاء عند تدفق كتلي (0.00166 Kg/sec) لنفس نسبة التركيز أعلاه، كما أثبتت النتائج أن الكفاءة العملية في فصل الصيف تفوق الكفاءة العملية لفصل الشتاء بمقدار يتراوح من(10- 15)% لتصل في فصل الصيف ﺇلى أعلى قيمة لها 27% وفي فصل الشتاء 18% عند أقل تدفق ونسبة تركيز(10) وتزداد تدريجياً مع زيادة كمية التدفق الكتلي لتصل ﺇلى أعلى قيمة لها 42% في فصل الصيف 29% في فصل الشتاء عند نسبة التركيز (10). أجريت الدراسة النظرية وفق معيار أشري ASHRAE 93-1986 (RA-91) لتقييم أداء اللاقط الشمسي, أثبتت النتائج النظرية أن الكفاءة النظرية تبدأ بـ 50% وتزداد نسبياً مع زيادة التدفق الكتلي لتصل ﺇلى 63% عند ثبوت نسبة التركيز, والفرق بين الحل النظري والعملي يأتي من عدم تطبيق كافة فرضيات نموذج أشري وذلك لصعوبة تطبيق شروط حالة الأستقرار.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic (2)


Year
From To Submit

2017 (1)

2007 (1)