research centers


Search results: Found 5

Listing 1 - 5 of 5
Sort by

Article
Thermally Developing Forced Convection in a Horizontal Equilateral Triangular Channel
انتقال الح ا ررة بالحمل القسري لجريان متطور ح ا ررياً في قناة أفقية مثلثة متساوية الأضلاع

Authors: Manar Salih Mahdi --- Tahseen Ahmad Tahseen --- Adnan Mohamed Hussein
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2012 Volume: 19 Issue: 3 Pages: 58-67
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

An experimental investigation was carried out to study thermally developing fully developed laminar forced convection in a horizontal equilateral triangular channel where the channel surface was heated uniformly. The channel length was (1.5 m) long and constructed from three plane (100 mm) walls to form the equilateral triangular crosssection. The experiments were conducted for three mass flow rates (1.91×10-3, 2.54×10-3 and 3.03×10-3 kg/s) and four heat fluxes (91, 171, 272 and 406 W/m2). Reynolds number range was (1198  Re 1988). It was found that local Nusselt number increasing as the heat fluxes and the mass flow rate increased. Also it was found that the greatest local Nusselt number value was in the beginning of the channel then it decreased accompanied by growing the thermal boundary layer along the channel. Present experimental results have a good agreement with previous results obtained for similarly configured channels.


Article
Experimental Study ofForced Convection Heat Transfer Porous Media inside a Rectangular Duct atEntrance Region

Authors: Moayed R.Hasan --- SuhadA.Rasheed --- Ali Najeh Mahdi
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2019 Volume: 27 Issue: 1 Pages: 157-210
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

This work presents experimental investigation of flow and heat transfer characteristics for entry length of turbulent flow in a rectangular duct fitted with porous media and air as the working fluid. Rectangular duct (300×30 mm) with a hydraulic diameter (54.54 mm) was subjected to constant heat flux from lower surface (1.5 ×102 –1.8 ×102w/m2) and Reynolds number ranged (3.3x104 up to 4.8x104). Copper mesh inserts (as porous media) with screen diameter (54.5 mm) for vary distance between two adjacent screens of (10 mm), (15 mm) and (20 mm) in the porosity range of (0.98 - 0.99) are considered for experimentation. The effect of porous height ratio (full and partial) are also considered. It is observed that the enhancement of heat transferby using mesh inserts when compared to a plain surface is more by a factor of (2.2) times where the skin fraction coefficient is about (5) times. An Empiricalcorrelation for Nusselt number and friction factor are developed for the mesh inserts from the obtained results.

يعرض هذا العمل بحثًا تجريبيًا عن خصائص التدفق وانتقال الحرارة في منطقة تطور الجريان عندما يكون الجريان مضطربا في قناة مستطيلة محشوة بوسط مسامي وباستخدام الهواء كمائع عامل. عرضت القناة المستطيلة (300 × 30 مم) مع القطر الهيدروليكي (54.54 ملم) إلى تدفق مستمر للحرارة من السطح السفلي (1.5 × 102 - 1.8 × 102 واط/م2) وتراوحت أرقام رينولدز (3.3 × 104 - 4.8 × 104). تم استخدام شبكة نحاسية بقطر (54.4 ملم) كوسط مسامي ولمسافات مختلفة (15,10و20 ملم)للعمل ضمن مدى المسامية (0.99 الى 0.98). اثناء اجراء التجارب العملية، وتم دراسة تاثير نسبة ارتفاع المسامية (كون التعبئة كاملة وجزئية). كما بينت النتائج العملية ان استخدام الوسط المسامي يحسن انتقال الحرارة بمقدار (2.2) مرة مصحوب بزيادة من معامل الاحتكاك بمقدار (5) مرات.تم استنتاج العلاقات الرياضية لقيم عدد نسلت وعامل الاحتكاك في حالة استخدام الشبكة المسامية من النتائج المستحصل عليها.


Article
A Numerical Study on Laminar Free Convection between Vertical Flat Plates with Symmetric Heating
دراسة عددية في التشكيل الطباقي لجريان الحمل الحر لمائع بين صفيحتين عموديتين متناظرة التسخين

Author: Ameer A. Jadoaa
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2012 Volume: 19 Issue: 2 Pages: 37-49
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

The development of free convection in a viscous fluid between heated plates is investigated. The basic governing continuity, momentum, and energy equations are solved numerically by finite difference method. Results are obtained for the variations of Nusselt number, velocity, temperature, and pressure throughout the flow field assuming the fluid to enter the channel with ambient temperature and a flat velocity profile. The flow and heat-transfer characteristics of the channel are studied and a development height established. Heating plate condition is (C.W.T and C.H.F). An correlation equation has been deduced for the average Nusselt number as a function of Rayligt number. A comparison is made between the results of this theoretical investigation and theoretical work of (Bodoia, J.R 1962)[1].

يتضمن هذا البحث التحقيق في دراسة نظرية في تشكيل جريان الحمل الحر في مائع لزج بين صفيحتين عموديتين.بواسطة حل معادلات الأستمرارية, الزخم, ومعادلة الطاقة بأستخدام طريقة الفروقات المحددة وحلها عدديآ. النتائج المكتسبة لتغير رقم نسلت,السرعة, درجة الحرارة, والضغط في كافة أنحاء مجال الجريان . ويفترض أن المائع الداخل الى القناة بدرجة حرارة المحيط ومنحني السرع الأنسيابي. تم دراسة خصائص أنتقال الحرارة والجريان المجرى وصفة سرعة التشكيل ظرف التسخين هي فيض حراري متغير مع ثبوت درجة الحرارة وفيض حراري ثابت مع تغير درجة الحرارة. معادلات تجريبية أستنتجت لمعدل رقم نسلت كدالة لرقم رايلي. أجريت مقارنة بين التحقيق النظري للعمل الحالي والتحقيق النظري لمصدر (Bodoia, J.R 1962)[1].


Article
Laminar Forced Convection of Dusty Air through Porous Media in a Vertical Annulus
الحمل القسري الطباقي لهواء مترب خلال وسط مسامي في محتوى حلقي عمودي

Authors: Manal Hadi salh AL-Hafidh منال هادي الحافظ --- Salman Hameed Obaid سلمان حميد عبيد
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2014 Volume: 20 Issue: 9 Pages: 90-107
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An experimental and numerical study has been carried out to investigate the forced convection heat transfer by clean or dusty air in a two dimensional annulus enclosure filled with porous media (glass beads) between two vertical concentric cylinders. The outer cylinder is of (82 mm) outside diameters and the inner cylinder of (27 mm) outside diameter. Under steady state condition; the inner cylinder surface is maintained at a high temperature by applying a uniform heat flux and the outer cylinder surface at an ambient temperature. The investigation covered values of input power of (6.3, 4.884, 4.04 and 3.26 W), Reynolds number values of (300, 700, 1000, 1500, and 2000) and dust ratio values (density number N) of (2, 4, 6 and 8). A computer program in MATLAB has been built to carry out the numerical solution by writing the governing equation in finite difference method. The local Nusselt number, the average Nusselt number, the contours of temperature field and velocity field were presented to show the flow and heat transfer characteristics. The results show that when clean air flow, the wall temperature gradually increases along the cylinder length in the direction of flow and decrease as Reynolds number increase while it increases with input power. For dusty air flow results show that the wall temperature gradually increases along the axial direction and increase with Reynolds number and with input power, and the maximum reduction in heat transfer will be 30 % for N=8 at Re=2000. Comparison was made between the present experimental and numerical results and it gives good agreement. The experimental and numerical Nusselt number follows the same behavior with a mean deviation of 12%.

أجريت في هذا البحث دراسة عملية ونظرية لإنتقال الطاقة الحرارية بالحمل القسري بواسطة الهواء النقي أو المترب في فجوة حلقية ثنائبة الأبعاد مملؤة بوسط مسامي (كرات زجاجية) بين أسطوانتين عموديتين متحدتي المركز. القطرالخارجي للأسطوانة الخارجية(82mm) والقطر الخارجي للأسطوانة الداخلية (27 mm) . تحت شروط حالة الإستقرار تم حفظ سطح الأسطوانة الداخلية بدرجة حرارية ثابتة وعالية بتسليط فيض حراري منتظم وتم حفظ سطح الأسطوانة الخارجية بدرجة حرارة الجو.شملت الدراسة قيم القدرة المدخلة (6.3, 4.884, 4.04 and 3.26 W) وعدد رينولد Re (300, 700, 1000, 1500, and 2000) وقيم نسب التراب N(2, 4, 6 and 8. تم بناء برنامج بلغة mat lab لتنفيذ الحل العددي باستخدام طريقة الفروق العددية. وتم تمثيل عدد نسلت الموقعي وعدد نسلت المتوسط ومخططات المجال الحراري ومجال السرعة لتوضيح خواص الجريان وانتقال الطاقة الحرارية. أظهرت النتائج في حالة جريان الهواء النقي أن درجة الحرارة تزداد تدريجيا على طول الأسطوانة باتجاه الجريان وتقل بزيادة عدد رينولد بينما تزداد بزيادة القدرة المدخلة. نتائج جريان الهواء المترب بينت أن درجة الحرارة تزداد تدريجيا في الإتجاه المحوري وتزداد بزيادة عدد رينولد و القدرة المدخلة وأن أقصى انخفاض بانتقال الطاقة الحرارية يساوي30 % لقيمة N=8و .Re=2000 قورنت النتائج العملية والنظربة للبحث الحالي وأظهرت توافق جيد .نتائج عدد نسلت العملية والنظرية أظهرت السلوك ذاته بنسبة إنحراف 12%.


Article
An Experimental Study of the Thermal Performance of Solar Air Collector Inclined (75o) on the Horizontal Plane

Author: Hasasn Ali Jurmut
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 3 Pages: 228-235
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In this paper, an experimental study of the thermal performance of the solar air collector manufactured of galvanized iron sheet with dimension 100×120cm, frame width 20cm, has holes 0.5cm arrangement on horizontal and vertical, the collector inclined at an angle (75o) on the horizontal plane. All author faces of the collector (four sides and background) are insulations in order to minimize the thermal losses .All the result recorded in winter season for two different days one of them sunny and the other was cloudy. The result shows the effect of the angle of collector gives more heat to the collector, hence higher outlet temperature, especially in sunny day. Maximum outlet temperature of the collector (35.5o when inlet temperature 18o) and maximum Nusselt number(Nu) at twelve o’clock of the sunny day more than the cloudy day. At the end its high system efficiency and good collector effectiveness.

تمت في هذا البحث دراسة عمليه للأداء الحراري لجهاز مجمع الهواء الشمسي المصنع من صفائح الحديد غبر المغلون وبأبعاد ) 100 × 120 سم ( ، وعرض الإطار 20 سم، وبثقوب 0.5 سم مرتبة افقيا ورأسيا، والمجمع يميل بزاوية (( 75o على المستوى الأفقي. جميع الجوانب الاخرى من الجامع (أربعة جوانب والخلفية) هي معزولة حراريا من أجل تقليل الخسائر الحرارية . جميع القراءات تمت في فصل الشتاء لمدة يومين مختلفين واحد منهم مشمس والآخر كان غائما. واظهرت النتائج تأثير زاوية ميل المجمع بامتصاصه مزيدا من الحرارة ، وبالتالي ارتفاع درجة الحرارة الخارجة، وخاصة في اليوم المشمس اعلى اعظم درجه خارجة من المجمع (35.5 درجه عندما تكون درجة حرارة المحيط 18 درجة مئوية), اعلى (Nu) في الساعة الثانية عشرة من اليوم المشمس أكثر من اليوم الغائم. واخيرا كفاءة عالية وفعالية جيدة للمجمع الشمسي.

Listing 1 - 5 of 5
Sort by
Narrow your search

Resource type

article (5)


Language

English (5)


Year
From To Submit

2019 (1)

2018 (1)

2014 (1)

2012 (2)