Article
AN EXPERIMENTAL STUDY FOR THE EFFECT OF CAPILLARY TUBE DIAMETER ON REFRIGERATOR PERFORMANCE WITH NEW ALTERNATIVE REFRIGERANT MIXTURE TO R134A

Author: Ali K. Al-Sayyab
Journal: KUFA JOURNAL OF ENGINEERING مجلة الكوفة الهندسية ISSN: 25230018 Year: 2018 Volume: 9 Issue: 2 Pages: 31-44
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

In this work, the effect of capillary tube diameter on refrigerator performance is studied for refrigerants R134a, R290, R600a and its mixture which named: RMix1(70%R134a,20%R290,10%R600a), RMix2(70%R134a,10%R290,20%R600a), RMix3.(50%R134a,20%R290,30%R600a), RMix4 (60%R134a,20%R290,20%R600a). The three adopted capillary tubes diameter are 1.4 mm, 1.8 mm and 2.2 mm, named capillary1, capillary2 and capillary3 respectively. The experimental work show that, the refrigerator operates in 2.2 mm capillary tube's diameter with R134a gives the highest COP from other refrigerants with the same diameter, where the performance of refrigerator with capillary tube of 1.4 mm and alternative ozone friendly refrigerant RMix2 give 1.3% COP reduction from base case of R134a .


Article
Adiabatic and Separated Flow of R-22 and R-407C in Capillary Tube
الجریان الادیاباتي المنفصل لمائعي التثلیج R-407Cو R- 22 داخل الانبوب الشعري

Author: Ahmed Abdulnabi Imran
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2009 Volume: 27 Issue: 6 Pages: 1074-1082
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this paper adiabatic flow in capillary tube is analyzed and modeled for R-22 andalternative R-407C. The equations of continuity, energy and pressure drop through acapillary tube are presented. A mathematical model of sub–cooled flow region andtwo–phase flow region is developed. The results of the calculation compared withexperimental data presented in the technical literature will be shown in the presentarticle in order to validate the model developed. This numerical model is capable ofproviding an effective means to analyze capillary tube performance to optimize andcontrol an R – 22 and R – 407C in an air – conditioning systems.

تم في هذا البحث بناء انموذج رياضي للجريان الادياباتي داخل الانبوب الشعري ولمائعي باستخدام معادلات الاستمرارية والطاقة وتمثيل هبوط الضغط خلال ,( R-407C و R- التثليج ( 22 الانبوب الشعري . الانموذج الرياضي يتضمن بناء انموذج لمنطقة الجريان الاحادي الطور السائل وانموذج اخر لمنطقة الجريان الثنائية الطور . تم مقارنة النتائج الحسابية مع النتائج العملية المتوفرة في البحوث السابقة لغرض التحقق من صحة الانموذج وامكانية استخ دامه لتحليل اداء منظومات التثليج الانضغاطية للوصول للامثلية.


Article
EXPERIMENTAL STUDY ON THE EFFECT OF CAPILLARY TUBE GEOMETRY ON THE PERFORMANCE OF VAPOUR COMPRESSION REFRIGERATION SYSTEM
دراسة عملية لبيان تأثير شكل الأنبوب الشعري على معامل اداء منظومة تثليج دورة انضغاطية

Loading...
Loading...
Abstract

A domestic refrigerator of 5 ft3 capacity is used to study the effect of coiled diameter and pitch distance of a capillary tube. Five capillary tubes of 2 mm in diameter and 1500 mm length each are used, as same as original capillary tube of the refrigerator. The capillary tubes is formed in five shapes, each one has different coil diameter (D) namely 25, 50, 75, 100 and 125 mm in diameter, in addition three distances between each coil (pitch (P)) is tested, namely 6, 8 and 10 mm. The pressure at inlet and outlet of capillary are measured to calculate the cycle COP, as well as the power consumed by the cycle compressor is measured to calculate the mass flow rate of refrigerant. The work show that the coiled diameter of capillary tube affect the cycle COP strongly, as the capillary coiled diameter (D) increases from 25 to 100 mm the cycle COP increases from 2.8 to 3.7 when the cabinet temperature equals to 8oC. The increases of coiled diameter more than 100 mm shows insignificant effect on the cycle COP. While the pitch space of capillary tube coiled shows minor effect on the cycle COP. Moreover, to the mass flow rate of refrigerant increases with approximately ranges from 1.2-2.7 g⁄s as the capillary coiled diameter increases from 25 to 125 mm when the cabinet temperature equals to 8o C. Also; there are directly proportional between the temperature of evaporator cabinet from 2-8 o C with mass flow rate of refrigerant from 1.9-2.4g⁄s when capillary coiled diameter 100 mm.

تم دراسة تأثير قطر لفة الأنبوب الشعري وكذلك الخطوة بين لفة وأخرى على معامل إداء ثلاجة منزلية سعة 5 قدم ، واستخدمت خمسة أنابيب شعرية قياس كل منها يساوي قياس الأنبوب المستخدم في الثلاجة أصلا، وكان قطر الأنبوب 2 ملم وطول 1500 ملم. شكلت الأنابيب الشعرية للحصول على خمسة أشكال من الأنابيب تختلف بقطر اللفة (D)، حيث تم دراسة خمسة أقطار من اللفات تتراوح من 25 الى 125 ملم بخطوة تساوي 25 ملم. أضافة الى ذلك تم دراسة تأثير المسافة بين لفة وأخرى (P) على معامل أداء الثلاجة وكانت المسافات المدروسة تساوي 6 و 8 و 10 ملم. بينت الدراسة ان قطر اللفة (D) يؤثر بشكل كبير على معامل أداء الثلاجة حيث لوحظ زيادة في معامل أداء الثلاجة من 2,8 الى 3,7 عند زيادة قطر اللفة من 25 الى 100 ملم عندما كانت درجة حرارة المقصورة 8 درجة مئوية ، في حين ان زيادة قطر اللفة اكبر من 100 ملم لا يؤثر بشكل كبير على معامل الأداء. ولوحظ تاثير بسيط على معامل اداء الثلاجة عند تغيير المسافة (P) بين لفة وأخرى. أضافه الى ذلك حصلت زيادة في المعدل التدفق الكتلي بمعدلات تقريبية من 1.2-2.7 غمثانية لمائع التثليج عند زيادة قطر اللفة من 25 الى125 ملم عندما كانت درجة حرارة المقصورة 8 درجة مئوية. ايضا لوحظ وجود علاقة طردية بين درجة حرارة مقصورة التبريد من 2-8 درجة مؤوية مع معدل التدفق الكتلي لوسيط التبريد من1.9-2.4 غمثانية عند كان قطر اللفة 100ملم.


Article
Numerical Study of Refrigerant Flow in Capillary Tube Using Refrigerant (R134a)(English))
دراسة عددية لجريان مائع التثليج في الأنبوبة الشعرية باستخدام مائع التثليج (R134a)

Authors: Dr. Amir S. DawoodAss د. أمير سلطان داؤود --- Salim Ibrahim Hasan سالم إبراهيم حسن
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2013 Volume: 21 Issue: 1 Pages: 1-19
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Abstract The present research aims at buildingof a mathematical model using (Engineering Equation Solver) (EES) software to analyze the flow of the refrigerant R134a into two configurations of adiabatic capillary tubes (straight and helical coiled tubes) which are used widely in a household refrigerator, freezer and water cooler. The governing equations which depend on the conservation of mass, momentum, and energy have been coded in order to calculate the length of the single-phase flow region. Moreover, the two-phase regionhasbeen divided numerically depending on homogenous flow assumption after determining the boundary conditions and calculating the physical variables at each point of the numerical divisions by using successive substitution method using iteration loops. Finite difference scheme, the length of thetwo-phase region and the total length for the capillary tube have also been determined. The results show that the behavior of the flow is similar for both forms with regard to the distribution of variables (pressure and temperature drop, dryness fraction, velocity and entropy) over the whole length , while the helical coiled tube length for all cases is shorter than the straight tube at the same conditions. The main parameters that affect the size of capillary tube and the behavior of refrigerant through it have been shown. The tube length increased with the increase of (condenser temperature, degree of sub-cooling and tube diameter) and decreased with the increase of mass flow rate and roughness. The helical tube length increased by increasing coil diameter and coil pitch . The results of the present study agree with the experimental data of previous works with error not exceeding ±10% .Keywords : Adiabatic capillary tube, Household refrigerators, R134a, EES, Helical, Two-phase flow.

الخلاصة يتضمن البحث الحالي بناء أنموذج رياضياتي لتحليل جريان مائع التثليج R134a في شكلين من الأنابيب الشعرية الأديباتية (المستقيمة والملفوفة بشكل لولبي) المستخدمة بشكل واسع في الثلاجات والمجمدات وبرادات الماء المنزلية باستخدام برنامج حل المعادلات الهندسية (EES). لقد تمت برمجة المعادلات الحاكمة المعتمدة على معادلات حفظ الكتلة والطاقة والزخم, لحساب طول المجال أحادي الطور ومن ثم تقسيم المجال ثنائي الطور عددياً بالاعتماد على فرضية الجريان المتجانس بعد حساب الظروف المحددة وحساب المتغيرات الفيزياوية في كل نقطة من التقسيم العددي بطريقة التعويض المتعاقب وذلك بعمل حلقات تكرارية, وحساب طول المجال الثنائي الطور بطريقة الفرق المحدد وبعدها تم حساب الطول الكلي للأنبوب . تبين من النتائج أن سلوك الجريان متشابه في كلا الشكلين من حيث توزيع المتغيرات (انحدار الضغط ودرجة الحرارة ونوعية البخار والسرعة والإنتروبي) على طول الأنبوب . لكن طول الأنبوب الملفوف يكون في جميع الحالات أقصر من طول الأنبوب المستقيم عندما تكون المعالم الأخرى ثابتة. وتم توضيح المعالم الرئيسية التي تؤثر على اختيار الحجم المناسب للأنبوب وعلى سلوك جريان المائع خلاله . وبينت النتائج أن طول الأنبوب يزداد بزيادة كل من (درجة حرارة المكثف ودرجة التبريد الدوني وقطر الأنبوب) ويقل بزيادة (معدل جريان الكتلة وخشونة السطح الداخلي للأنبوب) وكذلك يزداد بزيادة (قطر اللفة وخطوة اللفة). وأظهرت نتائج الدراسة الحالية توافقاً جيداً بالمقارنة مع البيانات التجريبية في الدراسات السابقة وبنسبة خطأ لاتتجاوز ±10% .


Article
Experimental Investigation Effect of Capillary Tube Number on Window Type Air Conditioning Unit Performance
دراسة عملية لتأثير عدد الأنابيب الشعرية على أداء مكييف هواء جداري

Author: Ali Khalid Shaker Al-Sayyab
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2018 Volume: 16 Issue: 1 Pages: 333-341
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

Capillary tubes are widely used in refrigerating and air conditioning units. It has no moving part however, a capillary tube is less expensive and generally performs nearly as well. In this work, the effect of capillary tube numbers on air conditioning system performance is studied for refrigerant R22. The study was adopted with the five capillary tubes at same diameter of 2.2 mm and length of 0.6 m. The experimental work shows that, the air conditioning operates with three capillary tubes gives highest COP from other of the same diameter with 14% increasing from base case of two capillary tubes, where the performance of the air conditioning that operates with one capillary tube gives the lowest COP from other.

تستخدم ألأنابيب الشعرية على نطاق واسع في وحدات التبريد وتكييف الهواء. تمتاز بعدم وجود اي جزء متحرك ويعتبر ألأنبوب الشعري أقل تكلفة .في هذا العمل، تم دراسة تأثير عدد ألأنابيب الشعرية على أداء منظومة تكييف هواء جدارية تعمل بالمائع R22. واعتمدت في هذه الدراسة خمسة أنابيب شعرية ذات قطر 2.2 ملم وطول 0.6 متر. اظهر الجانب العملي أن مكييف الهواء الذي يعمل مع ثلاثة أنابيب شعرية يعطي أعلى معامل اداء من غيرها لنفس القطر مع زيادة 14٪ عن حالة الاساسية (انبوبين شعريين )، كذلك مكييف الهواء الذي يعمل مع أنبوب شعري واحد يعطي أدنى معامل اداء.


Article
The Effect of the Capillary Tube Coil Number on the Refrigeration System Performance
تأثير عدد لفات الأنبوب الشعري على أداء منظومة التثليج الأنضغاطية

Author: Thamir K. Salim
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2012 Volume: 19 Issue: 2 Pages: 18-29
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

The capillary tube performance for (R134a) is experimentally investigated. The experimental setup is a real vapor compression refrigeration system. All properties of the refrigeration system are measured for various mass flow rate from (13 – 23 kg/hr) and capillary tube coil number (0-4) with fixed length (150 cm) and capillary diameter (2.5mm). The results showed that the theoretical compression power increases by (65.8 %) as the condenser temperature increases by (2.71%), also the theoretical compression power decreases by (10.3 %) as the capillary tube coil number increases. The study shows also that the cooling capacity increases by (65.3%) as the evaporator temperature increases by (8.4 %), and the cooling capacity increases by (1.6%)as the capillary tube coil number increases in the range (0-4). The coefficient of performance decreases by (43.4 %), as the mass flow rate increases by (76.9%), also the coefficient of performance increases by (13.51 %) as the capillary tube coil number increases in the range (0-4).Through this study, it was found that the best coil number in refrigeration cycle at the lowest mass flow rate (13 Kg/hr) and at high mass flow rate (23 Kg/hr) is (coil number = 4), this will give the highest performance, cooling capacity and lowest theoretical compression power. An experimental relationship has been adopted between the coefficients of performance (COP) against .خلال هذه الدراسةِ وُجِد أن أفضل عددِ لفات في دورةِ التبريدِ عند اقل معدل تدفق (13 kg /hr) و أعلى معدل تدفق (23 Kg /hr) هو (عدد اللفات = 4)، والتي أعطت أعلى أداء وسعة تبريد واقل قدرة انضغاط نظرية.من هذه الدراسة استنبطت علاقة تجريبية بين معامل الأداء (COP) يقابل

تم دراسة أداء الأنبوب الشعري عمليا ل(R134a). إن معدات العمل التجريبية هي عبارة عن منظومة التثليج الحقيقية للانضغاط البخار. جميع خواص المنظومة تم قياسها لمعدلات تدفق مختلفة (13 – 23 kg/hr) وعدد لفاتِ الأنبوب الشعريِ (0-4) مع طولِ ثابتِ مقداره (150 سم) وقطر الأنبوب الشعري (2.5 ملم). بينت النَتائِجَ بأنّ قدرة الانضغاط النظرية تزداد بمقدار (65.8 %) مع زيادة درجاتَ حرارة المكثفَ بمقدار (2.71 %)، كذلك تقل قدرة الانضغاط النظرية بمقدار(10.3 %) مع زيادة عددَ لفات الأنبوب الشعريِ. كما بينت نتائج الدراسةَ أيضاً بأنّ سعة التَبريد تزدادُ بمقدار (65.3 %) مع زيادة درجات حرارة المبخّرَ بمقدار (8.4 %)، وكذلك تَزِداد سعة التَبريد بمقدار(1.6 %)مع زيادة عدد لفات الأنبوب الشعريِ للمدى (0-4).إن معامل الأداءِ يقل بمقدار(43.4 %)، مع زيادة معدل التدفق الكتلي بمقدار (76.9 %)، وكذلك يزدادُ معامل الأداء بمقدار (13.51 %) مع زيادة عددَ لفات الأنبوب الشعريِ للمدى (0-4).


Article
Identification of RBC and WBC Count in Human Blood Using ARM Based Instrumentation

Authors: B.Dodda Basavanagoud --- Dr. K Padma Priya
Journal: Iraqi Journal for Electrical And Electronic Engineering المجلة العراقية للهندسة الكهربائية والالكترونية ISSN: 18145892 Year: 2015 Volume: 11 Issue: 1 Pages: 145-150
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

The rapid growth in microelectronics and crunching RISC in the field of bio-medical sciencesincorporated of soft tools to diagnose various parameters of human fluids. Conventional method of blood sampleanalysis makes use of laboratory technique of titration, which is operator-dependent and results in lot of errorsdepending on the skill of the technician. In order to eliminate the human errors involved in the conventional method,in this paper an attempt has been made to present a capillary centrifuge technique driven by high speed DC motor fedby Morgan chopper and controlled by powerful ARM processor. It results in accurate analysis of the blood samples.The various techniques involved in accurate sensing of speed using timer and generation of firing pulses to thyristorin the Morgan chopper is judiciously achieved. This paper clearly brings out the advantages of the proposed bloodmeasurement technique which effectively gives blood analysis faster and at a low cost.


Article
Tuneable Fiber Bragg Grating for Magnetic Field Sensor

Authors: Farah S. Al-Thahaby --- Anwaar A. Al-Dergazly
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2017 Volume: 20 Issue: 5 Pages: 1112-1123
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

In this work, four fiber Bragg gratings are fabricated by infiltration different volumes of liquids (star line Glass Mechanix optical adhesive material, olive oil diluted with ethanol) into the hollow core photonic crystal fibers (HC19-1550 (Thorlab Company)). The amplitude splitting interferometric technique with a high resolution specially designed translation stage was used for the fabrication process. This stage is capable of moving the fibers in micrometer resolution steps. The fabrication was carried out using blue laser operated at wavelength of 405 nm. The infiltrated four photonic crystal fibers were exposed to the blue laser beam of 405 nm forming periodic fringes for Bragg grating generation. These fringes were generated from the interference of two splitted laser beams. All fabricated fibers have the same Bragg length of 3.8 cm and average gratings periods of 0.224 μm. The four fibers were analyzed by an optical microscope which displayed the areas that were cured using blue laser. The fabricated fibers also were tested by putting laser beam at one end of the fiber and determining the transmittance at the other fiber end by optical signal analyzer (Thorlabs-CCS200). The resulted Bragg grating fibers have 653.3 nm Bragg reflected wavelength. The results also showed that fiber with higher volume of olive oil has the highest reflection peak about 96.09647 % with the greatest FWHM (full width at a half maximum) about 0.74 nm.In addition, three of the fabricated fibers (B, C and D) that contained olive oil were prepared for testing magnetic field sensor. The results show that all the fibers shifted to near infrared range. The results also showed that fiber with higher concentration of olive oil has the greatest magnetic wavelength shift about 653.4 nm, the highest fiber sensitivity about 0.000494623656 nm/ Gauss, the highest reflection peak about 96.91827 %, and the greatest FWHM about 0.98 nm.

تم في ھذا البحث تصنیع أربعة ألیاف براك المحززة وذلك بحقنھا بمختلف الاحجام من السوائل (المادة الصمغیة البصریةزیت الزیتون مذاب مع الایثانول) بداخل الجوف لتلك الالیاف البلوریة الفوتونیة. تقنیة تداخل تقسیم السعة مع منصة ،Glass Mechanixانتقالیة مصممة خصیصا وبدقة عالیة أستخدمت في عملیة التصنیع. التصنیع تم بأستخدام لیزر أزرق یعمل عند الطول الموجي 405 نانومتر. الألیاف البلوریة الفوتونیة الأربعة المحقونة تم تعریضھا لأشعة اللیزر الأزرق ذو الطول الوجي 405 نانو متر مُكونة اھدابا متكررةبشكل دوري لتولید حزوز براك. ھذه الأھداب تولدت من تداخل شعاعي اللیزر الأزرق المنقسمین ذوي الطول الموجي 405 نانو متر. طولالبراك المصنع للألیاف یساوي 3.8 سم و معدل فترة الحزوز تساوي 0,224 مایكرو متر. الألیاف الأربعة تم تحلیلھا بوساطة المجھرالبصري والذي أظھر المناطق التي تمت معالجتھا بأستعمال اللیزر الأزرق. الألیاف المصنعة تم فحصھا أیضا عن طریق وضع لیزر عند(Thorlabs-CCS احدى نھایتي اللیف وقیاس النفاذیة عند النھایة الأخرى بأستخدام مُحلل الأشارة البصریة ( 200 . ألیاف براك المحززةصُنعت عند الطول الموجي لبراك 653.3 نانو متر. وكذلك أظھرت النتائج أن اللیف ذي الحجم الأعلى من زیت الزیتون یمتلك أعلى قمةأنعكاسیة حوالي 96,09647 % نانو متر و أكبر عرض كامل عند الحد الأعلى للمنتصف حوالي 0,74 نانو متر.والتي تحتوي على زیت الزیتون تم فحصھا كمُتحسس للمجال PCF (B, C, and D) بالأضافة، ثلاثة من الألیاف المصنعةالمغناطیسي. أظھرت النتائج بأن كل الألیاف تتحرك نحو الأشعة تحت الحمراء القریبة. وكذلك أظھرت النتائج بأن اللیف ذي الحجم الأعلىمن زیت الزیتون یمتلك أعلى تحسس مغناطیسي في الطول الموجي حوالي 653.4 نانو متر، أعلى الألیاف حساسیة بمقدار0.000494623656 نانو متر جاوس، أعلى قمة أنعكاسیة حوالي 96,91827 % نانو متر و أكبر عرض كامل عند الحد الأعلىللمنتصف حوالي 0,98 نانو متر.