research centers


Search results: Found 3

Listing 1 - 3 of 3
Sort by

Article
Electrical, thermal and optical characteristicsof plasma torch
تشخيص شعلة البلازما كهربائيا وحراريا وبصريا

Loading...
Loading...
Abstract

Non thermal argon plasma needle at atmospheric pressure was constructed. The experimental set up was based on simple and low cost electric components that generate electrical field sufficiently high at the electrodes to ionize various gases which flow at atmospheric pressure. A high AC power supply was used with 9.6kV peak to peak and 33kHz frequency. The plasma was generated using twoelectrodes. The voltage and current discharge waveform were measured. The temperature of Ar gas plasma jet at different gas flow rate and distances from the plasma electrode was also recorded.It was found that the temperature increased with increasing frequency to reach the maximum value at 15 kHz, and that the current leading the voltage, which demonstrates the capacitive character of the discharge.The electron temperature was measured at about 0.61 eV, and we calculated the electron number density to be 4.38×1015 cm-3.

تم توليد ابرة بلازما الاركون غير الحرارية وتحت الضغط الجوي. باستعمال مكونات الكترونية بسيطة وواطئة الكلفة. لها القدرة على توليد مجال كهربائي عالي عند الاقطاب يكفي لتاين الغازات المختلفة والمتدفقة عند الضغط الجوي. ولدت البلازما التي تم دراستها بفولتية متناوبة عند الاقطاب 9.6 كيلو فولت من القمة الى القمة, وتردد المجال المسلط 33 كيلو هرتز. قدم هذا العمل معلومات عن قياس الفولتية والتيار اللذان استعملا في توليد البلازما. كذلك تم قياس درجة حرارة الغاز (Ar) الاركون لابرة البلازما المتدفق بمستويات تدفق مختلفة من نهاية القطب الكهربائي. وجدت أن درجة الحرارة أرتفعت بأزدياد التردد للوصول إلى القيمة القصوى15 كيلو هيرتز ويبدا بالانخفاض مرة اخرى, ويمكن ان نرى ان سلوك التيار والفولتية يدل على شكل التفريغ ذو خواص سعوية. كما تم حساب درجة حرارة الالكترون وكانت بحدود 0.61 الكترون فولت, وحساب كثافة عدد الالكترونات وكانت بحدود 4.38×1015سم-3.


Article
The effect of the cold atmospheric plasma on the number of platelets
دراسة تأثير بلازما الضغط الجوي الباردة على عدد الصفائح الدموية

Authors: Ansam Q.Gadhban أنسام قاسم غضبان --- Khalid J. Khalil خالد جمعة خليل --- Hamid H. Murbat حامد حافظ مربط
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2019 Volume: 17 Issue: 41 Pages: 58-66
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This study includes the direct influence of (single & multi) dose of Cold Atmospheric Plasma (CAP) on the no. of platelets for mice for different exposure time (15, 30, 60, and 120) sec. the influence of CAP on mice was measured after 1, 2, 3, 7, and 14 day from exposure.The results obtained in this study indicate that the effect of low doses of CAP on platelets was stimulatory effect in the first few hours from exposure (1day) but the high dose was inhibitory, It was found that after two weeks of exposure that the number of platelets became normal comparable to the control one, and this indicates that plasma effect was removed after this period.

تشمل هذه الدراسة التأثير المباشر للجرعة (المفردة والمتعددة) من الـ CAP على عدد الصفائح الدموية للفئران لفترة التعرض المختلفة (120, 60, 30, 15) ثانية, حيث تم قياس تأثير CAP على الفئران بعد (14, 7, 3, 2, 1) يوم من التعرض.تشير النتائج التي تم الحصول عليها في هذه الدراسة إلى أن تأثير الجرعات المنخفضة من الـ CAP على الصفائح الدموية كان تأثيرًا تحفيزيًا في الساعات الأولى من التعرض (يوماً واحداً) ولكن عند الجرعة العالية كان تثبيطًا، وتبين بعد أسبوعين من التعرض أن عدد أﺻﺑﺣت اﻟﺻﻔﺎﺋﺢ اﻟدموية اصبح طبيعيا ﻣﻘﺎرﻧﺔ ﺑﺎﻟﺳﯾطرة، وھذا ﯾﺷﯾر إﻟﯽ إزاﻟﺔ اﻟﺗﺄﺛﯾر اﻟﺑﻼزﻣﺎ ﺑﻌد ھذه اﻟﻔﺗرة.


Article
Influence of Cold Atmospheric Plasma on Acinetobacter baumannii
دراسة تأثير البلازما الباردة على بكتريا الراكدة البومانية

Authors: Reyam Radi Att ريام راضي عطا --- Halah Al Haideri هاله الحيدري --- Hamid H Murbat حامد مربط
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2019 Volume: 16 Issue: 1 Supplement Pages: 151-161
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A. baumannii is an aerobic gram negative coccobacilli, it is considered multidrug resistance pathogen (MDR) and causes several infections that are difficult to treat. This study is aims to employ physical methods in sterilization and inactivation of A. baumannii, as an alternative way to reduce the using of drugs and antibiotics. Cold Atmospheric Plasma was generated by one electrode at 20KV, 4 power supply and distance between electrode and sample was fixed on 1mm. A. baumannii (ATCC 19704 and HHR1) were exposed to Dielectric Barrier Discharge type of Cold Atmospheric Plasma (DBD-CAP) for several periods of time (15, 30, 45, and 60 sec.) . After sterilization test, several methods were done to analyze the effect of DBD-CAP on bacterial morphology, proteins and DNA. Change in morphology was assessed by cover slid method. Damaged DNA was investigated by PCR technique, and DNA sequencing. The impact of DBD-CAP on the entity of proteins was detected by SDS-PAGE. The observed inactivation of bacterial colony on agar plates has been quantified by measuring the inactivation diameter.The important conclusion that HHR1 more resistance to DBD-CAP than ATCC 17904 because it is more virulence than standard strain; thus, the growth of both strains is largely affected by plasma and this influence is increased by increasing the time of exposure, also the plasma affects the DNA especially on standard strain as it is explained in sequencing result, so it causes more deletion in DNA sequence. In addition, plasma also has been showed to damage proteins and morphology thus, the bacterial cells transform from cocco-bacillus to bacillus.

تهدف هذه الرسالة الى توظيف طرائق فيزيائية في معالجة الراكدة البومانية وذلك لغرض التقليل من استخدام الادوية والعقاقير. تضمنت التجربة تعريض سلالتين من الراكدة البومانية ( السلالة العالمية والسلالة المحلية) الى البلازما الباردة بقدرة 20 كيلو فولت وعلى الاوقات التالية (15 و30 و45 و60) ثانية, ثم بعد ذلك اجريت العديد من الاختبارات لغرض دراسة تأثير البلازما على البروتين والحامض الرايبوزي منقوص الاوكسجين وايضا على الشكل الخارجي, ان تأثير البلازما على نمو البكتريا تم حسابه عن طريق قياس قطر التثبيط. أثبتت النتائج ان قطر التثبيط يزداد بزيادة زمن التعرض الى البلازما ايضا اثبتت ان السلالة المحلية هي اكثر مقاومة الى البلازما من السلالة العالمية.

Listing 1 - 3 of 3
Sort by
Narrow your search

Resource type

article (3)


Language

English (3)


Year
From To Submit

2019 (2)

2015 (1)