research centers


Search results: Found 119

Listing 1 - 10 of 119 << page
of 12
>>
Sort by

Article
Simulations of the initiation and propagation of streamers in electrical discharges inside water at 3 mm length gap
محاكاة حاسوبيه لبدء وانتشار التدفق لتفريغ كهربائي داخل الماء لطول فجوه كهربائية 3 ملم

Authors: Thamir H. Khalaf ثامر حميد خلف --- Duaa A. Uamran دعاء عادل عمران
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2018 Volume: 16 Issue: 36 Pages: 172-180
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This work is devoted to the modeling of streamer discharge, propagation in liquid dielectrics (water) gap using the bubble theory. This of the electrical discharge (streamer) propagating within a dielectric liquid subjected to a divergent electric field, using finite element method (in two dimensions). Solution of Laplace's equation governs the voltage and electric field distributions within the configuration, the electrode configuration a point (pin) - plane configuration, the plasma channels were followed, step to step. The results show that, the electrical discharge (streamer) indicates the breakdown voltage required for a 3mm atmospheric pressure dielectric liquid gap as 13 kV. Also, the electric potential and field distributions shown agreement with the streamer growth, according to the simulation development time.

يخصص هذا العمل باقتراح نموذج تفريغ التدفق، والانتشار في عوازل السائل (الماء) باستخدام نظرية الفقاعة. ان التفريغ الكهربائي (التدفق) داخل السوائل العازلة تخضع للمجال الكهربائي متباين باستخدام طريقة العناصر المحدده (في بعدين). فقد تم حل معادلة لابلاس عدديا لتحديد توزيعات الجهد والمجال الكهربائي في منطقة الحل بين القطبين (الاقطاب الكهربائي على شكل نقطه (ابره) - مستوي) تكوين قنوات البلازمية في الماء في كل خطوه. تبين النتائج, ان فولتية الانهيار المطلوبة لعبور التدفق لفجوه مملوه بالماء بطوله 3 ملم بالضغط الجوي كانت 13 كيلوفولت. ايضا تتفق محاكاة توزيع الجهد والمجال الكهربائية مع نمو التدفق وزمن تطور التدفق.


Article
Microbiological Study of Male’sUrethral Discharge

Author: Waleed I A AL – Obadi
Journal: Al-Kindy College Medical Journal مجلة كلية الطب الكندي ISSN: 18109543 Year: 2007 Volume: 4 Issue: 1 Pages: 40-42
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Objective: To evaluate male patients complaining of urethritis clinically according to the isolated organisms.
Method: A total of 100 male patients attending to of Dermatological and Venereal private clinics for the period April 2003 to November 2003 were included in the study. Urethral swab was obtained from each male for culture and direct immunofluorescence examination was done. Demographic data was obtained, also.
Results: N. gonorrhoea was the predominate cause of infection in 22%. A peak of infection was reported in the second decade of age. Highest rate reported among single males. A significant association was noticed between profuse discharge and infection with gonorrhoea.
Conclusion: This study demonstrated that peak of infection in the second decade of age and among singles. A broad range of causative agents was reported.
Key words: Gonorrhoea, urethral discharge, non gonococcal urethral discharge


Article
Current-Voltage Characteristics of DC Plasma Discharges Employed in Sputtering Techniques
خصائص تيار-جهد لتفريغ البلازما المستمر المستخدم في تقنيات الترذيذ

Authors: Mohammed K. Khalaf --- Oday A. Hammadi --- Firas J. Kadhim
Journal: Iraqi Journal of Applied Physics المجلة العراقية للفيزياء التطبيقية ISSN: 18132065 23091673 Year: 2016 Volume: 12 Issue: 3 Pages: 11-16
Publisher: iraqi society for alternative and renewable energy sources and techniques الجمعية العراقية لمصادر وتقنيات الطاقة البديلة والمستجدة

Loading...
Loading...
Abstract

In this work, the current-voltage characteristics of dc plasma discharges were studied. The current-voltage characteristics of argon gas discharge at different inter-electrode distances and working pressure of 0.7mbar without magnetrons were introduced. Then the variation of discharge current with inter-electrode distance at certain discharge voltages without using magnetron was determined. The current-voltage characteristics of discharge plasma at inter-electrode distance of 4cm without magnetron, with only one magnetron and with dual magnetrons were also determined. The variation of discharge current with inter-electrode distance at certain discharge voltage (400V) for the cases without magnetron, using one magnetron and dual magnetrons were studied. Finally, the discharge current-voltage characteristics for different argon/nitrogen mixtures at total gas pressure of 0.7mbar and inter-electrode distance of 4cm were presented.


Article
Numerical Model for the Study of the Velocity DependenceOf the Ionisation Growth in Gas Discharge Plasma

Author: Noori H.N.Al-Hashimi, Jassim T.Mahdi and Fahmi S. Radhi
Journal: Journal of Basrah Researches (Sciences) مجلة ابحاث البصرة ( العلميات) ISSN: 18172695 Year: 2011 Volume: 37 Issue: 5A Pages: 30-38
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

The influence of the velocity on the development of the ionisation has been investigated for the study-state plasma. The cascade ionisation (represented by a constant ionisation coefficient) was assumed to occur over a finite length of an infinite cylinder and the only loss processes considered over this length were electron diffusion. The calculation has been carried out for an open cylinder by using a two dimensional numerical model. The required cascade ionisation, to sustain a given plasma density, has been calculated as a function of velocity.


Article
Control the deposition uniformity using ring cathode by DC dischargetechnique
التحكم بانتظام الترسيب باستخدام كاثود حلقيفي تقنية التفريغ الكهربائي للتيار المستمر

Authors: Kadhim A. Aadim كاظم عبدالواحد عادم --- Muhammad O. Salman محمد عودة سلمان
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2017 Volume: 15 Issue: 32 Pages: 57-67
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Simulation ofdirect current (DC) discharge plasma using COMSOL Multiphysicssoftware were used to study the uniformity of deposition on anode from DC discharge sputteringusing ring and disc cathodes, then applied it experimentally to make comparison between film thickness distribution with simulation results. Both simulation and experimental results shows that the deposition using copper ring cathode is more uniformity than disc cathode.

تم استخدام برنامج COMSOL Multiphysics لعمل محاكاة لبلازما التفريغ الكهربائي للتيار المستمر لدراسة انتظام الترسيب على الأنود الناتج من عملية الترذيذ بواسطة التفريغ الكهربائي عن طريق استخدام كاثود حلقي واخر دائري, ثم تطبيق ذلك عمليا لعمل مقارنة بين توزيع سمك الغشاء مع نتائج المحاكاة. بينت نتائج المحاكاة والنتائج العملية أن الترسيب باستخدام كاثود حلقي من النحاس أكثر انتظاما من الكاثود الدائري.


Article
Design, Construction and Operation of a Multi-Stage Large-Bore CO2 Laser

Authors: D.N. Raouf --- N.A. Al-Rubaiey --- S.I. Abdul-Latif
Journal: Iraqi Journal of Applied Physics المجلة العراقية للفيزياء التطبيقية ISSN: 18132065 23091673 Year: 2005 Volume: 1 Issue: 1 Pages: 25-29
Publisher: iraqi society for alternative and renewable energy sources and techniques الجمعية العراقية لمصادر وتقنيات الطاقة البديلة والمستجدة

Loading...
Loading...
Abstract

In this work, a CO2 laser system of five discharge stages was designed, constructed and operated with longitudinal electrical discharge and axial gas flow. The system was characterized throughout measuring output laser power as function of output coupler reflectivity, length of discharge tube and cooling water temperature. The maximum output power delivered was 135W at the TEM10 mode.


Article
Comparison the Formation of Spark Corona Discharge between Tap and distilled Waters at Liquid Electrode System
المقارنة بين تكوين التوهج الاهليلي النبضي لماء الحنفية والماء المقطر لمنظومة ذات الاقطاب السائلة

Authors: Falah A-H.Mutlak * فلاح عبد الحسن مطلك --- Fadhil Y. Hadi فاضل يوسف هادي --- Majid H. Dwech ماجد حسين دويج* --- Qusay A. Abbas قصي عدنان عباس
Journal: Baghdad Science Journal مجلة بغداد للعلوم ISSN: 20788665 24117986 Year: 2013 Volume: 10 Issue: 1 Pages: 237-242
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this paper, we studied the spark corona discharge in tap and distillited waters. The results show the shape of cone that generated on the tip of capillary tube is different with conductivity of liquids. The blue glow appears at the end of capillary tube and the drop extends into a cone. In addition, the conducitivity is affected on the relationship between the appearance of the blue glow discharge with the applied voltage. The size of the cone decreases with an increase in applied voltage. The cone diameter at the base of capillary tube oscillates with period approximately 1 Sec. this oscillates in the cone diameters is due to the change distance between the liquid electrode and the surface of liquid. The intensity of spark corona discharge that formed in tap water higher than that formed in distillited water. In addiation, when the applied voltage is 5 KV on distillted water, the drope extends into two cones while in tap water the drop extends into one cone. These contrast between two water types which under test (i.e. tap and distillited waters) is due to the differance in condictivity of water.

في هذا البحث,تم دراسة التفريغ الاهليلي النبضي المتكون في ماء الحنفية والماء المقطر. ان النتائج هذا البحث قد اوضحت بان شكل قطرة الماء المتكونة في نها ية الانبوب الشعرية تتغير مع تغير التوصيلية السائل. و كما لوحظ ظهور توهج ازرق في نهاية الانبوب الشعري وان القطرة الماء المتكونة في نهاية الانبوب تكون على شكل مخروط. وان التوصيلية السائل لها تاثير كبير العلاقة بين ظهور التوهج الازرق و الفولتية المسلطة. و ان حجم المخروط المتكون يقل مع زيادة الفولتية المسلطة. وان قطر المخروط في نهاية الانبوب الشعري يتذبذب بزمن ي مقداره ثانية واحدة. وان هذا التذبذب ينشأ بسبب التغير المسافة بين قطب السائل وسطح السائل. ان شدة التوهج الاهليلي النبضي المتولد في ماء الحنفية يكون اكبر من شدة التوهج المتكون في الماء المقطر. بالاضافة الى ذلك عندما تكون الفولتية المسلطة 5 كيلو فولط في حالة الماء المقطر فان قطرة الماء المتكونة في نهاية الانبوب الشعري ستكون على شكل مخروطين بينما في حالة ماء الحنفية ستكون على شكل مخروط واحد. ان هذا الاختلاف بين كلا نوعين من الماء يعزى الى الاختلاف التوصيلية بين كلا نوعين من الماء.


Article
Characterization of Low-Pressure Argon and Nitrogen Discharge Plasmas Using Electrical Floating Probe Method

Authors: M.A.K. Ahmed --- A.S. Jasim --- K.I. Khaleel
Journal: Iraqi Journal of Applied Physics المجلة العراقية للفيزياء التطبيقية ISSN: 18132065 23091673 Year: 2013 Volume: 9 Issue: 3 Pages: 25-28
Publisher: iraqi society for alternative and renewable energy sources and techniques الجمعية العراقية لمصادر وتقنيات الطاقة البديلة والمستجدة

Loading...
Loading...
Abstract

In this work, a low-pressure dc-discharge plasma is characterized by electrical floating probe method. To get sufficient working conditions for plasma electrical probe, a sweep voltage power supply was built. The plasma generation chamber was used to produce glow-discharge using nitrogen and argon gases at pressures of 0.03, 0.07 and 0.1 mbar. The current-voltage characteristics were performed using plasma probe and some calculations, such as electron temperature, plasma frequency and plasma species density, were carried out. The results obtained from I-V curve showed that electron temperature for argon and nitrogen plasmas was increased by increasing gas pressure.


Article
Effects of Positive Corona Discharge on PH Value of Tap and Distilled Waters in Liquid system

Author: Qusay Adnan Abbas
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2013 Volume: 16 Issue: 4 Pages: 141-144
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

In this paper, the effect of positive corona discharge on the PH values of tap and distilled waters are studied in water liquid system. The photographs of the results show that the shape of water drop that formed in the end of capillary tube is extended into a cone as well as a blue glow appears at the end of capillary tube. The size of cone decreases with increases of applied voltage and because of the change distance between the liquid electrode and the surface of liquid, the cone diameter at the end of capillary tube oscillates with period approximately 1 Sec. In addition, the PH values of both tested waters are constant when the applied voltage is less than 5 KV, while when the exterinal applied voltage is equal to or greater than 5KV, the PH value of both water types are increases rapidly where the tap water shows increases rate larger than that for distilled water.

في هذا البحث، درس تأثير التفريغ الاهليجي الموجب على قيمة PH لماء الحنفية والماء المقطر. ان صور الفوتوغرافية لنتائج البحث تبين بأن شكل قطرة الماء المتكونة في نهاية الانبوب الشعري سوف تكون على شكل مخروط بالاضافة الى ذلك ظهور توهج ازرق اللون في نهاية الانبوب الشعري. وان حجم المخروط المتكون يقل مع زيادة الفولتية الخارجية المسلطة وبسبب كون ان المسافة بين قطب المائع وسطح الماء فأن المخروط المتكون في نهاية الانبوب الشعري سوف يتذبذب بمعدل زمني مقداره ثانية واحدة. وكما لوحظ بان قيم PH لكلا نوعي الماء تحت التجربة تكون ثابتة عندما تكون الفولتية المسلطة اقل من 5 كيلو فولت، بينما تزداد قيم PH بشكل سريع لكلا نوعي الماء المستخدم حيث يكون معدل الزيادة لماء الحنفية اعلى من الماء المقطر عندما تكون الفولطية المسلطة تساوي او اعلى من 5 كيلوفولط.


Article
The influence of magnetic field and cathode dimensions on plasma characteristics in hollow cathode system
تأثير المجال المغناطيسي وأبعاد الكاثود على خصائص البلازما في منظومة الكاثود المجوف

Authors: Baraa Afif براء عفيف مسلم --- Qusay Adnan Abbas قصي عدنان عباس
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2018 Volume: 16 Issue: 38 Pages: 26-34
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Experimental study on the effect of cylindrical hollow cathode, working pressure and magnetic field on spatial glow distribution and the characteristics of plasma produced by dc discharge in Argon gas, were investigated by image analyses for the plume within the plasma. It was found that the emission intensity appears as a periodic structure with many peaks appeared between the electrodes. Increasing the pressure leads to increase the number of intensity peaks finally converted to continuous form at high pressure, especially with applied of magnetic field, i.e. the plasma is more stable with the presence of magnetic field. The emission intensity study of plasma showed that the intensity has a maximum value at 1.07 mbar pressure and decrease with more pressure.

أجريت دراسة تجريبية حول تأثير الكاثود الأسطواني المجوف، ضغط العمل ووجود المجال المغناطيسي، على التوزيع المكاني للتوهج وخصائص التذبذب في البلازما الناتجة عن التفريغ الكهربائي في غاز الأرجون، من خلال تحليل الصور للتوهج داخل البلازما. وقد تبين أن كثافة الانبعاثات تظهر كشكل دوري مع العديد من القمم ظهرت بين القطبين. أدى زيادة الضغط التشغيلي إلى زيادة عدد قمم الشدة ثم تحولها أخيرا إلى شكل مستمر عند الضغط العالي، وخاصة عند استخدام المجال المغناطيسي، أي ان البلازما كانت أكثر استقرارا مع وجود المجال المغناطيسي. وأظهرت دراسة كثافة الانبعاث للبلازما أن لها قيم قصوى عند ضغط 1.07 mbar وتنخفض مع مزيد من الضغط.

Listing 1 - 10 of 119 << page
of 12
>>
Sort by
Narrow your search

Resource type

article (119)


Language

English (119)


Year
From To Submit

2019 (7)

2018 (11)

2017 (13)

2016 (25)

2015 (5)

More...