research centers


Search results: Found 65

Listing 1 - 10 of 65 << page
of 7
>>
Sort by

Article
Prevention of Scale Formation in Heat Exchanger Pipesby Using Magnetic Field

Authors: Jassim M. Al-Kyayyat --- Abbas H. Sulaymon عباس حميد
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2007 Volume: 8 Issue: 4 Pages: 39-44
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The possibility of using the magnetic field technique in prevention of forming scales in heat exchangers pipes using hard water in heat transfer processes, also the studying the effective and controllable parameters on the mechanism of scale formation.The new designed heat exchanger experimental system was used after carrying out the basic process designs of the system. This system was used to study the effect of the temperature (40-90 °C) and water flow rate (0.6-1.2 L/min) on the total hardness with time as a function of precipitation of hardness salts from water and scale formation.Different magnetic field designs in the heat exchanger experimental system were used to study the effect of magnetic field design and strength (200-500 Gauss) on the total hardness with time as a function of precipitation of hardness saltsfrom water and scale formation.


Article
PRESSURE DROP CONSTRAINTS IN SLUDGE DOUBLE-PIPE HEAT EXCHANGER DESIGN
محددات فرق الضغط في تصميم مبادلات الحمأة الحرارية نوع الأنبوب المزدوج

Author: Dr. Amer D. Zmat د. عامر دحام زماط
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2011 Volume: 4 Issue: 1 Pages: 472-482
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

Recent years have witnessed a rapid development in the understanding of heat exchangers design. Those developments have justified the use of a global minimum allowable temperature approach under which the heat transfer area of the heat exchanger is minimized. Values of the allowable pressure drops of streams of exchangers are specified to calculate film heat-transfer coefficients of streams and heat-transfer area. By coupling this with the understanding of what dictates the energy consumption, it is possible to determine the trade-off between the heat exchanger capital cost and energy cost prior to design work. Pressure drop is an important issue in the design of a heat exchanger. Pumps and (or) compressors must be installed to overcome pressure losses when streams flow through heat exchangers. The total cost for a system of pumps and compressors consists of the purchase cost of equipments and the electricity cost to run these equipments. This cost could occupy a significant part of the overall cost for a heat exchanger. Therefore, the pressure drop aspect should be considered together with the costs of heat exchanger area.This paper demonstrates how pressure drop is considered in the context of a sludge double-pipe heat exchanger design. A relationship between heat transfer coefficient and heat exchanger pressure drop was determined and its capital cost implications were assessed.

شهدت السنوات الأخيرة تطور سريع في تصاميم المبادلات الحرارية. تميزت معظمها باستخدامها مفهوم أدنى فرق في درجات الحرارة للحصول على اقل مساحة انتقال حراري. وطبقا لتلك الطريقة يتم تحديد قيم فرق الضغط المقبول لحساب معامل انتقال الحرارة ومساحة الانتقال الحراري من خلال ربط هذه الطريقة مع أسلوب حساب استهلاك الطاقة في المبادلات الحرارية ويمكن إجراء المفاضلة بين كلفة المبادل الحراري وكلفة الطاقة اللازمة لتشغيله قبل مرحلة التصاميم التفصيلية. وحيث أن فرق الضغط في المبادلات الحرارية ينعكس على كلف ملموسة في المبادلات الحرارية تتمثل بكلف المضخات والدافعات وكلف الطاقة اللازمة لتشغيل تلك المضخات والدافعات، فان دراسة تلك الكلف نسبة إلى كلفة المبادل الحراري تعتبر أمر ضروري ومهم.يستعرض هذا البحث كيفية تضمين فرق الضغط في مبادلات الأنبوب المزدوج المستخدم لتسخين الحمأة في أحواض الهضم ضمن مرحلة التصميم من خلال إيجاد علاقة بين معامل انتقال الحرارة وفرق الضغط وتقييم انعكاس ذلك على الكلفة المثالية للمبادل الحراري.


Article
Numerical Study of Heat Transfer Enhancement in Heat Exchanger Using AL2O3 Nanofluids
دراسة عددية لتحسين انتقال الحرارة داخل مبادل حراري باستخدام نانو اوكسيد الالمنيوم-الماء

Author: Hussein Talal Dhaiban حسين طلال ذيبان
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2016 Volume: 22 Issue: 4 Pages: 98-115
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this study, the flow and heat transfer characteristics of Al2O3-water nanofluids for a range of the Reynolds number of 3000, 4500, 6000 and 7500 with a range of volume concentration of 1%, 2%, 3% and 4% are studied numerically. The test rig consists of cold liquid loop, hot liquid loop and the test section which is counter flow double pipe heat exchanger with 1m length. The inner tube is made of smooth copper with diameter of 15mm. The outer tube is made of smooth copper with diameter of 50mm. The hot liquid flows through the outer tube and the cold liquid (or nanofluid) flow through the inner tube. The boundary condition of this study is thermally insulated the outer wall with uniform velocity at (0.2, 0.3, 0.4 and 0.5 m/s) at the cold loop and constant velocity at (0.5 m/s) at the hot loop.The results show that the heat transfer coefficient and Nusselt number increased by increasing Reynolds number and particle concentration. Numerical results indicate that the maximum enhancement in Nusselt number and heat transfer coefficient were 9.5% and 13.5% respectively at Reynolds number of 7100 and particles volume fraction of 4%. Results of nanofluids also showed a good agreement with the available empirical correlation at particles volume fractions of 1%, 2% and 3%, but at volume fractions of 4% a slight deviation is obtained.

تمت عددياً دراسة خواص الجريان وانتقال الحرارة لمائع نانو اوكسيد الالمنيوم-الماء لمدى من عدد رينولدز 3000, 4500, 6000 و 7500 مع مدى من التركيز الحجمي لللدقائق من 1%, 2%, 3% و 4%. يتألف جهاز الاختبار من دورة باردة ودورة حارة مع جريان متعاكس للمائع داخل انبوب مزدوج متحد المركز بطول متر واحد. الانبوب الداخلي مصنوع من النحاس الاملس بقطر يعادل 15 مليمتر. والأنبوب الخارجي مصنوع من النحاس الاملس بقطر يعادل 50 مليمتر. جريان المائع الساخن خلال الانبوب الخارجي وجريان المائع البارد (او النانوي) خلال الانبوب الداخلي. الشروط الحدودية لهذه الدراسة هي السطح الخارجي معزول مع سرع متغيرة (0.2, 0.3 , 0.4 و 0.5)مثا للدورة الباردة وسرعة ثابتة (0.5 )مثا للدورة الساخنة. النتائج تبين ان معامل انتقال الحرارة وعدد نسيلت تزداد بزيادة عدد رينولد ومعامل التركيز الحجمي . والنتائج العددية تمثلت بأعلى نسبة تحسين لعدد نسلت ومعامل انتقال الحرارة ب 9.5% و 13.5% على التوالي عند عدد رينولد 7100 ومعامل التركيز الحجمي للجزيئات 4%.كذلك النتائج بينت توافق جيد مع معادلة عددية عند معامل التركيزالحجمي للجزيئات 1%, 2% و 3% ولكن بمعامل الكسر الحجمي 4% حدث اختلاف بسيط .


Article
Two-pass heat-exchanger performance By programmable method

Author: Saosun Abd AL-Shaheed
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2012 Volume: 10 Issue: 1 Pages: 31-40
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

The goal of heat exchanger design is to relate the inlet and outlet temperatures, the over all heat transfer coefficient, to the rate of heat transfer between the two fluids .The use of programming method can greatly aid in optimizing the design.In this study a programmable method [successive summation method] is developed, applied and presented here using Microsoft Visual Basic (version 6) to determine heat – transfer coefficients and the operating temperatures of a two pass heat exchanger [tube bundle permits a hot gas to pass in a-u- pattern through the exchanger with a shell side contains one – pass cooling water], has replaced the classical log-mean temperature difference , LMTD,method. As many plant heat exchanger operations are not accurately analyzed by this method, due to the correction factors associated with it, which must be obtained experimentally where complete sets of data are rare.

هدف تصميم المبادل الحراري هو إيجاد العلاقة بين درجات حرارة دخول وخروج المائع الساخن والبارد , والمعامل الإجمالي لانتقال الحرارة للمبادل مع معدل انتقال الحرارة بينهما , استخدام البرامج الحاسوبية له فائدة كبيرة في الحصول على التصميم الأمثل. تمت في هذه الدراسة إعداد واستخدام طريقة برمجية للجمع التعاقبي باستعمال برنامج مايكروسوفت البيسك المرئي (الإصدار 6) , لحساب المعامل الإجمالي لانتقال الحرارة ودرجات حرارة دخول وخروج الموائع لمبادل حراري (متقابل الانسياب) يحوي حزمة من الأنابيب ذو مسار على شكل حرف u يحوي الغاز الحار ومسار واحد للاسطوانة تحوي الماء البارد) , بدلاً من (استخدام طريقة المتوسط اللوغارتمي لفرق درجات الحرارة)حيث تعتمد الأخيرة على (معامل التصحيح) الذي يتم تعينيه تجريبياً , والتي تنقصها الدقة لاعتمادها على النتائج العملية .


Article
Natural Convection from Single Finned Tube Immerrsed in a Tilted Enclosure

Authors: Hadi R. Roomi --- Ikhlase M. Fayed
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2007 Volume: 13 Issue: 3 Pages: 1585-1600
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Heat transfer rates of a single horizontal finned tube immersed in water –filled enclosure tilted at 30 degrees are measured .The results serve as a baseline case for a solar water heating system with a heat exchanger immersed in integral collector storage. Tests were made with both adiabatic and uniform heat flux boundary conditions. Natural convection flow in enclosure is interpreted from measured water temperature distributions. Formation of an appropriate temperature difference that drives natural convection is determined .Correlations for the overall heat transfer coefficient in terms of the Nusselt and Rayleigh numbers are reduced to the form Nu = 0.716 Ra^0.247for 2*10^5 <= Ra <= 2*10^7 Based on the diameter of the immersed tube .Comparison the present work results with others gave a good agreement.

قيس معدل انتقال الحرارة من أنبوب منفرد مغمور في ماء داخل مغلف . المغلف مائل عن الأفق بزاوية º 30 . ممكن تمثيل النتائج لمنظومة تسخين بالطاقة الشمسية لمبادل حراري مغمور في مجمع الطاقة الشمسية أجريت الاختبارات لحالة العزل الحراري من جميع الجهات بوجود شروط حدية بثبوت درجة حرارة المائع مرة والحالة الثانية العزل الحراري من جميع الجهات ما عدا السطح العلوي إذ يتعرض لثبوت الفيض الحراري ممكن تمثيل جريان انتقال الحرارة بالحمل الحر داخل المغلف من خلال قياس درجات الحرارة داخله . العلاقة التجريبية لانتقال الحرارة بالحمل الحر ممكن تمثيلها بدلالة عدد نسلت ورقم رايلي من خلال العلاقة التجريبية التالية:Nu=0.716Ra^0.247 for 2×10^5<=Ra<=2×10^7قيست العلاقة على أساس قطر الأنبوب المغمور. قورنت نتائج البحث الحالي مع بحوث سابقة وحصل على توافق جيد.


Article
Experimental and Theoretical Investigation of Micro Pin Fins Heat Exchanger Used in Convective Cooling Application
دراسة عملية ونظرية لمبادل حراري صغير ذو زعانف أبرية يستخدم في تطبيقات التبريد بالحمل

Authors: Auday.A.Abbo --- Mohammed I. Abu-Tabikh --- Kutaeba J. AL-Khishali
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2010 Volume: 28 Issue: 17 Pages: 5581-5602
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Experimental and theoretical investigations of flow and thermal performance of an annular pin fin heat exchangers exposed to constant heat flux have been preformed. A special test rig was designed and built for this purpose. The main test section is an annulus of radius ratio (0.85) containing 10 rows of 1mm diameter pins with 5 pins ineach row. The range of cooling air Reynolds number based on the hydraulic diameter of the channel, is (6774 to 11120). In the Theoretical part the well known Fluent (6.3)package was used for solving the governing equations for flow and Energy equation for heat transfer with RNG k-ε turbulence model. Results showed that the pin fins enhanced the heat transfer by a factor of (1.31 to 1.42) and increased the friction factor by (3 to 4) times compared to the one obtained for smooth annular channel without pins. A Nusselt-Reynolds correlation was obtained from the experimental datavalid in the Reynolds number range studied. Reasonable agreement between the experimental and theoretical results was obtained with average difference (5%) over the Reynolds number range. The overall thermal performance obtained was larger than (1).

تمت دراسة الجريان وانتقال الحرارة عمليا و نظريا في مبادل حراري حلقي ذو زعانف أبرية معرض إلى فيض حراري ثابت. تم تصميم وتنفيذ جهاز مختبري متكامل لهذا الغرض يتضمن مقطع اختبار على شكل قناة حلقية ذات نسبة أنصاف أقطار ( 0.85 ) تحتوي على 10 صفوف من 1 مرتبة بواقع 5 زعانف في كل صف. عدد رينولدز لهواء التبريد تراوح mm زعانف أبرية بقطر لحل المعادلات FLUENT( ضمن المدى ( 6700 إلى 11120 ). تم استخدام تقنية برمجيات ( 6.3 أظهرت النتائج أن .(RNG k-ε) الحاكمة للجريان وانتقال الحرارة مع استخدام نموذج الاضطراب الزعانف الابرية تحسن من انتقال الحرارة بواقع ( 1.31 إلى 1.42 ) وتزيد من معامل الاحتكاك ( 3 إلى 4) مرات بالمقارنة مع قناة حلقية ملساء بدون زعانف. تم الوصول إلى معادلة تجريبية تربط عدد ناسلت مع عدد رينولدز نافذة المفعول ضمن مدى عدد رينولدز المحدد في التجارب. وتم الوصول إلى توافق معقول بين النتائج النظرية والعملية بمعدل فارق بين الاثنين بنسبة (% 5). معامل .( الأداء الحراري الكلي للمبادل كان اكبر من (


Article
Performance Characteristics of Parallel Slip Flow Microchannel Heat Exchanger

Authors: Hazim Abdulrazzaq Hanoon --- Ahmed K. M. Alshara
Journal: Basrah Journal for Engineering Science مجلة البصرة للعلوم الهندسية ISSN: Print: 18146120; Online: 23118385 Year: 2011 Volume: 11 Issue: 1 Pages: 16-30
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

Parallel flow microchannel heat exchanger performance was numerically investigated, for laminar, 3-D, incompressible and steady state flow with slip flow and temperature jump conditions. The continuity, Navier-Stokes equations and the energy equations for the hot and cold fluids were solved by using finite volumes method and SIMPLE algorithm method with FORTRAN code to obtain the velocity and temperature distributions for the two fluids and the separated wall between them. The main investigation parameter that affected on the performance and effectiveness of heat exchanger are: Reynolds number Re, thermal conductivity ratio Kr, Knudsen number Kn, thickness of separating wall, heat capacity ratio Cr and aspect ratio α. Increasing of Reynolds number, Knudsen number, thickness of separating wall, heat capacity ratio and aspect ratio each separately leads to decrease the effectiveness while increasing of thermal conductivity ratio up to 10 leads to increase the effectiveness. Also, it is found that friction number and Nusselt number both decreases with increasing Knudsen number

حۥقق عدديا أدائيت مبادل حراري مايكروي متىازي الجريان لجريان طباقي ثلاثي الأبعاد وفي حالت الاستقرار ولاانضغاطي بشروط الجريان الأنسلاقي ودرجت الحرارة القافسة. حو عٍادىت الاسخ زَاريت و عٍادلاث اىشخ و عٍادلاث اىطاقتباسخخذا طزيقت اىحجى اى حَذدة و طزيقت ) (SIMPLE algorithm وباسخخذا ىغت فىرحزا ) FORTRAN ,)ىيحصىه عيى حىسيع اىسزعت و درجت اىحزارة وىنلا اى اَئعي واىجذار اىفاصو بي هْ .ٌ عىا وٍ اىبحث اىزئيسيت اىخي حؤثزعيى فعاىيت و ادائيت اى بَاده هي: عذد ري ىْىذس) Re ( و سّبت اى ىَصييت اىحزاريت ) Kr ( و عذد اّدسي ) Kn ( وس لَ اىجذاراىفاصو و سّبت اىسعت اىحزاريت ) Cr ( و سّبت اىىاجهه ) α (. ع ذْ سيادة عذد ري ىْىذس و عذد اّدسي و سّبت اىسعتاىحزاريت وس لَ اىجذار اىفاصو مو عيى حذة حقو اىفعاىيت, وع ذْ سيادة سّبت اى ىَصييت اىحزاريت حشداد اىفعاىيت اىى 10 Kr ,. مذىل اى خْائج حبي بأ عذد الأحخناك و عذد سّيج ملاه اَ يقو ع ذْ اٍ يشداد عذد اّدسي .ِ


Article
Finite Element Analysis of Fins with Convection and Radiation Heat Transfer
تحليل انتقال الحرارة من الزعانف بالحمل والإشعاع باستخدام طريقة العناصر المحددة

Author: Mohammed HamzaAbdulsada محمد حمزة عبد السادة
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2015 Volume: 8 Issue: 2 Pages: 242-258
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

One dimensional analysis of heat transfer from fin is simple when only heat transfer by convectionfrom fin surface. However, in some cases heat transfers by combined phenomena (convection andradiation), this makes the governing differential equation of heat transfer non-linear and the analyticalsolution becomes hard to solve. This paper uses an approximate method to solve the problem withhigh-quality results based on finite element technique. The method can be used for different types offins and for different shapes. The results show suitable agreement between semi-exact solution andnumerical solution

التحليل ببعد واحد لانتقال الحرارة للزعنفة بسيط عندما تنتقل الحرارة من الزعنفة بواسطة الحمل فقط ولكن عندما تنتقلالحرارة من الزعنفة بواسطة التأثير المشترك للحمل والإشعاع، المعادلة التفاضلية لانتقال الحرارة سوف تصبح غير خطيةوسوف يكون الحل التحليلي لها صعب.هذه الورقة استعملت طريقة تقريبية لحل هذه المشكلة مع ظهور نتائج جيدة. والتيهي تعتمد أساسا على تقنية العناصر المحددة. أن الطريقة المستخدمة يمكن أن تطبق على أنواع مختلفة وأشكال مختلفة منالزعانف. النتائج تشير الى توقف مناسيب بين الحل التحليلي والحل العددي


Article
Study the Effect of the Flow on the Performance of a shell and Tube Type Heat Exchanger Using Experimental Design Technique

Authors: Zuher Hassan Abdullah --- Saad Sami Farhan --- Thamer K. Salem
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2016 Volume: 23 Issue: 2 Pages: 38-45
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

In the current research an experimental study was done to show the effect of pulse flow on the effectiveness of shell and tube type heat exchanger. the study was in the case of steady and pulse flows with a changing mass flow rate of hot water flowing inside the pipes of the heat exchanger for the range between (0.0273-0.0819 kg / s) at fix mass flow rate of cold water that flows through the shell and on the outer surface of the pipes when (0.0416 kg / s), to obtain pulsing a used was solenoid valve. The research aims to measure the percentage effect of independent factors which were presenting the mass flow rate of hot water, flow type and the surrounding environment conditions of the experimental side upon shell and tube type heat exchanger performance using experimental design technique at the significant level (0.05).The results derived from the experimental tests showed that pulse flow leads to increase internal heat transfer coefficient (hi) comparing with its value in the steady flow and the highest increase was by (9.75%) at a mass flow rate of hot water (0.0416 kg / s) and increases the overall heat transfer coefficient (U), where the highest percentage was by )4.68%) at a mass flow rate of hot water (0.0416kg/s). The results also showed increasing both the number of transmitted units (NTU) and the effectiveness of the shell and tube type heat exchanger ( ) in the case of pulse flow of its value in the steady flow and the highest percentage of increase occurring was (4.75%) and (1.85%), respectively, and at the mass flow rate of hot water (0.0416 kg / s). Percentage effect of mass flow rate of hot water was (97%, 97.42%, 95.5%, 99.48%) and the percentage effect of each flow type and the errors were (2.8%, 2.25%, 2.44%, 0.4%) and (0. 2, 0.33%, 2.06%, 0.12) respectively.


Article
EXPERIMENTAL AND NUMERICAL STUDY OF ENHANCEMENT HEAT TRANSFER COEFFICIENT IN SPIRAL FLUTED TUBE HEAT EXCHANGER WITH NANOFLUID
دراسة عملية و عددية لتحسين أنتقال الحرارة في انبوب لولبي مخدد بوجود المائع النانوي

Authors: Muna S. Kassim --- Fouad A. Salah --- Ahmed O.Samarmad
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2015 Volume: 19 Issue: 6 Pages: 165-183
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Experimental and numerical investigation has been performed in this work to study enhancement of heat transfer coefficient in spiral fluted tube heat exchanger with Nanofluid. The shell side was made from galvanized tube of (65 mm) outer diameter. The tube was made from copper material of (1000 mm) length having (16 mm) equivalent inner diameter and (17 mm) outer diameter, it was inserted inside the shell. Steam was used, as a heating source where constant wall temperature condition (110˚C) was achieved, and TiO2 /water nanofluid with various volume concentrations (0.08%, 0.1%, 0.2%, and 0.3%) by volume at Reynolds numbers (7000 to 15000) has been employed, as working fluid flows through the inner tube. Fiber glass has been utilized to cover the outer surface of the shell for reducing heat losses. The performance of spiral fluted tube heat exchanger with and without nanofluid was investigated experimentally. Experimental results reveal that the use of spiral fluted tube without nanofluid leads to increase (28-33) % in heat transfer coefficient compared with smooth tube, and the maximum increase in heat transfer coefficient occurs when using spiral fluted tube with nanofluid at 0.3% volume concentration was about (25-28) % higher than the pure water in spiral fluted tube. Empirical correlations for water, nanofluid were represented by Nusselt number. Numerical simulation has been carried out on present heat exchanger to analyze both flow field and heat transfer using ANSYS 14, FLUENT package. The comparison between experimental and numerical results showed good agreement.

في هذا العمل تم انجاز دراسة عملية وعددية لتحسين انتقال الحرارة باستخدام انبوب لولبي مخدد بوجود المائع النانوي. القشرة مصنوعةمن الحديد المغلون 65 مليمتر قطر خارجي. الانبوب مصنوع من النحاس بطول 1000 مليمتر ، 16 مليمتر قطر داخلي مكافئ و 17 مليمتر قطرخارجي تم تثبيته داخل القشرة. استخدم البخار كمصدر حراري على السطح الخارجي للانبوب حيث تم الحصول على درجة حرارة ثابتة لسطحالانبوب ) °C110 (، المائع النانوي من نوع اوكسيد التيتانيوم /ماء مقطر بتراكيز حجمية مختلفة ) 0.08 ، 0.1 ، 0.2 ، 0.3 (% و يمر داخلالانبوب عند عدد رينولدز يتراوح بين ) 7000 - 15000 (. تم عزل القشرة من الخارج بعازل حراري لتقليل الحرارة المفقودة.تمت دراسة اداءالمبادل الحراري ذو الانبوب اللولبي المخدد بدون ومع المائع النانوي. بينت النتائج العملية زيادة في معامل انتقال الحرارة بمقدار) 28 - 33 (% عنداستخدام الانبوب اللولبي المخدد بدون المائع النانوي مقارنه بالانبوب الاملس،تم الحصول على اقصى زيادة في معامل انتقال الحرارة عند استخدامالانبوب اللولبي المخدد بوجود المائع النانوي وبتركيز 0.3 % بمقدار ) 25 - 28 (%مقارنه باستخدام الماء في الانبوب اللولبي المخدد.تم ايجادعلاقات تجريبية للماء و المائع النانوي بدلالة رقم نيسلت.تم انجاز محاكاة عددية للمبادل الحراري لتحليل جريان المائع و انتقال الحرارة باستخدامالبرنامج المختص .ANSYS 14, FLUENT package هناك تطابق مقبول عند المقارنة بين النتائج العملية والعددية

Listing 1 - 10 of 65 << page
of 7
>>
Sort by
Narrow your search

Resource type

article (65)


Language

English (65)


Year
From To Submit

2019 (5)

2018 (11)

2017 (8)

2016 (8)

2015 (8)

More...