High Performance of Silica Fume Mortars for Ferrocement Applications
أستخدام المونة عالیة الأداء في تطبیقات الفیروسمنت

Authors: M. A. Mashrei --- Gh. M. Kamil --- H. M. Oleiwi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2013 Volume: 31 Issue: 13 Part (A) Engineering Pages: 2477-2488
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The current study deals with obtaining the high performance mortars to use in theapplications of ferrocement. The main problem that has greatly affected theperformance of mortar is the workability. A low water-cement ratio mostly resulted inincreases in the compressive strength and led to the enhancement of durabilitycharacteristics, but decreases in the workability.Workability becomes an important factors, as the mortar has to easily penetratebetween the layers of the mesh wires. A reasonably workable with high strengthcement mortar can be obtained by using a high cement content coupled with the useof silica fume and superplasticizers. In this investigation a series of compression testswere conducted on 50 mm cube and 150 ×300 mm, cylindrical specimens to obtainthe compressive strength and the stress-strain behavior of mortar with silica fume andsuperplasticizers and flexural tests were conducted on 50 ×5 0 × 200 mm prism toobtain the modulus of rupture. The results of this study indicated that the variation inmortar strength depend on the water-to-binder ratio of the mix and percentages ofcement replacing. The effects of these parameters on the stress-strain curves arepresented. The best replacement percentage of silica is 3% was concluded in thisstudy. From the experimental results a mathematical model has been developed topredict the 28-day compressive strength of silica fume mortar with different water-tocementitiousratios and superplasticizers percentage

Keywords

Ferrocement --- Mortar --- Silica Fume --- Strength.


Article
Finite Element Analysis of Strengthened Reinforced Concrete Beams (English)
تحليل العتبات الخرسانية المسلحة المقواة باستخدام طريقة العناصر المحددة(English)

Author: Sura A. Majeed سرى عبد الرزاق مجيد
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2013 Volume: 21 Issue: 1 Pages: 134-145
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractThis paper presentedthe application of nonlinear finite element models in the analysis of rectangular reinforced concrete beams strengthened with ferrocement in the form of U-jacket by using ANSYSsoftware. The numerical results are compared with thecorresponding experimental results of unstrengthened beams. The comparisons are carried out in terms of load- deflection curves at mid-span, and failure loads. The predicted results of reference beam are found to be in good agreement with the experimental results. Effect of number of layers of wire mesh on the strength of analyzed beams strengthened with ferrocement jackets has been studied. The same beam is also analyzed after strengtheing it with U-jacketsheets of Carbone Fiber reinforced Polymer (CFRB) and the predicted results are compared with that of the corresponding beams strengthened with ferrocement jackets. The strengthened beams have shown a remarkable improvement in their performances in terms of load deflection and ultimate load.The Carbone Fiber Polymer U-jacket greatly improved the beam ultimate failure load by about 37.44%. Keywords:Beams, CFRP, Finite Element,Ferrocement,Strengthening.

الخلاصةيشمل البحث الحالي تطبيق التحليل غير الخطي باستخدام طريقة العناصر المحددة لتحليل العتبات الخرسانية المقواة بطبقة من غطاء الفيروسمنت على شكل حرف U وباستخدام برنامج (ANSYS) . تم مقارنة النتائج العددية مع ما يرادفها من نتائج عملية للعتبات غير المقواة. تمت المقارنة بدلالة منحي القوة-الهطول عند منتصف الفضاء ومقدار حمل الفشل واظهرت النتائج تقارب جيد مع النتائج العملية. تم دراسة تأثير عدد طبقات مشبكات الفيروسمنت على تصرف العتبات المقواةبالفيروسمنت. كذلك تم تحليل نفس العتب والمقوى باستخدام طبقة من بوليمارات الياف الكاربون ومقارنة النتائج مع تلك التي استخدم فيها الفيروسمنت. اظهرت النتائج تحسن واضح في تحمل العتب المقوى وفي زيادة المطيلية وتبين ان استخدام الياف الكاربون في تقوية العتبات افضل من تلك المقواةبالفيروسنت من ناحية التحمل الأقصى للحمل حيث كان مقدار الزيادة بحدود 37.44%.


Article
FlexuralStrength of Reinforced Concrete Slabs Strengthened and Repaired by High StrengthFerrocement at Tension Zone_ENG
مقاومة الانثناء للبلاطات الخرسانية المسلحةالمقواة والمصلحة بغطاء من الفيروسمنت عالي المقاومة في منطقة الشد

Authors: Mohammed N. Mahmood محمد نجم محمود --- Hassan SideqThanoon حسن صديق ذنون
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2013 Volume: 21 Issue: 2 Pages: 78-89
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractThis paper presents a study of the flexural behavior of strengthened and repaired reinforced concrete slabs by ferrocement. The study includes testing 17 simply supported slabs, which include 2 control slabs, 3 strengthened slabs and 12 repaired slabs. In the strengthenedslabs the effect of number of wire mesh layers of ferrocement on the ultimate load, mid span deflection at ultimate load and intensity of cracks were examined. In the repaired part the slabs were stressed to (70 %) of measured ultimate loadof control slab. The effectsof number of wire mesh layers, ferrocement thickness and the connection method between repaired slabsand ferrocementjacket on the ultimate load, mid span deflection at ultimate load and intensity of cracks were examined.Keywords: Concrete, ferrocement, repair, slab, strengthening

يتضمن البحث الحالي دراسة مقاومة الانثناء للبلاطات المقواة والمصلحة باستخدام الفيروسمنت من خلال تقصي ومقارنة نتائج الفحص لسبعة عشر بلاطة, ثلاث منها مقواةبالفيروسمنت، اثنا عشر بلاطة لدراسة فاعلية عملية الإصلاح وبلاطتان تم أخذهما كبلاطات مرجعية. إن المتغيرات التي تمت دراستها في عملية التقوية هي تأثير عدد طبقات المشبكات السلكية، حيث تم استخدام (2, 3 & 4) طبقات من المشبكات السلكية، على الحمل الأقصى والأود المقابل له بالإضافة إلى تأثيرها على كثافة الشقوق، أما في حالة الإصلاح فقد تم تسليط (70 %) من الحمل الأقصى المأخوذ من البلاطات المرجعية على البلاطات المراد إصلاحها ودراسة تأثير كل من عدد طبقات المشبكات السلكية، حيث تم استخدام (2, 3 & 4) طبقات،وسمك الفيروسمنت، تم استخدام فيروسمنت بسمك (2 & 3 cm)، وطريقة ربط الفيروسمنت بالبلاطة،استخدم اسلوب الربط بواسطة البراغي او بواسطة الايبوكسي,على عملية الإصلاح بالفيروسمنت.


Article
Influence of Number of Wire Mesh Layers on the Behavior Strengthened Reinforced Concrete Columns-ENG
تأثير طبقات المشبك السلكي للفيروسمنت على تقوية الأعمدة الخرسانية المسلحة

Loading...
Loading...
Abstract

AbstractThe main objective of the present experimental program is to study the behavior of reinforced concrete short columns subjected to combined axial load and flexure strengthened with ferrocement. To carry out the investigation, seven columns were tested. Out of which, one is the control un-strengthened column tested to failure to find out their load carrying capacity, six columns strengthened with ferrocement. The main objective of the present work is to investigate the effects of ferrocement thickness and number of wire meshes on the load capacity of those columns.Increasing wire mesh layers from 2 to 5 causes an increase in the ultimate load of the strengthened column with ferrocement compared with the control column. Using 20mm ferrocement thickness with a 5-wire mesh layers, the ultimate load increases 36.8% when compared with the control column. Similarly, for 30mm ferrocement thickness with 5 wire mesh layers the increase is 48%. Key Words:Column, Ferrocement, Reinforced Concrete, Strengthening.

الخلاصةالهدف الرئيسي من البرنامج التجريبي الحالي هو دراسة سلوك الأعمدة الخرسانية المسلحة القصيرة المقواة بالفيروسمنت تحت تأثير أحمال محورية وانثنائية. لإجراء هذه الدراسة، تم اختبار سبعة أعمدة. واحد منها عمود غير مقوى اعتبر كعمود مرجعي مع ستة أعمدة مقواة بالفيروسمنت. الهدف الرئيسي من هذا البحث هو دراسة تأثير زيادة سمك الفيروسمنت وزيادة عدد طبقات المشبك السلكي على قابلية تحمل العمود المقوى بالفيروسمنت. إن زيادة عدد طبقات المشبك السلكي من 2 الى 5 أدى إلى زيادة في قابلية تحمل العمود المقوى بالفيروسمنت مقارنة مع العمود المرجعي. أعلى نسبة زيادة في مقاومة العمود كانت عند استخدام خمسة طبقات من المشبك السلكي حيث ازدادت مقاومة العمود عند استخدام خمسة طبقات وسمك 20 ملم للفيروسمنت بنسبة 36.8% بالمقارنة مع العمود المرجعي بينما كانت الزيادة عند استخدام خمسة طبقات وسمك 30 ملم بحدود 48%.الكلمات الدالة :عمود , فيروسمنت , خرسانة مسلحة, تقوية