research centers


Search results: Found 5

Listing 1 - 5 of 5
Sort by

Article
Studying the Effect of Volume Fraction of Glass Fiberson the Thermal Conductivity of the Polymer Composite Materials
دراسة تأثير الكسرالحجمي لألياف الزجاج على الموصلية الحراريةللمواد المتراكبة البوليمرية

Author: Mohammed Sellab Hamza محمد صلاب حمزة
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2008 Volume: 4 Issue: 3 Pages: 85-97
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this study the effect of fiber volume fraction of the glass fiber on the thermal conductivity of the polymer composite material was studied. Different fiber volume fraction of glass fibers were used (3%, 6%, 9%, 12%, and 15%). Specimens were made from polyester which reinforced with glass fibers .The fibers had two arrangements according to the direction of the thermal flow. In the first arrangement the fibers were parallel to the direction of the thermal flow, while the second arrangement was perpendicular; Lee's disk method was used for testing the specimens. The experimental results proved that the values of the thermal conductivity of the specimens was higher when the fibers arranged in parallel direction than that when the fibers arranged in the perpendicular direction. The percentage of increasing of experimental thermal conductivity was 96.91% for parallel arrangement and 13.33% for perpendicular arrangement comparison with its original value before the using of glass fibers.
Also the experimental results indicated that the thermal conductivity increases with the increasing of the fiber volume fraction. Minimum value was (0.172 W/m.C) for perpendicular arrangement at fiber volume fraction 3% and maximum value was (0.327 W/m.C) for parallel arrangement at fiber volume fraction 15%.

تم في هذا البحث دراسة تأثير الكسر الحجمي لالياف الزجاج وبنسب مختلفة (15%, 12%, 9%, 6%, 3% ) على التوصيلة الحرارية للمادة المتراكبة. حيث صنعت العينات من مادة البولي أستر غير المشبع المقواة بالياف الزجاج. العينات صنعت في مجموعتين المجموعة الاولى كانت فيها الياف الزجاج مرتبة بشكل موازي للانسياب الحراري، اما المجموعة الثانية نضمت بترتيب الالياف بشكل عمودي على الانسياب الحراري. استخدمت طريقة قرص لي (Leeś disk ) في فحص العينات. اثبتت النتائج العملية ان الترتيب الموازي للالياف يعطي موصلية حرارية اعلى من الترتيب العمودي وان الموصلية الحرارية للمادة المتراكبة تزداد مع زيادة الكسر الحجمي للالياف. حيث كان مقدار الزيادةفي الموصلية الحرارية بسبب التقوية بالالياف هو 96.91% للترتيب الموازي و 13.33% للترتيب العمودي كذلك اثبت النتائج العملية ان اقل قيمة للموصلية الحرارية كانت (0.172w/m.C) للترتيب العمودي عند الكسر الحجمي (Vf=3%) اما اعلى قيمة كانت (0.327W/m.C) للترتيب الموازي عند كسر حجمي (Vf = 15%).


Article
Study the Effect of Carbon Fiber Volume Fraction and their Orientations on the Thermal Conductivity of the Polymer Composite Materials.
دراسة تأثير الكسر ألحجمي لألياف الكربون واتجاهها على الموصلية الحرارية للمواد المتراكبة البوليمرية

Author: Mohammed Sellab Hamza محمد صلاب حمزة
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2008 Volume: 4 Issue: 1 Pages: 80-89
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The effect of fiber volume fraction of the carbon fiber on the thermal conductivity of the polymer composite material was studied. Different percentages of carbon fibers were used (5%, 10%, 15%, 20%, and 25%). Specimens were made in two groups for unsaturated polyester as a matrix and carbon fibers, first group has parallel arrangement of fibers and the second group has perpendicular arrangement of fibers on the thermal flow, Lee's disk method was used for testing the specimens. This study showed that the values of the of thermal conductivity of the specimens when the fibers arranged in parallel direction was higher than that when the fibers arranged in the perpendicular direction
The results indicated that the thermal conductivity increases with the increasing the fiber volume fraction. Minimum value was (0.64 W/m.C) for parallel arrangement and (0.1715 W/m.C) for perpendicular arrangement at (Vf = 5%) .Maximum value for parallel and perpendicular were (2.65 W/m. C) and (0.215 W/m.C) at (Vf = 25%) respectively.

تم في هذا البحث دراسة تأثير الكسر الحجمي لالياف الكاربون وبنسب مختلفة (25%,20%,15%,10%,5% ) على التوصيلة الحرارية للمادة المتراكبة. حيث صنعت العينات من مادة البولي أستر غير المشبع المقواة بالياف الكاربون . العينات صنعت في مجموعتين المجموعة الاولى كانت فيها الياف الكاربون مرتبة بشكل موازي للانسياب الحراري، اما المجموعة الثانية نظمت بترتيب الالياف بشكل عمودي على الانسياب الحراري . استخدمت طريقة قرص لي (Leeś disk ) في فحص العينات. اثبتت الدراسة ان الترتيب الموازي للالياف يعطي موصلية حرارية اعلى من الترتيب العمودي. وبينت النتائج بان الموصلية الحرارية للمادة المتراكبة تزداد مع زيادة الكسر الحجمي للالياف. وان اقل قيمة للموصلية الحرارية كانت ( 0.64 w/m.C) للترتيب الموازي و (w/m.C 0.1715) للترتيب العمودي عند الكسر الحجمي (Vf=5% ) اما اعلى قيمة كانت(2.65 w/m.C) للترتيب الموازي و (0.215 w/m.C) للترتيب العمودي عند كسر حجمي (Vf = 25%) .


Article
Study of Thermal Characteristics of a Composite Specimen Experimentally and by Using Finite Element Method

Authors: Jawad Kadhim Uleiwi --- Sura Salim
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2008 Volume: 26 Issue: 4 Pages: 429-441
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This research deals with the study of the effect of fibers volumefraction and fibers orientation on the thermal conductivity and wall surfacetemperatures for composite specimen in form of Lee’s disk by usingexperimental work and finite element technique. The results show thatthe thermal conductivity increases with increasing fiber volume fraction ofthe composite specimen, and in the longitudinal direction is larger than inthe lateral fiber direction.The experimental results indicated that the largestvalue of the thermal conductivity for the composite specimen was (0.611W/m.°c) at (Vf = 40 %) in the longitudinal direction, while the lowest valuewas (0.195 W/m.°c) at (Vf = 10 %) in the lateral direction. Also the resultsshow that the maximum difference for the thermal conductivity between theexperimental work and finite element method was ( 7 % ) at ( Vf = 10 % )in the lateral direction while the minimum value was ( 3.5 % ) at ( Vf = 40% ) in the longitudinal direction.

تناول هذا البحث دراسة تأثير كل من الكسر الحجمي للألياف وأتجاه الألياف علىالموصلية الحرارية ودرجات حرارة سطح الجدار لعينة مادة مركبة على شكل قرص لي .بينت النتائج بانه بزيادة الكسر الحجمي تزداد الموصلية الحرارية للمادة المركبةوبالاتجاه الطولي للالياف وتكون اكبر من الموصلية الحرارية بالاتجاه العمودي على الالياف .( 0.611 W/m.°c ) كما بينت النتائج العملية بأن اعلى موصلية حرارية للعينة المركبة كانتوبأتجاه موزاي للألياف بينما أقل قيمة للموصلية الحرارية (Vf = عند كسر حجمي (% 40وبأتجاه عمودي على (Vf = 0.195 ) عند كسر حجمي (% 10 W/m.°c) للعينة المركبة كانتالألياف. وأظهرت النتائج ايضا" بان اعلى فرق للموصلية الحرارية بين النتائج العملية والنتائجالنضرية هو (% 7) عند كسر حجمي (% 10 ) وبالأتجاه العمودي على الألياف. بينما أقلفرق للموصلية الحرارية بين النتائج العملية والنتائج النضرية هو (% 3.5 ) عند كسر حجمي40 ) وبالأتجاه الطولي للألياف.


Article
IMPROVEMENT OF TEMPERTURE RESISTANCE OF Al-Mg/Al2O3P COMPOSITE BY COATING WITH ANTIMONY TRIOXIDE FILM
(Al-Mg/Al2O3P) تحسين مقاومة درجة الحرارة للمواد المتراكبة

Authors: Mushtaq Taleb Albdiry --- Saad Hameed Alshafaie
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2008 Volume: 1 Issue: 2 Pages: 172-179
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

Aluminum matrix composites AMCS with 10 wt % Al2O3 particles with average size (3.86 µm) were fabricated by stir casting method, then the composite produced coated with Antimony Trioxide (Sb2O3) by hot dipping coating process. Thermal conductivity of composite materials with and without coating was estimated by applying Fourier equation to investigate its behavior under different temperature conditions. Results revealed that coating with antimony trioxide decreased the thermal conductivity (k) of composite material. The thermal conductivity of the master composite material was (207 W/mC) at (80 C) and (182 W/mC) of the coated composite material at same temperature.

صنعت المواد المتراكبة المعدنية ذات أساس الألمنيوم AMCS من جزيئات اوكسيد الألمنيوم (Al2O3) بنسبة(10 wt %) ومتوسط حجم حبيبي(3.86 µm) باعتماد طريقة السباكة بالمزج( (Stir casting, بعدها تم طلاء المادة المتراكبة الناتجة باوكسيد الانتيمون الثلاثي باعتماد طريقة التغطيس الحار (Hot dipping), حسبت الموصلية الحرارية (Thermal conductivity, k) باعتماد معادلة فورير, فأظهرت النتائج بان طبقة الطلاء باوكسيد الانتيمون تعمل على تقليل الموصلية الحرارية للمادة المتراكبة حيث كانت قيمة الموصلية الحرارية للمادة المتراكبة الأساس هي ( W/m˚C (207 عند درجة حرارة (80C) بينما قيمتها للمادة المتراكبة المطلية هي ( 182 W/m˚C) عند نفس الدرجة الحرارية.


Article
Determination of Thermal Conductivity of Compact Graphite Iron

Authors: S.F. Alsaffar --- K.I. Khalaf --- A.N. Abo Raghif
Journal: Iraqi Journal of Applied Physics المجلة العراقية للفيزياء التطبيقية ISSN: 18132065 23091673 Year: 2008 Volume: 4 Issue: 4 Pages: 3-6
Publisher: iraqi society for alternative and renewable energy sources and techniques الجمعية العراقية لمصادر وتقنيات الطاقة البديلة والمستجدة

Loading...
Loading...
Abstract

It is presented an experimental study about thermal conductivity in gray iron and compacted graphite iron. Thermal conductivity of the specimen is measured by a comparative method with stationary axial heat flow according to ASTM E 1225. The investigated specimen is put in a stack in tight thermal contact with two reference materials of same diameter. The upper reference specimen is coupled to a heat source, the lower reference to a heat sink. A guard heater and other experimental setup minimize radial heat losses. Reference material is electrolytic iron with certified thermal conductivity. It was tested 2 gray irons, the first alloyed with CuSnCr and the second with CuSnCrMo. Two grades of compacted graphite iron were also tested, CGI 350 and CGI 450. The tests were conducted up to 400°C.

Listing 1 - 5 of 5
Sort by
Narrow your search

Resource type

article (5)


Language

English (3)

Arabic and English (2)


Year
From To Submit

2008 (5)