research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Effect of Ultrasonic Waves on Sedimentation Characteristics and sludge Dewaterability
تأثير الأمواج فوق الصوتية على كل من الخصائص الترسيبية وقابلية الحماة لنزع الماء

Author: Ahmed Yassin Shehab احمد ياسين شهاب
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2011 Volume: 19 Issue: 6 Pages: 30-39
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractThis paper studied the effect of ultrasonic waves on sedimentation characteristic of activated sludge and there causes on filamentous growth, as well as its effects on the sludge ability dewaterability. The power of ultrasonic waves was set at (0.35W/cm2) while the frequency and contacts time was varied to (31،44،55 KHz) (10،20،30،40 min) respectively. An instrument with (0.5 L) in volume was used to applied ultrasonic waves, it was connected by plastic tube with a completely mixed activated sludge reactor. Testes shows that the relationship between contacts time of ultrasonic and sludge volume index (SVI) was a sagged curve with an optimum point, that’s means there was a specific contacts time to achieved an optimum sedimentation characteristics at specific frequency. As well as Testes shows that the relationship between contacts time and specific resistance (r) was a linear in first order, that’s indicates the ability of dewaterability of sludge decreased with the increasing of ultrasonic contacts time. Also results shows that the effect of ultrasonic waves on activated sludge related conversely with its frequency.

الخلاصةتناول البحث اختبار قابلية الأمواج فوق الصوتية في تحسين الخصائص الترسيبية للحماة وتمزيق النمو الخيطي فضلا عن دراسة تأثيرها على قابلية الحماة لنزع الماء، وذلك عند تسليط الأمواج بقدرة ثابتة (0.35W/cm2) وترددات متغيرة (KHz 55،44،31) وزمن تعريض متباين ( min40،30،20،10). اُستخدم جهاز مختبري سعة (0.5 L) لتسليط لأمواج فوق الصوتية على الحماة وذلك بربطه مع مفاعل اختباري يعمل بأسلوب الحماة المنشطة ذات المزج التام. أثبتت الاختبارات أن معامل الدليل ألحجمي للحماة (SVI) يرتبط مع زمن التعريض بعلاقة على شكل منحني بنهاية صغرى، حيث تم الحصول على أفضل خصائص ترسيبية للحماة عند زمن تعريض محدد وعند ثبوت التردد. كذلك اثبت اختبار المقاومة النوعية للحماة للاحتفاظ بالماء (r) أن قابلية الحماة لنزع الماء (dewatering) تنخفض كلما ازداد زمن التعريض من خلال ارتباط العاملين بعلاقة خطية من الدرجة الأولى. كما أوضحت نتائج الاختبارات أن شدة تأثير الأمواج على الحماة المنشطة يتناسب عكسياً مع التردد المسلط.


Article
Aeration Tank Behavior in the Activated Sludge Wastewater Treatment Plant Startup Conditions Case study; (Wastewater Treatment plant of General Mosul hospital- IRAQ)
تصرف الخزان المهوى للحمأة المنشطة في معالجة المياه الثقيلة وخلال ظرف تشغيل ابتدائي

Author: Riyadh Mahmood Saleh Al-Obaidi رياض محمد صالح العبيدي
Journal: Muthanna Journal of Engineering and Technology(MJET) مجلة المثنى للهندسة والتكنولوجيا ISSN: 25720317 25720325 Year: 2011 Volume: 1 Issue: 1 Pages: 1-13
Publisher: Al-Muthanna University جامعة المثنى

Loading...
Loading...
Abstract

The biological unit in the waste water treatment plants can be considered the most sensitive treatment units. It begins work with dynamic conditions for several weeks until reach the steady state conditions. Therefore, this study was done to observe aeration tank behavior (activated sludge unit) in the wastewater treatment plant of general hospital complex of Mosul city. Sampling made daily for more than 30 days. The biological treatment monitoring parameter was tested. The study shown that there is need to about 45-60 days to complete the start up work to be the operation stable and successful (if it worked without seeding). There was simple growth of microorganisms with modest treatment of organic matter, and then it rose after 3 first weeks of operation. There was contrary relationship between organic content and suspended solids in the aeration tank; an equation of this relation has been presented. The pH has risen in the first days in the effluent wastewater, then return to be less than influent pH with a relative relation with the activity of the microorganisms and surface aeration in the tank. The EC was simply reduced in the Effluent along with the study.

تعد وحدة المعالجة البيولوجية الوحدة الاكثر حساسية بين وحدات محطة معالجة مياه الفضلات . تبدأ الوحدة عملها بظروف ديناميكية (غير مستقرة) لمدة أسابيع لحين وصولها الى حالة الثبات بالعمل. لذلك اجريت هذه الدراسة لمتابعة سلوك حوض التهوية (بوحدة الحمأة المنشطة) في محطة معالجة مياه الصرف الصحي لمجمع المستشفى العام في مدينة الموصل. وقد تم اخذ نماذج يومية من المحطة اثناء بدء تشغيلها لمدة تزيد على 30يوما . وتم قياس مؤشرات مراقبة عمل الوحدة البايولوجية. أظهرت الدراسة بأن هناك حاجة لفترة 45-60 يوما لاكتمال ظروف الابتداء والوصول الى العمل المستقر للوحدة (حين عدم اضافة بذور الحمأة المنشطة). وقد كان هناك نمو بسيط للاحياء المجهرية مع معالجة معتدلة للمحتوى العضوي في المياه الداخلة للمحطة، وتصاعد النمو بعد 3 اسابيع من التشغيل . وكان هناك علاقة عكسية بين محتوى المواد العضوية في حوض التهوية وبين المواد العالقة (الكتلة الحية). كما حصل ارتفاع لمؤشر الدالة الحامضية pH في الايام الاولى من بدء التشغيل ثم تراجع ليكون pH في المياه المعالجة اقل منه في الداخلة بسبب نشاط الاحياء المجهرية والتهوية السطحية في الحوض. بينما تناقص مؤشر التوصيلية الكهربائية بنسبة قليلة في المياه المعالجة على طول فترة الدراسة ، وتزايد استهلاك الاوكسجين عند اكتمال عملية البدء بالتشغيل.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic (1)

English (1)


Year
From To Submit

2011 (2)