research centers


Search results: Found 3

Listing 1 - 3 of 3
Sort by

Article
Noise Removal of ECG Signal Using Recursive LeastSquare Algorithms
إزالة ضوضاءِ التي تَستعملُ أقلّ تكراريةً الخوارزمياتِ المربّعةِ

Author: Noor K. Muhsin نور كمال محسن
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2011 Volume: 7 Issue: 1 Pages: 13-21
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This paper shows an approach for Electromyography (ECG) signal processing based on linear and nonlinear adaptive filtering using Recursive Least Square (RLS) algorithm to remove two kinds of noise that affected the ECG signal. These are the High Frequency Noise (HFN) and Low Frequency Noise (LFN). Simulation is performed in Matlab. The ECG, HFN and LFN signals used in this study were downloaded from ftp://ftp.ieee.org/uploads/press/rangayyan/, and then the filtering process was obtained by using adaptive finite impulse response (FIR) that illustrated better results than infinite impulse response (IIR) filters did.

هذا البحث يبحث نظرةً لمعالجةِ إشارات تخطيط القلب مستندة على التَرْشيح التكيفيِ اللاخطّيِ والخطيِّ الذي يَستعملُ خوارزمية أقلّ تكراريةً المربعِ لإزالة إثنان مِنْ أنواعِ الضوضاءِ الذي المؤثره على إشارةِ تخطيط القلب و المتمثله بضوضاءَ التذبذب العالي و ضوضاءَ التذبذب الواطئ. المحاكاة مُؤَدّية بأستخدام ال ضوضاءَ التذبذب العالي و ضوضاءَ التذبذب الواطئ َالمستعملهْ في هذه الدراسةِ حُمّلتْ مِنْ الإنترنتِ ، وبعد ذلك عملية التَرْشيح بإستعمال استجابة الحافز المحدود الذي صوّرَ نَتائِجَ افضل مِنْ مرشحاتِ استجابة الحافز اللانهائي.


Article
Removing 0.5 Hz Baseline Wander From ECG Signal Using Multistage Adaptive Filter

Author: H. H. Abbas
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2011 Volume: 29 Issue: 11 Pages: 2312-2328
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This paper deals with the implementation of software system to remove 0.5 Hz baseline wander noise from the ECG signal using multistage adaptive filter. At start, a single stage adaptive filter has been implemented and the performance of the implemented system has been checked for changing the values of noise levels, the convergence factor of the adaptive algorithm, and the length of the adaptive filter.From testing results it is clear that the performance of the implemented system changes by the above factors values.Then an adaptive filter with the best values for the above factors has been used as a prototype to build multistage filter.The resulted multistage adaptive filter has been tested to prove its capability to remove 0.5 Hz baseline wander noise as compared with single stage adaptive filter. From testing results, it is clear that multistage filter gives better results than single stage filter.


Article
Three Dimensional Echocardiographic Determinations of Global and Segmental Functions in Patients with Left Ventricular Aneurysm
إيجاد الفعالية الكلية والمقطعية للمرضى المصابين بام الدم للبطين الايسر باستخدام فحص صدى القلب ثلاثي الابعاد

Author: Noori Y. Kattami د. نوري يونس كطامي
Journal: IRAQI JOURNALOF COMMUNITY MEDICINE المجلة العراقية لطب المجتمع ISSN: 16845382 Year: 2011 Volume: 24 Issue: 2 Pages: 153-159
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Objectives: To determine the global and regional functions of the left ventricle (LV) in patients with LV aneurysm (LVA) utilizing reconstructed three dimensional echocardiography (3DE), that can help for making the decision for aneurysmectomy.Materials &Methods: Computer algorithms and suitable visual basic program were used to reconstruct 3DE LV images of a patient with LVA who underwent two dimensional echocardiography (2DE). Quantitative LV volumes and wall motions analysis were performed and compared to a computerized LV model. Results: The results obtained from the 2DE analysis of the patient studied were used to reconstruct 3DE LV images at end systole (ES) and end diastole (ED) that showed apical dyskinesia. LV volumes and their indices, % ejection fraction (%EF), and LV wall motions of the patient studied and 3DE LV model were calculated and plotted superimposed. Discussion: 2DE approach is based on geometric assumptions for calculating LV volumes and wall motions, while 3DE technique requires no geometric assumptions that limit accuracy in patients with LVA. So the present method can potentially overcome these limitations. Conclusion: LV volumes and wall motion in the present method were calculated accurately, and can be used in diagnosing and following the therapeutic managements in patients with LV aneurysm,Keywords: Three dimensional, ECG, Global, segmental function, Ventricular aneurysm

الهدف من الدراسة:لايجاد فعالية البطين الايسر الكلية والمقطعية للمرضى المصابين بام الدم باستخدام البناء ثلاثي الابعاد الخاص بفحص صدى القلب والذي يساعد في اتخاذ القرار لاجراء عملية رفع ام الدم من البطين الايسر . الطريقة:استخدم برنامج البيسك المرئي مع خوارزميات مناسبة على الحاسوب لبناء صورة ثلاثية الابعاد للبطين الايسر لمريض مصاب بام الدم والذي اجري له فحص صدى القلب ثنائي الابعاد , ثم تم اجراء التحليل الكمي لحركة جدار البطين الايسر وحساب الحجم ومقارنة ذلك مع موديل حاسوبي للبطين الايسر. النتائج:استخدمت نتائج تحليل فحص صدى القلب ثنائي الابعاد للمريض المصاب بام الدم في بناء صور ثلاثية الابعاد للبطين الايسر في حالة الانقباض والانبساط واظهرت النتائج بوجود ام الدم في المنطقة القمية للبطين الايسر بعد حساب الحجوم وفعالية الضخ وحركة الجدار للبطين الايسر للمريض ولموديل البطين الايسر الحاسوبي .المناقشة: يعتمد حساب حجم وحركة جدار البطين الايسر باستخدام فحص صدى القلب ثنائي الابعاد على فرضيات هندسية بينما لايحتاج فحص صدى القلب ثلاثي الابعاد الى هذه الفرضيات التي تحد من دقة النتائج للمرضى المصابين بام الدم لذا فان الطريقة الحالية لها القدرة على احتواء كل هذه التحديدات الاستنتاجات: تم حساب حجم وحركة جدار البطين الايسر بدقة باستخدام الطريقة الحالية والتي يمكن استعمالها في التشخيص ومتابعة الاساليب العلاجية للمرضى المصابين بام الدم

Listing 1 - 3 of 3
Sort by
Narrow your search

Resource type

article (3)


Language

English (2)

Arabic and English (1)


Year
From To Submit

2011 (3)