research centers


Search results: Found 4

Listing 1 - 4 of 4
Sort by

Article
COMPARISON OF DIFFERENT UNCONVENTIONAL THERMAL ENERGIES FOR STEEL CUTTING PROCESS
مقارنة مصادر طاقة حراریة غیر تقلیدیة في عملیة قطع الفولاذ

Author: Jasim Hassan Rasheed جاسم حسن رشید
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2013 Volume: 6 Issue: 1 Pages: 17-26
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

ABSTRACT:- different unconventional heat sources for material processing werediscussed . The heat sources such as plasma arc, electron beam and Co2 laser were employedpreviously by other researchers, while " Co2laser– gas mixture" system was studied duringthe present research .Comparison between the results of present work with the others mentioned above wasmade . The parameter which was adopted for comparison is the "energy consumed per unitlength" for particular thickness .The parameter is based on the equation which was suggestedby the author of this research .Linear relationship between energy per unit length with thickness forCo2 laser aloneand "Co2laser – gasmixture " was found, while for other heat sources it was found out of theproportionality. This comparison showed the superiority of the "Co2laser –gas mixture"system over the other heat sources during cutting mild steel.

الخلاصةتمت مناقشة المصادر الحراریة غیر التقلیدیة المستخدمة في معالجة المواد حراریا وهذه المصادر الحراریة هيالبلازما ، وشعاع الالكترون ولیزر ثاني اوكسید الكاربون المستخدمة في بحوث سابقة بینما تم استخدام منظومة لیزر ثانياوكسید الكاربون مع دفق خلیط من الهواء وغاز الاوكسجین خلال بحثنا الحالي واجرینا مقارنة بین نتائج بحثنا الحاليوالسابقة وان العامل الذي تمت حسابات المقارنة على ضوئه" الطاقة المصروفة لوحدة الطول " ولسمك معین .ان هذا العامل قد اسس على معادلة مقترحة من قبل صاحب هذا البحث ، لقد وجدنا علاقة خطیة بین الطاقةالمصروفة لوحدة الطول ولسمك معین بالنسبة للمصدرین لیزر ثاني اوكسید الكاربون ومنظومة "لیزر ثاني اوكسید الكاربون– وخلیط الغاز" . بینما كانت العلاقة غیر خطیة بالنسبة للمصادر الحراریة الاخرى، لقد اظهر هذا البحث افضلیةالمصدر الحراري "لیزر ثاني اوكسید الكاربون – وخلیط الغاز" على المصادر الحراریة الاخرى بوضوح .


Article
A Comparative Study Between Co2 Laser And Mechanical Rotary System Abrasion Of Hyperpigmentation Of The Gingiva
دراسة مقارنة بين استخدام ليزرثاني اوكسيد الكاربون والقشط المكانيكي بواسطة الة الحفر السريعة لرفع تصبغ اللثة

Author: •Mahdi A.S.AL-Faraaon
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2013 Volume: 11 Issue: 3 Pages: 230-237
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

Gingival pigmentation is one of most difficult cosmetic problems to treat through conventional ways. Although physiological and ethnic melanin pigmentation is not a medical problem. The black pigmentation was removed with Er-YAG laser and Nd-YAG laser. CO2 laser is revealed an easy, safe, short operation time, and not discomfort to the patient post operatively. This way of removing unwanted pigmentation relieved a good result clinically. Eighty patients were submitted in comparative study between CO2and mechanical bur abrasion. CO2 laser is revealed an easy, safe, short operation time, and not discomfort to the patient post operatively. The results were evaluated in histological lab in al-sadar teaching hospital.

تعتبر تصبغات اللثة واحدة من اصعب مشاكل التجميل معالجة بالطرق التقليدية . ان صبغة الميلانين فسلجية وعرقية وهي ليست مشكلة طبية .حيث ان التصبغات الغامقة ممكن ازالتها بواسطة ليزر ER:YAG وليزر ND:YAG , إلا أن علاجها بليزر CO2 أكثر سهولة وأسرع وآمن جدا والعملية تستغرق وقت أقصر , ولا يتعرض المريض للإزعاج ويكون مرتاح بعد العملية .أن هذه الطريقة لإزالة التصبغات الغير مرغوب فيها نتائجها السريرية مضمونة وجيدة جدا .تم معالجة ثمانون مريضا اربعون منهم بالطريقة الميكانيكية واربعون الباقين بهذه الطريقة الجديدة للعلاج في العراق.كانت النتائج مشجعة باتجاة العلاج بالليزر وذلك لسهولة العملية وسرعة الشفاء وقلت المعانات وتم تقييم النتائج سريريا واخذت بعض العينات لمختبر الانسجة في مستشفى الصدر التعليمي لتقييم الشفاء النسيجي


Article
The Role of Nozzle and its Stand off distance in metal –cutting with "CO2 laser –gas jet"
دور النوزل والمسافة الفاصلة في قطع المعادن بواسطة ليزر ثاني اوكسيد الكاربون ودفق غازي

Author: Jasim Hassan Rasheed جاسم حسن رشيد
Journal: Diyala Journal For Pure Science مجلة ديالى للعلوم الصرفة ISSN: 83732222 25189255 Year: 2013 Volume: 9 Issue: 3 Pages: 14-27
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

Abstract:The aim of the present research is to study the role of nozzle and the effect of the stand –off distance which are the most important parameters for cutting mild steel by "CO2 laser – gas jet . Relationship between the laser power and stand-off distance of nozzle at different cutting speed and thicknesses were achieved. It was found that the power increases with cutting speed for particular stand-off distance. In addition , the laser power proportional with stand-off distance for low cutting speed but out the proportionality at high cutting speed .However, the results of this study are necessary in order to move another step towards understanding and to clarify their benefits for cutting process by laser

الهدف من البحث الحالي هو دراسة دور النوزل وتأثير المسافة الفاصلة عن سطح العينة وهما عاملين مهمين جدا في عملية القطع بمنظومة ليزر ثاني اوكسيد الكاربون مع وجود دفق غازي .لقد تم ايجاد علاقة بين قدرة الليزر والمسافة الفاصلة للنوزل عند سرع قطع مختلفة لعينات من الفولاذ ذات اسماك مختلفة حيث وجد بان القدرة تزداد مع سرعة القطع لمسافة فاصلة محددة بالاضافة فان هذه القدرة تتناسب طرديا مع الفاصلة عند السرع الواطئة وتكون خارج التناسب الطردي عند السرع العالية.ان نتائج هذه الدراسة ضرورية للتقدم خطوة اخرى نحو فهم وايضاح فوائد عملية القطع بواسطة منظومة الليزر


Article
The dynamical work of continuous CO2 laser and studying some of plasma parameters produced by laser
ديناميكية تشغيل ليزر ثاني اوكسيد الكاربون المستمر ودراسة بعض معلمات البلازما المنتجة باليزر

Author: Awatif Sabir Jassim عواطف صابر جاسم
Journal: Diyala Journal For Pure Science مجلة ديالى للعلوم الصرفة ISSN: 83732222 25189255 Year: 2013 Volume: 9 Issue: 1 Pages: 24-41
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

In this paper we introduce a modified continuous CO2 laser ( CW CO2 laser ) hence some changes in the principle constitutions were done, such that , the continuous power supply with output voltage of 12 KV and 100 mA . For the purpose of measuring the effect of temperature of laser medium on basic parameter, the system was connected to digital thermometer. The measurement of some basic parameters and its effect on the output power of laser and the selection of optimum condition for operating the system in case of operating by using three gas cylinders (CO2, N2, He) separately and the other by using gas mixture of ( He: 82%, N2: 13.5%, Co2: 4.5% ) , three factors were subjected to change , first, the change of pressure of gas mixture inside the electric discharge tube, second, the effect of changing the electric discharge current, third, the effect of changing the ratio of He gas in the gas mixture were achieved the experimental results shows that the best pressure for gas mixture to produce the laser is ( 30 mbar ) while it was ( 25 mbar ) in using each gas separately by ratios ( 10: 15: 75 )% for ( CO2, N2, He ) respectively with different discharge currents . 12 mA was found to be the best discharge current and 75% was the best ratio for He in gas mixture . The characteristics of plasma-laser CO2 was studies, the theoretical value of the output power laser were determined and compared with measured value

تم في هذه الدراسة تأهيل منظومة ليزر ثاني أوكسيد الكاربون المستمر ( CW Co2 Laser ) حيث تم تغير بعض المكونات الأساسية للمنظومة ، ومن هذه المكونات مجهز القدرة الكهربائي المستمر بفولتية خرج مقدارها (12KV ) وتيار (100 mA) . لغرض قياس درجة الحرارة تم ربط المنظومة بمقياس رقمي (Digital Thermometer) حيث تم من خلاله دراسة تأثير درجة حرارة الوسط الليزري على المعلمات الأساسية. تم خلال هذه الدراسة قياس بعض المعلمات الأساسية وتأثيرها على قدرة الخرج الليزري واختيار الشروط المثلى للتشغيل المنظومة في حالتي تشغيل المنظومة باستخدام ثلاث أسطوانات للغازات (CO2 -N2 -He) على انفراد ، والحالة الثانية استخدام خلطة غازية مجهزة من قبل شركة (PHWY) الألمانية وبنسب (He:82% -N2:13.5% -CO2:4.5%) . وتم دراسة بعض المعلمات وتأثيرها على قدرة خرج ليزر CO2 من خلال دراسة تغيير ضغط الخليط الغازي داخل انبوبة التفريغ الكهربائي ، وكذلك تأثير تغيير تيار التفريغ الكهربائي إضافة إلى تأثير تغيير نسبة غاز He في خليط الغازات على هذه القدرة . أظهرت النتائج العملية ان أفضل ضغط لخليط الغازات الجاهزة لتوليد الليزر هو (30 mbar) بينما كان أفضل ضغط عند استخدام الغازات كلٌ على انفراد هو ( 25 mbar ) بنسب (% (10:15:75)للغازات ( CO2 , N2 , He) على التوالي عند تيار التفريغ مختلفة ، اما أفضل تيار تفريغ فكان ( 12 mA ) ، اما أفضل نسبة لغاز الهليوم في خلطة الغازات كانت ( 75% ) .وكذلك تم دراسة خصائص بلازما ليزر CO2 والتوصل الى القيمة النظرية لقدرة الخرج الليزري ومقارنة هذه القيمة مع القيمة العملية المحسوبة.

Listing 1 - 4 of 4
Sort by
Narrow your search

Resource type

article (4)


Language

English (3)

Arabic and English (1)


Year
From To Submit

2013 (4)