Radon Concentrations Assessment and Effective Dose Estimation in The Buildings of University of Technology/ Baghdad
تقييم تراكيز الرادون والجرعة الفعالة في مباني الجامعة التكنولوجية- بغداد

Authors: Sahar A. Amin --- Saadi M. D. Al-Nuzal --- Muwafaq H. M. Lami and --- Shemaa K. Kataa
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 13 Part (A) Engineering Pages: 3216-3227
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The objective of the present work was to assess the distribution of radon in the University of Technology buildings, Baghdad - Iraq and to identify the effective dose of radon exposure to the staff using passive dosimeter (SSNTD) CR-39. One hundred CR-39 dosimeters were distributed over different buildings in the University campus according to the number of floors area. The exposure time started from December 2012, and the dosimeters were left inside buildings for 40 days. Only 93 dosimeters were collected, while the remaining 7 were considered lost. The average concentrations were calculated in units of Bqm-3, for each sample in each building, and then are repeated after grouping in each floor of the same building. The average radon concentrations per building and at the university as a whole were also calculated. Radon concentrations were found to vary from 80.1 to 416.7 Bqm-3. The highest radon concentration with a mean value of 416.7 Bqm-3 was found atuniversity press section building, while the lowest radon concentration was found at the welding division 2 building with a mean value of 80.1 Bqm-3. The average value of radon concentration at the university was found to have the value of 181.9 Bqm-3 which is less than the recommended value of 200 Bqm-3 UNSCEAR [18].Dose rate (in µSv/h), annual dose rate (in mSv/y & WLM/y), cumulative dose (in mSv& WLM) and cancer risk were also calculated. It was found that the university staffs are exposed annually to 2.083 mSv which equal to 0.231 Working Level Month (WLM) from radon gas and its short-lived daughters. Hence, a person takes on the average an annual effective dose equivalent to 2.56and 1.84mSv according to average value considered by UNSCEAR [18] and ICRP [19], respectively. This implies an expected value for lung cancer probability of 0.0046.

هدف البحث الى تقييم تركيز الرادون في مباني الجامعة التكنلوجية, بغداد – العراق وكذلك حساب الجرعة الفعالة التي يتعرض لها العاملون في الجامعة باستخدام مجراع كاشف الاثر النووي CR-39. تم توزيع 100 مجراع في مباني الجامعة وتُركتلمدة 90 يوم ابتداءاً من كانون الاول 2012. بينت النتائج ان تركيز غاز الرادون يتراوح بين اوطأ قيمة له80.13 بيكريل/م3 في مبنى شعبة اللحام الى اعلى قيمة له416.67 بيكريل/م3 في مبنى مطبعة الجامعة. كما وجد ان متوسطمستوى الرادون في الجامعة 181.86 بيكريل/م3 وهذه القيمة اقل من القيمة المسموح بها عالمياَ.كما تم في هذه الدراسة حساب معدل الجرعة ومعدل الجرعة السنوية والجرعة المتراكمة وكذلك نسبة خطر الاصابة بسرطان الرئة. وُجد ان العالمين في الجامعة يتعرضون سنوياً الى 2.083mSv من غاز الرادون ووليداتها وهي اقل من المعدلات المسموحة والمقترحة منUNSCEAR (1982) و . ICRP (1993)


Article
Calculation of Of Skin Absorbed Dose For The Staff And Students From External Gamma Ray Source In Nuclear Physics Lab
حساب جرعة الجلد الممتصة للكادر التعليمي و الطلبة من مصدرخارجي باعث لاشعة كاما في مختبر الفيزياء النووية

Author: Lubna A. Mehdi لبنى عبد الرسول مهدي
Journal: Journal of Kufa - physics مجلة الكوفة للفيزياء ISSN: 20775830 Year: 2014 Volume: 6 Issue: 1 English and Arabic Pages: 129-137
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

The aim of this project is to determine the amount of the dose absorbed by skin of the staff and students while they are working in nuclear physics lab. and to determine whether they are in safe side or not .The parameters that which are studied in this project are the exposure time ,the distance from radioactive source and the activity of radioactive gamma ray source ,where two radioactive sources are involved in this study are CO60 (1.25 Mev) and Cs137 (0.266 Mev) .This project show that all of the studied parameters have significant effect on the skin absorbed dose whether it's in the positive or negative side.

الهدف من هذا البحث هو لتحديد كمية الجرعة الممتصة من قبل جلد الكادر التعليمي والطلبة إثناء فترة تواجدهم في مختبر الفيزياء النووية ولتحديد ما إذا كانوا (الكادر+ألطلبه) في الجانب الأمين أو لا (من ناحية خطر الإشعاع).العوامل المدروسة في هذا البحث هي زمن التعرض ,المسافة عن المصدر المشع و النشاط الإشعاعي لمصدر باعث لأشعة كاما .في هذا البحث تم اخذ عنصرين مشعين هما (,1.25 Mev Co60) و(Cs137, 0.266 Mev) ).وضح البحث بان كل العوامل المدروسة لها تأثير واضح على جرعة الجلد سواء كانت في الجانب الايجابي أو السلبي.


Article
Measurement of Radon Concentrations and Annual Dose Rate in some Regions of Baghdad City using LR-115 Nuclear Track Detector

Author: Lutfi Majeed Mohammed Salih
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2014 Volume: 17 Issue: 3 Pages: 94-98
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

In this work, LR-115 solid state nuclear track detector used to measure the indoor and outdoor radon concentrations, the annual absorbed dose rate and annual effective dose rate to the lung, were measured in nine houses at different places of Baghdad city, the observed values of indoor and outdoor radon concentrations was in range of 14.7-46.17 Bq/m3 and 9.69–35.69 Bq/m3 respectively. The resulting concentration of Short-lived radon daughters expressed in term of an equilibrium-equivalent radon concentration (EEC), the minimum and maximum indoor results of (EEC) was 5.88-18.46 Bq/m3 and the outdoor results was 6.78-24.98 Bq/m3. The Potential Alpha Energy (PAE) concentration expressed in Working Level (WL) units was in the range of 1.58-4.99 mWL in indoor and 1.8-6.75 mWL in outdoor regions. The annual effective dose calculated according to the radiation weighting (WR) factor for alpha particles and the tissue weighting (WT) factor and the annual absorbed dose rate, the present results confirmed that the radon gas concentrations in all the nine places of Baghdad city are lower than the International Commission Radiation Protection (ICRP) agency, recommended value (200Bq/m3).

في هـذه الدراسـة تم استخدام كاشـف الاثر النووي LR-115 لقياس تراكيز غاز الرادون في داخل الابنية وخارجها في تسعة منازل في مناطق مختلفة من مدينة بغداد. وتم حساب معدل الجرع السنوية الممتصة ومعدل الجرع الفعالة في الرئة، وقد أظهرت النتائج التي تم الحصول عليها أن قيم تراكيز الرادون في داخل وخارج الابنية تتراوح بين (14.7 - 46.17) Bq/m3 و Bq/m3 (9.69 – 35.69) على التوالي. ان تركيز النواتج الوليدة لغاز الرادون والتي يعبر عنها بمكافئ التوازن لتركيز غاز الرادون (EEC)، وكان الحد الاعلى والادنى لنتائج (EEC) داخل الابنية (5.88-18.46) Bq/m3 وخارجها كانت (6.78-24.98) Bq/m3. وتركيز الطاقة الكامنة لجسيمات الفا (PAE) تم حسابه بوحدات (WL) وكانت نتائجه داخل الابنية (1.58-4.99) (mWL) وخارجها (1.8-6.75) (mWL). وتم حساب الجرعة السنوية الفعالة نسبة الى عامل الترجيح للاشعاع لجسيمات الفا (WR) وعامل الترجيح (WT) ومعدل الجرع السنوية الممتصة، النتائج الحالية أكدت أن تراكيز غاز الرادون في تسعة مناطق من مدينة بغداد هي اقل من الحد المسموح بهمن قبل لجنة الوكالـة الدولية للوقايـة مـن الاشعـاع(Bq/m3 200).


Article
Accuracy and Safety of the Free Hand Technique for Thoracic Pedicle Screw Placement in Spinal Deformity

Authors: Mohanned A. Al-Falahi --- Mohammad Saeed --- Adnan A. Karim
Journal: Iraqi Academic Scientific Journal المجلة العراقية للاختصاصات الطبية ISSN: 16088360 Year: 2014 Volume: 13 Issue: 2 Pages: 279-290
Publisher: The Iraqi Borad for Medical Specialization المجلس العراقي للاختصاصات الطبية

Loading...
Loading...
Abstract

ABSTRACT:BACKGROUND: Pedicle screw construct has become widely accepted method for correction of spinal deformities. Better correction, higher rates of fusion as well as low complication rates have been reported. Free hand technique for placement of pedicle screw has been shown to be associated with low complication rate when performed by experienced surgeon. Low dose CT scan was used for postoperative assessment of screw placement and shown to be safe and effective method.OBJECTIVE: To determine the accuracy and safety of malpositioned screws in the thoracic spinal deformities using the free hand technique and to determine the effectiveness of the low dose CT scan regarding this issueMETHODS: 502 pedicle screws were used in 21 patients with adult idiopathic and congenital scoliosis using the free hand technique, screws positions were estimated one week postoperatively using low dose CT scan.RESULTS: Of the 502 screws inserted 262 (52.19%) were well placed inside the pedicle while 110 (21.91%) were medially misplaced and 108 screws (21.51%) were misplaced laterally, 16(3.19%) anterior perforation, 5 (1%) perforated the underlying neural foramen and 1(0.2%) perforated the upper end plate; without any significant neurological or visceral complication.CONCLUSION: Placement of the thoracic pedicle screws in the surgical correction of the deformed spine using the free hand technique is a safe, cost effective and non-time consuming and that the low dose CT scan used postoperatively is effective and safe method in detecting malpositioned screws.


Article
Measuring the Rates of Radioactive Contamination and Radiation Doses for Rockwool plant
قياس معدلات التلوث الاشعاعي والجرعات الاشعاعية لمعمل الصوف الصخري

Author: Ahmed Abdul Hassan Hussein أحمد عبد الحسن حسين
Journal: JOURNAL OF MADENAT ALELEM COLLEGE مجلة كلية مدينة العلم الجامعة ISSN: 2073,2295 Year: 2014 Volume: 6 Issue: 2 Pages: 49-60
Publisher: City College of Science University كلية مدينة العلم الجامعة

Loading...
Loading...
Abstract

This research aims to assess the radioactivity for the rock wool plant in the province of Baghdad – Al Taji city through conducting radiological survey for the plant which of six part ( crushers , furnaces , machines spinning , materials store and waste site ) in addition assessment of radiation doses to the worker who are near smelting furnaces by using portable detectors to know the level of exposure and the contamination resulting from smelting basalt stone operations which the essential material for making the rock wool, its contain the natural radioactivity series such as U-238 and Th-232 . The results of radiological survey were conducted showed the presence of a significant increase in the rates of radioactive contamination and the dose rates in the area of smelting furnaces ranged between (11.2- 7.81) cps using the FH-40 compared with the rate of natural background 0.75 cps and the rates of radiation doses ranged between (0.65- 0.47) µSv/h using the device RadEye compared with natural background 0.04 µSv/h ,while the reading in another site within normal levels . it also collected soil samples from the smelting furnaces and from basalt stone accumulation site accordance to IAEA standard which were measured by using gamma spectrometry ( which consist of high –purity germanium detector with efficiency of 30% and resolution 2 keV for energy 1.33 MeV of 60Co ) . The results of laboratory tests for the soil elected showed absence of a significant increase in the values of the concentration for the radionuclide which back to the series of U-238 and Th-23 and showed a natural concentrations for isotope of Radium -226 especially in the samples that have been taken from the smelting furnaces ( B1,B2) ranged between (62.23 – 24.1 ) Bq / kg, respectively, that Ra-226 isotope (1600 year half life ) emitting Alpha and Gamma rays and decaying to the Radon gas.Where high concentrations of Radon gas is one of the main reasons causing lung cancer, so it is necessary to use protective equipment needed by workers in these factories.

يهدف هذا البحث الى تقييم النشاط الاشعاعي لمعمل الصوف الصخري الواقع في محافظة بغداد / التاجي من خلال اجراء مسح اشعاعي للمعمل والمتكون من ستةاجزاء (الكسارات , الافران , ماكنات الغزل , المخازن, موقع النفايات وموقع تجميع حجر البازلت ) بالاضافة الى تقييم الجرعات الاشعاعية للعاملين باستخدام اجهزة الكشف الاشعاعي المحمولة لغرض معرفة الزيادة الحاصلة في مستويات التعرض والتلوث الاشعاعي الناتجة من عمليات صهر حجر البازلت الذي يعتبر المادة الاساس في صناعة الصوف الصخري وذلك لاحتوائه على السلاسل الاشعاعية الطبيعية مثل سلسلة اليوراينويم-238 والثوريوم-232. وقد اضهرت نتائج المسوحات الاشعاعية التي اجريت وجود زيادة ملحوضة في معدلات التلوث الاشعاعي في منطقة افران الصهر تراوحت بين cps)11.2– 7.81) باستخدام جهاز FH-40مقارنةً مع معدل الخلفيىة الاشعاعية الطبيعيةcps 0.75 اما معدلات الجرع الاشعاعية تراوحت بين հµSv( 0.65-0.47 ) باستخدام جهاز RadEye مقارنةً مع الخلفية الطبيعية հµSv 0.04 اما بقية المواقع فكانت القراءات ضمن مستوياتها الطبيعية . كما واخذت نماذج تربة من افران الصهر ومن موقع تجميع حجر البازلت وفق المعايير والمواصفات المعتمدة عالميا لهذا النوع من قياسات النشاط الاشعاعي. وتم قياساها باستخدام منظومة الجرمانيوم عالي النقاوة ذو كفاءة 30% وقدرة فصلkeV 2 للطاقة MeV 1.33 لنظير الكوبلت 60Co , اظهرت نتائج الفحوصات المختبرية لنماذج التربة الماخوذة عدم وجود زيادة ملحوظة في قيم النشاط الاشعاعي النوعي للنويدات المشعة التي تعود الى سلسلتي اليورانيوم-238 والثوريوم-232 واظهرت تراكيز طبيعية لنظير الراديوم -226 خاصةً في النماذج التي تم اخذها من افران الصهر حيث تراوحت بين Bqkg ( 24.1-62.23 ) حيث يعتبر نظير الراديوم-226( ذو عمر نصف 1600 سنة ) من النظائر الباعثة لاشعة الفا وكاما ويتحلل الى غاز الرادون ,وحيث ان ارتفاع تراكيز غاز الرادون هو احد الاسباب الرئيسية المسببة لسرطان الرئة لذا فانه من الضروري استخدام المعدات الوقائية اللآزمة من قبل العاملين في هذه المصانع .


Article
Breast Thickness in Routine Mammogram
الفحص الروتيني لسمك الثدي

Author: Najlaa R.Shareef نجلاء رجب شريف القدسي
Journal: Ibn Al-Haitham Journal For Pure And Applied Science مجلة ابن الهيثم للعلوم الصرفة والتطبيقية ISSN: 16094042 Year: 2014 Volume: 27 Issue: 2 Pages: 103-108
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The purpose of this study was to evaluate the thickness of the compressed breast in mediolateral oblique (MLO) and craniocaudal (cc) mammograms to relate these thickness and breast patterns to mean glandular dose (MAD) in Iraqi women and to evalualat radiology's recommendation for Iraqi women.The study of population consists of 20 paired MLO and CC mammograms obtained on one mammograms unit .The digital read out of compressed breast thickness MGD was calculated by multiplying entrance skin exposure by the exposure-to-absorbed dose conversion factor for the range of breast thickness which was 7.1 ----7.4cm in cc mammograms with a mean breast thickness of 7.2 cm and 7.3 ------7.5 cm in MLO mammograms with a mean breast thickness of 7.52 MGDs in cc and MLO mammograms were 1.89 mGY and 1.99 mGY per view respectively.According to our initial trial, the MGDS OF IRAQI women are lower than recommended by the American collage and UK of radiology.

تضمن البحث حساب سمك الثدي المضغوط بوضعية مائلة لــ(MLO) وبوضعية قائمة مباشرة (CC) في جهاز تصوير الثدي وايجاد العلاقة بين هذه القيم ومعدل الجرعة الغدية (MGD) خلال فحص مجموعة من النساء ومقارنة هذه القيم مع النتائج التي حصل عليها الباحثين في المملكة المتحدة .اجريت الدراسة في مستشفى بغداد التعليمي نوع GIOHO المتطور ، وقد شملت عدد من المرضى بواقع عشرين مريضة وقد استعلمت اقراص الوميض الحراري (TLD) في هذه الفحوصات .قيس سمك الثدي بتطبيق من خلال قوة مناسبة لذلك السمك ومن ثم قياس جرعة الدخول السطحية (ESDPa) ، وحسب معدل الجرعة الغدية AGD بحاصل ضرب (ESDPa) مع مقدار مناسب من عامل التحويل (g) .تمت الدراسة على مجموعتين من سمك ثدي احداهما من (7 - 7.4 cm) في وضعية CC لجهاز فحص الثدي وبمعدل سمك ثدي 7.2 cm ، والاخرى من 7.3 – 7.75 cm بوضعية MLO للجهاز وبمعدل سمك 7.52 cm وقيمة MGD هي 1.89mGY لسمك 7.2 cm و 1.99mGY لمعدل سمك 7.52 cm . والجرعة الغدية MGD لكلا المجموعتين تتراوح من 1.79 – 1.87 ……1.96 mGY) ) على التوالي والمجموعة الثانية من 1.89 – 1.92 ……3 mGY) ) وعند مقارنة هذه النتائج بالذي حصل عليها بعض الباحثين في المملكة المتحدة وجد ان هذه القيم متقاربة جداً .


Article
Determination of the Background Radiation Level in Mosul University Campus Using Multiple Technologies
تحديد مستوى الخلفية الإشعاعية في حرم جامعة الموصل باستخدام تقانات متعددة

Authors: Ammir H. Ali عامر حسن علي --- Ahmed K. Mh احمد خلف محيميد --- Hana I. Hassan هناء إحسان حسن
Journal: Rafidain journal of science مجلة علوم الرافدين ISSN: 16089391 Year: 2014 Volume: 25 Issue: 3A Pages: 86-100
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

The current study aims to determine the background radiation level in Mosul University Campus using multiple technologies, portable detector type Inspector EXP+ containing Geiger-Mueller tube, NaI(Tl) and CR-39 detectors. The portable detector was used to measure the dose rate (Dexp.) at 1 m height from the ground. The radioactivity concentrations of 40K, 222Rn, 226Ra, 232Th, the dose rate (Dcal.) at 1 m height from the ground, radium equivalent activity (Raeq), gamma index (Iγ), alpha index (Iα), external hazard index (Hex), internal hazard index (Hin) and radon exhalation rate (E) were calculated. An empirical equation between the field and the laboratory measurements of the dose rate in air (Dcal., Dexp.) and other equations between (Iγ, Dcal.), (Iγ, Raeq), (Iγ, Hex) and (Raeq, Hex) were found.

يهدف البحث الحالي إلى تحديد مستوى الخلفية الإشعاعية لـ 10 مواقع مختلفة في حرم جامعة الموصل باستخدام تقانات مختلفة وهي الكاشف المحمول Inspector EXP+ الحاوي على أنبوبة عداد كايكر – ميلر و الكاشف الوميضي (NaI(Tl وكاشف الأثر النووي CR-39. تم قياس معدل الجرعة الممتصة لأشعة كاما (Dexp.) في الهواء وعلى بعد متر واحد من سطح الأرض باستخدام الكاشف المحمول وحساب كل من تركيز النشاط الإشعاعي للعناصر المشعة البوتاسيوم 40K والرادون 222Rnوالراديوم 226Ra والثوريوم 232Thومعدل الجرعة الممتصة لأشعة كاما (Dcal.) في الهواء وعلى بعد متر واحد من سطح الارض ومكافئ الراديوم ((Raeq ودليل كاما ((Iγ ودليل الفا (Iα) ومستوى التعرض الداخلي (Hin) والخارجي ((Hex ومعدل التبخر للرادون(E) وإيجاد معادلة تجريبية تربط بين القياسات الحقلية والمختبرية لمعدل الجرعة الممتصة لأشعة كاما في الهواء (Dexp. و Dcal.) ومعادلات أخرى تربط بين (Dcal. و Iγ )، (Raeq و Iγ) ، ( Hex و Iγ) و (Hex وRaeq).

Listing 1 - 7 of 7
Sort by
Narrow your search

Resource type

article (7)


Language

English (5)

Arabic (1)

Arabic and English (1)


Year
From To Submit

2014 (7)