research centers


Search results: Found 7

Listing 1 - 7 of 7
Sort by

Article
Aging effect of different types of composite resin restoration on shear bond strength to different orthodontic adhesives with sapphire bracket (In vitro comparative study)

Authors: Linda B. Jabbar لندا جبار --- Fakhri A. Ali فخري عبد علي
Journal: Journal of baghdad college of dentistry مجلة كلية طب الاسنان بغداد ISSN: 16800087 Year: 2014 Volume: 26 Issue: 2 Pages: 144-149
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: This study was performed to determine the effect of aging of different types of composite materialrestorations on: Shear bond strength (SBS) to light cure and no mix chemical cure orthodontic adhesives withsapphire bracket and the debonding failure sites.Materials and methods: One hundred forty four composite disks were made from three different composite resinmaterials which are: 3M Filtek Z250, 3M filtek Z350 and 3M Valux plus, each group with (48) disks each, thenaccording to the duration of storage each group was subdivided into two equal groups one of them stored for oneday and the other was stored for one month, then each group was further subdivided into two equal subgroups with(12) disks each one bonded with light cure orthodontic adhesive and the other with no mix chemical cure adhesive.The sample was tested for bond strength using the universal testing machine and the Adhesive Remnant Index (ARI)was inspected under the stereomicroscope.Results: The results revealed that there was a highly significant difference among the three types of compositematerials bonded with light cure orthodontic adhesive as showed by ANOVA test, while the T test showed that therewas no significant difference between the two storage durations and also between the two orthodontic adhesivesfor both Filtek Z250 and Valux plus.Conclusions: The highest (SBS) values were obtained from Filtek Z350 samples than other two types of composite. Allthe samples stored for one day showed higher values of (SBS) than those stored for one month


Article
Evaluation of shear bond strength between thermosens as relining material and different denture base materials

Author: Ghazwan Adnan Alkinani غزوان عدنان الكناني
Journal: Journal of baghdad college of dentistry مجلة كلية طب الاسنان بغداد ISSN: 16800087 Year: 2014 Volume: 26 Issue: 4 Pages: 28-31
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: Denture relining is the process of resurfacing of the tissue side of the ill fitting denture, the bond strengthat the relining-denture base interface is most important for denture durability.The aim of present study was toevaluate the shear bond strength between the thermosens as relining material and different denture base materialsthat bonded by thermo fusing liquid. As this corrective procedureis the common chair side procedure in the dentalclinic.Material and method: Sixty samples were prepared and divided into three main groups according to the type ofdenture base materials.Group (A) referred to the heat cure acrylic samples which consisted of 20 samples. Group (B)referred to the high impact acrylic samples which consisted of 20 samples. Group (C) referred to the thermosenssamples which consisted of 20 samples. All groups then subdivided into two groups; each one consists of 10 samples,according to the surface roughness: (A1, B1and C1 for groups with surface roughness and A2, B2 and C2for groupswithout surface roughness). Each sample consisted of two similar parts represent the denture base material eachpart of the sample was designed with dimensions of (70mm X 12mm X 5mmlength, width and depth respectively)having a stopper of depth 3mm. One part of the sample was placed on the other in a manner thatleaving a spacebetween them of dimensions (12mm X 12mm X 3mm length, width and depth respectively) to sandwich the reliningmaterial.Results: The results showed that the thermosens samples had the highest value of shear bond strength followed bythe high impact acrylic samples, then heat cure acrylic samples which had the lowest value of shear bond strength.The results of present study showed that rough samples had reducedshear bondstrength in comparison with thesmooth samples of the same denture base material

خلفیة : تبطین طقم الأسنان ھي عملیة اضافة طبقةالى سطح الطقم المواجھ لانسجة الفم الساندة للطقم ، ان قوة الالتصاقبینمادة التبطین و مادة قاعدة الطقم ھي الأكثر أھمیة بالنسبةلمتانةالطقم. الھدف من الدراسة الحالیة ھو تقییم قوة الالتصاق بین مادة الثیرموسینس كمادة تبطین و مواد قاعدة طقم مختلةتم لصقھا بواسطة سائل الثیرمو فیوشن. و ھذه العملیة التصحیحیةھي من العلاجات الشائعة في عیادة الأسنان .تشیر الى عینات الاكریلیك المعالج بالحرارة التي تتكون ( A ) المواد و طریقة العمل: تم إعداد ستین عینة و تنقسم إلى ثلاث مجموعات رئیسیة وفقا لنوع مواد قاعدةالطقم . المجموعةتشیر إلى عینات الثیرموسینس التي تتكون من 20 عینة . جمیع ( C ) تشیر إلى عینات الاكریلیك عالیة التاثیر التي تتكون من 20 عینة . المجموعة ( B ) من 20 عینة . المجموعة،A تشیر الى مجموعات العینات ذات الاسطح الخشنة و ( 2 (B1 ,C1 ،A المجموعات تم تقسیمھا إلى مجموعتین ؛ تتكون كل مجموعة من 10 عینات ، وفقا لخشونة سطح العینة: ( 15مم X 12 مم X تشیر الى مجموعات العینات ذات الاسطح الصقیلة. تتكون كل عینة من جزأین متماثلین تمثل مادة قاعدة الطقم تم تصمیم كل جزء من العینة مع أبعاد ( 70 مم (C2, B2X 12 مم X طول وعرض وارتفاع على التوالي)مع وجود عتبة من ارتفاع 3مم . یوضع جزء واحد من العینة على الآخر بطریقة تترك مسافة بینھما لتملئ بمادة التبطینبالأبعاد ( 12 مم3مم طول وعرضوارتفاع على التوالي).النتائج: أظھرت النتائج أن عینات الثیرموسینس كانت أعلى قیمة لقوة الالتصاق تلیھا عینات الاكریلیك عالیة التأثیر، ثم عینات الاكریلیك المعالج بالحرارة التي كانت أقل قیمة من قوةالالتصاق. وأظھرت نتائج الدراسة أن قوة الالتصاق قلت فیالعینات ذات الاسطح الخشنة بالمقارنة مع العینات ذات الاسطح الصقیلة من نفس مادة قاعدة الطقم .مفتاح الكلمات:الثیرموسینس وسائل الثیرموفیوشن و قوة الالتصاق.


Article
Shear bond strength of endodontic sealers to dentin with and without smear layer and gutta percha (An in vitro study)

Authors: Rana Kadhim Hasan رنا كاظم حسن --- Majida K. Al-Hashimi ماجدة الهاشمي
Journal: Journal of baghdad college of dentistry مجلة كلية طب الاسنان بغداد ISSN: 16800087 Year: 2014 Volume: 26 Issue: 4 Pages: 86-89
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: The bond strength of root canal sealers to dentin and gutta-percha seems to be an important propertyfor maintaining the stability of root canal filling, which potentially influences both leakage and root strength. Theobjective of this, in vitro, study was to evaluate the shear bond strength of three different endodontic sealers (Gutta-Flow, AH Plus, Apexit Plus) to dentin, in the presence and absence of the smear layer and gutta percha.Material and Methods: After slicing off the occlusal 2mm of 60 extracted human maxillary premolar teeth, theexposed dentin served as the tested surfaces; the teeth were fixed with cold cure acrylic, and were divided into twogroups according to the smear layer presence, group A without smear layer, when dentin surfaces were irrigatedwith EDTA 17% followed by distilled water then subdivided into 3 subgroups according to the type of sealer used;group B when dentin surfaces were washed with distilled water only, then subdivided into 3 subgroups. Thirty samplesof gutta-percha were prepared and named as group C which was subdivided into 3 subgroups. Five mm longsection of polyethylene tubes were placed on the dentin or gutta percha surfaces and filled with freshly mixedsealer. After one week, all the samples were tested for shear bond strength by the Instron Universal Testing Machineat a cross head speed of 0.5 mm/min. The data was calculated in MPa and was statistically analyzedResult: There was a highly significant difference in the shear bond strength (P < 0.05) in comparison among the testedgroups, GuttaFlow showed non-significant difference in bond strength to dentin with and without smear layer, whileAH Plus and Apexit Plus showed a high significant difference.Conclusions: AHPlus showed the highest shear bond strength in all the tested samples, while GuttaFlow was the least.Additionally, AH Plus and Apexit Plus shear bond strengths were affected by the smear layer removal, whileGuttaFlow was not.

صیة مھمة للحفاظ على ثبات حشوة قناة الجذر الذي بدوره یؤثرعلى تسرب و قوة الجذر. Gutta-percha أن لقوة الرابطة لسدادات قناة الجذرالى عاج السن وو عاج السن بوجود اوعدم (AH Plus, Gutta-FlowApexit Plus,) كان الغرض من ھذه الدراسة تقییم قوة الترابط القصي بین ثلاثة انواع من السدادات اللبیة المختلفةبعد قطع 2ملمیتر من تاج 60 سن من أسنان الإنسان(الضواحك العلیا) . تم تثبیت الأسنان في مادة الاكریلیك ، و قسمت .Gutta-percha و ال Smear layer وجود طبقة ال.Smear layer الى مجموعتین وفقا لوجود طبقة ال(AP-) %17 یلیھ الماء المقطر وقسمت إلى 3مجموعات فرعیة وفقا لنوع السدادة المستعملة EDTA على سطح عاج السن مع غسل بمادة Smear layer المجموعة (أ) بدون.D, AH-D, GF-D. APD-S, AHD-S, GFD-S)( المجموعة (ب) غسل سطح عاج السن بالماء المقطر فقط ثم قسمت إلى 3 مجموعات فرعي.(AP-G, AH-G, GF-G) أعدت لتكون المجموعة (ج)وقسمت إلى 3 مجموعات فرعیة (Gutta-percha) ثلاثونعینة مناختبار قوة الرابط القصي تم بعد اسبوع . . Gutta-percha استعمل انبوب بطول 5 ملم من البولي اثیلین بسداده مخلوطة حدیثا ووضع على سطح عاج السن أو السجل فرق معنوي غیر ملحوظ في قوة الترابط مع عاج السن بوجود Gutta-Flow. تم حساب البیانات بوحدة المیغا باسكال و تم تحلیلھا إحصائیاً . أظھرت النتائج فرقا معنویا كبیراسجلوا فرقاً معنویاً عالیاً. Apexit Plus و AH Plus بینما Smear layer اوعدم وجود التأثرت Apexit plus و AH Plus الاقل بینھم . وقوة الربط القصي لل Gutta-Flow اظھر اعلى قوة ربط قصي في جمیع العینات بینما كان AH Plus : الاستنتاج النھائيفلم تتأثر.


Article
Effect of zirconia surface treatments on the shear bond strength of veneering ceramic

Authors: Inas H. Kareem --- Haitham J. Al-Azzawi هيثم جاسم العزاوي
Journal: Journal of baghdad college of dentistry مجلة كلية طب الاسنان بغداد ISSN: 16800087 Year: 2014 Volume: 26 Issue: 3 Pages: 13-17
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: The aim of the study was to investigate the effect of surface treatments of zirconia (grinding andsandblast with 50μm, 100 μm) on shear bond strength between zirconia core and veneering ceramic.Material and methods: Twenty-eight presintered Y-TZP ceramic specimens (IPS e.max ZirCAD, Ivoclar vivadent) werefabricated and sintered according to manufacturer’s instructions. The core specimens were divided randomly in to 4groups, group 1: no surface treatment, group2: zirconia specimens were ground with silicon carbide paper up to1200grit under water cooling, group3: zirconia specimens were ground and sandblast with 100 μm alumina, group 4:zirconia specimens were ground and sandblast with 50 μm alumina. Surface roughness of specimens were analyzedby surface profilometer, then veneering ceramic (IPS e.max ceramic, Ivoclar vivadent) was applied on thespecimens& fired according to manufacturer’s instructions. All specimens were subjected to shear force in a universaltesting machine at a crosshead speed of 1mm/min. The shear bond strength values were analyzed with one-wayANOVA; the fractured surfaces were examined with a stereo-microscope to observe the failure mode.Results: The mean of shear bond strength values in MPa were 24.75 for group 4, (17.72) for group 3, (17.68) for group2,(14.61) for group 1.The airborne-particle abrasion with 50μm group showed significantly higher bond strength thanother groups. The airborne-particle-abraded with 100 μm group was not significantly different from grinding group.Conclusion: With limit of this study, the sandblast with 50 μm alumina was enhance the SBS between zirconia&veneering ceramic, and zirconia-veneering ceramic bonding is not only influenced by surface roughness. But alsomay be other factors

الغرضمن ھذه الدراسھ لفحصتأثیر الطرق المختلفھ لمعاملھ السطح لماده الزركونیم على قوه الربط القصي بین ھیكل الزركونیم وقشره السیرامیك .تم تحضیر ثمان وعشرین عینھ من ماده الزركونیم (زركاد ,ایماكس ,ایفوكلار فیفادینت) حسب تعلیمات المصنّع،وتم توزیع العینات عشوائیاً الى اربع مجامیع:المجموعھ الاولى:لا توجدمعاملھ للسطح ، المجموعھ الثانیھ::شحذ(حك) العینات بأستخدام اوراق الحك(سیلكون كارباید) تدریجیا الى الحجم 1200 مایكرومیتر,المجموعھ الثالثھ :حك العینات ثم تخدیشھا بواسطھالالومینیوم اوكساید حجم ( 100 مایكرون)، المجموعھ الرابعھ: حك العینات ثم تخدیشھا بواسطھ الالومینیوم اوكساید حجم ( 50 مایكرون)، بعد عملیات الحك والتخدیش یتم فحصخشونھ سطح العینات بواسطھ جھاز قیاس خشونھ السطح(البروفایلومیتر)، ثم تم بناء ماده السیرامیك على جمیع العینات ثم تم صھر ماده السیرامیك حسب تعلیمات المصنّع،تم قیاس قوهاحادي الاتجاه، ثم تم فحص العینات بواسطھ المایكرسكوب(ستیریو مایكرسكوب) لتحدید نوع الكسر لكل ANOVA الربط باستخدام جھاز(الانسترون)،تم اجراء الاحصائي بواسطھعینھ.اظھرت النتائج ان معدل قوه الربط للمجموعھ الرابعھ( 24,75 ) میكاباسكال,وللمجموعھ الثالثھ( 17,72 ) میكاباسكال,وللمجموعھ الثانیھ ( 17,68 ) میكاباسكال،وللمجموعھ الاولى(14,61 ) میكاباسكال، قوة الربط للمجموعھ الرابعھ مجموعھ الحك ثم التخدیش ب 50 مایكرون) كانت اعلى من المجامیع الاخرى,واظھرت النتائج انھ لایوجد فرق بین المجموعھالثالثھ(مجموعھ الحك ثم التخدیش ب 100 مایكرون) والمجموعھ الثانیھ(مجموعھ الحك فقط).ضمن حدود ھذه الدراسھ فان عملیھ التخدیش ب 50 مایكرون بعد عملیھ الحك تزید قوه الربط بین ھیكل الزركونیم و قشره السیرامیك,وقد اظھرت الدراسھ ان قوه الربط بین المادتین لاتتأثر فقط بخشونھ سطح الزركونیم .


Article
Effect Of Surface Treatment on Shear Bond Strength of Acrylic Resin to Cobalt-Chromium Alloy

Author: Mohammed M.Sadoon
Journal: Al-Rafidain Dental Journal مجلة الرافدين لطب الأسنان ISSN: 18121217 Year: 2014 Volume: 14 Issue: 2 Pages: 252-258
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Aims: to evaluate the effect of metal primer with acid etch, laser beam, and sand blasting on shear bond strength(SBS) or resin metal and surface roughness(SR). Materials and methods: fifty Co-Cr metal plate were prepared with 10X10X1 mm dimensions. These metal plates were divided in to 5 groups control (without treatment), acid etched with hydrochloric acid(10%) with metal primer(AP), laser beam with metal primer(LP), sand blasting with metal primer(SP), and metal primer alone(P). These groups were tested for shear bond strength of resin to metal and surface roughness. Results: there are a significant differences in shear bond strength of all treated groups in contrast to control groups, and the AP had the highest shear bond strength value. While surface roughness of tested samples shows the control group smoothest surface in relation to other groups and there is no significant difference with metal primer only and the AP group had higher surfaces roughness. Conclusion: metal primer improve bond strength between Co-Cr and chemical cured acrylic resin, the treating surface with HCL acid increase SBS and SR of metal plate. The roughening of metal surface by different treatment ( P, AP, LP, and SP) improve the SBS of metal bond to resin.


Article
The effect of plasma treatment on shear bond strength of soft denture liner with two different types of denture base material (heat cure and light cure)

Authors: Zainab S. Abdullah زينب عبد الله --- Wasmaa S. Mahmood وسماء محمود --- Rafah A. Ibrahem
Journal: Journal of baghdad college of dentistry مجلة كلية طب الاسنان بغداد ISSN: 16800087 Year: 2014 Volume: 26 Issue: 2 Pages: 44-49
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: In this study we evaluate the effect of plasma treatment (oxygen and argon) gas in two differentexposure times on the surface of heat cure and light cure acrylic resin.Materials and method: 100 specimens of heat cure and light cure acrylic resin were fabricated. The measurements ofthe samples were (75mm, 25mm and 4.5mm) length, width and depth respectively with stopper of 3mm depth. Twotypes of gas used oxygen and argon in (5,10) min by using (DC-glow discharge plasma device) then we apply coldcure soft lining material, with the help of Instron machine we test the shear stress value.Results: A highly significant effect after argon and oxygen gases treatment in both 5 and 10 min exposure times onshear bond strength to soft liner in heat cure denture base material.Conclusion: In this study we found that the exposure of heat cure acrylic resin to plasma gases (argon and oxygen)increase the shear bond strength (SBS) values significantly


Article
The effects of various beverages on the shear bond strength of light-cured orthodontic composite (An in vitro comparative study)

Author: Mohammed Nahidh محمد ناهض محمد حسن
Journal: Journal of baghdad college of dentistry مجلة كلية طب الاسنان بغداد ISSN: 16800087 Year: 2014 Volume: 26 Issue: 3 Pages: 144-148
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: This study was conducted to assess the effects of various beverages on the shear bond strength of lightcuredorthodontic composite used to bond stainless steel orthodontic brackets on human teeth and to determinethe site of bonding failure of this material.Materials and Methods: Fifty extracted human premolars were selected and randomly divided into five equal groupseach with 10 teeth according to the beverage type (Control, One Tiger, Milk, Green tea and Coffee). After bonding,the teeth were immersed in specific beverages for 5 minutes twice daily with equal intervening intervals then washedand stored in distilled water at 37º C for the reminder of the day. The process was carried out for 30 days. Thesamples were then tested for shear bond strength using Tinius-Olsen testing machine with a crosshead speed of0.5mm/minute. For adhesive remnant index, the enamel surface and bracket base of each tooth were inspectedunder magnifying lens (20X) of a stereomicroscope.Results: Milk, coffee and one Tiger energy drink reduced the shear bond strength of the light-cured compositesignificantly unlike the green tea. The predominant site of bond failure was between the bracket base and theadhesive leaving the composite on the tooth rather on the brackets base.Conclusions: Orthodontic patients should be instructed to reduce the intake of acidic and fatty beverages toprevent debonding of the orthodontic brackets

الخلفیة : أجریت ھذه الدراسة لتقییم تأثیر المشروبات المختلفة على القوة القاصة لحاصرات تقویم الاسنان الفولاذیة ، وتحدید موقع فشل الارتباط مع الاسنان.المواد و الأسالیب: تم اختیار خمسون من الضواحك البشریة والتي قسمت عشوائیا إلى خمس مجموعات متساویة كل منھا 10 اسنان وفقا لنوع الشراب (ماء مقطر ، مشروب الطاقةوقد º النمر الاول ، الحلیب ، الشاي الأخضر والقھوة ). تم غمر الاسنان في المشروبات لمدة 5 دقائق مرتین یومیا ثم تم غسلھا وتخزینھا في الماء المقطر في درجة حرارة 37أجریت عملیة لمدة 30 یوما . تم اختبار القوة القاصة لحاصرات تقویم الاسنان باستخدام آلة اختبار خاصة و بمعاییر معینة.النتائج: كانت القوة القاصة لحاصرات تقویم الاسنان الفولاذیة في الحلیب ، القھوة و مشروب الطاقة النمر الاول اقل بشكل ملحوظ مما ھي علیھ في المجموعة الضابطة على عكسالشاي الأخضر.الاستنتاجات : یجب الاقلال من تناول المشروبات الحمضیة والدھنیة لمرضى تقویم الأسنان.

Listing 1 - 7 of 7
Sort by
Narrow your search

Resource type

article (7)


Language

English (7)


Year
From To Submit

2014 (7)