research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Experimental Performance of a Finned-tube Silica Gel Adsorption Chiller for Air-Conditioning Application
الأداء التجريبي لمبرد امتزازي ذو انبوب زعنفي للسيلكا جل لاغراض تبريد الهواء

Authors: Mohammed A. Atiya --- Farkad A. Lattieff فرقذ علي لطيف --- Adil A. Al-Hemiri عادل احمدعوض
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2014 Volume: 10 Issue: 3 Pages: 68-77
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This work presents the construction of a test apparatus for air-conditioning application that is flexible in changing a scaled down adsorbent bed modules. To improve the heat and mass transfer performance of the adsorbent bed, a finned-tube of the adsorbent bed heat exchanger was used. The results show that the specific cooling power (SCP) and the coefficient of performance (COP) are 163 W/kg and 0.16, respectively, when the cycle time is 40 min, the hot water temperature is 90oC, the cooling water temperature is 30oC and the evaporative water temperature is 11.4oC.

يعرض هذا البحث بناء جهاز اختبار لمنظومة تبريد الهواء يتسم بالمرونة في تغيير موديل وحدة الامتزاز. فمن اجل تحسين كفاءة انتقال الحرارة والمادة، تم استخدام مبادل حراري مزود بزعانف لوحدة الامتزاز . أظهرت النتائج أن سعة التبريد (SCP) ومعامل الأداء (COP) هي 163 واط / كجم و 0.16، على التوالي، عندما يكون وقت الدورة هو 40 دقيقة، ودرجة حرارة الماء الساخن 90 درجة مئوية،ودرجة حرارة مياه التبريد 30 درجة مئوية ودرجة حرارة الماء المبرد 11.4 درجة مئوية.


Article
Modification Of The Granular Activated Carbon And Its Effect On Removal Of Cr(VI) From Aqueous Solution In Batch And Fixed-Bed Systems
تطوير الكاربون المنشط وتأثير ذلك على إزالة الكروم السداسي من المحلول الملوث باستخدام أنظمة الدفعة الواحدة والمستمرة

Loading...
Loading...
Abstract

The adsorption processes of Cr(VI) from aqueous solution onto a granular activated carbon (GAC) and a modified granular activated carbon (MGAC) with AgNNO3, FeCL3 and Na2EDTA have been investigated. The surface characteristics of these activated carbons were measured. The results showed that the MGAC has a lower surface area and more active functional groups compared with the GAC. Adsorption parameters such as adsorbent dosage, pH of solution, temperature and contact time of the adsorption onto GAC and MGAC have been investigated in a batch adsorption experiments in order to obtain the optimum conditions for the Cr(VI) adsorption process. Thermodynamic modeling using temperatures studies was done to reveal the nature of adsorption which indicated that the process was spontaneous and physical in nature. Experimental equilibrium data have been obtained and correlated with Langmuir and Freundlich isotherms for the determination of the adsorption potential. The results have shown that the Langmuir isotherm model better fits the experimental data compared with the Freundlich isotherm for both GAC and MGAC. It was found that the MGAC has a higher Cr(VI) adsorption capacity (qm), with 11.082, 14.214, 25.842, 25.842 mg/g for GAC, (Ag+1-GAC), (Na+1-GAC) and (Fe+3-GAC) respectively. The breakthrough curves for the adsorption column test was obtained in a continuous adsorption fixed-bed experiment, The measured breakthrough times for GAC, (Ag+1-GAC), (Na+1-GAC) and (Fe+3-GAC) were found to be 10, 30, 40 and 60 min, respectively.

تناول هذا البحث عملية الامتزاز للكروم السداسي باستخدام الكاربون المنشط الحبيبي والكاربون المنشط الحبيبي المعامل كيماويا باستخدام AgNNO3, FeCL3 ,Na2EDTA. تم قياس الخواص السطحية لأنواع الكاربون المنشط بنوعية الاعتيادي والمطور. بينت النتائج أن الكاربون المنشط الحبيبي المطور (MGAC) يمتلك مساحة سطحية أقل ومجاميع فعاله أكثر نشاطاَ. محددات الامتزاز مثل جرع المادة المازه، درجة حموضة السائل، درجة الحرارة و وقت التلامس باستخدام (GAC) و (MGAC) تم دراستها بتجارب الامتزاز ذو الدفعة الواحدة للحصول على أفضل الظروف لعملية امتزاز الكروم السداسي. موديل الثرموداينمك باستخدام تجارب درجة الحرارة تم إنجازها لإيجاد وتحديد نوعية عملية الامتزاز فوجد أنها من نوع التفاعلات التلقائية والفيزيائية بطبيعتها. بيانات تجارب التوازن تم أيجادها وتم ربطها باستخدام موديلات لآنكَمير وفريندلج. النتائج أظهرت أن موديل لآنكَمير يحقق أفضل توافق مع النتائج العملية بالمقارنة مع موديل فريندلج لكلا النوعين، الكاربون المنشط الحبيبي والمطور. وتم استنتاج أن الكاربون المنشط الحبيبي المطور يمتلك سعه امتزاز أكبر للكروم السداسي وكالتالي : 35.461, 25.842, 14.214, 11.082 ملغم/غم لكل من GAC، Ag+1-GAC، Na+1-GAC، Fe+3-GAC على التوالي .تم الحصول على منحنيات الانكسار من التجارب ذات النمط المستمر على عمود الامتزاز الثابت .تم إيجاد أوقات الانكسار المقاسة لكل من GAC، Ag+1-GAC، Na+1-GAC، Fe+3-GAC لتكون 10، 30، 40، 60 دقيقة على التوالي. كلمات دالة : الامتزاز، الكاربون المنشط الحبيبي، الكاربون المنشط الحبيبي المطور، الكروم السداسي، نظام الدفعة المتقطعة، نظام الدفعة المستمرة.

Keywords

Keywords: Adsorption --- GAC --- MGAC --- Cr --- VI --- FTIR --- Batch system --- Fixed-bed system.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic and English (2)


Year
From To Submit

2014 (2)