Decreasing the Pollution with Coliform in the Wastewater by Using Ultrasound Waves
خفض التلوث ببكتريا القولون في مياه الصرف الصحي باستخدام الموجات فوق الصوتية

Loading...
Loading...
Abstract

The aim of this study is to use Ultrasound waves in decreasing the pollution with Coliform bacteria in the wastewater which have the ability to kill bacteria exist in the clay. Thirty samples were collected from wastewater station in Baghdad UniversityScience Collage for Women. Samples exposed to ultrasound waves for diffrent times, the results showed decreases in the total coliform count with increasing time of exposure compared with samples before exposure, except exposure to(10) minutes that showed increases in total coliform count because of releasing bacteria from clay as a results of particles disintegration by ultrasound waves. other exposure times showed kill rate as follows: (15)min./(6.66%),25min./(13.33%),35min./(33.33%),45min./(64.28%),50min./(86.64%),60min./(90.21%),80min./(93.18%),90min./(97.81%),100min./(99%),120min./ (99.97%). These results showed that using ultrasound waves has the ability to rednce wastewater pollution with the colifom and can be used with other treatment methods to reduce chemical material that be used to kill bacteria.

تهدف الدراسة الى استخدام الموجات فوق الصوتية لتقليل التلوث ببكتريا القولون في مياه الصرف الصحي حيث لها القدرة على قتل البكتريا المتواجدة في الاطيان . جمع ثلاثون نموذج من محطة تجميعية لمياه الصرف الصحي في جامعة بغداد/كلية العلوم للبنات ومن ثم عرضت النماذج للموجات فوق الصوتية لعدة فترات زمنية. اشارت النتائج تناقص في اعداد بكتريا القولون الكلي مع زيادة فترة التعرض مقارنة مع اعداد بكتريا القولون الكلي ماقبل التعرض للموجات فوق الصوتية ماعدا الفترة عشر دقائق التي اظهرت زيادة في اعداد هذه البكتريا بسبب تفتت الجسيمات والاطيان بالموجات فوق الصوتية وتحرر البكتريا المتواجدة داخلها الى الماء، اما الفترات (15, 25, 35, 45, 50, 60, 80, 90, 120) دقيقة فكانت نسبة القتل لكل فترة: 6.66%, 13.33%, 64.28%, 86.64%, 90.21%, 93.18%, 97.81%, 99%, 99.97%على التوالي. النتائج توضح كفاءة الطريقة في خفض نسبة تلوث مياه الصرف الصحي ببكتريا القولون وبالامكان استخدامها مع طرق المعالجة الاخرى لتقليل المواد الكيميائية المستخدمة في قتل هذه البكتريا.


Article
The Impact of the Sodium Thiocyanate on Preserving the Raw Cow Milk
تأثير ثايوسينيت الصوديوم في حفظ حليب الابقار الخام

Authors: Najim Hadi Najim نجم هادي نجم --- Mohamed Khadum Wali محمد كاظم والي
Journal: AL-Qadisiyah Journal For Agriculture Sciences مجلة القادسية للعلوم الزراعية ISSN: Online ISSN: 26181479 Print ISSN: 20775822 Year: 2015 Volume: 5 Issue: 2 Pages: 1-8
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

The present study is planned to evaluate the keeping quality of raw milk by activation of its natural lactoperoxidase system (LPS) at about 3 h of the morning milking. The raw milk samples (about one liter each) are collected from the animal field of college veterinary university of Baghdad.The present study shows the significant increase (p˂0.05) in the total aerobic bacterial counts and coliform counts of control milk samples under storage temperatures. The average mean log value of total aerobic bacterial count increases significantly in the control milk samples from the starting initial count of 6.757 to 9.158 and 8.259 cfu/ml after 48 h of milk storage at ambient and refrigeration temperatures respectively. There is significant reduction from 9.158±0.379 cfu/ml in the control milk sample to 6.593±0.126 cfu/ml in stabilized milk sample that storage at ambient temperature and from 8.259±0.135 cfu/ml to 6.266±0.125 cfu /ml in control milk sample storage at refrigerated temperature after 48hours. Average mean log value of coliform count is increased significantly in the control milk samples from the starting initial count of 4.852 to 7.387 and 6.933 cfu/ml after 48 hours of milk storage at ambient and refrigeration temperatures respectively . There is significant reduction from 7.387±0.053 cfu/ml in the control milk sample to 4.852±0.170 cfu/ml in stabilized milk sample that storage at ambient temperature and from 6.933±0.177 cfu/ml to 5.066±0.061 cfu/ml in control milk sample storage at refrigerated temperature after 48hours.

صممت الدراسة الحالية لتقييم حفظ جوده الحليب من خلال تنشيط نظام اللاكتوبيروكسيديز الطبيعي(LPS) بعد مرور ثلاث ساعات من الحلبة الصباحية. جمعت خمسة عينات الحليب لمدة خمسة اسابيع من حقل الحيواني لكلية الطب البيطري جامعة بغداد.أظهرت الدراسة ان هناك زيادة معنوية في العدد الكلي لكل من البكتريا الهوائية وبكتريا القولون عبر الفترات الزمنية الاربعة لحفظ جميع عينات الحليب لمجموعة السيطرة سواء كان حفظها عند درجة حرارة الغرفة او الثلاجة .ازداد متوسط القيمة اللوغارتمية للعدد الكلي للبكتريا الهوائية معنويا في جميع عينات حليب مجموعة السيطرة من العدد لابتدائي لانطلاق التجربة وهو 6.757 الى 9.158 و 8.259(cfu/ml) بعد 48 ساعة من حفظ الحليب عند درجة حرارة الغرفة والتبريد بالثلاجة على التوالي,ولاحظ هبوط معنوي في اعداد البكتريا الهوائيه من 9.158±0.379 log cfu/mlمن مجموعه السيطرة الى6.593± 0.126 cfu/ml من مجموعه التنشيط وفي درجه حرارة الغرفه ومن 8.259±0.135 cfu/ml من مجموعه السيطرة الى 6.266±0.125 cfu/ml من مجموعه التنشيط وفي درجه حرارة الغرفة بعد 48 ساعة من حفظ الحليب . كذلك ازداد متوسط القيمة اللوغارتمية للعدد الكلي لبكتريا القولون بصورة معنوية في جميع عينات الحليب لمجموعة السيطرة من العدد لابتدائي لانطلاق التجربة وهو4.852 الى7.387 و6.933(cfu/ml) بعد 48 ساعة من حفظ الحليب عند درجة حرارة الغرفة والتبريد بالثلاجة على التوالي. ولاحظ هبوط معنوي في اعداد البكتريا القولونية من 7.387±0.053 cfu/mlمن مجموعه السيطرة الى cfu/ml 4.852±0.170من مجموعه التنشيط في درجه حرارة الغرفه ومن 6.933±0.177 cfu/ml من مجموعه السيطرة الى 5.066±0.061 cfu/ml من مجموعه التنشيط وفي درجه حرارة التبريد بعد 48 ساعة من حفظ الحليب