research centers


Search results: Found 16

Listing 1 - 10 of 16 << page
of 2
>>
Sort by

Article
Flow Injection- Spectrophotometric Determination of Vancomycin Hydrochloride in Pharmaceutical Preparations Using Diazotized Metoclopramide

Authors: Mouyed Q. Al-Abachi --- Hind Hadi --- Fadi J. Yousef
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2015 Volume: 18 Issue: 1 Pages: 9-19
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

A batch and flow injection analysis (FIA) spectrophotometric methods have been developed for the determination of vancomycin hydrochloride (VHC) in aqueous solution and in pharmaceutical preparations. The methods are based on the reaction of VHC with diazotized metoclopramide (DMCP) in alkaline medium. The water soluble yellowish-orange color product was measured at λmax 451 nm. Linearity was observed from 0.5 to 100 and 1 to 550 µg mL−1 of VHC with detection limits of 0.230 and 0.419 µg mL−1 by batch and FIA procedure respectively. The sampling rate was 128 injections per hour for flow injection methods. The effects of chemical and physical parameters have been carefully considered and the proposed procedures were successfully applied to the determination of VHC in pharmaceutical formulations.

يتضمن البحث تطوير طريقتين طيفيتين باستخدام نظام الدفعة والتحليل بالحقن الجرياني لتقدير الفانكومايسين هيدروكلورايد في المحاليل المائية والمستحضرات الصيدلانية. تعتمد الطريقتان على تفاعل الفانكومايسين هيدروكلورايد مع كاشف الميتوكلوبرامايد المؤزوت في الوسط القاعدي. تم قياس الناتج البرتقالي المصفر الذائب في الماء عند طول موجي 451 نانومتر. بلغت مديات الخطية من 0.5 الى 100 ومن 1 الى 550 مايكروغرام.مل-1 وبحدود كشف 0.230 و0.419 مايكروغرام.مل–1 لطريقتي الدفعة والحقن الجرياني على التوالي. بلغ معدل النمذجة 128 نموذج بالساعة لطريقة الحقن الجرياني. تمت دراسة تاثير جميع المتغيرات الفيزيائية والكيميائية على الطرق المقترحة وتم تطبيق الطريقة بنجاح في تقدير الفانكومايسين هيدروكلورايد في مستحضراته الصيدلانية.


Article
Flow Injection Determination of Thymol in Pharmaceutical Samples Via Oxidative Coupling Reaction with 2,4- Dinitrophenylhydrazine

Authors: Mouayed Q.Al-Abachi --- Hind Hadi --- Ghadah Fadhil
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2015 Volume: 18 Issue: 2 Pages: 18-24
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

A fast and sensitive flow injection analysis (FIA) method for the quantitative determination of thymol (THY) in raw and pharmaceutical formulations have been proposed. The method is based on coupling reaction between THY and 2,4-dinitrophenylhydrazine in alkaline medium with presence of potassium periodate to form an intense violet water-soluble dye that is stable and has a maximum absorption at 570 nm. A graph of absorbance versus concentration indicates that Beer’s law is obeyed over the concentration range of 10-150 μg.mL-1 of THY, with detection limit of 5 μg.mL-1and sample throughputs of 60h-1. The proposed method was successfully applied to the determination of THY in mouth wash preparations.

يتضمن البحث وصف طريقة طيفية لتقدير للثايمول باستخدام تقنية الحقن الجرياني. اعتمدت الطريقة على ازدواج المستحضر المذكور مع كاشف 4,2- ثنائي نيترو فنيل هيدرازين في الوسط القاعدي بوجود بيرايودات البوتاسيوم لتكوين ناتج مستقر بنفسجي اللون يعطي أقصى امتصاص عند طول موجي 570 نانومتر. يشير الرسم البياني للامتصاص مقابل التركيز بان قانون بير ينطبق ضمن المدى 10- 150 مكغم مل1- من الثايمول وبحد كشف 5 مكغم مل1-وبمعدل نمذجة حوالي 60 عينة بالساعة 0 تم تطبيق الطريقة المقترحة بنجاح في تقدير االثايمول في غسولات الفم.


Article
Determination of hydrogen peroxide in some local pharmaceutical disinfectants by continuous flow injection analysis via turbidimetric (T180o) and scattered light effect at two opposite positions (2N90o ) using Ayah 4SW-3D-T180o -2N90o -Solar - CFI Analyser
تقدير بيروكسيد الهيدروجين في بعض المطهرات الصيدلانية باستخدام تحليل الحقن الجرياني المستمر عن طريق قياس التعكريه (T180° ) وتأثير استطاره الضوء عند اتجاهين متعاكسين (2N90° ) باستخدام المحلل Ayah 4SW-3D-T180o -2N90o -Solar - CFI

Authors: Nagam S. Turkey Al-Awadie نغم شاكر تركي العوادي --- Ahmed F. Khudhair أحمد فاضل خضير
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 1C Pages: 577-592
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An indirectly method is used to determine hydrogen peroxide. The method based on oxidation of chromium (III) ion by hydrogen peroxide in basic medium to form chromate ion which react with barium (II) ion to produce a yellow precipitate (BaCrO4). Under the optimum established conditions, the linear range of 0.50-25.00 mmol L-1 along with correlation coefficient (r) of 0.9992, Limit of detection (LOD) 0.68 µg / 100 µL, precision expressed as relative standard deviation for six replication measurements at 5.0 mmol.L-1 H2O2 of less than 2% were obtained for hydrogen peroxide. The developed method was successfully applied for the estimation of H2O2 in three pharmaceuticals preparation of different companies using continuous flow injection or stop-flow injection technique.

تم التقدير غير المباشر لبيروكسيد الهيدروجين من خلال تكوين راسب أصفر من كرومات الباريوم الناتج من اكسدة آيون الكروم (III) بأستعمال بيروكسيد الهيدروجين في الوسط القاعدي لتكون آيون الكرومات الذي يتفاعل مع آيون الباريوم(II) اذ كان مدى الخطية لمحلول بيروكسيد الهيدروجين بين (0.50-25.00) مللي مول.لتر-1 مع معامل الارتباط (r) 0.9992 , تم الحصول على حد كشف (L.O.D) 0.68 مايكروغرام 100 مايكرولتر و الانحراف القياسي النسبي المئوي لتركيز 5.0 مللي مول.لتر-1 أقل من 2% (n = 6). طبقت الطريقة بنجاح لتقدير بيروكسيد الهيدروجين في ثلاث مستحضرات صيدلانيه( شركات مختلفه) باستخدام جريان مستمر او جريان توقف.


Article
A new mode for an on-line determination of Pyrocatechol, Resorcinol, and Pyrogallol in pure commercial samples using CFIA with homemade Ayah 3SBGRx3- 3D solar cell microphtometer analyzer
نمط جديد للتقدير الأني للبايروكتكول, ريزورسينول و البايروكالول في نماذج تجارية النقية بأستخدام التحليل بالحقن الجرياني المستمر عن طريق استخدام محلل طيفي مايكروي مصنع محليا Ayah 3SBGR x3-3D solar cell.

Authors: Malik H. AlalooshAlamri مالك حسين العلوش العامري --- Nagam S. TurkieAl-Awadie نغم شاكر تركي العوادي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 2A Pages: 875-897
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A new, simple, accurate, fast and sensitive spectrophotometric method has been developed for the analysis of Pyrocatechol, Resorcinol, and pyrogallolin pure commercial samples by continuous flow injection analysis. The method was based on the oxidation of the organic compounds with Ce(IV)sulfate in acidic medium to formed a brown colored species which determined using homemade Ayah 3SBGR x3-3D solar cell flow injection microphotometer. Optimum conditions were obtained using a high intensity green light emitted diode as an irradiation source forPyrocatechol, Resorcinol, whileblue light emitted diode as an irradiation source for pyrogallol. The linear dynamic range for the instrument response versus Pyrocatechol, Resorcinol, and pyrogallol concentrationswere5-40mmol.L-1 while the L.O.D was of 36.63, 17.17, and 41.61ng / sample respectively. The correlation coefficient (r) was 0.9952, 0.9970, and 0.9960 while percentage linearity (r2%) was 99.05%, 99.41% and 99.22%forPyrocatechol, Resorcinol, and pyrogallol respectively. RSD% for the repeatability (n=8,7, and 8) was 1.4%, 0.63%, 1.78% for the determination of Pyrocatechol, Resorcinol,andpyrogallol, respectively at concentration of 30 mmol.L-1. The method was applied successfully for the determination of three organic compounds in purecommercial samples. A comparison was made between the newly developed method and the classical method (UV-Vis spectrophotometry) at wave length 492, 481, and 438 nm forPyrocatechol, Resorcinol and pyrogallolrespectively of analysis using the standard additions method via the use of paired t-test. It was noticed that there is no significant difference between two different methods for analysis three different organic compounds; in addition to no significant difference in the contribution of the Pyrocatechol, Resorcinol and pyrogallol to the oxidant reaction path, at 95% confidence level.

طورت طريقة طيفية جديدة, بسيطة, سريعة, مظبوطة, وحساسة لتحليل البايروكتكول, الريزورسينول, والبايروكالول في نماذج تجارية نقية بأستخدام التحليل بالحقن الجرياني المستمر. استندت الطريقة على اكسدة المركبات العضوية بكبريتات السيريوم (IV) في الوسط الحامضي لتكوين اصناف ملونة بنية والتي قدرت بأستخدام مطياف مايكرويبالحقن الجرياني المستمر مع Ayah 3SBGR x3-3D solar cell المصنع محليا. تم دراسة الظروف الفضلى التي تم التوصل اليها بأستخدام ثنائي الوصلة باعث للضوء الاخضر وبشدة عالية كمصدر لتشعيعالبايروكتكول والريزورسينول, بينماثنائي الوصلة باعث للضوء الازرق وبشدة عالية كمصدر لتشعيع البايروكالول . المدى الخطي الفعال لعلاقة تغير الاستجابة الألية مع التركيز 5- 40 مللي مول.لتر-1 بينما حدود الكشف,17.17 ,36.63 41.61 ناغم / انموذج. وان معامل الارتباط (r) 0.9952, 0.9970, و 0.9960 بينما نسبة الخطية r2 % = 99.05, 99.41, و 99.22. الانحراف القياسي النسبي المؤي (RSD%) للتكرارية(n= 8,7,8)1.4, 0.63, 1.78 % لمحلول البايروكتكول, الريزوسينول, والبايروكالول بتركيز 30 مللي مول .لتر-1للبايروكتكول, الريزوسينول والبايروكالول طبقت الطريقة بنجاح لتقديرالمركبات العضوية الثلاثة في نماذج تجارية نقية. اجريت مقارنة بين الطريقة المطورة والطريقة التقليدية (مطيافية UV-Vis) عند طول موجي 438, 481,و 492 نانو متر للتحليل باستخدام منحني الاضافات القياس من خلال استخدام اختبار t- المزدوج. لوحظ انه لايوجد فرق جوهري بين الطريقتين لتحليل المركبات العضوية الثلاثة بالاضافة الى عدم الاختلاف في مساهمة كل من البايروكتكول , الريزورسينول و البايروكالول على مسار تفاعل الاكسدة عند مستوى قناعة 95%.


Article
Turbidimetric Determination of Metoclopramide Hydrochloride in Pharmaceutical Preparation via the Use of A new Homemade Ayah 6SX1-T-2D Solar Cell-Continuous Flow Injection Analyser
التقديرالتعكري لميتاكلوبراميد هايدروكلوريد في المستحضرات الصيدلانية من خلال استخدام محلل جديد مصنع محليا للحقن الجرياني المستمر Ayah 6SX1-T-2D Solar cell

Authors: Nagam S. Turkie Al-Awadie نغم شاكر تركي العوادي --- Kefah H. Ismael Al-saadi كفاح حسن اسماعيل الساعدي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 2B Pages: 1224-1240
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A newly developed analytical method characterized by its speed and sensitivity for the determination of metoclopramide hydrochloride (MCP-HCl) in pure and pharmaceutical preparation via turbidimetric measurement (0-180o) by Ayah 6SX1-T-2D Solar cell-CFI Analyser. The method was based on the reaction of phosphomolybdic acid with metoclopramide hydrochloride in acidic medium to form yellowish white precipitate for the ion-pair complex. Turbidity was measured via the reflection of incident light that collides on the surface precipitated particles at 0-180o. Chemical and physical parameters were studied and optimized. The calibration graph was linear in the range of 0.0005-3 or 0.0005- 4 mMol.L-1, with correlation coefficient r = 0.9947&0.9845 respectively. The limit of detection 3.543 ng/sample from the step wise dilution for the minimum concentration in the linear dynamic ranged of the calibration graph with RSD% lower than 0.3% for 1, 3 mMol.L-1 (n=8) concentration of metoclopramide hydrochloride . The method was successfully applied to the determination of metoclopramide hydrochloride in three pharmaceutical drugs. A comparison was made between the newly developed method analysis with the classical method (HANNA instrument for turbidity measurement) using the standard addition method via the use of t-test. It was noticed that there was no significant difference between two methods at 95 % confidence level.

طورت طريقة تحليلية جديدة ,تميزت بالسرعة والحساسية لتقدير الميتاكلوبراميد هيدروكلورايد بشكلة النقي او على هيئة مستحضرات صيدلانية عن طريق قياس التعكرية 0-180º بوساطة محلل الحقن الجرياني المستمرAyah 6SX1-T-2D Solar cell .استندت الطريقة على تكوين راسب ابيض مصفر لمزدوج ايوني بين الميتاكلوبراميد هيدروكلورايد وحامض مولبدات الفسفوريك في الوسط الحامضي . تم قياس التعكرية عن طريق انعكاس الضوء المسلط والمصطدم بسطوح دقائق الراسب بزاوية 0-180º. تم دراسة كافة المتغيرات الكيميائية والفيزيائية . مدى الخطية لمنحني المعايرة للميتاكلوبراميد هيدروكلورايد تمتد 0.0005 - 3 أو 0.0005 - 4 مللي مول. لتر-1 بمعامل ارتباط =0.9947 و 0.9845 على التوالي .حدود الكشف 3.543 نانوغرام /نموذج من التخفيف التدريجي لأقل تركيز في منحني المعايرة مع انحراف قيايس نسبي مئوي اقل من 0.3% لتركيز1,3 مللي مول .لتر -1 (n=8) من الميتاكلوبراميد هيدروكلورايد . طبقت الطريقة بنجاح لتعيين الميتاكلوبراميدهيدروكلورايد في ثلاثة مستحضرات صيدلانية . اجريت المقارنة بين الطريقة المستحدثة للتحليل والطريقة التقليدية لقياس التعكرية باستخدام الاضافات القياسية بوساطة اختبار t المزدوج ولوحظ انه لايوجد فرق جوهري بين الطريقتين عند مستوى قناعة 95 %.


Article
New mode for the on –line determination of metoclopramide hydrochloride in pure and pharmaceutical preparations via the use of homemade Ayah 6SX1-T-2D Solar cell CFI Analyser
نمط جديد للتقدير الاني للميتاكلوبراميد هايدروكلورايد في المستحضرات الصيدلانية والنقية من خلال استخدام محلل مصنع محليا للحقن الجرياني المستمرAyah 6SX1-T-2D Solar cell

Authors: Nagam S. Turkey Al-Awadie نغم شاكر تركي العوادي --- Kefah H. Ismael Al-saadi كفاح حسن اسماعيل الساعدي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 2C Pages: 1533-1552
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A newly developed analytical method characterized by its speed and sensitivity for the determination of metoclopramide hydrochloride (MCP-HCl) in pure and pharmaceutical preparations via absorbance measurement by Ayah 6SX1-T-2D Solar cell-CFI Analyser. The method is based on the oxidation of the drug with Ce(IV)sulfate in acidic medium to form a red color species which determined using homemade Ayah 6SX1-T-2D Solar cell . Chemical and physical parameters were studied and optimized. The calibration graph was linear in the range of 0.05- 16 mMol.L-1with correlation coefficient r = 0.9855. The limit of detection(S/N = 3) 0.332 µg/sample from the step wise dilution for the minimum concentration in the linear dynamic ranged of the calibration graph. The RSD% at 2 and 6mMol.L-1 metoclopramide hydrochloride is less than 0.6% (six replicate). The method was successfully applied for the determination of metoclopramide hydrochloride in three pharmaceutical drugs. A comparison was made between the newly developed method analysis with the classical method (UV-Vis spectrophotometry at λ max 474 nm) using the standard addition method via the use of t-test. It was noticed that there was a significant difference between two methods at 95 % confidence level.

طورت طريقة جديدة تميزت بالسرعة والحساسية لتقدير الميتاكلوبراميد هايدروكلورايد في المستحضرات الصيدلانية والنقية .استندت الطريقة على اكسدة الدواء بوساطة كبريتات السيريوم (IV ) في الوسط الحامضي لتكوين اصناف ملونة حمراء والتي قدرت باستخدام محلل الحقن الجرياني المستمرAyah 6SXI-T-2D Solar cell . تم دراسة كافة المتغيرات الكيميائية والفيزيائية . مدى الخطية لمنحني المعايرة للميتاكلوبراميد هايدروكلورايد 0.05 – 16 مللي مول لتر-1 بمعامل ارتباط (r) 0.9855 . حد الكشف=0.332 مكغم / انموذج من التخفيف التدريجي لأقل تركيز في منحني المعايرة . الانحراف القياسي النسبي المئوي لتركيز 2و6 مللي مول .لتر-1 اقل من 0.6 % (بتكرارية لست مرات). طبقت الطريقة بنجاح لتقدير الميتاكلوبراميد هايدروكلورايد في ثلاث عقاقير دوائية . اجريت المقارنة بين الطريقة المستحدثة والطريقة التقليدية (مطيافية UV- Vis) باستخدام الاضافات القياسية بوساطة اختبار t المزدوج ولوحظ انه هنالك فرق جوهري بين الطريقتين عند مستوى قناعة 95%


Article
Determination of oxonium ion using laser diode fluorimeter : (Blue purple(405 nm)-Green (532nm) using photodiode at 900 as a detector and I- -IO3- -H3O+ system for quenching of fluorescence
تقدير ايون الاوكسونيوم باستخدام محلل الحقن الجرياني فلوروميتر بثنائيات وصلة ليزرية :(ازرق-بنفسجي405نانومتر)-الاخضر( 532نانومتر) باستخدام ثنائي وصلة فوتوني بزاوية 900I- - IO3- -H3O+ كمتحسس لنظام اخماد الفلورسين

Authors: Nagam S. Turkey Al-Awadie نغم شاكر تركي العوادي --- Marwa A. Kadhim Al-banaa مروة عبدالرضا كاظم البناء
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 3B Pages: 2126-2148
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A newly developed sensitive, fast and accurate analytical method characterized by a sensitive, fast and accuracy for the determination of oxonium ion by laser diode fluorimeter-flow injection analysis. The method is based on the libration of free iodine causing to quench the fluorescence light (continuous fluorescence from fluorescien molecule (free acid)) when irradiated by laser source at 405nm. Chemical and physical parameters were studied and optimized. The optimum parameters were 1.3mL/min using fluorescien (free acid) as a carrier stream, 35µL sample volume at valve no.1 and 39µL at valve no.2 and opened valves sequentially. Data treatment shows that linear range 0.002-0.1mMol.L-1,0.01-0.2mMol.L-1,0.002-0.5mMol.L-1,0.002-0.7mMol.L-1 for HCl, H2SO4,HClO4 and tartaric acid respectively, with correlation coefficient r= 0.9562, 0.9976. 0.9755 and 0.9579. The limit of detection (S/N=3) 1.28ng/sample, 17.16ng/sample, 3.52ng/sample and 5.25ng/sample for HCl, H2SO4,HClO4 and tartaric acid respectively from the stepwise dilution for minimum concentration of lowest concentration in linear dynamic range of the calibration gragh. RSD% for the repeatability (n=8) was ˂1% for the determination of HCl, H2SO4,HClO4 and tartaric acid with concentration 0.01mMol.L-1 . The comparison was made between the newly developed method analysis with the classical method (pH-meter) using the standard addition method via the use of paired t-test was studied at two different paths .First path a comparison between two methods of analysis and second path between the two different acids. It was noticed that there was no significant difference between different acids and different methods at 95% confidence interval level.

طورت طريقة جديدة تميزت بالحساسية والسرعة والدقة لتقدير ايون الاوكسونيوم بواسطة استخدام محلل الحقن الجرياني- فلوروميتير بثنائيات وصلة ليزري.استندت الطريقة على تحرير اليود مسببا أخماد ضوء الفلورة (الفلورة المستمرة من جزيئة الفلورسين الحامضية عند التشعيع بلمصدر الليزري بطول موجي 405نانومتر). تم دراسة المتغيرات الكيميائية والفيزيائية .حيث تم أختيار سرعة جريان مثلى1.3ملليتر/دقيقة باستخدام محلول الفلورسين كتيار ناقل وحجم انموذج 35 مايكروليتر لصمام الحقن الاول و39مايكروليتر لصمام الحقن الثاني.أظهرت نتائج معالجة البيانات ان مدى الخطية لحامض الهيدروكلوريك,الكبريتيك ,البريكلوريك والترتاريك هي 0.002-0.1 مللي مول لتر-1,0.01-0.2 مللي مول لتر-1, 0.002-0.5مللي مول لتر-1 و0.002-0.7 مللي مول لتر-1 على التوالي بمعامل ارتباط (r) = 0.9562, 0.9976, 0.9755 و 0.9579 على التوالي. حد الكشف 1.28نغم/ انموذج, 17.16 نغم/ انموذج, 3.52نغم/ انموذج و5.25نغم/ انموذج من التخفيف التدريجي لاقل تركيز في منحني المعايرة. الانحراف القياسي النسبي لتركيز 0.01 مللي مول لتر-1 اقل من 1% بتكرارية لثمان مرات . اجريت المقارنة بين الطريقة المستحدثة والطريقة التقليدية ((pH-meter باستخدام الاضافات القياسية بوساطة اجراء اختبار t المزدوج بمسارين المسار الاول على اساس الاختلاف بين نوع الطريقة المستخدمة في التحليل والمسار الثاني استنادا على اختلاف مصدر الحامض ولوحظ من النتائج انه لايوجد فرق جوهري بين الطريقتين وبين مصدر الحامض المستخدم عند مستوى قناعة 95%.


Article
Novel Study of Cyproheptadine Hydrochloride Precipitate Formed by Potassium hexacyanoferrate and Sodium nitroprusside using Atomic Force Microscopy
دراسة نبيلة لراسب السايبروهبتادين هايدروكلورايد المتكون بوساطة سداسي سيانيد الحديد(III) البوتاسيوم و نايترو بروسيد الصوديوم باستخدام مجهر القوة الذرية

Loading...
Loading...
Abstract

Atomic Force Microscope is an efficient tool to study the topography of precipitate. A study using Continuous Flow Injection via the use of Ayah 6SX1-T-2D Solar cell CFI Analyser . It was found that Cyproheptadine –HCl form precipitates of different quality using a precipitating agent's potassium hexacyanoferrate (III) and sodium nitroprusside. The formed precipitates are collected as they are formed in the usual sequence of forming the precipitate via the continuous flow .The precipitates are collected and dried under normal atmospheric pressure. The precipitates are subjected to atomic force microscope scanning to study the variation and differences of these precipitates relating them to the kind of response to both precipitates give as. The incident light (i.e. super snow white LED) was scanned and it reveals that is , it compose of three components blue ,green and red color . The obtained spectrum were measured as a percentage area ( percentage effect ) also different models were study for the incident light irradiation of the measuring cell followed by the study of the effect on the detector area and responses .Various details and theoretical representation were adopted and were taken in to account ,the nodules (grains) on the surface were assumed to be sphere . The probability of radiation of the nodules of the surface of precipitate as the blue color and green color with the red color were 56.73% of green color , 42.12% of blue color and 1.15% of red color effect on the surface of precipitate .Granulation cumulating distribution data for both precipitates were measured also grains (nodules ) diameter were taken to concentration .

مجهر القوة الذرية هو اداة فعالة لدراسة تضاريس الراسب . اجريت الدراسة باستخدام تقنية الحقن الجرياني المستمر من خلال استخدام محلل الحقن الجرياني Ayah 6SX1-T-2D Solar cell CFI .لوحظ ان السايبروهبتادين هايدروكلورايد يكون رواسب بنوعية مختلفة باسخدام عوامل مرسبة , سداسي سيانيد الحديد (III) البوتاسيوم وصوديوم نايتروبروسيد .تم جمع الرواسب المتكونة من خلال الحقن الجرياني المستمر, و بدورها جففت تحت الضغط الجوي الاعتيادي .تم عرض الرواسب الى مجهر القوة الذرية لاجراء المسح لدراسة التباين والاختلاف للرواسب وربطها بنوع الاستجابة المستحصل عليها لكلا الراسبين . تم اجراء مسح للضوء الساقط ( ثنائي وصلة باعث للضوء الابيض الثلجي ) ولوحظ انه مكون من ثلاث مكونات الازرق , الاخضر واللون الاحمر وتم قياس الطيف المستحصل علية كنسبة مئوية للمساحة (النسبة المئوية المؤثرة) .كما درست نماذج مختلفة للضوء الساقط الذي يشعع خلية القياس تليها دراسة تاثيرة على مساحة المتحسس والاستجابات. مختلف التفاصيل والتمثيل النظري اعتمد واخذ بنظر الاعتبار , العقيدات (الحبيبات ) على السطح افترضت انها كرة . الاحتمالية لتشعيع العقيدات على سطح الراسب للضوء الاخضر , الازرق والاحمر كانت 73 .56% , .1242 % و 1.15 % على التوالي تؤثر على سطح الراسب . تم قياس بيانات التوزيع التراكمي لكلا الراسبين وكذلك قطر العقيدات اخذت بالحساب .


Article
Batch and Flow Injection Spectrophotometric Methods for the Determination of Clonazepam in Pharmaceutical Preparations via Oxidative Coupling with Pyrocatechol
استخدام الطرق الطيفية(الدفعة والحقن الجرياني) لتقدير دواء كلونازيبام في المستحضرات الصيدلانية من خلال تفاعل الازدواج التاكسدي مع البايروكاتيكول

Authors: Mouayed Q. Al-Abachi مؤيد قاسم العبايجي --- Maysaa Abdulwaha Hammoudi ميساء عبد الوهاب حمودي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 2A Pages: 898-908
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A simple, fast, and sensitive batch and flow injection spectrophotometric methods have been developed for the determination of clonazepam(CZP) in pure form and in pharmaceutical preparations. The proposed methods are based on the oxidative coupling reaction of the reduced clonazepam using Zn powders and conc. HCl with payrocatechol and in the presence of ferric sulphate. The resulting reddish colored product had a maximum absorbance at 515 nm. The optimum reaction conditions and other analytical parameters have been evaluated . The linear ranges for the batch and FI methods determination of CZP were 0.5-32, 50-400 μg mL-1 and the detection limits were 0.193, 22.60 μg mL-1 for both methods respectively. Statistical analysis of the results and comparison with results by the British Pharmacopoeia method are also reported.

تم تطوير طرق طيفية بسيطة وسريعة وحساسة تعتمد على طريقة الدفعة والحقن الجرياني لتقدير دواء كلونازيبام في شكله النقي و في المستحضرات الصيدلانية. تعتمد الطريقتين على تفاعل الازدواج التأكسدي للدواء المختزل بالزنك و بوجود حامض الهيدروكلوريك مع كبريتات الحديديك المائية وبايروكاتيكول حيث يتكون ناتج احمر ذائب في الماء يمتلك أقصى امتصاص عند طول موجي 515 نانومترًا. تم تثبيت المتغيرات الكيميائية والفيزيائية للحصول على أفضل حساسية و تطابقيه للنتائج. تم الحصول على منحنيات معايرة خطية من 0.5-32و50- 400مايكرو غرام مل- 1 مع قيم حد كشف 0.193 و 22.6 مايكرو غرام مل⁻¹ لكل من طريقة الدفعة والحقن الجرياني على التوالي. طبقت الطريقتين بنجاح في تقدير الدواء في المستحضرات الصيدلانية و كانت النتائج المستحصلة متوافقة مع النتائج المستحصلة من الطريقة القياسية المعتمدة من قبل دستور الأدوية البريطاني.


Article
Batch and Flow Injection Spectrophotometric Determination of Doxycycline Hyclate in Pharmaceutical Preparations

Authors: Mouayed Q. Al-Abachi --- Zaid A. Al-Nedawi
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2015 Volume: 18 Issue: 3 Pages: 24-32
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

New, simple and sensitive batch and flow injection spectrophotometric methods for the determination of doxycycline hyclate (DCH) in pharmaceutical preparations were developed. These methods were based on diazotization-coupling reaction between diazotized o-nitroanline (DONA) and DCH in sodium carbonate medium to form yellow-orange colored azo dye product has a maximum absorbance at 448 nm. Calibration graphs of absorbance versus concentration show that Beerʼs law were obeyed over the concentration ranges 0.4-52, 5-200 µg mL-1 of DCH, with limit of detection of 0.284, 1.117 µg mL-1 of DCH for batch and flow injection analysis (FIA) procedure respectively, and sample throughput was 171 h-1 for FIA method. All chemical and physical conditions affected on the developed colored product were carefully studied and the proposed methods were successfully applied for the determination of doxycycline in its pharmaceutical preparations.

يتضمن البحث تطوير طرائق طيفية جديدة وحساسة للتقدير المايكروغرامي للدوكسي سايكلين هيكلات في المستحضرات الصيدلانية باستخدام طريقتي الدفعة والحقن الجرياني. تعتمد هذه الطرائق على تفاعل الازوتة-ازدواج بين الاوثونايتروانيلين المؤزوت والدوكسي سايكلين في وسط قاعدي ليتكون لون اصفر-برتقالي من صبغة الاوزو الذائبة في الماء التي اعطت اعلى امتصاص عند 448 نانومتر. تشير منحنيات الامتصاص مقابل التركيز بان قانون بير ينطبق ضمن المدى 0.4-52 و 5-200 مايكروغرام مل-1 من الدوكسي سايكلين هيكلات وبحدود كشف 0.284 و 1.117 مايكروغرام مل-1 لكل من طريقتي الدفعة والحقن الجرياني على التوالي. وبمعدل نمذجة لطريقة الحقن الجرياني 171 نموذج في الساعة، بعد دراسة كافة المتغيرات الكيميائية والفيزيائية بدقة واختيار الظروف المثلى طبقت الطريقتين بنجاح في تقدير الدوكسي سايكلين في المستحضرات الصيدلانية.

Listing 1 - 10 of 16 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (16)


Language

English (15)


Year
From To Submit

2015 (16)