research centers


Search results: Found 8

Listing 1 - 8 of 8
Sort by

Article
Finite Element Analysis of Fins with Convection and Radiation Heat Transfer
تحليل انتقال الحرارة من الزعانف بالحمل والإشعاع باستخدام طريقة العناصر المحددة

Author: Mohammed HamzaAbdulsada محمد حمزة عبد السادة
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2015 Volume: 8 Issue: 2 Pages: 242-258
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

One dimensional analysis of heat transfer from fin is simple when only heat transfer by convectionfrom fin surface. However, in some cases heat transfers by combined phenomena (convection andradiation), this makes the governing differential equation of heat transfer non-linear and the analyticalsolution becomes hard to solve. This paper uses an approximate method to solve the problem withhigh-quality results based on finite element technique. The method can be used for different types offins and for different shapes. The results show suitable agreement between semi-exact solution andnumerical solution

التحليل ببعد واحد لانتقال الحرارة للزعنفة بسيط عندما تنتقل الحرارة من الزعنفة بواسطة الحمل فقط ولكن عندما تنتقلالحرارة من الزعنفة بواسطة التأثير المشترك للحمل والإشعاع، المعادلة التفاضلية لانتقال الحرارة سوف تصبح غير خطيةوسوف يكون الحل التحليلي لها صعب.هذه الورقة استعملت طريقة تقريبية لحل هذه المشكلة مع ظهور نتائج جيدة. والتيهي تعتمد أساسا على تقنية العناصر المحددة. أن الطريقة المستخدمة يمكن أن تطبق على أنواع مختلفة وأشكال مختلفة منالزعانف. النتائج تشير الى توقف مناسيب بين الحل التحليلي والحل العددي


Article
EXPERIMENTAL AND NUMERICAL STUDY OF ENHANCEMENT HEAT TRANSFER COEFFICIENT IN SPIRAL FLUTED TUBE HEAT EXCHANGER WITH NANOFLUID
دراسة عملية و عددية لتحسين أنتقال الحرارة في انبوب لولبي مخدد بوجود المائع النانوي

Authors: Muna S. Kassim --- Fouad A. Salah --- Ahmed O.Samarmad
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2015 Volume: 19 Issue: 6 Pages: 165-183
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Experimental and numerical investigation has been performed in this work to study enhancement of heat transfer coefficient in spiral fluted tube heat exchanger with Nanofluid. The shell side was made from galvanized tube of (65 mm) outer diameter. The tube was made from copper material of (1000 mm) length having (16 mm) equivalent inner diameter and (17 mm) outer diameter, it was inserted inside the shell. Steam was used, as a heating source where constant wall temperature condition (110˚C) was achieved, and TiO2 /water nanofluid with various volume concentrations (0.08%, 0.1%, 0.2%, and 0.3%) by volume at Reynolds numbers (7000 to 15000) has been employed, as working fluid flows through the inner tube. Fiber glass has been utilized to cover the outer surface of the shell for reducing heat losses. The performance of spiral fluted tube heat exchanger with and without nanofluid was investigated experimentally. Experimental results reveal that the use of spiral fluted tube without nanofluid leads to increase (28-33) % in heat transfer coefficient compared with smooth tube, and the maximum increase in heat transfer coefficient occurs when using spiral fluted tube with nanofluid at 0.3% volume concentration was about (25-28) % higher than the pure water in spiral fluted tube. Empirical correlations for water, nanofluid were represented by Nusselt number. Numerical simulation has been carried out on present heat exchanger to analyze both flow field and heat transfer using ANSYS 14, FLUENT package. The comparison between experimental and numerical results showed good agreement.

في هذا العمل تم انجاز دراسة عملية وعددية لتحسين انتقال الحرارة باستخدام انبوب لولبي مخدد بوجود المائع النانوي. القشرة مصنوعةمن الحديد المغلون 65 مليمتر قطر خارجي. الانبوب مصنوع من النحاس بطول 1000 مليمتر ، 16 مليمتر قطر داخلي مكافئ و 17 مليمتر قطرخارجي تم تثبيته داخل القشرة. استخدم البخار كمصدر حراري على السطح الخارجي للانبوب حيث تم الحصول على درجة حرارة ثابتة لسطحالانبوب ) °C110 (، المائع النانوي من نوع اوكسيد التيتانيوم /ماء مقطر بتراكيز حجمية مختلفة ) 0.08 ، 0.1 ، 0.2 ، 0.3 (% و يمر داخلالانبوب عند عدد رينولدز يتراوح بين ) 7000 - 15000 (. تم عزل القشرة من الخارج بعازل حراري لتقليل الحرارة المفقودة.تمت دراسة اداءالمبادل الحراري ذو الانبوب اللولبي المخدد بدون ومع المائع النانوي. بينت النتائج العملية زيادة في معامل انتقال الحرارة بمقدار) 28 - 33 (% عنداستخدام الانبوب اللولبي المخدد بدون المائع النانوي مقارنه بالانبوب الاملس،تم الحصول على اقصى زيادة في معامل انتقال الحرارة عند استخدامالانبوب اللولبي المخدد بوجود المائع النانوي وبتركيز 0.3 % بمقدار ) 25 - 28 (%مقارنه باستخدام الماء في الانبوب اللولبي المخدد.تم ايجادعلاقات تجريبية للماء و المائع النانوي بدلالة رقم نيسلت.تم انجاز محاكاة عددية للمبادل الحراري لتحليل جريان المائع و انتقال الحرارة باستخدامالبرنامج المختص .ANSYS 14, FLUENT package هناك تطابق مقبول عند المقارنة بين النتائج العملية والعددية


Article
Shell and Double Concentric Tube Heat Exchanger Calculations and Analysis
الحسابات والتحاليل للمبادل الحراري ذو القشرة والانابيب المتداخلة المتمركزة

Authors: Basma Abbas Abdulmajeed بسمة عباس عبد المجيد --- Fadhil Abed Allawi فاضل عبد علاوي
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2015 Volume: 21 Issue: 1 Pages: 62-82
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This study concerns a new type of heat exchangers, which is that of shell-and-double concentric tube heat exchangers. The case studies include both design calculations and performance calculations. The new heat exchanger design was conducted according to Kern method. The volumetric flow rates were 3.6 m3/h and 7.63 m3/h for the hot oil and water respectively. The experimental parameters studied were: temperature, flow rate of hot oil, flow rate of cold water and pressure drop.A comparison was made for the theoretical and experimental results and it was found that the percentage error for the hot oil outlet temperature was (- 1.6%). The percentage errors for the pressure drop in the shell and in the concentric tubes were (17.2%) and (- 39%) respectively. For cold water outlet temperature, the percentage error was (- 3.3%), while it was (18%) considering the pressure drop in the annulus formed. The percentage error for the total power consumed was (-10.8%). A theoretical comparison was made between the new design and the conventional heat exchanger from the point of view of, length, mass, pressure drop and total power consumed.

ان هذه الدراسة تعنى بنوعية جديدة من المبادلات الحرارية , هو المبادل الحراري ذو القشرة والانابيب المتداخلة المتمركزة.هذا البحث يتضمن الحسابات التصميمية وحسابات كفاءة المبادل. ان المبادل الحراري الجديد صمم على طريقة((kern method حيث تم استخدام دهن ساخن ذو تدفق حجمي 3.6m3/h وماء بارد ذو تدفق حجمي .7.63m3/hالمتغيرات التي تم قياسها من التجارب العملية هي درجة الحرارة و معدل الجريان للدهن الساخن ومعدل الجريان للماء. تم اجراء مقارنة بين النتائج العملية والنظرية للمبادل الجديد حيث وجد ان نسبة الخطأ بالنسبة لدرجة حرارة الدهن الساخن الخارجة من المبادل هي (-1.6%), ونسبة الخطأ بالنسبة لهبوط الضغط في ال(shell)هي (17.2%), وكانت نسبة الخطأ بالنسبة لهبوط الضغط في الانابيب المتداخلة هي ( (-39%.اما بالنسبة للماء البارد فقد كانت نسبة الخطأ هي ((-3.3% بالنسبة لدرجة حرارة الماء الخارج من المبادل ونسبة الخطأ بالنسبة لهبوط ضغط الماء المار في التشكيل الجديد الحاصل من الانابيب المتداخلة هي 18%)), اما بالنسبة لمقدارالطاقة الكلية المصروفة فقد كانت نسبة الخطأ (-10.8%). هذا البحث تضمن مقارنة نظرية بين تصميم المبادل الحراري الجديد والمبادل التقليدي من حيث الطول, الوزن ,هبوط الضغط ومقدار الطاقة المصروفة.


Article
PREDICTION OF SCALE REMOVAL WEIGHT DEPOSITED ON SURFACE OF HEAT EXCHANGER USING ARTIFICIAL NEURAL NETWORK
التنبؤ بإزالة وزن القشرة المترسبة لأنابيب مبادل حراري باستخدام الشبكات العصبية الاصطناعية

Author: Suheila Abd Al-Reda Akkar
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2015 Volume: 8 Issue: 4 Pages: 855-868
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

Scale is a term generally used in industry refers to any deposit on equipment surface. Usually the deposition of scale is undesirable because it is uncontrolled and a build-up of scale on metal surfaces may act as insulation causing decreased efficiency. So removal of scale has gained special attention in the last few years due to its significance, when predicting removal scale weight. However, the complexity and variability makes it hard to model its effects. This study evaluates the usefulness of Artificial Neural Networks (ANN) to predict the scale removal weight as a function of several of their properties which have been related in previous studies i.e. time, concentration of organic acid salts, Temperature, density, viscosity. Results showed that neural networks are a powerful tool and that the validity of the results is closely linked to the amount of data available and the experience and knowledge that accompany the analysis. The structure of ANN models is [5-18-1] the best because reach MSE 0.001 with AARE%, S.D%, and R (0.12, 0.46, 0.9) respectively. The training of network use MATLAB program.

إزالة الترسبات من السطوح الداخلية لأنابيب المبادلات الحرارية والمراجل والمبخرات وغيرها فقد حاز على اهتمام الكثيرين قي السنوات الأخيرة فكان لابد من التنبؤ في إزالة وزن القشرة المترسبة لأنابيب مبادل حراري ولوجود التعقيدات والمتغيرات في التصميم تم استخدام الشبكات العصبية الاصطناعية للتنبؤ بإزالة وزن القشرة المترسبة كدالة لعدد من الخواص اعتمدت على جمع نتائج لأنابيب مبادل حراري من مصفى الدورة وهي الزمن، التركيز أملاح الحوامض العضوية, درجة الحرارة, الكثافة واللزوجة.قد برهنت النتائج قوة الشبكة العصبية في إظهار النتائج بشكل مقارب للنتائج العملية.


Article
Augmentation of Heat Transfer Through Heat Exchanger With and Without Fins by Using Nano fluids
تحسين انتقال الحرارةِ خلال مبادل حراري مع وبدون زعانف باستعمال المواد النانوية

Author: Khalid Faisal Sultan خالد فيصل سلطان
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2015 Volume: 19 Issue: 4 Pages: 15-36
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

This study was carried out to study the effect of silver and oxide zirconium – oil nanofluids on enhancement heat transfer in a heat exchanger with and without fins by changing flow direction. This study was done by changing the parallel flow configuration into counter flow configuration under laminar flow regime. The properties of nanofluids (density, viscosity, thermal conductivity and specific heat) are practically measured. The two types of nanofluids at 1%, 2%, 3%, 4% and 5% particle volume concentration were prepared by two step method. The nanofluid was applied in a heat exchanger with and without fins to enhance heat transfer. The measured results show that silver with oil nanofluid gives maximum heat transfer enhancement compared with oxide zirconium nanofluid used. The presence of Ag and ZrO2 nanoparticles attributes to the generation of strong nanoconvection current and better mixing. The effect of different parameters such as flow Reynolds number, nanofluid temperature, concentration and type of nanoparticle on heat transfer coefficient and pressure drop of the flow are studied. The obtained results show an increase in heat transfer coefficient to (Ag + oil) and (ZrO2 + oil) for heat exchanger with fins 38.5 % ,25.33% while without fins 22.41% and 16.25% respectively at concentration of 5%vol compared with base fluid (oil). The heat transfer coefficient and pressure drop is increased by using nanofluids (Ag + oil, ZrO2 + oil) instead of the base fluid (oil). The shear stress of nanofluids increases with an increase in concentration of nanoparticles for both parallel flow and counter flow. No much impact of changing flow direction on overall heat transfer coefficient .The precent work decided that the nanofluids behaviors are close to the typical Newtonian fluids through the relationship between viscosity and shear rate for ranging from (1% vol – 5% vol ). This article indicated that the thermal performance from nanofluids that contain metal nanoparticles show more enhancements compared to oxide nanofluids due to higher thermal conductivity for the silver. Moreover to performance index are used to present the corresponding flow and heat transfer technique.

تقدّمُ هذه المقالةِ دراسةَ تجريبيةَ عن تأثير الموائع الفائقة الدقة مثل (الفضة مع الزيت, وأوكسيد الزركونيوم مع الزيت) على تحسينِ نقلِ الحرارةِ والجريان في مبادل حراري بدون ومع وجود زعانف وبتغير اتجاه الجريان. هذه الدراسة تمت بتغير اتجاه الجريان من جريان متوازي الى جريان متعاكس تحت شرط جريان طباقي . كما وتم قياس الخواص الحرارية للموائع النانوية ( الكثافة ,الموصلية الحرارية ,الحرارة النوعية, اللزوجة) عملياً. أثنان مِنْ أنواعِ الجزئيات النانوية استعملت في هذه الدراسة وهي الفضة (Ag (40nm)) وأكسيد الزركونيوم(ZrO2 (60nm)) بالإضافة إلى مائع الأساس (زيت) وبتراكيز تَتراوحُ مِنْ (1 – 5 % ) وقد تم تحضير هذه الموائع بطريقة الخطوتين. المائع النانوي يمكن ان يطبق في مبادل حراري مع وجود او عدم وجود الزعانف في تحسين انتقال الحرارة. النتائج بينت ان استخدام المائع النانوي من الفضة والزيت يعطي اقصى تحسين من اوكسيد الزركونيوم والزيت. ان وجود هذه الجزئيات النانوية مثل الفضة واوكسيد الزركونيوم يؤدي الى توليد تيارات حمل نانوية وبالتالي يحصل خلط جيد. أنّ تأثيرَ العوامل المختلفةِ مثل عدد رينولدز للجريان , درجة حرارة المائع النانوية ونوع وتركيز الجزئيات النانوية على معاملِ اتنقالِ الحرارةِ وهبوطِ ضغطِ الجريان قد تم دراسته. كما بينت الدراسة نسب التحسين في معامل نقل الحرارة باستخدام الفضة والزيت ,واوكسيد الزركونيوم والزيت في مبادل حراري مع وجود او عدم وجود الزعانف,38.5 % , 22.41%, 25.33% 16.25% على الترتيب وعند تركيز 5% vol بمقارنة مع الزيت كما بينت الدراسة ان معامل انتقال الحرارة وانحدار الضغط يزداد عند استخدام المائع النانوي بدل من الزيت. كما اوضحت الدراسة ان اجهاد القص للمائع النانوي يزداد مع زيادة التركيز للجريان المتوازي والمتعاكس وقد بينت النتائج انه لا تأثير كبير على تغير اتجاه الجريان على معامل انتقال الحرارة الكلي . هذه المقالة اقرت ان الموائع النانوية هي موائع نيوتينية من خلال علاقة اللزوجة واجهاد القص والى مدى (1 – 5 % ) بالاضافة الى انها بينت ان الاداء الحراري للموائع النانوية التي تحتوي جزئيات نانوية معدنية اكثر تحسين بالمقارنة مع جزئيات نانوية تحتوي أوكسيد الزركونيوم بسب الموصلية الحرارية العالية للفضة. علاوة على ذلك تم استخدام عامل الاداء لتقيم التدفق وانتقال الحرارة.


Article
Heat Transfer Characteristics of a Fluid Flow in Multi Tube Heat Exchanger Fitted with Perforated Fins
خصائص انتقال الحرارة لمائع يجري خلال مبادل حراري متعدد الانابيب مجهز بزعانف مثقبة

Authors: Ayad Dawood Suliman اياد داؤد سليمان --- Dhia Al-Deen Hussain Alwan ضياء الدين حسين علوان --- Nabil Jamil Yasin نبيل جميل ياسين
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2015 Volume: 21 Issue: 11 Pages: 40-59
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The heat transfer and flow resistance characteristics for air flow cross over circular finned tube heat exchanger has been studied numerically and experimentally. The purpose of the study was to improve the heat transfer characteristics of an annular finned-tube heat exchanger for better performance. The study has concentrated on the effect of the number of perforations and perforations shapes on the heat transfer and pressure drop across a staggered finned tube heat exchanger. The Numerical part of present study has been performed using ANSYS Fluent 14.5 using SST Turbulent model, while the experimental study consist from a test rig with different models of heat exchangers and all required measurement devices were building up to cover the experimental work for the range of Reynolds number (7500-17500). The experimental results show that average Nusselt number of the six circular perforations fins model is about 11.08 % higher than that for solid fin model and with triangular perforations model is about 10.12 % higher than that for the solid fin. Triangular perforation finned heat exchanger model gives a best result than the other models due to excessive increment in the )Nu( in comparison with other models take in consideration pressure drop. The results were validated with previous work and the comparison between the experimental and numerical shows a good agreement with a maximum deviation ±10% between them.

تمت دراسة خصائص انتقال الحرارة ومقاومة الجريان للهواء المار عبر مبادل حراري مزعنف نظرياً وتجريبياً. الغرض من هذه الدراسة هو محاولة تحسين خصائص انتقال الحرارة لمنظومة انابيب حلقية الزعانف للحصول على اداء افضل. ركزت الدراسة على معرفة تأثير عدد الثقوب واشكالها على عملية انتقال الحرارة وانخفاض الضغط خلال مبادل حراري من النوع المتخالف الترتيب. في الدراسة النظرية تم انشاء الشبكة باستخدام برنامجANSYS Fluent.14 مع موديل الجريان الاضطرابي SSTبينما تضمن العملي ضمن ال بناء جهازتجريبي يحتوي كافة نماذج المبادل الحراري المصنعة وجميع اجهزة القياس المطلوبة لغرض الدراسة التجريبية ضمن حدود عدد رينولد (7500-17500). اظهرت النتائج التجريبية ان عدد نسلت للزعانف الحاوية على ستة ثقوب دائرية اعلى بحدود 11.08% من الزعانف الغير مثقبة, في حين ان عدد نسلت كان اعلى بمقدار 10.12% للزعانف الحاوية على أربع ثقوب مثلثية عن الزعانف الغير مثقبة. كذلك اظهرت الدراسة ان نتائج الزعانف ذوات الثقوب المثلثة هي الافضل بالمقارنة مع باقي النماذج نظراً للزيادة الملحوضة في عدد نسلت بالاخذ بنظر الاعتبار الزيادة في انخفاض الضغط. تمت مقارنة النتائج النظرية مع بحوث سابقة وكذلك اجريت مقارنة بين النتائج النظرية والتجريبية وقد اظهرت تقارباً مقبولاً بينهما بانحراف لا يتعدى ±10%.


Article
Effect of variable fluid properties on the hydrodynamic and thermal characteristics of parallel flow microchannel heat exchanger
تأثير الخواص المتغيرة للمائع على الخصائص الهيدروديناميكيه والحراريه للمبادل الحراري المتوازي المايكروي

Author: Dr. Mushtaq Ismael Hasan م.د. مشتاق إسماعيل حسن
Journal: Univesity of Thi-Qar Journal مجلة جامعة ذي قار العلمية ISSN: 66291818 Year: 2015 Volume: 10 Issue: 4 Pages: 1-14
Publisher: Thi-Qar University جامعة ذي قار

Loading...
Loading...
Abstract

In this paper the parallel flow microchannel heat exchanger is numerically investigate and the effect of treating the properties of fluids as variables with temperature compared with constant fluid properties assumption on its performance is studied. A numerical simulation is made to solve 3D Navier stock equations in two fluids with temperature dependent properties and 3D energy equation in two fluids and solid walls taking into account the effect of entrance region and axial conduction in the walls.The properties entered to the main program by relations as a function of temperature using subroutines written to calculate the properties at the end of each iteration. The results obtained show that, treating the properties as a temperature dependent gives higher overall performance since it leads to obtain lower pressure drop and higher effectiveness compared with constant properties assumption.

تم في هذا البحث دراسة تأثير خواص الموائع كقيم متغيرة على أداء المبادل الحراري المتوازي المايكروي مقارنة مع فرضية الخواص الثابتة. تم حل معادلات نافير ستوك ثلاثية الأبعاد عدديا في كلا المائعين مع خواص متغيره كذلك تم حل معادلة الطاقة ثلاثية الأبعاد عدديا في كلا المائعين والجدران الفاصلة بينهما والأخذ بنظر الاعتبار تاثير كل من منطقة الدخول والتوصيل الحراري المحوري في الجدران. تم إدخال خواص الموائع الى البرنامج الرئيسي على شكل علاقات بدلالة درجه الحرارة خلال برامج فرعية كتبت لحساب الخواص عند نهاية كل تكرار للبرنامج. النتائج التي تم التوصل اليها تشير الى ان فرضية معاملة الخواص كقيم متغيرة مع درجة الحرارة تعطي اكبر اداء للمبادل حيث انها تؤدي الى الحصول على هبوط ضغط اقل وفعالية أعلى للمبادل مقارنة مع فرضية الخواص الثابتة.


Article
Entransy dissipation of Shell and Double Concentric Tube Heat Exchanger Calculations and Analysis
حسابات وتحليل منظومة المبادل الحراري ذو القشرة والانابيب المتداخلة المتمركزة باستخدام تبديد الانترانسي

Author: Basma Abbas Abdulmajeed بسمة عباس عبد المجيد
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2015 Volume: 21 Issue: 6 Pages: 1-14
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Shell-and-double concentric tube heat exchanger is one of the new designs that enhance the heat transfer process. Entransy dissipation is a recent development that incorporates thermodynamics in the design and optimization of heat exchangers. In this paper the concept of entransy dissipation is related to the shell-and-double concentric tube heat exchanger for the first time, where the experiments were conducted using hot oil with temperature of 80, 100 and 120°C, flow rate of cold water was 0.667, 1, and 1.334 kg/m3 respectively and the temperature of inlet cold water was 20°C. The entransy dissipation rate due to heat transfer and to fluid friction or pressure drop was studied.

ان المبادل الحراري ذو القشرة والانابيب المتمركزة المتداخلة هو احد التصاميم الجديدة لتفعيل عملية انتقال الحرارة.ان عملية تبديد الانترانسي والتي توظف الثرموداينمك في عملية تصميم المبادلات الحرارية المثلى هو تطبيق حديث. في هذا البحث سوف يتم تطبيق مبادئ الانترانسي على المبادل الحراري الحراري ذو القشرة والانابيب المتمركزة المتداخلة ولاول مرة, حيث تمت دراسة التجارب عند درجة حرارة الزيت الساخن مساوية لـ 80, 100 و120°م و معدل جريان الماء البارد كان 0,667 و1 و1,334 كغم/م3 و درجة حرارة الماء البارد الداخل مساوية لـ 20°م. تمت دراسة معدل تبديد الانترانسي نتيجة انتقال الحرارة والاحتكاك او انخفاض الضغط.

Listing 1 - 8 of 8
Sort by
Narrow your search

Resource type

article (8)


Language

English (8)


Year
From To Submit

2015 (8)