research centers


Search results: Found 48

Listing 1 - 10 of 48 << page
of 5
>>
Sort by

Article
Simulation the Radiation Zone of Al-Mussaib Power Plant by Using Monte Carlo Method

Authors: Tahseen Ali Al-Hattab --- Ali Abd Al-Muhsen Al-Assady --- Wisam Ahmed Abd Al-Wahid
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2015 Volume: 16 Issue: 4 Pages: 67-78
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The temperature distributions are to be evaluated for the furnace of Al-Mussaib power plant. Monte Carlo simulation procedure is used to evaluate the radiation heat transfer inside the furnace, where the radiative transfer is the most important process occurring there. Weighted sum of gray-gases model is used to evaluate the radiative properties of the non gray gas in the enclosure. The energy balance equations are applied for each gas, and surface zones, and by solving these equations, both the temperature, and the heat flux are found. Good degree of accuracy has been obtained, when comparing the results obtained by the simulation with the data of the designing company, and the data obtained by the zonal method. In the above work, a code of Monte Carlo method is built, and used to overcome the mathematical analysis.


Article
Ambient Temperature Affect the Pore size of PVA Nanofibers Tissues
تأثير درجة حرارة المحيط على الحجم المسامي لانسجة الياف بولي فينال الكحول النانويه

Authors: Akram R. Jabur --- Laith K. Abbas --- Safa M. Muhi Aldain
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 6 Part (B) Scientific Pages: 1040-1047
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Electrospinning has recently emerged as a leading technique for generating biomimetic scaffolds made of synthetic and natural polymers for tissue engineering applications. PVA was dissolved in distilled water at concentration (10% wt). PVA 10% DW solution was prepared as biopolymeric materials for fabricating tissue engineered scaffolds by electrospinning, varying ambient temperature (25, 30, 35, 40, 45 and 50) ͦ C andinvestigated the ambient temperature effect on tissue nanofibers pore size. Scanning electron microscopy was utilized to profile the topography of individual electrospun fibers. Statistical measurements for each SEM images lead to measure the mean poresize of tissue obtained. Our results indicate that the average poresize of PVA fibertisues could be scaled down to mean values (132-300)nm smooth nanofibers without any beads, poresize decreased as ambient temperature increase to certain temperature at (40 °C) and retrain increasing at (45 and 50) °C temperature.

برز البرم الالكتروني حديثا" كتقنية رائده لتخليق سقالات محاكاة بايولوجيا مصنعه من بوليمرات صناعيه او طبيعيه لاستخدامات الهندسة النسيجيه . أذيب بولي فينال الكحول في ماء مقطر بتركيز 10% وزنيا" . حضر بولي فينال الكحول 10% من الماء المقطر كماده سائل بوليمر احيائي لتصنيع سقالات هنسة نسيجيه بالبرم الالكتروني , وبتغيير درجات حرارة المحيط (45,40,35,30,25 و( 50 ͦم° ودراسة تأثير تغيير درجة حرارة المحيط على حجم المسامي للانسجه الليفيه النانويه.أستخدم فحص المجهر الالكتروني الماسح لتحديد شكل وطوبوغرافية الالياف المبرمه الكترونيا .واجريت حسابات احصائيه من كل صور من صور المجهر الالكتروني الماسح المأخوذه للالياف لتحديد معدل حجم المسامات للنسيج المحضر والمفحوص . النتائج التي تم الحصول عليها تدل على أن معدل حجم المسامات للالياف أنسجه بولي فينال الكحول يمكن أن تتدرج الى قيمه ممتده بين (132-300) نانومتر لالياف ملساء دون حصول اي عقد , والحجم المسامي يتناقص بزيادة درجة حرارة المحيطه الى درجه حراره معينه هي 40 م° والتي بعدها يعود للتزايد عند درجات حراره (50, 45) م°.


Article
Indoor Investigation for Improving the Hybrid Photovoltaic /Thermal System Performance Using Nanofluid (AL2O3-Water)
دراسة مختبرية لتحسين اداء المنظومة الحرارية الكهروضوئية الهجينة باستخدام مائع اوكسيد الالمنيوم النانوي

Authors: Hashim A. Hussien --- Ali H. Noman --- Abdulmunem Raad Abdulmunem
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 4 Part (A) Engineering Pages: 889-901
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Hybrid Photovoltaic/Thermal system (PV/T) wasdesigned and implemented to investigate the improving of the electrical and thermal efficiency by using nanofluids. The electrical efficiency reduced due to the significant reduction in the maximum power of the photovoltaic panel under rising temperature, for this reason, the payback period of the PV system is extended and the lifespan of the PV module may also be shortened. In order to resolve this problem, cooling technique can be utilized effectively dissipate the heat from the PV module. An experimental rig is designed which is consisting of a heat exchanger and working fluid circulating pipes are placed at PV rear surface. Forced cooling using (AL2O3-Water) nanofluid with different concentration ratios tests is utilized to reduce the operating temperature of PV.The results indicated that using base fluid, the temperature of the PV module was (79.1oC) and a conversion efficiency of about (8 %.).While using nanofluid at different concentration ratios (0.1- 0.5 step 0.1) % at constant mass flow rate (0.2 l/s), the temperature is more dropped significantly to (42.2oC) at concentration ratio (0.3%) and led to increase in the efficiency of solar panel to (12.1%), but when increasing of concentration ratios more than (0.3%) that led to increase PV temperature to (52.2oC) and led to a decrease of PV efficiency to (11.3%). The heat which was extracted from the PV module by the cooling nanofluid can contribute to the overall energy output of the system.

المنظومة الهجينة (PV/T) صممت ونفذت للتحقق عمليا من امكانية تحسين كفاءتها الكهربائية والحرارية باستخدام تقنية التبريد بالمواد النانوية . ان الكفاءة الكهربائية تنخفضنتيجة ارتفاع درجة الحرارة في اللوح الشمسي ولهذا السبب فان فترة الاسترداد للنظام وعمر اللوح الشمسي قد تقل . تقنية تبريد اللوح الشمسي بالماءاستخدمت لحل هذه المشكلة لتبديد الحرارة من اللوح الشمسي . تقنية التبريد عمليا تكونت من مبادل حراري وانابيب ماء وضعت على السطح الخلفي للوح الشمسي وبتبريد قسري باستخدام اوكسيد الالمنيوم النانوي وبتراكيز مختلفة تم تحضيرها واستخدمت لتقليل درجة الحرارة .النتائج بينت بدون استخدام اوكسيد الالمنيوم النانوي مع الماء فان درجة حرارة اللوح الشمسي كانت (79.1oC) والكفاءة الكهربائية لاتتعدىتقريبا 8% بينما عند استخدام اوكسيد الالمنيوم النانوي وبتراكيز مختلفة (0.1- 0.5 step0.1)% وبثبات جريان المائع عند (0.2L/s)فان درجة الحرارة انخفضت الى درجة (42.2oC) عند نسبة تركيز (0.3%) مما ادى الى زيادة بالكفاءة الكهربائية للمنظومة بقيمة اكثر من (12.1%)ولكن عند زيادة نسبة التركيز اكثر من (0.3%) فان درجة الحرارة قد ازدادت الى (52.2oC) وقلت الكفاءة الى (11.3%). الحرارة التي بددت من اللوح الشمسي باستخدام تقنية التبريد باستخدام النانو بامكانها ان تزيد الطاقة الكلية الخارجة من المنظومة الهجينة .


Article
Diagnostic Study of Copper Plasma in Air by Laser Induced Breakdown Spectroscopy (LIBS)
دراسة تشخيصة لبلازما النحاس في الهواء عن طريق طيف الانهيارالمستحث بالليزر

Authors: Mohammed S.Mahde --- Alaa H. Ali --- Mohannad H. Hussein
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 5 Part (A) Engineering Pages: 1002-1008
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this work, we study a diagnostic of a copper-plasma in air using a fundamental wavelength of a Nd: YAG laser system. The optical emission spectra of copper-plasma that have been detected using a spectrum analyzer (Thorlabs GmbH) have been used to extract the excited plasma temperature via the Saha-Boltzmann method, and measure the electron number density by McWhirter criterion. Measured values of Ne and (Te) is in the range of (14890.827 K°) and (Ne) is (2.7*1015 cm-3) at the fundamental wavelength.

في هذا العمل تم تشخيص بلازما النحاس في الهواء باستخدام ليزر الندميوم- ياك النبضي بالطول الموجي الاساسي 1064 nm, وبطاقة .75 mjأطياف الانبعاث الضوئي من بلازما النحاس تم الكشف عنها باستخدام المحلل الطيفي, اطياف الانبعاث استخدمت لاستخراج درجة حرارة البلازما وحساب كثافة الاكترون, حيث كانت درجة حرارة بلازما النحاس هي( K° 14890.827) , وكثــــافة الاكترون (2.7*1015 cm-3)


Article
Determination Some Creep Factors For Lead Under Tension
تحديد بعض معاملات الزحف للرصاص تحت اجھاد الشد

Author: Tariq Mohammed Ali Al Nuaimi طارق محمد علي النعيمي
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 8 Part (B) Scientific Pages: 106-118
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

There are a lot of engineering structures working at elevated temperatures for long periods, as in chemical plants, generation, transfer and energy application or devices uses of energy, such as turbines and reactors. When those parts work at high temperature, it was found that their materials which exposed to loads will undergo to plastic deformation and deforms slowly like a crawl turtle, for this reason they named this slow deformation as a Creep. Care has been given in this research has to study the issue of creep under the influence of various loads under certain temperature, and the implementation of a creep test machine by a tension samples made from lead .This research includes a study of creep parameters under the influence of temperatures. Creep properties were investigated under constant stress and fixed temperature in terms of the relation between a strain for period of times by the specimen used in this study which was lead and the applied load was tension.

تعمل الكثير من الأجزاء الهندسية في درجات حرارة مرتفعة ولفترات طويلة كما هو الحال في المصانع الكيميائية وايضا في مجال توليد وتحويل وتطبيقات الطاقة والوسائل المستخدمة فيها كما في التوربينات والمفاعلات ، لقد وجد عند عمل هذه الاجزاء بدرجات حرارة مرتفعة فان مادتها التي تتعرض لاحمال سوف تتعرض الى تشوه لدن ببطيء شديد أشبه بزحف السلحفاة ، لذلك يسمى هذا التشكيل البطيء بالزحف (Creep) . لقد إهتم هذا البحث بدراسة موضوع الزحف تحت تأثير أحمال مختلفة وبدرجة حرارة ثابتة وتنفيذ جهاز اختبار الزحف بالشد لعينات من مادة الرصاص. يتضمن هذا البحث دراسة معالم الزحف تحت تأثير درجات الحرارة . ان خواص الزحف التي تم التقصي عنها تحت اجهاد ثابت ودرجة حرارة معينة وذلك عن طريق العلاقة بين الانفعال لفترات زمنية للعينة المستخدمة في هذه الدراسة التي تكون من الرصاص النقي تحت تاثير حمل شد .


Article
An Evaluation of Some Mechanical Properties of Autopolymerizing Acrylic Resin with the Modified One after Changing the Curing Environment: (In vitro Study)

Author: Intisar J. Ismail
Journal: Journal of baghdad college of dentistry مجلة كلية طب الاسنان بغداد ISSN: 16800087 Year: 2015 Volume: 27 Issue: 4 Pages: 62-71
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Background: Studying and investigating the transverse strength(Ts), impact strength(Is), hardness (Hr) and surfaceroughness(Ra) of conventional and modified autopolymerizing acrylic resin with different weight percentages ofbiopolymer kraftlignin, after curing in different water temperatures; 40°C and 80°C.Material and Methods: Standard acrylic specimens were fabricated according to ADA specification No.12 fortransverse strength, ISO 179 was used for impact testing, Shore D for hardness and profilometerfor surface roughness.The material lignin first dispersed in the monomer, then the powder PMMA is immediately added. Lignin added indifferent weight percentages. Then cured using pressure pot (Ivomet) in two temperatures;40°C and 80°C under 2bar pressure, for 30 minutes.Atotal of 144samples were prepared for this study. Ts, Is, Ra, and Hr were tested, by usingInstron universal testing machine, charpy impact tester, shore D tester, and profilometer respectively.Results: The transverse strength increased in both the conventional and modified onewhen compared with thatcured in air. The addition of 0.5wt% lignin gave the higher effect (78.0017MPa) with highly significant difference foundbetween groups at 40°C polymerizing temperature. While the impact strength in both temperatures in the modifiedresin revealed increased results than conventional one, 1.25wt% of kraft lignin gave the highest value (12.7355KJ/m2)with highly significant differences found between groups at 80°C polymerizing temperature. Hardness and surfaceroughness showed also highly significant differences found between groups at 40°C polymerizing temperature, allthe groups had increased Hr. than the control one (78.95), while the Ra. decreased for 1.0% ,1.25,1.50 and 1.75 wt%lignin content to (0.26,0.10,0.063, 0.12μm) respectively in 40°C polymerizing temperature, the lowest value present in1.75 wt% lignin (0.05 μm) at 80°Cpolymerizing temperature.Conclusions: It seems that increasing the polymerizing temperature to 40°C had a positive effect on the mechanicalproperties of autopolymerizing acrylic resin and the one enforced by kraft lignin biopolymer in low percentages.Increasing the polymerizing temperature to 80°C will doesn’t have much positive effect but it doesn’t deteriorate themechanical properties. However, when submitted to increasing the temperature to 80°C, specimens showed asignificantincrease in impact strength


Article
Energy Saving of Heat Gain by Using Buried Pipe Inside a Roof
ترشيد في كسب الطاقة الحرارية بأستخدام الأنابيب المدفونة في السقف

Author: Ahmed A. M. Saleh أحمد عبد محمد صالح
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2015 Volume: 11 Issue: 1 Pages: 32-39
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This work deals with a numerical investigation to evaluate the utilization of a water pipe buried inside a roof to reduce the heat gain and minimize the transmission of heat energy inside the conditioning space in summer season. The numerical results of this paper showed that the reduction in heat gain and energy saving could be occurred with specific values of parameters, like the number of pipes per square meter, the ratio of pipe diameter to the roof thickness, and the pipe inlet water temperature. Comparing with a normal roof (without pipes), the results indicated a significant reduction in energy heat gain which is about 37.8% when the number of pipes per meter of roof length is 3.0 , the ratio of pipe diameter to the wall thickness (D/W) is 0.20, and the water inlet temperature is 30°C, while the minimum ratio of reduction 24% is achieved when the number of pipes per meter, the ratio of pipe diameter to the wall thickness, and the water inlet temperature are 27, 30 and 33 °C, respectively. The results also showed that there is a very small effect of pipe centre position inside the wall on the final heat transmission.

في هذا العمل أجريت دراسة عددية لمعرفة تأثير أنابيب الماء المدفونة في السقوف على تقليل الكسب الحراري ومنع انتقال الحرارة الى داخل الفضاءات المكيفة. وأضهرت نتائج البحث أن هنالك أمكانية لتقليل الكسب الحراري عند قيم محددة من العوامل المؤثرة مثل عدد الأنابيب للمتر الواحد من عرض السقف ونسبة قطر الأنبوب الى سمك السقف (D/W) و درجة حرارة الماء الداخل الى الأنبوب. حيث بينت النتائج ان هنالك تخفيض بنسبة 40 % مقارنة مع السقف الخالي من الأنابيب عندما يكون عدد الأنابيب للمتر الواحد هو 3 ونسبة قطر الأنبوب الى سمكه بحدود 0.5 ودرجة حرارة الماء الداخل الى الأنبوب هي °C30 ، بينما بلغت أقل نسبة من التخفيض وهي 14 % عند عدد الأنابيب يساوي 1 لكل متر من عرض السقف ونسبة قطر الأنبوب الى سمك السقف هي 0.5 ايضاً ولكن درجة حرارة الماء الداخل الى الأنبيب هي °C33 وكلاهما عند عدد رنولدز للماء المنساب خلال الأنبوب هو 3000 . كما وأضهرت النتائج بأن هنالك تأثير بسيط جداًعلى كمية الحرارة المنتقلة خلال السقف عند تغيير موقع مركزالأنبوب داخل السقف.


Article
Numerical Investigation of Power Plant Operates with Super critical Pressure Boiler
دراسة عددية لمحطة قدرة تشتغل بواسطة مرجل بخاري يعمل بضغط اعلى من الضغط الحرج

Author: Kadhim Fadhil Nasir كاظم فاضل ناصر
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2015 Volume: 18 Issue: 1 Pages: 76-83
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

Numerical investigations were made of heat transfer to supercritical water flowing in a boiler vertical tube. A comprehensive set of data was obtained for pressures from 22.09 MPa to 25 MPa, mass velocity 250-400 kg/m2s, the results are bulk temperatures from 345°C to 445°C, heat fluxes from 150 to 800 kW/m2, tube diameter was 48 mm. The steady thermal model for cross section of water wall tube was established. Heat flux and temperature of working fluid are determined by using Fortran computer program at each section of the tube length. The heat transfer coefficients show behavior depending upon the heat flux. the power of plant, boiler efficiency, and plant efficiency was determined at different mass velocities, we found that the boiler and plant efficiencies increasing with the increasing of power of plant. The comparison between this investigation results and the results of other sources, we found good agreement between literatures references and numerical results of this study.

تم اجراء دراسة نظرية لانتقال الحرارة الى الانابيب العمودية لمرجل بخاري يعمل على ضغط اعلى من الضغط الحرج للماء. تم الحصول على مجموعة شاملة من النتائج باستخدام ضغوط تراوحت من (22.09) الى (25) ميكا باسكال وباستخدام سرع كتلية تراوحت من (250) الى (400) كغم /م2 ثا. فكانت النتائج لدرجات الحرارة العظمى للجريان تراوحت من 345 الى 445 درجة سليلوزية والفيض الحراري من( 150 الى 800) كيلو واط/م2 , تم استخدام انبوب قطره( 48) ملمتر, تم بناء نمودج حراري مستقر مع الزمن بمساحة مقطع لجدار الانبوب الذي يجري الماء في داخله. تم ايجاد معدل الفيض الحراري و درجة الحرارة لمائع التشغيل بواسطة استخدام برنامج الفورتران الحسابي في كل مقطع على طول الانبوب , وجد ان تصرف معامل انتقال الحرارة يعتمد على الفيض الحراري. كما تم ايجاد الكفاءة الحرارية لكل من المرجل البخاري والمحطة عند سرع كتلية لجريان المائع مختلفة فوجد ان كفاءة كل من المرجل البخاري وكفاءة المحطة تزداد بزيادة القدرة المتولده من المحطة . تم مقارنة النتائج التي تم الحصول عليها في هذه الدراسة مع النتائج الموجوده في المصادر فوجد تطابق واضح بين النتائج.

Keywords

supercritical --- pressure --- temperature --- boiler --- plant --- heat --- flux --- power.


Article
Temperature Effect on Photovoltaic Modules Power Drop
تأثير درجة الحرارة على انخفاض قدرة وحدات الخلايا الشمسية

Author: Qais Mohammed Aish قيس محمد عايش
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2015 Volume: 11 Issue: 2 Pages: 62-73
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In order to determine what type of photovoltaic solar module could best be used in a thermoelectric photovoltaic power generation. Changing in powers due to higher temperatures (25oC, 35oC, and 45oC) have been done for three types of solar modules: monocrystalline , polycrystalline, and copper indium gallium (di) selenide (CIGS). The Prova 200 solar panel analyzer is used for the professional testing of three solar modules at different ambient temperatures; 25oC, 35oC, and 45oC and solar radiation range 100-1000 W/m2. Copper indium gallium (di) selenide module has the lowest power drop (with the average percentage power drop 0.38%/oC) while monocrystalline module has the highest power drop (with the average percentage power drop 0.54%/oC), while polycrystalline module has a percentage power drop of 0.49%/oC.

من اجل تحديد أي نوع من وحدات الخلايا الشمسية يكون استخدامها أفضل مع زيادة درجة الحرارة . تغير القدرة نتيجية زيادة درجات الحرارة (25oC, 35oC, and 45oC) تم ايجاده لثلاثة أنواع من وحدات الخلايا الشمسية وهي احادية التبلور، ثنائية التبلور، و نحاس- أنديوم- جليوم والسليناد الثنائي. لقد استعمل جهاز بروفا 200 لتحليل الخلايا الشمسية لفحص وحدات الخلايا الشمسية الثلاث وفي درجات حرارة مختلفة : 25 ، 35، و 45 درجة مئوية وضمن مدى اشعاع شمسي 100 الى 1000 واط لكل متر مربع. وحدة الخلية نوع نحاس- أنديوم- جليوم والسليناد الثنائي هي الأقل أنخفاض في قدرة 0.38%/oC بينما وحدة الخلية نوع احادية التبلور هي الاعلى 0.54%/oC. بينما وحدة الخلية متعددة التبلور كانت نسبة انخفاض الفولتية هي 0.49%/oC.


Article
Structural Performance of Reinforced Concrete Bubble Slabs after Exposing to Fire Flame
ألاداء ألانشائي للبلاطات الخرسانية المسلحة والمجوفة بعد التعرض الى لهب النار

Author: Thaar Saud Salman Al-Gasham ثائر سعود سلمان الغشام
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2015 Volume: 19 Issue: 4 Pages: 1-14
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

This paper presents the results of experimental program investigating the effect of fire flame (high temperature) on the structural performance of bubble slabs. The program consisted casting and testing nine specimens. The dimensions of the specimens were 270 X 500mm in plane and with two different thicknesses; 90 and 140mm. All specimens were cast with normal concrete of approximately 25 MPa compressive strength. Seven specimens were burnt using a diesel furnace and two specimens were kept without burning as controls. The test parameters were; the fire flame temperature (200, 500, and 800 oC), the cooling method is processed gradually by left the slabs in the air or suddenly by using water, the exposure time (1, 1.5, and 2 hours), and thickness of slabs (90 and 140mm). After cooling, the specimens were simply supported in one direction and tested under a uniform load applied gradually till failure. The test results showed that, the residual strength of specimens decreased from 71.8% to 21.6% and their central deflection increased with increasing the fire flame temperature from 200 to 800 oC and exposure time from 1 to 2 hours. For suddenly cooling specimen the residual flexural strength and central deflection were less than those of same specimen when cooled gradually. Finally, increasing the thickness of bubble slabs by 56% improved distinctly both the residual strength about 45% and stiffness of specimens. Key words: Bubble slabs, Temperature, Burning, Exposure time, Fire flame.

يقدم هذا البحث نتائج البرنامج العملي لتحري تأثير الحرق بدرجات عاليه بلهب النار على الاداء الانشائي للبلاطات الخرسانيه المسلحه المجوفه. تضمن البرنامج انشاء وفحص تسعه نماذج. أبعاد النماذج كانت 500 ملم طول و 270 ملم عرض و السمك اما 90 ملم او 140 ملم . جميع النماذج انشأت من خرسانه اعتياديه ذات مقاومه انضغاط 25 ميكا باسكال. سبع نماذج تم حرقها بأستخدام فرن نفطي واثنان تم حفظهما بدون حرق للمقارنة. العوامل التي تم دراسة تأثيها في هذا البحث كانت : درجة الحرق ( 200 و 500 و800 مْ) , طريقة التبريد ( تبريد تدريجي بترك النماذج في الهواء او تبريد فجائي باستخدام الماء), فترة التعرض ( 1و1.5 و 2 ساعة) واخيراّ سمك البلاطه (90 ملم او 140 ملم). بعد انتهاء عمليه تبريد النماذج , أسندت النماذج بشكل بسيط من أتجاه واحد وفحصت تحت تأثير حمل منتشر تم تسليط ذلك الحمل بصوره تدريجية الى درجة الفشل. بينت نتائج البحث ان المقاومه المتبقيه للنماذج انخفضت من 71,8% الى 21.6% والهطول في منتصف النماذج أزداد مع ازدياد كلا من درجه الحرق من 200 الى 800 م ْ وفترة التعرض من 1 الى 2 ساعه . المقاومة المتبقية والهطول للنموذج المبرد بشكل فجائي كانت اقل من النموذج المبرد بشكل تدريجي واخيراً أن الزياده في سمك البلاطه بمقدار 56% ادى الى تحسين ملحوظ في كلاً من المقاومة المتبقيه ( بمقدار 45 %)وصلابة العينات.

Listing 1 - 10 of 48 << page
of 5
>>
Sort by
Narrow your search

Resource type

article (48)


Language

English (35)

Arabic (6)

Arabic and English (6)


Year
From To Submit

2015 (48)