research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
STRENGTHENING OF MODIFIED REACTIVE POWDER CONCRETE COLUMNS WITH CFRP
تقوية اعمدة خرسانة المساحيق الفعالة المعدلة باستخدام البوليمر المسلح بالياف الكاربون

Authors: Mutaz Kadhim Madhlom --- Mohammed Hashim Mohammed
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2016 Volume: 20 Issue: 1 Pages: 16-37
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

An experimental investigation was conducted to investigate the behavior of modified reactiveconcrete (MRPC) columns before and after strengthening with carbon fiber reinforced polymer (CFRP) sheetsjacketing under eccentric axial load. Twelve columns were tested up to failure, strengthened and retested toexamine strengthening efficiency and to evaluate the effects of variation of the concrete type (normal or MRPC),presence of steel fibers and main steel reinforcement ratio. Experimental results showed that CFRP jacketingincreases the ultimate failure load of strengthened columns up to 185%, highly stiffens them (reduces lateraldisplacements) and allow more ductile failure than the original columns. Also, inclusion of steel fibers in MRPCcolumns increases failure loads up to 83%, prevents spalling of the concrete cover and increase the ductility.

يتناول هذا البحث دراسة عملية على سلوك اعمدة مصنوعة من خرسانة المساحيق الفعالة المعدلة (MRPC) قبل و بعد التقوية باستخدام الياف الكاربون (CFRP) والمعرضة الى احمال محورية لامركزية. تم فحص و تقوية و اعادة فحص اثنى عشر عمودا لاختبار كفاءة التقوية و معرفة تاثيرات تغيير نوع الخرسانة (عادية او MRPC) و وجود الياف الحديد ونسبة حديد التسليح الرئيسي. اظهرت النتائج العملية ان التقوية باستخدام CFRP زادت احمال الفشل القصوى للاعمدة المقواة حتى 185 % كما زادت كثيرا من صلادتها (قللت الازاحات الجانبية) و سمحت بفشل اكثر مطيلية من الاعمدة الاصلية. كما ان استخدام الياف الحديد في اعمدة MRPC زاد احمال الفشل حتى 83% و منع تشظي خرسانة الغطاء و زاد المطيلية.


Article
STRUCTURAL BEHAVIOR OF MODIFIED REACTIVE POWDER AND REACTIVE POWDER CONCRETE WALL PANELS SUBJECTED TO HIGH TEMPERATURE

Author: Zinah Waleed Abbas زينة وليد عباس
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2016 Volume: 9 Issue: 4 Pages: 36-47
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

This research presents an experimental work to investigate the structural behavior of concrete wall panels subjected to high temperature (3500c) and distributed load. Eight specimens of wall panels were tested in this study and divided equally in to four groups, each group consists of two wall panels first one with slenderness ratio (H/t=20) and the other one with slenderness ratio (H/t=14). The first group with normal strength concrete, the second with high strength concrete, the third with modified reactive powder concrete (MRPC) and the fourth with reactive powder concrete (RPC). The results shows that for wall panels with slenderness ratio H/t=20 the lateral deflection decrease by about 19% as concrete strength (fc') increase from 30.2Mpa to 69.5Mpa and about 58% as concrete strength (fc') increase to 128Mpa at failure load, while for H/t=14 the lateral deflection decrease by about 49% as concrete strength (fc') increase from 30.2Mpa to 69.5Mpa and about 28% as concrete strength (fc') increase to 128Mpa at failure load. For Wall panels with high strength concrete, MRPC, and RPC there is no big difference between lateral deflection at the linear part for panel with H/t=14and panel with H/t=20. This difference increases at the nonlinear part of the curves. The failure load increases by about 62% as the concrete strength (fc') increases from 30.2Mpa to 69.5Mpa and increases to 50% as the concrete strength (fc') increases from 69.5Mpa to 128Mpa for panels with H/t=14. The failure load increases by about 89% as concrete strength (fc') increases from 30.2Mpa to 69.5Mpa and the failure load increases by 56% as the concrete strength (fc') increases from 69.5Mpa to 128Mpa for panels with H/t=20. For all tested panels the failure mode was buckling failure and the cracks for wall panels with RPC and MRPC are close to center of the panel.

يتضمن هذا البحث دراسة عملية لتصرف الجدار اللوحي الكونكريتي المعرض لدرجة حرارة عالية (3500C) و حمل منتشر . أظهرت النتائج أنه للنماذج ذات نسبة النحافة H/t=20)) فأن الأنحراف الجانبي يقل بنسبة 19% بزيادة مقاومة الانضغاط من 30.2Mpa الى 69.5Mpa و بنسبة 58% بزيادة مقاومة الانضغاط الى 128Mpa عند حمل الفشل. بينما للنماذج ذات نسبة النحافة H/t=14)) فأن الأنحراف الجانبي يقل بنسبة 49% بزيادة مقاومة الانضغاط من 30.2Mpa الى 69.5Mpa و بنسبة 28% بزيادة مقاومة الانضغاط الى 128Mpa عند حمل الفشل. تم دراسة ثمانية نماذج من الجدار اللوحي الكونكريتي وقسمت هذه النماذج الى اربعة مجاميع متساوية كل مجموعة تحتوي على نموذجين الاول يكون ذا نسبة نحافة (H/t=20) والثاني ذا نسبة نحافة (H/t=14) . المجموعة الاولى تتضمن نماذج تكون فيها الخرسانة ذات مقاومة انضغاط اعتيادية و الثانية ذات مقاومة انضغاط عالية و المجموعة الثالثة الخرسانة المستعملة هي خرسانة المساحيق الفعالة المعدلة (MRPC) و المجموعة الرابعة الخرسانة المستعملة هي خرسانة المساحيق الفعالة (RPC). النماذج ذات مقاومة الانضغاط العالية (MRPC,RPC ) تظهر النتائج انه لا يوجد اختلاف كبير في الجزء الخطي من الانحراف الجانبي للوحي الكونكريت ذا نسبة نحافة (H/t=20 و H/t=14) , هذا الاختلاف في الانحراف الجانبي للوحين يزداد في الجزء اللاخطي. حمل الفشل يزداد بنسبة 62% بزيادة مقاومة الانضغاط للكونكريت من 30.2Mpa الى 69.5Mpa وتكون نسبة الزيادة في حمل الفشل بنسبة 50% بزيادة مقاومة الانضغاط من 69.5Mpa الى 128Mpa للجدار اللوحي ذا نسبة نحافة H/t=14 . كما ان حمل الفشل يزداد بنسبة 89% بزيادة مقاومة الانضغاط للكونكريت من 30.2Mpa الى 69.5Mpa وتكون نسبة الزيادة في حمل الفشل بنسبة 56% بزيادة مقاومة الانضغاط من 69.5Mpa الى 128Mpa للجدار اللوحي ذا نسبة نحافة H/t=20 . لجميع النماذج من الجدار اللوحي الكونكريتي يكون نوع الفشل هو فشل انبعاج وتكون الشقوق بالنسبة للالواح المصنوعة من (MRPC,RPC ) بالقرب من المنتصف.

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

English (2)


Year
From To Submit

2016 (2)