Shear Behavior of Self Compacting Reactive Powder Reinforced Concrete T- beams
سلوك القص للعتبات الخرسانية المسلحة ذات المقطع- T والمصنوعة من خرسانة المساحيق الفعالة ذاتية الرص

Authors: Ali H Aziz علي حميد عزيز --- Luma A. Zghair لمى عبد الغني صغير --- Awadh E. Ajeel عوض عجيل
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2016 Volume: 19 Issue: 1 Pages: 1-9
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

The present research can be divided into three categories following the respective three main objectives. The first objective is to develop a self-compacting reactive powder concrete (SCRPC). The second objective is to study the effect of steel fiber content on mechanical properties of (SCRPC). The third objective is to study the effect of steel fiber content on shear behavior of (SCRPC) RC T-beams. Therefore, five beam specimens were tested, one of which were made with (NSC) (reference beam), while, the others were constructed with (SCRPC) with different steel fiber volume fraction. Besides the beam specimens, a series of casting and testing were carried out to study the properties of (SCRPC) in fresh and hardened states. Experimental results show that the use of (SCRPC) improves the shear resistance and allowing higher forces to be carried through both, web and flange. When the steel volume fraction (Vf) changed from (0%) to (1.5%), the ultimate shear strength increased about (75%) to (91%), while, the cracking load increased about (50%) to (108%). This means the cracking and an ultimate load depends essentially on concrete strength and steel volume fraction.

أعدت هذه الدراسة لثلاثة أهداف، (أولا) تطوير نوع من الخرسانة تتوفر فيها مواصفات الخرسانة ذاتية الرص و خرسانة المساحيق الفعالة للحصول على خرسانة المساحيق الفعالة ذاتية الرص. (ثانيا) دراسة تأثير نسبة ألياف الحديد على الخواص الميكانيكية لخرسانة المساحيق الفعالة ذاتية الرص. (ثالثا) دراسة سلوك القص للعتبات المسلحة ذات المقطع-T والمصنوعة من خرسانة المساحيق الفعالة ذاتية الرص. تم إجراء سلسلة من الفحوصات المختبرية على خمسة عتبات خرسانية مسلحة ذات مقطع(T)، العتبة الأولى (العتبة المرجعية) تم صناعتها من الخرسانة الاعتيادية وبدون ألياف أما بقية العتبات فتم صناعتها باستخدام خرسانة المساحيق الفعالة ذاتية الرص مع نسب مختلفة من ألياف الحديد. لكافة العتبات المفحوصة، تم الإبقاء على أبعاد الوترة (Web)، أبعاد الشفة (Flange)، العمق الكلي، فضاء العتبة، حديد التسليح الطولي و العرضي بدون أي تغيير. بالإضافة إلى ذلك، تم إجراء سلسلة من الفحوصات على نماذج السيطرة (مكعبات و مواشير) لدراسة خواص الخرسانة الطرية و المتصلبة. اظهرت النتائج المختبرية نقصان في مقاومة القص بحدود (22%-32%) في العتبات التي تحتوي على فتحة واحدة في الشفة، ونقصان بحدو(17%-39%) في العتبات التي تحتوي على فتحتين في الشفة. بالنسبة للعتبات التي تحتوي على مفاصل انشائية، اظهرت النتائج المختبرية نقصان في مقاومة القص بحدود (23%) عند مقارنتها مع العتبة المرجعية.


Article
STRENGTHENING OF MODIFIED REACTIVE POWDER CONCRETE COLUMNS WITH CFRP
تقوية اعمدة خرسانة المساحيق الفعالة المعدلة باستخدام البوليمر المسلح بالياف الكاربون

Authors: Mutaz Kadhim Madhlom --- Mohammed Hashim Mohammed
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2016 Volume: 20 Issue: 1 Pages: 16-37
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

An experimental investigation was conducted to investigate the behavior of modified reactiveconcrete (MRPC) columns before and after strengthening with carbon fiber reinforced polymer (CFRP) sheetsjacketing under eccentric axial load. Twelve columns were tested up to failure, strengthened and retested toexamine strengthening efficiency and to evaluate the effects of variation of the concrete type (normal or MRPC),presence of steel fibers and main steel reinforcement ratio. Experimental results showed that CFRP jacketingincreases the ultimate failure load of strengthened columns up to 185%, highly stiffens them (reduces lateraldisplacements) and allow more ductile failure than the original columns. Also, inclusion of steel fibers in MRPCcolumns increases failure loads up to 83%, prevents spalling of the concrete cover and increase the ductility.

يتناول هذا البحث دراسة عملية على سلوك اعمدة مصنوعة من خرسانة المساحيق الفعالة المعدلة (MRPC) قبل و بعد التقوية باستخدام الياف الكاربون (CFRP) والمعرضة الى احمال محورية لامركزية. تم فحص و تقوية و اعادة فحص اثنى عشر عمودا لاختبار كفاءة التقوية و معرفة تاثيرات تغيير نوع الخرسانة (عادية او MRPC) و وجود الياف الحديد ونسبة حديد التسليح الرئيسي. اظهرت النتائج العملية ان التقوية باستخدام CFRP زادت احمال الفشل القصوى للاعمدة المقواة حتى 185 % كما زادت كثيرا من صلادتها (قللت الازاحات الجانبية) و سمحت بفشل اكثر مطيلية من الاعمدة الاصلية. كما ان استخدام الياف الحديد في اعمدة MRPC زاد احمال الفشل حتى 83% و منع تشظي خرسانة الغطاء و زاد المطيلية.


Article
Effect of Volume of STEEL Fibers on the Punching Shear Behavior of Hybrid Reinforced Concrete Flat SLAB
تأثير حجم الألياف على تصرف القص الثاقب للبلاطات المستوية المصنعة هجينيا

Authors: Layth Al-Jaberi --- Zinah Waleed Abbas --- Esraa Kamal Jaffar
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2016 Volume: 20 Issue: 2 Pages: 24-38
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The main object of this study is to figure out the effects of the volume of fibers (Vf) on the punching shear behavior of hybrid system of flat slab that made of Lightweight Concrete (LWC) and Reactive Powder Concrete (RPC). Five flat slabs, two of them made fully of Normal Strength Concrete (NSC) (named as S1) and LWC (named as S2), and the rest three made of LWC and RPC (named as S3, S4 and S5). The variable in S3, S4 and S5 is the values of Vf which are (0.5%, 1% and 2%) respectively. The hybrid flat slabs are designed that RPC to fill the critical zone of the punching shear area, and LWC to fill the remaining area. At 28 days age of concrete, the slabs are simply supported along the all edges and single point load applied at the center of slab until the failure is happened.The experimental work indicates that S1, S2 and S3 are failed with punching shear failure. While S4 and S5 are suddenly failed in the region occupied by LWC. The results show that S2 exhibits the weaker behavior, followed by S1. S3 has the best behavior of failure among all. The load deflection curves for all tested slabs behaves first as linear relation followed by nonlinear relation up to failure. The values of of (fcu), (Pc) and (Pu) for S1 are higher than those for S2 by about (69%, 29% and 42%) respectively. While the values of the same properties for S3 are higher than those for S2 by about (622%, 128% and 142%) respectively, and about (326%, 78% and 71%) respectively than those for S1

: ان الهدف الأساسي من هذه الدراسة هو لاكتشاف مدى تأثير حجم الالياف (Vf) على طبيعة فشل القص الثاقب للبلاطات المستوية المصنعة هجينيا من الخرسانة الخفيفة (LWC) الوزن وخرسانة المساحيق الفعالة (RPC). تم تصنيع خمس بلاطات ، اثنان منها مصنعة بالكامل من الخرسانة الاعتيادية المقاومة (NSC) (S1) والخرسانة الخفيفة الوزن (S2) ، والثلاثة المتبقية مصنعة هجينيا من الخرسانة خفيفة الوزن وخرسانة المساحيق الفعالة (S3 و S4 و S5). المتغير في (S3 و S4 و S5) هو قيمة نسبة الالياف (Vf) والتي كانت (0.5% و 1% و 2%) على التوالي. تم صب البلاطات المهجنة بحيث يغطي (RPC) المنطقة الحرجة لمنطقة القص الثاقب ، بينما يغطي (LWC) بقية البلاطة. عند (28) يوم من عمر الخرسانة تم تعريض البلاطات الى فحص الحمل المركز على العمود وبالاستناد البسيط من جميع الجهات. أشر الفحص حدوث فشل القص الثاقب لكل من (S1, S2 and S3) ، بينما اشر حدوث فشل فجائي في منطقة (LWC) في البلاطات (S4 and S5). أظهرت النتائج ان (S2) هي ذات الطبيعة الأضعف بين البلاطات ، تليها (S1). كان تصرف الفشل للبلاطة (S3) هو الأمثل والأفضل. أظهرت منحنيات التحميل – الانحراف لجميع البلاطات سلوكا خطيا مرنا عند البداية يليه سلوك لاخطي لدائني لحين حصول الفشل .


Article
Experimental study of Circular Short Columns made from Reactive Powder Concrete

Authors: Asmaa Ali Ahmad --- Faidhi Abdul-Rahman Alkhazraji --- Sarah Mohammed Omar
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2016 Volume: 34 Issue: 9 Part (A) Engineering Pages: 1860-1872
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

This research studies the behavior of reactive powder concrete (RPC) circular short columns with and without steel fibers of different types, as well as change of the reinforcement kinds of lateral (hoops and spiral) and the spacing between them. The experimental work consist study of fifteen short column specimens having an overall height of 1 m with circular cross-section of 150 mm diameter are loaded at ends with concentric loads. Six of the specimens are cast with the inclusion of steel fibers with aspect ratio of 75(group 1), and six of other specimens are cast with the inclusion of steel fibers with aspect ratio of 100 (group 2),and the other three specimens is without steel fibers, with hybrid steel fibers and high strength concrete. The concrete mix of fiber-reinforced samples contains 1% by volume of steel fibers of variable reinforcement longitudinal and lateral (hoops and spiral reinforcement). Experimental data for strength, failure mode, lateral, and the ductility were obtained for each test. The work concluded that the using of steel fibers in RPC was an effective way to prevent spalling of the concrete cover and increase the ductility and the using of high ratio of longitudinal reinforcement delays the pickling of the columns and increase strength. The ultimate load capacity of RPC columns of spiral lateral reinforcement is greater than the load of RPC columns of tied lateral reinforcement by about 1.25 to 1.35 times for the two groups.


Article
STRUCTURAL BEHAVIOR OF MODIFIED REACTIVE POWDER AND REACTIVE POWDER CONCRETE WALL PANELS SUBJECTED TO HIGH TEMPERATURE

Author: Zinah Waleed Abbas زينة وليد عباس
Journal: DIYALA JOURNAL OF ENGINEERING SCIENCES مجلة ديالى للعلوم الهندسية ISSN: 19998716/26166909 Year: 2016 Volume: 9 Issue: 4 Pages: 36-47
Publisher: Diyala University جامعة ديالى

Loading...
Loading...
Abstract

This research presents an experimental work to investigate the structural behavior of concrete wall panels subjected to high temperature (3500c) and distributed load. Eight specimens of wall panels were tested in this study and divided equally in to four groups, each group consists of two wall panels first one with slenderness ratio (H/t=20) and the other one with slenderness ratio (H/t=14). The first group with normal strength concrete, the second with high strength concrete, the third with modified reactive powder concrete (MRPC) and the fourth with reactive powder concrete (RPC). The results shows that for wall panels with slenderness ratio H/t=20 the lateral deflection decrease by about 19% as concrete strength (fc') increase from 30.2Mpa to 69.5Mpa and about 58% as concrete strength (fc') increase to 128Mpa at failure load, while for H/t=14 the lateral deflection decrease by about 49% as concrete strength (fc') increase from 30.2Mpa to 69.5Mpa and about 28% as concrete strength (fc') increase to 128Mpa at failure load. For Wall panels with high strength concrete, MRPC, and RPC there is no big difference between lateral deflection at the linear part for panel with H/t=14and panel with H/t=20. This difference increases at the nonlinear part of the curves. The failure load increases by about 62% as the concrete strength (fc') increases from 30.2Mpa to 69.5Mpa and increases to 50% as the concrete strength (fc') increases from 69.5Mpa to 128Mpa for panels with H/t=14. The failure load increases by about 89% as concrete strength (fc') increases from 30.2Mpa to 69.5Mpa and the failure load increases by 56% as the concrete strength (fc') increases from 69.5Mpa to 128Mpa for panels with H/t=20. For all tested panels the failure mode was buckling failure and the cracks for wall panels with RPC and MRPC are close to center of the panel.

يتضمن هذا البحث دراسة عملية لتصرف الجدار اللوحي الكونكريتي المعرض لدرجة حرارة عالية (3500C) و حمل منتشر . أظهرت النتائج أنه للنماذج ذات نسبة النحافة H/t=20)) فأن الأنحراف الجانبي يقل بنسبة 19% بزيادة مقاومة الانضغاط من 30.2Mpa الى 69.5Mpa و بنسبة 58% بزيادة مقاومة الانضغاط الى 128Mpa عند حمل الفشل. بينما للنماذج ذات نسبة النحافة H/t=14)) فأن الأنحراف الجانبي يقل بنسبة 49% بزيادة مقاومة الانضغاط من 30.2Mpa الى 69.5Mpa و بنسبة 28% بزيادة مقاومة الانضغاط الى 128Mpa عند حمل الفشل. تم دراسة ثمانية نماذج من الجدار اللوحي الكونكريتي وقسمت هذه النماذج الى اربعة مجاميع متساوية كل مجموعة تحتوي على نموذجين الاول يكون ذا نسبة نحافة (H/t=20) والثاني ذا نسبة نحافة (H/t=14) . المجموعة الاولى تتضمن نماذج تكون فيها الخرسانة ذات مقاومة انضغاط اعتيادية و الثانية ذات مقاومة انضغاط عالية و المجموعة الثالثة الخرسانة المستعملة هي خرسانة المساحيق الفعالة المعدلة (MRPC) و المجموعة الرابعة الخرسانة المستعملة هي خرسانة المساحيق الفعالة (RPC). النماذج ذات مقاومة الانضغاط العالية (MRPC,RPC ) تظهر النتائج انه لا يوجد اختلاف كبير في الجزء الخطي من الانحراف الجانبي للوحي الكونكريت ذا نسبة نحافة (H/t=20 و H/t=14) , هذا الاختلاف في الانحراف الجانبي للوحين يزداد في الجزء اللاخطي. حمل الفشل يزداد بنسبة 62% بزيادة مقاومة الانضغاط للكونكريت من 30.2Mpa الى 69.5Mpa وتكون نسبة الزيادة في حمل الفشل بنسبة 50% بزيادة مقاومة الانضغاط من 69.5Mpa الى 128Mpa للجدار اللوحي ذا نسبة نحافة H/t=14 . كما ان حمل الفشل يزداد بنسبة 89% بزيادة مقاومة الانضغاط للكونكريت من 30.2Mpa الى 69.5Mpa وتكون نسبة الزيادة في حمل الفشل بنسبة 56% بزيادة مقاومة الانضغاط من 69.5Mpa الى 128Mpa للجدار اللوحي ذا نسبة نحافة H/t=20 . لجميع النماذج من الجدار اللوحي الكونكريتي يكون نوع الفشل هو فشل انبعاج وتكون الشقوق بالنسبة للالواح المصنوعة من (MRPC,RPC ) بالقرب من المنتصف.


Article
BEHAVIOR OF COMPOSITE I-SECTION MODIFIED REACTIVE POWDER CONCRETE BEAMS WITH ULTIMATE TORQUE
سلوك العتبات الخرسانيه المركبة مع الحديد ذات المقطع(I) والمحتوية على خرسانه المساحيق الفعالة المطورة مع عزم اللي الاقصى.

Authors: Redhaab Hamed Saad --- Ali Sabah Ahmed
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2016 Volume: 20 Issue: 6 Pages: 55-67
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

This paper presents experimental work includes investigation of seven composite modified reactive powder concrete (MRPC) I- beams, 1300mm length, 100mm web width and 320mm height, with and without opening tested under pure torsion. The first beam was the control beam without steel plate and the second beam was solid with steel plate and the five of these beams were cast as composite beams and opening in web. The main variable was the location, shape and size of opening in web .The experimental results show that the web opening decreases the ultimate torque of composite beams in the range of 17.6% to 30.8% for the tested specimens.as well as the results show that the used steel plates increase the ultimate torque of composite beams by 7.7%.

هذا البحث يتضمن التحريات العملية لسبع عتبات خرسانيه مركبه من خرسانه المساحيق الفعالة المطورة ذات مقطع (I) بطول 1300mm وعرض الساق 100mm وارتفاع 320mmلمقاطع مختلفة (مع فتحات وصلده) فحصت تحت تأثير عزم اللي الصافي. العتبة الاولى كانت العتبة المرجعية بدون صفيحه حديديه والعتبة الثانية كانت صلده وتحتوي على صفيحه حديديه اما العتبات الخمسة الاخرى فقد كانت عتبات مركبه تحتوي على فتحات في الساق .المتغيرات الرئيسية في هذه الدراسة هي موقع وشكل وحجم الفتحات في الساق .اظهرت نتائج الفحص ان الفتحات في الساق تقلل من عزم الدوران الاقصى للمقاطع المركبة بحدود17.6% الى30.8% وكذلك اظهرت النتائج ان وجود الصفائح الحديدية تزيد من عزم الدوران الاقصى للمقاطع المركبة بنسبه7.7% .


Article
Some Properties of Carbon Fiber Reinforced Magnetic Reactive Powder Concrete Containing Nano Silica
بعض خواص خرسانة المساحيق الفعالة الممغنطة المسلحة بألياف الكاربون الحاوية على النانو سيليكا

Authors: Zainab H. Mahdi زينب هاشم مهدي --- Rafia H. Al-Suhaili رافع هاشم السهيلي --- Zain El-Abdin Raouf زين العابدين رؤوف
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2016 Volume: 22 Issue: 8 Pages: 103-124
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This study involves the design of 24 mixtures of fiber reinforced magnetic reactive powder concrete containing nano silica. Tap water was used for 12 of these mixtures, while magnetic water was used for the others. The nano silica (NS) with ratios (1, 1.5, 2, 2.5 and 3)% by weight of cement, were used for all the mixtures. The results have shown that the mixture containing 2.5% NS gives the highest compressive strength at age 7 days. Many different other tests were carried out, the results have shown that the carbon fiber reinforced magnetic reactive powder concrete containing 2.5% NS (CFRMRPCCNS) had higher compressive strength, modulus of rupture, splitting tension, stress in compression and strain in compression than the corresponding values for the carbon fiber reinforced nonmagnetic reactive powder concrete containing the same ratio of NS (CFRNRPCCNS). The percentage increase in these values for CFRMRPCCNS were (22.37, 17.96, 19.44, 6.44 and 25.8)% at 28 days respectively, as compared with the corresponding CFRNRPCCNS mixtures.

تضمنت هذه الدراسة تصميم 24 خلطة من خرسانة المساحيق الفعالة الممغنطة المسلحة وغير المسلحة بألالياف، حيث تم أستخدم ماء الإسالة في اعداد 12 خلطة منها أما الـ 12 خلطة الأخرى فقد أستخدم الماء الممغنط في خلطها ، تم استخدام النانو سيليكا بنسب (1، 1,5، 2، 2,5 و3)% من وزن السمنت لجميع الخلطات وبينت النتائج إن الخلطة الحاوية على 2,5% نانو سيليكا أعطت أعلى مقاومة انضغاط بعمر 7 أيام. أجريت فحوصات أخرى مختلفة على النماذج، وبينت النتائج أن فحوص مقاومة الانضغاط , الانثناء, شد الانفلاق, إجهاد الضغط وانفعال الضغط, لخرسانة المساحيق الفعالة الممغنطة المسلحة بالياف الكاربون والحاوية على 2,5 % نانو سليكا أعلى من الخرسانة الغير ممغنطة حيث أبدت النتائج زيادة في قيم الفحوصات للخرسانة الممغنطة بنسب (22,37, 17,96, 19,44, 6,44 و 25,8) % عند العمر 28 يوم على التتابع مقارنة بنفس الخلطات الخرسانية الغير ممغنطة.

Listing 1 - 7 of 7
Sort by
Narrow your search

Resource type

article (7)


Language

English (7)


Year
From To Submit