research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Heart Disease Classification By Genetic Algorithm

Authors: Zainab Falah Hasan --- Asraa Abdalluh Hussein
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2016 Volume: 24 Issue: 9 Pages: 2389-2388
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Classification is predicting of a correct output for related inputs. This is done by using many techniques, some of them depends on a training process that uses set of features and its related output. In the training process, the algorithm finds the relationships between the features and its related output. In this work, classification heart disease is done using genetic algorithms. Genetic algorithm is used to get best successful system of classification. The chromosome consists of the states using for classification, this means every gene acts state from database. Database is clustered to chromosome to find fitness of chromosome(accuracy of classification).

التصنيف هو التنبؤ بالاخراج الصحيح للمدخلات المرتبطة.هذا يتم باستخدام عدة تقنيات , بعض منها يعتمد على عملية التدريب التي تستخدم مجموعة من الخصائص و الاخراج المرتبط بها. في عملية التدريب, الخوارزمية تجد العلاقة بين الخصائص والاخراج المرتبط بها. في هذا العمل, تصنيف مرض القلب يتم باستخدام الخوارزمية الجينية. الخوارزمية الجينية تستخدم للحصول على افضل نظام ناجح للتصنيف. الكروموسوم يتكون من الحالات المستخدمة للتصنيف, هذا يعني انه كل جين يمثل حالة من قاعدة البيانات. قاعدة البيانات يتم عنقدتها الى الكروموسوم لايجاد صلاحية الكروموسوم(دقة التصنيف).


Article
Optimization of Ethylene Refrigeration System Using Genetic Algorithms Method
إختيار الظروف المثلى لأنظمة تبريد الأثيلين باستخدام الطريقة الخوارزمية الجينية

Authors: Shurooq Talib Al-Hemeri --- Mumtaz A. Yousif --- Ahmed M. AL Barifcani
Journal: Journal of Petroleum Research & Studies مجلة البحوث والدراسات النفطية ISSN: 22205381 Year: 2016 Volume: 272 Issue: 13 Pages: 1-37
Publisher: Ministry of Oil وزارة النفط

Loading...
Loading...
Abstract

Ethylene refrigeration for gases separation at low temperature and high pressure for olefin production is an important technique in the chemical industry. Since small changes in the operating conditions of such a process can have a significant influence on its economics, optimization is desirable. The present work was aimed to propose and establish a mathematical model for the ethylene refrigeration system of the ethylene plant in Basrah petrochemical complex NO.1 (PC1) and reformulated as a geometric programming problem using Visual Basic for predicting:- (overall efficiency of the ethylene refrigeration system {% }and percent of energy saving %E). Through the formulated model shaft work consumption by the centrifugal compressor, refrigeration effect and coefficient of performance of the system were obtained and other parameters concerning the system. The results of simulation showed a good agreement with the manufacturer manual.In this study the effect of four factors as independent variables on the overall refrigeration system efficiency and percent of energy saving were studied ;evaporator low pressure (PL) in the range of (1-3)bar ,compressor discharge high pressure (Ph) in the range of ( 28-32)bar ,condenser degree of sub-cool temperature (Tsub-D) in the range of (6-22)0C and evaporator degree of superheat temperature (Tsup-D) in the range of (1-5)0C. And the optimum conditions that aimed to minimize the thermodynamic irreversibility i.e (maximize overall refrigeration system efficiency) and also lower operating cost i.e (maximize percent of energy saving) evaporator low pressure (PL) (2.8 bar), compressor discharge high pressure (Ph) (28.7 bar), condenser degree of sub-cool temperature (Tsub-D) (190C), and evaporator degree of superheat temperature (Tsup-D) (3.40C). At these conditions the overall refrigeration system efficiency is (81.8%) and percent of energy saving is 51.18% with respect to conditions in the factory.Ke

إن أنظمة التبريد بإستخدام غاز الاثيلين كمادة تبريد من العمليات المهمة لأغراض فصل الغازات في الصناعات الكيمياوية عند الضغط العالي و درجة الحرارة الواطئة. و لهذا فإن أي تطور بالظروف التشغيلية للنظام ولو كان قليلاً فإنه يؤثر بشكل ملحوظ على اقتصاديات العملية أي إنه يوفر الكثير من المال . الدراسة الحالية تهدف لإقترح موديل رياضي لنظام تبريد الأثيلين الموجود في وحدة الأثيلين في المجمع البتروكيمياوي رقم (1) و قد تم بناء برنامج بالحاسبة الإلكترونية بلغة Visual Basic)) يستخدم لتحديد الكفاءة الكلية للدورة و النسبة المئوية لخزن الطاقة و بمختلف الظروف التشغيلية و تم من خلاله حساب الشغل المستهلك بواسطة الضاغطة المركزية و سعة التبريد و معامل اداء النظام بالإضافة إلى العديد من العوامل المتعلقة بالنظام . إن نتائج التحليل الرياضي أظهرت تقارب جيد بين القيم الناتجة من عمل البرنامج و بين القيم الحقيقية لنظام التبريد حيث تم دراسة أربعة متغيرات رئيسية في الدورة هي ضغط المبخرات المنخفض ، الضغط العالي الناتج من الكابسة ، درجة الحرارة الناتجة من المكثفات و درجة الحرارة الناتجة من المبخرات و ضمن المدى bar (1-3) ، (28-32) bar ، (6-22)oC و (1-5)oC على التوالي . وكانت النتائج التي تم الحصول عليها هي : (2.8 bar) لضغط المبــــخرات المنخفض ، (28.7 bar) للضغط العالي الناتج من الكابسة ، (19oC) لدرجة الحرارة الناتجة من المكثفات و (3.4 oC) لدرجة الحرارة الناتجة من المبـخرات . و نتائج الدراسة أظهرت إن زيادة ضغط المبخرات المنخفض يؤدي إلى تحسن الكفاءة في النظام و كذلك زيادة حزن الطاقة لكن الزيادة بالضغط العالي الناتج من الكابسة يؤدي إلى خفض كفاءة النظام و التقليل من خزن الطاقة .

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic and English (1)

English (1)


Year
From To Submit

2016 (2)