research centers


Search results: Found 5

Listing 1 - 5 of 5
Sort by

Article
Effect of Re-vibration Process on Axial Capacity of Short Reinforced Concrete Circular Columns

Author: S.A. Abbas
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2017 Volume: 35 Issue: 7 Part (A) Engineering Pages: 776-787
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

A considerable amount of research work has been performed on the effects of vibrating of fresh concrete on the reduction of shrinkage and creep, the improvement bond stress between reinforcing bar and concrete, reduction the concrete permeability and improvement of the mechanical properties of concrete (tension and compression). Series of tests on reinforced concrete circular column, cubes and cylinders were carried out to study the effect of re-vibration duration on axial strength of column, compression strength of concrete cubes, and tensile strength of cylinders. Different compressive strengths of concrete and different size of aggregate were considered in this investigation. The test results show that, the re-vibration operation improves the tensile and compressive strength of concrete. The stiffness of columns increased with increasing the re-vibration duration up to1.5 times the initial vibration duration. Size of aggregate has significant effect on the improvement properties of concrete due to re-vibration. Increase the time duration of re-vibration delay the appearance of first crack.


Article
Estimating Elastic Buckling Load for an Axially Loaded Column Bolted to a Simply Supported Plate using Energy Method

Author: Mustafa Kamal Al-Kamal
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2017 Volume: 20 Issue: 5 Pages: 1154-1159
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

This paper deals with the elastic stability of a column bolted at its mid-height to a simply supported square plate and subjected to a concentrated load, using energy method. A uniform homogeneous column is assumed to be pinned at both ends. From symmetry considerations, half of the column is modeled by making the plate acting as a torsion spring on the column at its mid-height. The column length and cross-section, plate dimensions and thickness, and the material properties for the column and the plate catch the interest of the author. The problem is solved by using energy method and ultimately, the elastic buckling load is found. The analytical elastic buckling load is compared with a numerical solution obtained from finite element method using SAP2000. The numerical results agree with the analytical solution. The finite element model is refined to catch the actual effect of the bolted plate on the elastic buckling load. It has been found that the elastic buckling load is increased due to the increase in the rotational stiffness provided from the plate.

تتناول هذه الدراسة الاستقرار المرن لعمود مربوط بلوح مربع بسيط الاسناد في منتصف الارتفاع ومعرض الى حمل مركز، وذلك باستخدام طريقة الطاقة، حيث تم فرض ان العمود متجانس ومسمر في نهايتيه. من خلال اخذ التماثل بنظر الاعتبار، تم تمثيل نصف العمود فقط وجعل البلاطة عبارة عن نابض (لي) يؤثر على العمود في منتصف الارتفاع. ان طول العمود وابعاد المقطع وابعاد البلاطة وسمكها ومواصفات مادة العمود والبلاطة هي حالة جلبت انتباه الباحث. تم تحليل المسالة باستخدام طريقة الطاقة وفي النهاية تم الحصول على حمل الانبعاج المرن. تمت ايضا مقارنة الحمل التحليلي المرن مع الحل العددي الذي تم الحصول عليه بواسطة طريقة العناصر المحددة باستخدام برنامج SAP2000. اظهرت النتائج العددية توافق تام مع الحل التحليلي. اخيرا تم صقل المسالة لدراسة التاثير الحقيقي للبلاطة على حمل الانبعاج المرن حيث وجد ان حمل الانبعاج المرن قد ازداد نتيجة لزيادة الصلابة الدورانية في البلاطة.


Article
EXPERIMENTAL STUDY FOR BEHAVIOR OF (WASTE CONCRETE FILLED STEEL TUBULER) COLUMNS SUBJECTED TO A STATIC AXIAL LOADS

Author: Zaid Ali Kadhim Alzaidi
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2017 Volume: 10 Issue: 3 Pages: 291-298
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

In this study, composite columns have been tested under axial load. The steel tubes were filled with waste concrete to perform the composite action. The specimens divided into two groups; square and circular columns. The diameter of the circular hallow columns was 7.5 cm with 2mm thickness, while the dimension of the square hallow columns was (7.5 cm × 7.5 cm) with 2mm thickness. For each group a column without waste concrete filled steel tubular (W.C.F.S.T) was tested to act as a reference column. Load-deflection curves were constructed for all specimens. The results indicate that the waste concrete filled steel tube has more capacity due to the composite action. The pattern of failure in circular sections was different from the failure pattern of the square ones.


Article
EXPERIMENTAL STUDY ON STRUCTURAL BEHAVIOR OF THIN WALL CONCRETE PANELS SUBJECTED TO AXIAL ECCENTRIC UNIFORMLY DISTRIBUTED LOADING
دراسة السلوك الإنشائي للألواح الجدارية الخرسانية النحيفة المعرضة الى تحميل محوري لامركزي منتشر

Authors: Aya Haqi Ismael --- Layth A. Al-Jaberi --- Saad Khalaf Mohaisen
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2017 Volume: 21 Issue: 1 Pages: 51-64
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Due to the current popularity of reinforced concrete (RC) wall construction, and the new published of codes of concrete, RC walls have become just as an important structural elements as beam, slabs and columns. This paper presents an experimental study of structural behavior of thin concrete wall panels subjected to axial eccentric uniformly distributed loading with varying aspect ratio (AR=H/L) and concrete type (concrete strength (f 'c)). The experimental program included testing of six two-way thin concrete wall panels, fixed at all sides and applying the load axially with eccentricity equal to wall thickness/6).The results indicate that the load carrying capacity of the normal strength concrete (NSC) wall panels decreased with the increase in AR (H/L) from 1.25 to 2.00, the ultimate load reduced from 37.5% to 14.6 % when AR decreased from 2.00 to 1.25. For Reactive Powder Concrete (RPC), the ultimate load reduced from 38.7% to 16% when AR decreased from 2.00 to 1.25. The strength of the concrete wall increases with the increase in concrete strength (f 'c) from 33.5 MPa to 120.4 MPa , the increase is about (212.5, 207.3, 206.67) % for panels with H/L = (1.25, 1.50, 2.00) respectively. The lateral deflections of concrete wall panels depend on the aspect ratio (H/L) where, the increase in aspect ratio (H/L) from 1.25 to 2.00 of NSC panels causes increasing the lateral deflection of the concrete wall panels, while for Reactive Powder Concrete (RPC) wall panels the increase in aspect ratio (H/L) from 1.25 to 2.00 causes decreasing in the lateral deflection of the concrete wall panels. Also the lateral deflection depends on concrete type (concrete strength (f 'c)), when strength of the concrete wall panel increases from 33.5 to 120.4 MPa, the lateral deflection decreases.

نظرا للانتشار الأخير للبناء بالجدران الخرسانية المسلحة, والمدونات الجديدة الأميركية المنشورة لمعهد الخرسانة الأميركي ACI-Code, أصبحت الجدران الخرسانية عنصر انشائي هام مثل العتبات، والسقوف والأعمدة. هذا البحث يقدم دراسة للسلوك الانشائي للألواح الجدارية الخرسانية النحيفة المعرضة الى تحميل محوري لامركزي موزع بانتظام مع نسب مختلفة من نسبة الارتفاع على العرض(Aspect Ratio) ونوعية الخرسانة ( مقاومة الخرسانة (f 'c)). البرنامج يتضمن فحص ستة نماذج من الألواح الجدارية (two-way action) الخرسانية النحيفة المثبتة بكل الجوانب وتسليط الحمل محوريا مع لا مركزية مساويه الى السمك مقسم على ستة (t/6). النتائج تشير إلى أن مقاومة الجدران الخرسانية (مقاومة الحمل العمودي) ذات المقاومة الاعتيادية تقل مع الزيادة في نسبة الارتفاع على العرض (H/L) من (1.25 الى 2.00), ), الحمل الاقصى انخفض من 37.5٪ إلى 14.6٪ عندما انخفضت نسبة (H/L) من 2.00 الى 1.25. ولجدران خرسانة المساحيق الفعالة (RPC)، الحمل الاقصى انخفض من 38.7٪ إلى 16٪ عندما انخفضت نسبة (H/L) من 2.00 الى 1.25. المقاومة للجدران الخرسانية تزداد مع الزيادة في مقاومة الخرسانة للانضغاط (f 'c) من 33.5 (MPa) إلى 120.4 (MPa). كانت الزيادة (212.5، 207.3، 206.67) ٪ للجدران مع H/L = (1.25 ، 1.50، 2.00) على التوالي. الازاحة الجانبية للألواح الجدارية الخرسانية يعتمد على نسبة الارتفاع على العرض (H/L) حيث أن الزيادة في نسبة الارتفاع على العرض (H/L) من 1.25 الى 2.00 لجدران المقاومة الاعتيادية (NSC) يسبب زيادة الازاحة الجانبية للألواح الجدارية الخرسانية، في حين أن جدران خرسانة المساحيق الفعالة RPC)) الزيادة في نسبة الارتفاع على العرض من 1.25 الى 2.00 يسبب تناقص في الازاحة الجانبية للألواح الجدارية الخرسانية. الازاحة الجانبية يعتمد أيضا على نوع الخرسانة (مقاومة الخرسانة للانضغاط (f 'c))، عندما تزداد مقاومة الخرسانة من (33.5 الى 120.4) (MPa)، يقلل من الازاحة الجانبية.


Article
Behavior of Reinforced Concrete Columns Subjected to Axial Load and Cyclic Lateral Load
سلوك الاعمدة الخرسانية المسلحة المعرضة لحمل محوري مع حمل جانبي ترددي

Authors: Akram Ghulam Awazli أكـرم غـلام عـوازلي --- Rafaa Mahmood Abbas رافع محمود عباس
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2017 Volume: 23 Issue: 2 Pages: 21-40
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Columns subjected to pure axial load rarely exist in practice. Reinforced concrete columns are usually subjected to combination of axial and lateral actions and deformations, caused by spatially‐complex loading patterns as during earthquakes causes lateral deflection that in turn affects the horizontal stiffness. In this study, a numerical model was developed in three-dimensional nonlinear finite element and then validated against experimental results reported in the literatures, to investigate the behavior of conventionally RC columns subjected to axial load and lateral reversal cyclic loading. To achieve this goal, numerical analysis was conducted by using finite element program ABAQUS/Explicit. The variables considered in this study were axial load index, concrete compressive strength, column aspect ratio, longitudinal and transverse reinforcement ratios. According to numerical case studies, the results revealed that axial load index and longitudinal reinforcement ratio have the most impact on the column response. Also, increasing concrete compressive strength and reducing column aspect ratio resulted in increasing strength capacity of the column. Moreover, increasing lateral confinement by transverse reinforcement at the column ends increases the flexural strength of a flexure-controlled RC columns.

ان الأعمدةُ المعرضة إلى حملِ محوريِ فقط قليلة جدا في الواقع العملي. حيث تتعرض الأعمدة الخرسانية المسلحة في الاغلب إلى تأثيرات تضم قوى محورية وجانبية والى تشوهاتِ، سببها أنماط تحميل معقدة في الفضاء (ثلاثية الابعاد) اثناء زلزال مثلا، مُسَبِّبة الازاحة الجانبية التي تُؤثّرُ بدورها على الجسائة الأفقية. في هذه الدراسة، تم تطويرُ نموذجَ لا خطّي ثلاثي الأبعادِ من نماذجِ العناصرِ المحدودةِ ِ ومن ثم التثَبَّتَ من صحة النتائج بالمقارنة مع النتائج التجريبية المثبتة بأدبيات البحوث، للتعرف على سلوك الاعمدة الخرسانية المسلحة الشائعة المعرضة لأحمال محورية وجانبية عكسية ترددية. ولتحقيق الهدف، اجري التحليل العددي باستخدام طريقة العناصر المحددة بواسطة برنامج ABAQUS/Explicit. المتغيرات التي تم دراستها في هذا البحث هي مؤشر الحمل المحوري، قوة انضغاط الخرسانة، ونسبة الارتفاع الى العرض، ونسبة التسليح الطولي والعرضي. وفقا للدراسة العددية، اظهرت النتائج ان مؤشر الاحمال المحورية ونسبة التسليح الطولي لهما التأثير الاهم على استجابة العمود. كما ان زيادة قوة انضغاط الخرسانة اوتقليل نسبة الارتفاع الى العرض للاعمدة فأن ذلك يؤدي الى زيادة في قدرة مقاومة العمود. بالاضافة لذلك ان زيادة الحصر الجانبي بواسطة التسليح المستعرض في نهايات العمود يؤدي لزيادة مقاومة الانثناء للاعمدة التي يغلب عليها فشل الانثناء.

Listing 1 - 5 of 5
Sort by
Narrow your search

Resource type

article (5)


Language

English (5)


Year
From To Submit

2017 (5)