research centers


Search results: Found 9

Listing 1 - 9 of 9
Sort by

Article
Study the Characterization of Adding Polymer-Surfactant Agent on the Drag Reduction Phenomena in Pipeline Flow System
دراسة خصائص امكانية مزج بوليمر مع مواد تقليل الشد اسطحي وتاثيرها على ظاهرة تقليل الاحتكاك باستخدام نظام انابيب جريان

Author: Sahar A. Dawood سحر عبد الهادي داوود
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2017 Volume: 13 Issue: 2 Pages: 79-89
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this study, the effect of carboxylic methyl cellulose (CMC), and sodium dodcyl benzene sulfonate (SDBS) as an aqueous solution on the drag reduction was investigated. Different concentrations of (CMC) and (SDBS) such as (50, 100, 150, 200, 250, 300, 350, 400, 450, and 500 ppm) were used to analyze the aqueous solution properties, including surface tension, conductivity, and shear viscosity. The optimum four concentrations (i.e., 50, 100, 200, and 300 ppm) of fluid properties were utilized to find their effect on the drag reduction. Two different PVC pipe diameters (i.e., 1" and 3/4") were used in this work. The results showed that blending CMC with SDBS gives a good drag reduction percent about (58%) more than using them individually, friction factor decreasing with increasing Reynolds number and gives good agreement with von Karamn equation and maximum drag reduction (MDR) asymptote. Reynolds number, pipe diameter, and polymer-surfactant concentrations were considered as influencing factors. In addition, critical micelle concentration, the onset of drag reduction, and the interactions between the mixed additives were discussed.

في هذا البحث تم دراسة تأثير استخدام كاربوكسيل مثيل سليلوز, وصوديوم دودسيل بنزين سلفونيت بوصفها محاليل مائية على ظاهرة تقليل ألأعاقة لجريان السوائل من خلال الانابيب. تراكيز مختلفة من هذه المواد مثل ( 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 جزء من المليون) تم استخدامها لتحليل خواص هذه المحاليل المحضرة باستخدام هذه المضافات والتي تشمل "الشد السطحي, التوصيلية الكهربائية, واللزوجة" لكل من المضافات المستخدمة منفصلة و ممزوجة وبتراكيز مختلفة. افضل اربعة تراكيز مثل ( ,50100, 200, 300 جزء من المليون) من خواص المحاليل المدروسة تم استخدامها لدراسة تأثيرها على ظاهرة تقليل ألأعاقة لجريان السوائل ,أستخدمت انابيب (PVC) مختلفة الاقطار (1 انج, 3/4 انج ) لدراسة تاثير هذه المضافات منفصلة وممزوجة بوصفها مواد مقللة للاحتكاك عند جريان السوائل خلال هذه الانابيب. النتائج أوضحت امكانية المزج واعطت نسبة تقليل اعاقة حوالي 58 % اعلى مما لو استخدمت منفصلة , تناقص معامل الاحتكاك مع تزايد عدد رينولدز و توافق جيد مع معادلة فون كارامن و MDR asymptote . عدد رينولدز, قطر الانابيب تركيز المضافات كلها تعد عوامل مؤثرة وقد تم مناقشة كل من التركيز الحرج لتكوين المذيلات وبداية ظاهرة تقليل الاعاقة والتداخلات بين المضافات الممزوجة.


Article
Evaluations of Potable Water Tanks Epoxy Coatings Performance Using Electrochemical Impedance Spectroscopic Method
تقويم أداء طلاء الايبوكسي لخزانات مياه الشرب باستخدام طريقة الممانعة الكهروكيميائية الطيفية

Author: Haider Hadi Jasim حيدر هادي جاسم
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2017 Volume: 13 Issue: 2 Pages: 90-99
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The aim of this paper is to investigate and discuss the mechanisms of corrosion of epoxy coatings used for potable water tanks. Two distinct types of Jotun epoxy coatings: Tankguard 412 contained polyamine cured epoxy and Penguard HB contained polyamide cured epoxy, were tested and studied using the electrochemical impedance spectroscopic (EIS) method. The porosity of epoxy coatings was determined using EIS method. The obtained results showed that the two epoxy coatings have excellent behavior when applied and tested in potable water of Basrah city. Polyamine is more resistance to water corrosion compared to polyamide curing epoxy and has high impedance values. Microscopic inspection after test showed that the polyamine cured epoxy has blistering while the surface of polyamide cured epoxy showed pitting and blisters.

الهدف من هذا البحث، تحقيق آليات التآكل لطلاء الايبوكسي المستخدم في طلاء خزانات المياه الصالحة للشرب ومناقشتها. هناك نوعان مختلفان من طلاء الايبوكسي لشركة جوتن هما : Tankguard 412 تحتوي على ايبوكسي البولي أمين و Penguard HBالمحتوي على ايبوكسي البولي اميد تم اختبارها ودرستها باستخدام طريقة الممانعة الكهروكيميائية الطيفية (EIS ). وتم تحديد المسامية لطلاءات الايبوكسي باستخدام طريقة EIS . أظهرت النتائج المستحصل عليها أن كلا الطلائين اظهرا أداء ممتاز عند تطبيقهما واختبارهما في المياه الصالحة للشرب من مدينة البصرة . لكن الطلاء المحتوي على البوليامين هو الأكثر مقاومة للتآكل مقارنة مع الطلاء الذي يحتوي مادة البولي أميد وامتلك أيضا قيمة اعلى من الممانعة. الفحص المجهري بعد الاختبار بين أن السطح المطلي بطلاء الايبوكسي البوليامين اظهربثور وحبيبات على السطح بينما السطوح المطلية بطلاء مادة البولي أميد اظهر تنقرا وتجاويف على السطح.


Article
Enhancement of Heat Exchanger Performance by Using Dimpled Tube
تحسين اداء المبادل الحراري باستخدام الانابيب المندبة

Author: Falah F. Al-Jabery فلاح فاخر حاتم الجابري
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2017 Volume: 13 Issue: 4 Pages: 41-49
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The enhancement of heat exchanger performance was investigated using dimpled tubes tested at different Reynolds numbers, in the present work four types of dimpled tubes with a specified configuration manufactured, tested and then compared performance with the smooth tube and other passive techniques performance. Two dimpled arrangements along the tube were investigated, these are inline and staggered at constant pitch ratio X/d=4, the test results showed that Nusselts number (heat transfer) of the staggered array is higher than the inline array by 13%. The effect of different depths of the dimple (14.5 mm and 18.5 mm) has been also investigated; a tube with large dimple diameter enhanced the Nusselts number by about 25% for the range of Reynolds number between 4000- 20000. The overall enhancement ratio was used to differentiate the passive technique and comparison of different configurations for the technique itself, the result depicted that the 10 mm dimple diameter with a pitch ratio of X/d= 4 gives better performance than the static mixer and twisted tape techniques. The overall enhancement ratio of the 10 mm dimple diameter is varied from (1.21 to 1.65) that means good performance for a range of Reynolds numbers (4000-20000). This indicates that 21- 65 % of heat transfer area can be saved at the same pumping power compared with the smooth tube heat exchanger.

تم في هذا البحث دراسة تحسين اداء المبادلات الحرارية باستخدام الانابيب المندبة وتم لهذا الغرض تصنيع اربع نماذج مختلفة الاشكال واختبارها ومقارنة ادائها الحراري مع الانبوب الاملس. تمت دراسة تاثير ترتيب الندب على طول الانبوب ( متناظر , متخالف) عند (X/d=4) بينت النتائج العملية ان معدل انتقال الحرارة )عدد نصلت) للانابيب متخالفة الندب اكبر ب 13% من الانابيب متناظرة الندب. كذلك تم دراسة تاثير قطر الندبة (14.5mm,18.5mm) واظهرت النتائج تحسن عدد نصلت وبالتالي انتقال الحرارة بنسبة 25% عند استخدام انبوب بقطر كبير لمدى عدد رينولدز يتراوح بين 4000-20000 . استخدمت نسبة التحسين الكلية للمقارنة بين التقنية الحالية والتقنيات السلبية المستخدمة في تحسين اداء المبادلات الحرارية وكذلك للمقارنة بين نماذج البحث الحالية اظهرت النتائج ان الانبوب ذا الندب بقطر 10mm وخطوة X/d=4 تعطي اداء افضل من الاساليب السلبية المختلفة لتحسين الاداء وكانت النتائج تشير الى ان الانابيب المزودة بالندب المتخالفة تعطي اداء افضل من اسلوب استخدام الخلّاط وكذلك من اسلوب استخدام الاجزاء الملتوية . تتراوح نسبة التحسين الكلية بين 1.21الى 1.65 وهذا يعني اداء حرارياً جيداً عند مديا عدد رينولدز 4000-20000 اي تخفيضاً في مساحة انتقال الحرارة بنسبة 21-65% لقدرة الضخ نفسها مقارنة مع استخدام الانبوب الاملس.


Article
Experimental Investigation of the Dynamics of Laboratory Simple Surge Tank

Authors: Saib A. Yousif صائب يوسف --- Ali Nasir Kalaf علي ناصر خلف
Journal: Basrah Journal for Engineering Science مجلة البصرة للعلوم الهندسية ISSN: Print: 18146120; Online: 23118385 Year: 2017 Volume: 17 Issue: 2 Pages: 38-42
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

The surge tank is one of important control devices inreducing water Hummer effect on distributed network pipingsystem and hydropower stations. An experimental study wasconducted into a simple surge tank of 0.044 m in a diameterwith upstream constant head reservoir of a height, 0.881 mand a water transporting pipe of a size 0.0202 m.Results indicate that rapid closure of a downstream valvecauses under-damped stable oscillation in a surge tank.Experimental response agreed well with theoretical resultswhen friction factor is considered to be variable, but with 85% increases in settle time and more oscillations when constantfriction factor is recognized at initial value before valveclosure. Doubling surge tank area does not improve thedynamics properties; otherwise, Thoma area must be avoidedfor small sizes. Comsol multiphysics software 3.5 is used todeal with the dynamics of the surge tank numerically.


Article
Numerical Investigations on Heat Flow of Nanofluids in Ribs Tube Configurations
دراسة عددية للتدفق الحراري للموائع في الأنبوب ذي النتوءات

Authors: Ramzi Ata Abd Alsaheb رمزي عطا عبد الصاحب --- Sami D. Salman سامي داود سلمان
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2017 Volume: 13 Issue: 3 Pages: 10-17
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this paper presents two dimensional turbulent flow of different nanofluids and ribs configuration in a circular tube have been numerically investigation using FLUENT 6.3.26. Two samples of CuO and, ZnO nanoparticles with 2% v/v concentration and 40 nm as nanoparticle diameter combined with trapezoidalribs with aspect ratio of p/d=5.72 in a constant tube surface heat flux were conducted for simulation. The results showed that heat flow as Nusselt number for all cases raises with Reynolds number and volume fraction of nanofluid, likewise the results also reveal that ZnO with volume fractions of 2% in trapezoidal ribs offered highest Nusselt number at Reynolds number of Re= 30000.

في هذا البحث تم دراسة تأثيرالجريان المضطرب للموائع النانوية في انبوب دائري ذي النتوءات ثنائية الأبعاد عدديا باستخدام برنامجFLUENT 6.3.26 .تم أستخدام نموذجين الجسيمات النانوية كأوكسيد الزنك وأوكسيد النحاس بتركيز حجمي يصل الى %2 و 40 نانومتر قطر الجسيمات النانوية في انبوب ذي نتوؤات بشكل شبه منحرف نسبةطول ضلع النتوء الى قطر الأنبوبتصل الى p / d = 5.72تحت تدفق ثابت للحرارة السطحية للمحاكاة. وأظهرت النتائج أن تدفق الحرارة عددا نسلت لجميع الحالات يزداد بزيادة رينولدز وبتركيز الحجمي للموائع النانوية كما أظهرت النتائج أيضا أن أوكسيد الزنك بتركيز حجمي يصل الى %2 في انبوب ذو نتوؤات بشكل شبه منحرف أعلى قيمة مع حجم الكسور من 2٪ في الأضلاع شبه منحرف عرضت أعلى لعدد النسلت عندما يصل عدد رينولدز الى 30000.


Article
Augmentation of Nanofluids Heat transfer in a Circular Tube with Baffled Winged Twisted Swirl Generator
تحسين الأنتقال الحراري للموائع النانوية في أنبوب دائري مجهز بصفيحة ملتوية ذات الأجنحة لتوليد الدوامات

Authors: Ramzi Ata Abd Alsaheb رمزي عطا عبد الصاحب --- Sami D. Salman سامي داود سلمان
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2017 Volume: 13 Issue: 4 Pages: 89-97
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This article introduces a numerical study on heat exchange and corrosion coefficients of Zinc–water nanofluid stream in a circular tube fitted with swirl generator utilizing CFD emulation. Different forms of swirl generator which have the following properties of plain twisted tape (PTT) and baffle wings twisted tape (BTT) embeds with various ratio of twisting (y = 2.93, 3.91 and 4.89), baffle inclination angles (β = 0°, - 30° and 30) joined with 1%, 1.5% and 2% volume fraction of ZnO nanofluid were utilized for simulation. The results demonstrated that the heat and friction coefficients conducted by these two forms of vortex generator raised with Reynolds number, twist ratio and baffle inclination angles decreases. Likewise, the results showed that the heat transfer rate raised with accretion of ZnO nanoparticle concentration. Furthermore, the maximum rate of heat transfer with significant intension in friction coefficient has been produced by baffle wings tape with ratio of twisting y=2.93 and baffle angle β= -30 with 2% volume fraction of ZnO nanofluid.

يقدم هذا البحث دراسة عددية عن التبادل الحراري ومعاملات الأحتكاك لتدفق المائع النانوي من الزنك والماء في أنبوب دائري مزود بمولد دوامة باستخدام ديناميك الموائع الحاسوبي. وقد استخدمت أشكال مختلفة من مولد الدوامات التي لها الخصائص الاتية: الصفيحة الملتوية الكلاسيكية، الصفيحة الملتوية ذات الأجنحة وبنسبة التواء (y = 2.93, 3.91 and 4.89)، وبزوايا ميل للجناح (β = 0°, - 30° , 30°) مع الجسيمات النانوية كأوكسيد الزنك وبتركيز حجمي يصل الى (1%,1.5, 2%) للمحاكاة. وقد أظهرت النتائج أن معاملات الحرارة والاحتكاك التي أجريت لهذين الشكلين من مولد الدوامات قد أزدادت بزيادة عدد رينولدز، ونقصان نسبة التواء الصفيحة وزواية ميل الجناح للصفيحة، كما أظهرت النتائج أن معدل انتقال الحرارة قد أزداد بزيادة تركيز الجسيمات النانوية لأوكسيد الزنك. علاوة على ذلك، فإن الحد الأقصى لمعدل انتقال الحرارة مع زيادة ملحوظة في معامل الاحتكاك تم الحصول عليها الصفيحة الملتوية ذات الأجنحة وبنسبة التواء (y=2.93) وبزاوية ميل تصل الى (β = - 30°) مع تركيز حجمي لأوكسيد الزنك النانوي يصل الى %2 .


Article
AUGMENTATION OF HEAT TRANSFER IN CORRUGATED TUBE USING FOUR-START SPIRAL WALL

Author: Ghassan Fadhil SMAISIM
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2017 Volume: 10 Issue: 4 Pages: 451-467
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

This article dealt with an important heat transfer field, which is passive heat transfer technique represented by corrugated tube. The study conducted numerically by ANSYS Fluent 14. The motivation behind the current study was to clarify the characteristics and merits of such tube geometry in terms of heat transfer and pressure drop. The obtained results reported under constant heat flux, temperature-dependent thermo-physical properties and Reynolds number range of 300-1500. Results show good heat transfer enhancement of 6.15-33.24% in spite of an increase in friction factor of 1.80-2.93 times the smooth values. The corrugated tube with φ =4.76×10-2 has the top thermal 1.16-1.25 for all Reynolds number. The most important finding is that the gained heat transfer is much more than the increase in pressure loss until a certain threshold of Reynolds number about 900, later, the pressure loss increase and dominates over the heat gained. The effect of Prandtl number on the heat transfer for three types of fluids produced too. A criterion correlation equation of Nusselt number developed to describe the cases of four starts spirally corrugated tubes by deviation ±3% compared with the simulation results.


Article
The Dynamic Behavior of Water Flowing Through Packed Bed of Different Particle Shapes and Sizes
السلوك الديناميكي للماء اثناء جريانه خلال عمود محشولجسيمات مختلفة الاشكال والاحجام

Authors: Haneen Ahmed Jasim حنين احمد جاسم --- Sarmad Talib Najim سرمد طالب نجم
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2017 Volume: 23 Issue: 12 Pages: 70-81
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An experimental study was conducted on pressure drop of water flow through vertical cylindrical packed beds in turbulent region and the influence of the operating parameters on its behavior. The bed packing was made of spherical and non-spherical particles (spheres, Rasching rings and intalox saddle) with aspect ratio range 3.46 < D/dp < 8.486 obtaining bed porosities 0.396<ε<0.84 and Reynolds number 1217<〖Re〗_p< 21758. The system is consisted of 5 cm inside diameter Perspex column, 50 cm long; distilled water was pumped through the bed with flow rate 875, 1000, 1125, 1250,1375 and 1500 l/h and inlet water temperature 20, 30, 40 and 50 ˚C. The packed bed system was monitored by using LabVIEW program, were the results have been obtained from Data Acquisition Adaptor (DAQ).

تم اجراء دراسة عملية لحساب هبوط الضغط للماء خلال جريانه في وسط عمودي أسطواني محشو ضمن المرحلة المضطربة في ظروف تشغيلية مختلفة تتضمن حشوات ذات اشكال كروية وغير كروية (spheres, Rasching rings and intalox saddle) ذات تعبئة عشوائية وبمعدل8.486


Article
EFFECT OF SALT ADDITION ON THE DRAG REDUCTION BY CATIONIC SURFACTANT
تأثير اضافة الملح على تقليل الاعاقة بالمادة الفعالة سطحيا ذات الشحنة الموجبة

Loading...
Loading...
Abstract

In the present paper, an experimental study has been carried out to study the drag reduction in turbulent flow inside a tube by using surfactant with salt additives, where this phenomena used in many industry applications. Therefore, the flow inside a pipe with high volumetric flow rate requires high power to transport it, so this needs large number of pumps to push it for remote distances and this pumps require great amount of fuels and cyclic maintenance ,so the additives reduce the number of pumps that is required to pump the liquids and so this decrease the cost of pumps, the fuel and maintenance or increases the volumetric flow rate at constant pressure drop. The CTAB surfactant has added with concentrations of 1000,1500 and 2000 ppm, and the salt that is NASAl has added for water at 2000 ppm CTAB concentration with 200 and 400 ppm concentration. The study has excuted with different values of Reynolds number that are 33418,44557,55697, 66836, 77976 and 89115,.Different angles of pipe inclinations has used through the work which are 0˚,3˚and 6˚. The experimental results has correlated by using SPSS program, and solved by multiple nonlinear regression analysis. The power law has found to be the optimum relation that may fits with the data that has obtained from the experimental work .

تم في الرسالة الحالية اجراء دراسة عملية لتقليل الاعاقة في الجريان الاضطرابي داخل انبوب باستعمال بعض المضافات ، تستعمل هذه الظاهرة في كثير من التطبيقات الصناعية. لذلك فان الجريان داخل الانابيب بمعدل تدفق حجمي عالي يحتاج قدرة عالية لنقله ، كما يحتاج عدد كبير من المضخات لكي تضخه لمسافات بعيدة ، وهذه المضخات تحتاج كمية كبيرة من الوقود والصيانة الدورية ، لذلك فان الاضافات تقلل عدد المضخات المطلوبة لضخ السوائل وهذا يقلل كلفة المضخات والوقود والصيانة او زيادة معدل التدفق الحجمي لهبوط ضغط ثابت . المادة الصابونية التي اضيفت هي CTAB بتراكيز1000،1500و2000 جزء بالمليون ، بينما الملح والذي هو NASAl فقد اضيف الى الماء بوجود CTAB بتركيز 2000 جزء بالمليون بتراكيز200 و 400 جزء بالمليون . الدراسة نفذت عند قيم مختلفة لرقم رينولدز وهي33418 ،55697، 44557،66836،77976,89115. عدة قيم لزاوية ميلان الانبوب اخذت بنظر الاعتبار خلال الدراسة وهي 0˚،3˚ و6˚. النتائج العملية قد صححت باستخدام برنامج SPSS وقد اجريت باستخدام تحليل الانحدار اللا خطي ذو المتغيرات المتعددة .ووجد بان العلاقة الاسية هي افضل علاقة تتلائم مع النتائج المستحصلة من العمل التجريبي .

Listing 1 - 9 of 9
Sort by
Narrow your search

Resource type

article (9)


Language

Arabic and English (5)

English (4)


Year
From To Submit

2017 (9)