research centers


Search results: Found 4

Listing 1 - 4 of 4
Sort by

Article
ECG abnormalities in first visit of diabetic patients in Al Sammawah Diabetic center: cohort study

Author: Saad Hallawee
Journal: Muthanna Medical Journal مجلة المثنى الطبية ISSN: 2226146x Year: 2017 Volume: 4 Issue: 1 Pages: 23-34
Publisher: Al-Muthanna University جامعة المثنى

Loading...
Loading...
Abstract

Diabetes Mellitus is a very common progressive endocrine disease in Iraq (and our society) as part of whole world, and diabetic patients are more likely to have cardiovascular diseases than patients without diabetes. ECG is the most widely used simple noninvasive test for evaluation of cardiovascular risk, so our study was focused to assess the relation between the frequency of ECG changes with the patients glycemic control and their age group. A 600 patients with newly diagnosed diabetes Mellitus were identified from diabetic center in Al Sammawah teaching hospital. All are evaluated for variables; age, gender, glycemic control (HbA1c level) and ECG abnormalities. Then they are divided in two groups those with and others without ECG changes during evaluation of their above variables. The selected patients are 294 female and 309 male with most age distribution affected are 50-59 years 189(32%) followed by 40- 49 years,130(22%)then 60-69 age group119 (20%), 30-39 years 68(11%), >70 years 52 (9%) and <30 years about 37(6%). 327 patients with normal ECG and 273 patients with abnormal ECG, female was predominant by 55%, and ECG abnormality was distributed among low voltage in 110 patients (18 %), bradycardia in 54 patients (9%), with variable percent for the other ECG abnormalities. Diabetic control for most of the patients was poor according to HbA1c level which measured in the first visit and 77% of patients with HbA1c above 8. In conclusion; the age group distribution in Samawah city is comparable to the other population, but with very bad diabetic control which require more effective educational and advance therapeutic approaches to control this propagating challenge. ECG changes seen were predominantly low voltage, then bradycardia which may reflect other association which require more future research.

Keywords

Diabetes Mellitus --- ECG --- HbA1c


Article
The Relationship between P-Wave Morphology and Atrial Fibrillation

Authors: Ziad T. Al-Dahan --- Abbas. F.Al-Hashimi --- Natiq. A. Al-Asady
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2017 Volume: 20 Issue: 3 Pages: 701-708
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

The objective of this paper is to develop an efficient P-wave detection algorithm based on the morphology characteristics of arrhythmias using time domain analysis. ECG from normal subjects, and patients with atrial fibrillation were studied. After baseline wander cancellation, power line interference filtration, the step of QRS detection using the pan- Tompkins algorithm is utilized to calculate R peak which represent the reference point to detect P peak. The algorithm was tested with experiments using MIT-BIH arrhythmia database which included Paroxysmal Atrial Fibrillation PAF prediction challenge, Massachusetts Institute of Technology MIT-BIH normal sinus rhythm, long term Atrial Fibrillation AF and MIT-BIH atrial fibrillation where every P-wave was extracted.The results reveal that the algorithm is accurate and efficient to detect and classify arrhythmias resulted from atrial fibrillation.

الهدف من هذه البحث هو تطوير كفاءة خوارزمية الكشف موجة- P استنادا إلى خصائص مورفولوجية عدم انتظام ضربات القلب باستخدام تحليل نطاق الزمن .وتضمنت التجارب العادية اشخاص طبيعين و و تشخاص يعانون من ارتجاف اذيني بعد معالجة الانحراف عن خط الاساس و الغاء او فلتره تاثير مصدر الطاقة . تم استخدام خوارزمية تومبكينزالمستخدمه للكشف عن موجة QRS لحساب قمة موجة R التي تمثل نقطة المرجع للكشف عن قمة الموجة P . تم اختبار الخوارزمية في التجارب باستخدام قاعدة بيانات عدم انتظام ضربات القلب لمعهد ماساتشوستس للتكنولوجيا والتي شملت نوبات الرجفان الأذيني المؤقت والايقاع الطبيعي للنبض و الارتجاف الاذيني المزمن و الارتجاف الاذيني حيث تم استخراج كل موجة P .. بينت النتائج أن خوارزمية دقيقة وفعالة لكشف وتصنيف عدم انتظام ضربات القلب الناتجة عن الرجفان الأذيني

Keywords

Atrial Fibrillation --- P-wave --- QRS --- ECG


Article
Design and Implementation of Fast Ambulatory System for Cardiac Patients Using GSM Network and ECG Signal
تصميم وتنفبذ نظام الاسعاف الفوري لمرضى القلب باستخدام شبكة النظام العالمي للهاتف المحمول )جي إس أم( وإشارة جهاز تخطيط القلب الكهربائي )أي, سي,جي(.

Authors: Ass. Prof. Dr. Mousa K. Wali --- Dr. Abass F. Humadi --- Ass. Prof. Dr. Majid S. Naghmash
Journal: JOURNAL OF MADENAT ALELEM COLLEGE مجلة كلية مدينة العلم الجامعة ISSN: 2073,2295 Year: 2017 Volume: 9 Issue: 1 Pages: 162-173
Publisher: City College of Science University كلية مدينة العلم الجامعة

Loading...
Loading...
Abstract

This paper presents, the design and implementation of fast ambulatory system for cardiac patients by using global system mobile (GSM) network and Electrocardiography (ECG) signal. The early detecting of critical case in the heart performance gave enough time to help the patient with heart disease. Depending on the filter response and ECG band limited signal, the proposed system generate voice alarms to the monitor when the time band of the QRS complex wave in the ECG signal is exceeded the standards duration which indicate that the patients in dangerous condition and arrhythmia may be founded. The FIR filter response analyzed the distorted ECG signal and produce an alarm which will be send by GSM transmitter to the nurse or doctor mobile phone reciever at monitor center when the ECG frequency band jumb over natural frequency and high risk of cardiac patients. The low pass FIR filter performance using kaiser window permit to pass only the natural band otherwise send emergency alarms via GSM mobile phone. Results shows and efficient and hilight observation with each case recording by FDA tool in MATLAB.

تعرض هذه الورقة, تصميم نظام فعال في حالات الطوارئ للمرضى الذين يعانون من أمراض القلب, استناداً إلى إشاراتتخطيط القلب الكهربائية (ECG) باستخدام مرشح عامل تصفية الاستجابة ) FIR ( وشبكة النظام العالمي للهاتف المحمول.(GSM) أنالكشف المبكر للحالة الحرجة في أداء القلب تساعد على تقديم المساعدة للمريض بمرض القلب في وقت مبكراعتماداً على استجابةالمرشح وإشارة الحزمةالمحدودة لتخطيط القلب الكهربائي , أن النظام المقترح يولد الإنذارات الصوتية إلىجهاز العرض عندما تتجاوز وقت الموجة المركبة في إشارة تخطيط القلب الكهربائي لاكرر من 0.08 من الرانية مما يشير إلىأن المريض في حالة خطيرة وعدم انتظام ضربات القلب. أن تحليل إشارة تخطيط القلب الكهربائي المضطربة باستخدام مرشحعامل تصفية الاستجابة ) FIR (يولد إنذار الذي سيرسل عبر شبكة النظام العالمي للهاتف المحمول (GSM) الى متلقي الهاتفالمحمول كالممرضة أو الطبيب عندما تتجاوز ترددات القلب عن التردد الطبيعي في تخطيط القلب الكهربائيوحدوث خطورةعالية لمريض القلب. باستخدام مرشح عامل تصفية الاستجابة ) FIR ( منخفض التمرير باستخدام نافذة كايزر تسمح لتمريرالحزم الطبيعية فقط وإلا سيتم إرسال إنذارات الطوارئ تحت تكنولوجيا البرمجيات الراديو عن طريق الشبكة الدولية للهاتفالنقال GSM . النتائج تظهر كفاءة, وتسلط الضوء على المراقبة مع كل حالة تسجل عن طريق أداة تصميم الفلتر الرقمي )FDA tool ( في MATLAB .


Article
Enhancement of Twins Fetal ECG Signal Extraction Based on Hybrid Blind Extraction Techniques

Authors: Ahmed Kareem Abdullah --- Hadi Adab Hamad --- Nasser Ali Hasson AL-Zubaydi
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2017 Volume: 25 Issue: 4 Pages: 1127-113
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

ECG machines are noninvasive system used to measure the heartbeat signal. It’s very important to monitor the fetus ECG signals during pregnancy to check the heat activity and to detect any problem early before born, therefore the monitoring of ECG signals have clinical significance and importance. For multi-fetal pregnancy case the classical filtering algorithms are not sufficient to separate the ECG signals between mother and fetal. In this paper the mixture consists of mixing from three ECG signals, the first signal is the mother ECG (M-ECG) signal, second signal the Fetal-1 ECG (F1-ECG), and third signal is the Fetal-2 ECG (F2-ECG), these signals are extracted based on modified blind source extraction (BSE) techniques. The proposed work based on hybridization between two BSE techniques to ensure that the extracted signals separated well. The results demonstrate that the proposed work very efficiently to extract the useful ECG signals.

جهاز تخطيط القلب هو جهاز غير جراحي يستخدم لقياس الاشارات الناتجه من القلب من الضروري مراقبة قلب الاجنه التوائم خلال عملية الحمل لتشخيص كفائة القلب والكشف المبكر عن اي مشكله قبل الولاده, في حالات الحمل المتعدد تقنيه استخدام الفلاتر غير كافيه في فصل اشارات قلب الاجنه عن اشرات قلب الام , في هذا البحث مزيج اشاره القلب المتكون من ثلاث اشارات ناتجه من الجنين الاول والجنين الثاني وقلب الام استخلصت عن طريق تقنيه الفصل العمياء المعدله. حيث ان هذه التقنية تعتمد على خوارزميتن دمجت سويه للحصول على افصل عمليه فصل بين الاشارات . بينت النتائج ان العمل المقترح هو جيد وكفؤء في استخلاص اشارات القلب .

Listing 1 - 4 of 4
Sort by
Narrow your search

Resource type

article (4)


Language

English (3)


Year
From To Submit

2017 (4)