research centers


Search results: Found 8

Listing 1 - 8 of 8
Sort by

Article
THE EFFECT OF DIFFERENT CYCLE ARRANGEMENTS ON THE PERFORMANCE OF OPEN GAS TURBINE POWER PLANT

Authors: Dr. Mohamed F. Al-Dawody --- Dr. Naseer H. Hamza
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2017 Volume: 10 Issue: 1 Pages: 54-71
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

The use of gas turbine is increasing day by day for producing electricity and for various industrial applications. In this work a new approach of study for the effect of different cycle arrangements on the performance of simple gas turbine has been investigated. The new cycle arrangements include: reheat with heat exchanger, reheat with water injection, heat exchanger with water injection and reheat together with heat exchanger and water injection. All these arrangements are compared to the performance of gas turbine cycle with no modifications. A Matlab code was written to calculate the combustion characteristics and major performance parameters such as net work, fuel/air ratio, specific fuel consumption, and thermal efficiency ….etc. It’s observed that using reheat in addition to heat exchanger with water injection gives higher thermal efficiency, maximum increment was 28.6% in compare with normal basic cycle and lower fuel consumption, maximum reduction was 22.2 in compare with normal basic cycle.

في هذا البحث تم دراسة تاثير دمج التحسينات المختلفه على دوره التوربين الغازي بشكل جديد. شملت الدراسة استخدام اعادة التسخين مع المبادل الحراري, اعادة التسخين مع تقنية ضخ الماء, ومره اخرى المبادل الحراري مع ضخ الماء واخيرا المبادل الحراري واعادة التسخين مع ضخ الماء سوية. تم بناء برنامج بلغة ماتلاب لايجاد خصائص الاحتراق و العوامل المؤثره على اداء المحطة ومنها:الشغل الصافي ومعدل استهلاك الوقود والكفاءة الحرارية ....الخ. لوحظت اعلى كفاءة حرارية (28.6%) مع اقل معدل استهلاك للوقود (22.2%) عند استخدام نظام اعادة التسخين بالاضافة الى نظام المبادل الحراري مع تقنية حقن الماء بالمقارنة مع الدوره الاساسية للتوربين الغازي.


Article
Investigate the Heat Exchanger Efficiency of Hydraulic Liquid by using the Beta Test Loop

Author: Mugdad Hamid Rajab
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2017 Volume: 24 Issue: 1 Pages: 96-100
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

The aim of this paper is to determine the performance of the heat exchanger system using the hydraulic fluid . Investigation of heat exchanger system efficiency has been done versus the flow rate on the BETA test loop. This system can be used for investigation the hydraulic thermal changing. The Sequences on this system consist of a heat exchanger circuit that serves as a heat degree reducing from the primary part to the secondary part .The test method is carried out by operating the heat exchanger system with some variations of fluid flow rate in the primary part. The efficiency of system has been determined by comparing the energy value in the primary inlet to the energy value taken out form outlet by a secondary. Obtained results indicates that the increasing of fluid flow rate in the primary part from 3.86x10-4 m3 /s to 8.23x10-4 m3 /s cause a reduction in the efficiency of the heat exchanger system of about 82% to 74%.


Article
Experimental investigation of the effect of hot finnedtube position on the heat transfer coefficient

Authors: Musa M. Wais --- Murad S. Sedeeq --- Ehsan F. Abbas
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2017 Volume: 25 Issue: 2 Pages: 685-692
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In the present study, an experimental investigation is carried out to calculate heat transfer coefficient from the change in position of a finned tube in the cross-flow heat exchanger in two different conditions, which are a constant temperature at 90oC and constant heat flux at 45W/m2. A standard laboratory device (crossflow heat exchanger) was used in experiment process, that which manufactured by EDIBON company. The air flow over finned tubes inside heat exchanger was studied at Reynolds number ranging from 3600 to 11600. The comparative of experiments results between two cases shows that the Nu number in four positions at the constant temperature condition are higher than symmetrical positions in constant heat flux. The results indicated that the position3 gives higher values of Nu number in both cases

تشمل الدراسة الحالية تحليل نتائج اختبارات التي اجريت لحساب قيمة معامل انتقال الحرارة و ثاثيرها بتغير موقع انبوب مزعنف في مبادل حراري متعامد وفي حالتين من التسخين ( ثبوت درجة حرارة 90 مئوية و فيض حراري ثابت 45 واط/م2). حيث اجريت الدراسة في مدى لجريان الهواء تتراوح من 3600 الى 11600 رقم رينولد وذلك من خلال استخدام مبادل حراري مختبري نوع متعامد مجهز من قبل شركة EDIBON المتخصصة في صناعة الاجهزة المختبرية. من خلال مقارنة نتائج للحالتين، تبين بان رقم نسلت عند المواضع الاربعة في حالة ثبوت درجات الحرارة اعلى من مواضع مماثلة عندحالة ثبوت الفيض الحراري ومن مجمل النتائج الاختبارات تبين بان الموضع رقم 3 تعطي اعلى قيم لرقم نسلت للحالتين.


Article
PSO Design an Optimal Fuzzy Controller for Heat Exchanger Temperature

Author: Mohammed Abd Al-Khaliq Al-Tayyar
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2017 Volume: 25 Issue: 2 Pages: 809-817
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

The temperature in numerous chemical, industrial, heating ventilation and air conditioning HVAC applications is a very crucial variable. The temperature in these applications should be under control. This worked signs Fuzzy logic controller FLC for heat exchang system using a new technique. Heat exchang systems are used for transferring heat from a hot field to a cooler field; sotemperature control of outlet fluid is prime importance. The system of heat exchanger is always used for controlling the different temperature between outlet fluid and inlet fluid. Due to difficulty finding the parameters of the smart controller FLC, (Particle swarm optimization technique) have been projected to form the parameters of FLC. PSO is a heuristic method in computational algorithm. The contribution of our work is present PSO as a designer of FLC. The consequences demonstrate the designed controller reach to set point with the shortest time.

إن درجة الحرارة في الكثير من التطبيقات الكيميائية والصناعية فضلا عن تطبيقات تدفئة وتهوية وتبريد الهواء تعد من العوامل البالغة الأهمية وعليه فلابد من أن تكون درجة الحرارة في هذه التطبيقات مسيطر عليها. تم في هذا لبحث تصميم مسيطر ضبابي للمبادلات الحرارية. يتم إستخدام المبادلات الحرارية لنقل الحرارة من المائع الساخن إلى آخر أقل سخونة. إن السيطرة على درجة حرارة المائع الخارج من المبادل الحراري ذات أهمية قصوى. نظراً لصعوبة التعرف على المتغيرات في نظام المسيطر الضبابي، فقد تم اللجوء إلى تقنية جديدة وهي تقنية تحسين سرب الطيور. إن الإسهام الفعلي في هذا البحث هو إستخدام تقنية سرب الطيور كأسلوب تصميمي لنظام المسيطر الضبابي. يعمل المسيطر الذي تم تصميمه على تنظيم درجة حرارة المائع الخارج من المبادل الحراري ضمن القيم المحددة مسبقاً وخلال أقصر وقت ممكن وبغض النظر عن الحمل أو الإضرابات أو الإجهاد وغيرها...


Article
Study and Analysis of Concentric Shell and Double Tube Heat Exchanger Using - Al2O3 Nanofluid
الدراسات والتحاليل للمبادل الحراري ذو القشرة والانابيب المتداخلة المتمركزة باستخدام مائع نانوي كاما اوكسيد الالمنيوم

Authors: Noor Sabih Majeed نور صبيح مجيد --- Basma Abbas Abdulmajeed بسمة عباس عبد المجيد
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2017 Volume: 23 Issue: 9 Pages: 50-62
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Heat exchanger is an important device in the industry for cooling or heating process. To increase the efficiency of heat exchanger, nanofluids are used to enhance the convective heat transfer relative to the base fluid. - Al2O3/water nanofluid is used as cold stream in the shell and double concentric tube heat exchanger counter current to the hot stream basis oil. These nanoparticles were of particle size of 40 nm and it was mixed with a base fluid (water) at volume concentrations of 0.002% and 0.004%. The results showed that each of Nusselt number and overall heat transfer coefficient increased as nanofluid concentrations increased. The pressure drop of nanofluid increased slightly than the base fluid because of the low concentration used.

للمبادل الحراري اهمية في الصناعة سواء في عملية التبريد او التسخين. لزيادة كفاءة المبادل الحراري استخدم المائع النانوي لتحسين انتقال الحرارة بالحمل بالمقارنة مع السائل الاعتيادي. تم استخدام السائل النانوي المتكون من كاما اوكسيد الالمنيوم مع ماء للتبريد في المبادل الحراري ذو الغلاف والانابيب المتداخلة والمتمركزة والذي يجري باتجاه عكسي مع تيارالزيت الساخن. هذه الدقائق النانوية ذات قطر 40 نانو متر, خلطت مع الماء بتراكيز حجمية 0.002 % مع 0.004 %. اظهرت النتائج ان عدد نسلت و معامل الانتقال الحراري الكلي قد ازداد بزيادة تركيز المادة النانوية. ان فرق الضغط للسائل النانوي قد ازداد زيادة طفيفة نتيجة استخدام تركيز واطئ.


Article
Study and Analysis of Concentric Shell and Double Tube Heat Exchanger Using Tio2 Nanofluid

Authors: Bassma Abbas Abdulmajeed --- Noor Sabih Majeed
Journal: Iraqi Journal of Chemical and Petroleum Engineering المجلة العراقية للهندسة الكيمياوية وهندسة النفط ISSN: 19974884/E26180707 Year: 2017 Volume: 18 Issue: 4 Pages: 15-23
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this paper, nanofluid of TiO2/water of concentrations of 0.002% and 0.004% volume was used. This nanofluid was flowing through heat exchanger of shell and concentric double tubes with counter current flow to the hot oil. The thermal conductivity of nanofluid is enhanced with increasing concentrations of the TiO2, this increment was by 19% and 16.5% for 0.004% and 0.002% volume respectively relative to the base fluid (water). Also the heat transfer coefficient of the nanofluid is increased as Reynold's number and nanofluid concentrations increased too. The heat transfer coefficient is increased by 66% and 49% for 0.004% and 0.002% volume respectively relative to the base fluid. This study showed that the friction factor of nanofluid was decreased as Reynold's number increased.


Article
EXPERIMENTAL INVESTIGATION OF NATURAL CONVECTION HEAT TRANSFER INA HELICALED COILED PIPE
دراسة عملية لانتقال الحرارة الطبيعي في الانبوب الملتف حلزونيا

Loading...
Loading...
Abstract

The research presents an experimental investigation on the steady state natural convection heat transfer for helical coiled pipes with a vertical orientation. Water is used as the working fluid for both the target fluid and the bath medium. The heat transfer characteristics have been studied for three helical coils that having three curvature ratio (0.056, 0.0625, and 0.115) and three coil pitches (12.5, 25, and 37.5)mm with a volume flow rate of the target fluid ranges (10-25)L/min and two constant bath water temperatures (70 and 90)oC. All the experiments were performed for Rayleigh number range (1.76*109 – 1.15*1012). The experimental data have been used in SPSS software to predicted the empirical correlation of outside Nusselt number as a function of Rayleigh number by using height of the coil as a characteristic length then using this empirical relation in a computer program that have written in Fortran 90 to predict the outlet temperature and compared with the measured one. The results show that the inner and outer heat transfer coefficients increase with increasing of curvature ratio (d/D) and the mass flow rate. Also the results show that the difference between the measured and predicted outlet temperature equal to 1.5oC.

تضمن البحث دراسة تجريبية لانتقال الحرارة بالحمل الحر المستقر ولانبوب ملتف حلزونيا وموضوع بشكل عمودي. المائع المستخدم هو الماء ولكل من الانبوب الحلزوني والحوض المائي تم دراسة خواص انتقال الحرارة لثلاث انواع من الانابيب الحلزونية وبثلاث نسب انحناء 0.115,0.0625,0.056)) ولثلاث خطوات (12.5, 25, 37.5) ملم مع معدل تدفق حجمي يتراوح (10-25 ) لتر/دقيقة, ودرجات حرارة ثابته للحوض بمقدار ( 90oC, oC 70) . تم اجراء الدراسة عند مدى رقم رايلي يتراوح ( 1.76×109- 1.15×1012) تم استخدام النتائج التجريبية في برنامج احصائي من اجل ايجاد علاقة تربط بين رقم نسلت الخارجي و رقم رايلي باعتماد ارتفاع الملف كطول مميز في رقم رايلي ومن ثم استخدام تلك العلاقة في برنامج حاسوبي مكتوب بلغة فورتران 90 من اجل تنبؤ درجة حرارة الملف الخارجة . بينت النتائج ان معامل انتقال الحرارة الداخلي والخارجي يزداد مع زيادة نسبة الانحناء (d/D) وزيادة معدل التدفق واوضحت ايضا ان الفرق بين درجة حرارة الملف الخارجة المتنبئة والمقاسة هي ( 1.5 oC).


Article
EXPERIMENTAL STUDY OF HEAT TRANSFER ENHANCEMENT BY USING POROUS MEDIA IN DOUBLE TUBE HEAT EXCHANGER
دراسة عمليه لتحسين التبادل الحراري باستخدام وسط مسامي لمبادل حراري مكون من اسطوانتين متحدتي المركز

Authors: Dr. Kifah H . Hilal د.كفاح حامد هلال --- Noor Samir Lafta نور سمير لفته --- Dr.Isbeyeh W. Maid Dr. Kifah H . Hilal ** Noor Samir Lafta د.اصبيح وسمي مايد
Journal: AL-TAQANI مجلة التقني ISSN: 1818653X Year: 2017 Volume: 30 Issue: 1 Pages: E44-E59
Publisher: Foundation of technical education هيئة التعليم التقني

Loading...
Loading...
Abstract

Forced convection heat transfer in counter flow heat exchanger which uses porous media to enhance heat transfer through it, has been investigated experimentally in the present work.Theexperimental work included the design of double pipe heat exchanger with the dimension of (length 1.11m, 0.063 outer pipe diameter and 0.031m inner pipe diameter). Alumina(2.5mm diameter) as a porous media is added in heat exchangerat three case: inner porous tube (IP) , outer porous tube (OP) and inner- outer tubes (IOP) .Cold andhot water are used as working fluid to transfer heat through outer and inner pipe respectively. The experiment are conducted at hot water mass flow rates (0.0166-0.0833 Kg/s),cold water mass flow rates ( 0.05-0.116 Kg/s) ,inlet temperatures of hot water (47, 55ᵒC) andinlet temperatures of cold water(20, 25 ᵒC).The results are obtained for range of Reynolds number to hot water (1144< Re<6241) and cold water (3939البحث الحالي هو دراسة عملية لانتقال الحرارة بالحمل القسري خلال مبادل حراري مملوء بوسط مسامي لتحسين انتقال الحرارة خلاله. تضمن البحث تصميم مبادل حراري من نوع اسطوانتي متحدتي المركز بأبعاده (1.11m طول, قطر الاسطوانة الداخلية 0.031m , وقطر الاسطوانة الخارجية 0.063 m ). أستخدمت كرات من من الالومينا بقطر (2.5mm ) كوسط مسامي في المبادل الحراري بثلاثه حالات: في الاسطوانه الداخليه (IP), في الاسطوانه الخارجيه (OP), في كلا الاسطوانتين(IOP).. تم استعمال الماء البارد والحار كمائع ناقل للحرارة من جانب الاسطوانه الخارجيه والداخلية على التوالي. جرت الدراســـــــة بمعدل تدفق للماء الحـار تتراوح بين (kg/s 0.833 – 0.0166) ومعدل تدفق للماء البارد (kg/s 0.116 – 0.05)و درجه حراره الدخول للماء الحار فهي (47, 55 ᵒC) ودرجه حراره الدخول للماء البارد (25, 20 ᵒC). بينت لنتائج التي تم الحصول عليها هي ضمن رقم رينولد(1144< Re<6241) للماء الحار و(3939

Listing 1 - 8 of 8
Sort by
Narrow your search

Resource type

article (8)


Language

English (8)


Year
From To Submit

2017 (8)