research centers


Search results: Found 18

Listing 1 - 10 of 18 << page
of 2
>>
Sort by

Article
Intensification and Colour Enhancing for chest X-ray Medical Images by Matlab Program
تكثيف وتحسين اللون لصور الأشعة السينية الصدرية الطبية بتطبيق برنامج الماتلاب

Author: Kawther H. Al-khafaji
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2017 Volume: 15 Issue: 2 Pages: 259-273
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

chest X-ray images considered an important test to diagnosis a several of chest diseases, it's the most commonly requested examination in any radiology department in spite of various technological advances in the field of radiology, however explanation of chest X-ray image is a complex task is because this images is tending to noise , low contrast , blurring and unwanted information hindering the analysis of the real problems in chest human being structures, this complexities associated with X-ray images make it difficult to analyze them in an effective way. In this paper, we apply anew algorithm to enhance chest X-ray digital images and thus enhance the diagnosis of specific diseases through the application of a several operations including intensification of the basic features of the images, as well as color enhancement based on applying a number of experiment equations and change the values of the main coefficient for this equations , the medical image that has been conducting all operations onto belong to Hydatid Cysts Parasite diseases in lung . when we observed the resulting images we manifestly noting the Hydatid Cyst inside the right lobe of the lung patient in the upper part of which more clearly than is the case in the original image, and this is a good indicator of the success of the proposed algorithm to enhancing the diagnosis.

تعتبر صور الأشعة السينية الصدرية اختباراً مهما لتشخيص العديد من الأمراض الصدرية , حيث تمثل الفحص الأكثر طلبا عادة في أي قسم للأشعة على الرغم من تنوع التقدم التكنولوجي في مجال الطب الإشعاعي. غير أن شرح صورة الأشعة السينية الصدرية يعد مهمة معقدة وذلك لكون هذه الصور تميل إلى الضوضاء, انخفاض في التباين, الضبابية و احتوائها على المعلومات غير المرغوب فيها والتي تعيق تحليل المشاكل الحقيقية في بنية الصدر للانسان , هذه التعقيدات المرتبطة بصور الأشعة السينية تجعل من الصعب تحليلها بطريقة فعالة.في هذا البحث قمنا بتطبيق خوارزمية جديدة لتحسين صور الأشعة السينية الصدرية الطبية وبالتالي تحسين تشخيص أمراض محددة من خلال تطبيق العديد من العمليات بما في ذلك تكثيف السمات الأساسية للصور, وكذلك تحسين اللون بالاعتماد على كل من تطبيق عدد من المعادلات التجريبية وتغيير قيم المعاملات الرئيسية لهذه المعادلات,الصورة الطبية التي تم أجراء كافة العمليات عليها تخص مرض الأكياس المائية المتواجد في الرئة. وعند ملاحظتنا للصور الناتجة يتبن لنا بوضوح رؤية الكيس المائي داخل الفص الأيمن لرئة المريض في الجزء العلوي منها بصورة أوضح بكثير مما هو في الصورة الأصلية, و يعد هذا مؤشرا جيدا لنجاح الخوارزمية المقترحة في تحسين التشخيص .


Article
Characterization of Ag:Ni Nano Particles Produced by Pulse Nd:YAG laser
تشخيص دقائق Ag:Ni النانوية المنتجة بواسطة ليزر النيوديميوم-ياك النبضي

Author: Ahmed Abd Al-Razza Naama أحمد عبد الرزاق نعمة
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2017 Volume: 58 Issue: 2A Pages: 653-662
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This work presents the characteristics of plasma produced by fundamental wavelength (1064 nm) Q- switched Nd:YAG laser on Ag:Ni alloy in distilled water were investigated at different laser energies by optical emission spectroscopy technique. The size of produced nanoparticles from Ag:Ni target in distilled water were studied, by x-ray diffraction, UV-visible absorbance and atomic force microscopy, at different laser energies. Spectroscopic measurements show that electron temperature and electron density increase with increasing laser energy. It was found from AFM measurements that the produced nanoparticle size decrease from 97.13 nm to 71.20 nm, while XRD shows that the crestalline size decrease from 15.5 nm to 9 nm with increasing pulse laser energy. UV- visible absorbance shows at plasmon peaks shifted from 410 to 395 nm with increasing laser energy.

هذا البحث هو دراسة لخصائص البلازما المنتجة عن طريق الليزر النبضي ذو محول عامل النوعية نيوديوم ياك (Nd:YAG) من سبيكة Ag:Ni في الماء المقطر عند طاقات مختلفة لليزر بواسطة تقنية التحليل الطيفي للانبعاثات. تم دراسة تأثير الطاقات المختلفة لليزر على الحجم االنانوي للدقائق المنتجة من هدف Ag:Ni في الماء المقطر باستخدام حيود الاشعة السينية و امتصاص الاشعة المرئية فوق البنفسجية ومجهر القوى الجزيئية. تبين من القياسات AFM أن حجم الجسيمات النانوية ينخفض من 97.13 إلى 71.20 نانومتر ، بينما أظهرت قياسات XRD انخفاض الحجم البلوري من 15.5 نانومتر إلى 9 نانومتر مع زيادة طاقة الليزر النبضي. يظهر طيف امتصاص الأشعة فوق البنفسجية- مرئية قمة البلازمون تزحزحت 410-395 نانومتر مع زيادة طاقة الليزر.


Article
Effect of annealing and chemical treatment on structural and optical properties of CuPcTs/PEDOT:PSS (BHJ Blend) thin films
تأثير التلدين و المعاملة الكيميائية على الخصائص التركيبية والبصرية للاغشية CuPcTs/PEDOT:PSS الرقيقة

Authors: Mahdi H. Suhail مهدي حسن سهيل --- Amer A. Ramadhan عامر عباس رمضان
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2017 Volume: 15 Issue: 33 Pages: 131-142
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this work, The effect of annealing treatment at different temperatures (373, 423 and 473)K and chemical treatment with talwen at different immersion time (40, 60 and 80) min on structural and optical properties of the bulk heterojunction (BHJ) blend copper phthalocyaninetetrasulfonic acid tetrasodium salt/poly dioxyethylenethienylene doped with polystyrenesulphonic acid (CuPcTs/PEDOT:PSS) thin films were investigated.The films were fabricated using spin coating technique. X-ray diffraction (XRD) measurements displayed only one peak at 2θ =4.5o corresponding to (001) direction which has dhkllargerthan for standard CuPcTs. The dhkl increase then decrease with increasing annealing temperature andthe time of chemical treatment with talwen. FTIR measurementsshow that, the peaks for O-H, in general, decrease with increasing annealing temperature, while the peaks corresponding to C=C aromatic bond and C-N bond decrease at 373 K then increase at 423 and 473 K. The peaks for O-H, in general, decrease with increasing immersing time,while the peaks corresponding to C=C aromatic bond and C-N bond decrease at 40 min then increase at more immersing time.From UV-visible measurements, the absorption spectra peaks for B and Q-bands increase at 373K and at 40 min immersing time with talwen and decrease at more annealing or chemical treated time.

تم في هذا البحث دراسة تأثير التلدين ولدرجات حرارة مختلفة(373 و 423 و473) كلفن و المعاملة الكيميائية باستخدام مادة التلوين وبأزمان غمر مختلف (40 و60 و80 ) دقيقة على الخصائص التركيبية والبصرية لغشاء مزيج ملح نحاس–فثالوسيانين الرباعي ملح الصوديوم مع مادة حامض كبريتات البوليستيرين(CuPcTs/PEDOT:PSS) المحضر بطريقة الطلاء الدوراني. ظهر في دراسة حيود الاشعة السينية قمة واحدة بحدود 4.5 درجة والتي تخص الاتجاه (001) والتي تمتلك قيم اصغر للمسافة البينية للمستويات البلورية (dhkl)مما في قيم CuPcTs القياسية. قيم الdhklتزداد ثم تقل مع زيادة درجة الحرارة و تقل مع زيادة زمن المعاملة الكيميائية مع التلوين. بينت قياسات مطياف تحويل فورير للأشعة تحت الحمراء أن القمم التي تخص O-H بصورة عامة تقل شدتها بزيادة درجة حرارة التلدين. بينما القمم التي تخص كل من الاواصرC=C الاروماتية و الاواصر C-N تقل عند 373 كلفن ومن ثم تزداد عند 423 و473 كلفن. القمم التي تخص O-H بصورة عامة تقل شدتها بزيادة زمن العاملة الكيميائية. بينما القمم التي تخص كل من الاواصرC=C الاروماتية و الاواصر C-N تقل عند 40 دقيقة ثم تزداد لزمن معاملة اكثر مع التلوين. من قياسات طيف الامتصاص للأشعة فوق البنفسجية- مرئية، أن قمم امتصاص الحزمة B و Q تزداد عند درجة حرارة تلدين373 كلفن وعند 40 دقيقةزمن غمر بمادة التلوين ثم تنخفض عند تلدين او زمن معاملة أكثر.


Article
Study of alumina prepared from Iraqi kaolin
دراسة الالومينا المحضرة من الكاؤلين العراقي

Authors: Dhuha M. Oudah Al-Sumaidaie ضحى مهدي عودة --- Jassim M. Salih جاسم محمد صالح --- Ayoub S. Karim ايوب صابر كريم
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2017 Volume: 15 Issue: 34 Pages: 148-152
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The current research was conducted to report the synthesis of alumina powder from Iraqi kaolin. The kaolin was transformed to metakaolin by calcinations at temperature 800 °C for three hours. Then the calcined kaolin was treated with (1.5 M) from H2SO4 for 6 hours to form Al2(SO4)3.12H2O solution. The precipitate was dried at 80oC for 10 hours and calcinations at different temperatures for two hours. The samples which result was characterized by X–Ray diffraction (XRD) and X–Ray fluorescence (XRF). The results indicate to the crystalline hydrate aluminum sulfate for the sample that be as – synthesis and when calcinations at 600 oC transformed into aluminum sulfate phase. The phases of alumina which we obtain consisted of a gamma alumina phase which getting at calcinations 1000 oC and an alpha alumina phase at calcinations 1300 oC. The optimum conditions for preparation alumina from Iraqi kaolin is at reaction time 6 hours, particle size 75μm and concentration acid is (1.5 M) where was the highest percentage of extraction alumina is 98.8%. The effect of calcinations temperature on the rate of extracted alumina was studying in this research and found that the alumina ratio was extracted increasing with increase the calcinations temperature.

تهدف الدراسة الحالية إلى عملية تحضير مسحوق الالومينا من اطيان الكاؤلين العراقي. تم تحويل الكاؤلين الى ميتا كـاؤلين بواسـطة التحميص عند 800 oC لمدة 3 ساعات. تم معالجة الكاؤلين المكلسن بحامض الكبريتيك في تركيز 1.5 M لمدة 6 ساعات للحصول على محلول كبريتات الالمنيوم المائية. تم تجفيف الراسب عند 80 oC لمدة 10 ساعات ومن ثم تحميصه عند درجات حرارة مختلفة لمدة ساعتين. تم تشخيص العينات الناتجة بواسطة انحراف الاشعة السينية و تقنية تألق الاشعة السنية، حيث تشير النتائج الى بلورة كبريتات الالمنيوم المائية للعينة المحضرة وعند التحميص الى 600 oC تتحول الى طور كبريتات الالمنيوم. ان مراحل الالومينا التي نحصل عليها تشمل طور كاما الومينا عند التحميص الى 1000 oC و طور الفا الومينا عند التحميص الى 1300 oC.الظروف المثلى لتحضير الالومينا من الكاؤلين العراقي هي عند زمن تفاعل 6 ساعات وحجم حبيبي 75 μm وتركيز حامض 1.5 M حيث كانت اعلى نسبة استخلاص للالومينا هي98.8 % . في هذا البحث تم دراسة تأثير درجة حرارة التحميص على نسبة استخلاص الالومينا وقد وجد ان نسبة الاستخلاص تزداد بزيادة درجة حرارة التحميص.


Article
Aggregation and Characterization of ZnO Nano Particles Using Laser Ablation Technique in Ethanol

Authors: Wisam J. Aziz --- M.A.Abid --- Hanan Kh. Mutlk
Journal: Al-Nahrain Journal of Science مجلة النهرين للعلوم ISSN: (print)26635453,(online)26635461 Year: 2017 Volume: 20 Issue: 4 Pages: 32-39
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

In this work, ZnO nanoparticles were snthyesis using pulse laser ablation of zinc target (purity of 99.99%) immersed in ethanol with wave length of Nd:YAG laser (532 nm) operating at different laser energies (700, 800, 900 mJ) with 1Hz and (2000) pulse. A matching of the observed and standard (hkl) planes confirmed that the product is ZnO having a polycrystalline in nature with hexgonal structure perferention in (101) direction.FESEM images showed that NPs have different morphologies and not uniform consist of many small irregular nanoparticles. The surface structure, in the energy 700 mJ has been more uniform compared with others energy.


Article
VALUE OF PLAIN ABDOMINAL RADIOGRAPH, ULTRASOUND AND COMPUTERIZED TOMOGRAPHY IN THE DIAGNOSIS OF INTESTINAL OBSTRUCTION

Author: Nawfal K. Salih نوفل كامل صالح
Journal: IRAQI JOURNAL OF MEDICAL SCIENCES المجلة العراقية للعلوم الطبية ISSN: P16816579,E22244719 Year: 2017 Volume: 15 Issue: 3 Pages: 227-233
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

Background: The diagnosis of mechanical intestinal obstruction is sometimes very challenging especially in the absence of previous abdominal surgery or obstructed hernia and there are limited studies comparing or evaluating the usefulness of plain abdominal x-ray, ultrasonography, and computerized tomography (CT) in intestinal obstruction.Objective: To compare the efficacy of plain abdominal x-ray, ultrasound and CT in the diagnosis of intestinal obstruction. Also, to assess ultrasound value and usefulness in pregnant women and critically bed ridden patients with intestinal obstruction.Methods: In this prospective study with signs and symptoms of mechanical intestinal obstruction, a total of sixty two patients were investigated by plain x-ray, ultrasound, CT scan and the findings were compared with reference to the presence or absence of obstruction, the level, site, cause and strangulation of bowel for a period of eight years (2009-2016). The final diagnosis was obtained by surgery and only those with proved intestinal obstruction per-operative were included in the study.Results: Out of the sixty two patients (41 males and 21 females) included with an age incidence (22-65 yr), 58 had mechanical intestinal obstruction (50 had small bowel obstruction and 8 had large bowel obstruction), of the remaining 4 patients; 2 had mesenteric vascular occlusion and 2 had pseudo-obstruction. The level and site of obstruction was correctly predicted in 91.9% on CT, in 82% on ultrasound and 90.3% on plain film. CT was the best 85.4% to both, ultrasound 24% and plain film 8% in determining the cause of obstruction. Regarding strangulation of bowel, CT was superior while plain film was the least informative with the ultrasound in between.Conclusion: CT is the best tool for the diagnosis, strangulation of the bowel and detecting cause of intestinal obstruction and recommended to be the investigation of choice in equivocal cases. Ultrasound is the best and sole investigation in pregnant women and critically bed ridden patients especially in early cases.Keywords: Intestinal obstruction, plain abdominal x-ray, ultrasound, CT scan.Citation: Salih NK. Value of plain abdominal radiograph, ultrasound and computerized tomography in the diagnosis of intestinal obstruction. Iraqi JMS. 2017; Vol. 15(3): 227-233. doi: 10.22578/IJMS.15.3.3


Article
Effect of Deposition Temperature on Optical and Crystallographic Properties of CsI Thick Films Deposited using Spray Pyrolysis

Author: J.H. Khulaef
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2017 Volume: 35 Issue: 2 Part (B) Scientific Pages: 195-203
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

A deposited layer of CsI has been prepared at different substratetemperatures using spray pyrolysis technique. The X Ray diffraction of CsIfilms reveals special pattern peaks (110), (200), (211), (220), (310) and (321).From transmission spectra we calculated the energy gap of CsI films whichincrease with increasing deposition temperature for direct transition isestimated.


Article
Study the Effect of Electrodeposition Parameters on Ni/SiC Composite Coating

Authors: Fatima N. Jaseem --- Mofeed A.L. Jaleel
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2017 Volume: 20 Issue: 4 Pages: 1005-1011
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

In this research, we successfully obtained Ni/SiC micro-composite coatings with various contents of SiC particles of particle size(10 µm), by using electrodeposition method from nickel watts bath in which the SiC particles suspend. The effects of the current density, temperature, and particle loading(PL) of SiC particles in the electrolyte on the morphology, texture, and vol% of SiC in deposit were investigated. The morphological and structural analysis show uniform distribution of SiC particles within the composite coatings. It was found that the depositing conditions affect the microstructure of deposited nickel and the SiC vol% in deposit. Furthermore, the vol% of SiC increases in deposit by increasing the particle loading(PL) in the bath, while decreased by increasing the current density. Also the higher values of SiC vol% were obtained at temperature (50°C).

في هذا البحث تم تحضير الطلاء المتراكبة Ni/SiC بنسب مختلفة من دقائق كاربيد السيليكون داخل حمام الطلاء ذات الحجم الحبيبي (10 µm) بأستخدام طريقة الترسيب الكهربائي وباستخدام حمام واتس الذي تتشتت داخله دقائق SiC. حيث تمت دراسة تأثير كل من كثافة التيار, درجة حرارة حمام الطلاء, وتركيز الدقائق داخل حمام الطلاء على كل من مورفولوجيا السطح, التركيب, والنسبة الحجمية للدقائق داخل الطلاء. ان التحليل التركيبي للطلاء اظهر التوزيع المتجانس للدقائق داخل الطلاء. ووجد بأن شروط الترسيب لها تأثير على التركيب المايكروي لطلاء المتراكبات وكذلك على النسبة الحجمية للدقائق داخل الطلاء. علاوة على ذلك, فأن النسبة الحجمية للدقائق داخل الطلاء تزداد بزيادة تركيز الدقائق في حمام الطلاء, بينما تقل بزيادة كثافة تيار الترسيب. كما ان اعلى قيمة لااندماج الدقائق كانت عند درجة حرارة 50 OC.


Article
Effect of Retained Austenite on the Micro-structure and Mechanical Properties of AI-SI4340 High Strength Low Alloy Steel (HSLA steel) Using Magnetic Saturation Measurement and X-Ray Diffraction methods

Authors: Nagham. M Abdulkareem نغم عبدالكريم --- Murtadha A. Jabbar مرتضى جبار
Journal: Basrah Journal for Engineering Science مجلة البصرة للعلوم الهندسية ISSN: Print: 18146120; Online: 23118385 Year: 2017 Volume: 17 Issue: 2 Pages: 1-8
Publisher: Basrah University جامعة البصرة

Loading...
Loading...
Abstract

Retained Austenite (RA) has great deal with the mechanical properties of high strength low alloy steel. Therefore,in this paper, Retained Austenite volume fractions have beenevaluated in AISI4340 alloy steel using two well-known methods, X-Ray diffraction (XRD) and magnetic measurementmethods. The specimens were heat treated using different heating temperature and different cooling rate (different quenchingmedia). A comparison between the results of two methodsproved that there results were approximately Identical .Theresults show that Retained Austenite formation increase asheating (Austenizing ) temperature increase for the samequenching media ,as well as ,it increases by increasing coolingrate . The maximum amount of Retained Austenite found as(27.2 Wt %) which recognized when the specimens heated upto 1000˚C then quenched in Water while the minimum amountof Retained Austenite found as ( 7.06 wt%) when the specimensheated up to ( 800 ˚C) then quenched in Sand. Hardness testsusing Vickers and Rockwell methods were used and the resultsshow that hardness values decreased with increasing heatingtemperatures and the maximum Vickers micro-hardness andRockwell hardness numbers were equal to (121.8HRB) and (516.35 HV) which were detected when heating up of the specimens were up to 800 ˚C then quenched in water. Tensile testsshow that increasing cooling rate lead to increasing in Strengthdue to increasing of hardness which in turn, leads to increasein yielding points and ultimate strengths. Retained austeniteeffects on microstructure were investigated using scanningelectron microscopy (SEM) and optical microscopy and theresults show that at low cooling rate the microstructure consistof bainite and/or martensite phase with small amount of retained austenite, while, increasing heating temperature andcooling rate results in microstructure consist of martensite andretained austenite phases.


Article
Effect of low level nozzle height on properties of copper oxide absorption layer prepared by fully computerized spray pyrolysis depositions
تأثير اقتراب مستوي ارتفاع الفوهة على خصائص طبقة الامتصاص من اوكسيد النحاس المحضرة بواسطة منظومة الترسيب بالرش الحراري المتكاملة والمحوسبة

Authors: Mohammed S. Essa محمد شعلان عيسى --- Baha T. Chiad بهاء طعمة جياد
Journal: Iraqi Journal of Physics المجلة العراقية للفيزياء ISSN: 20704003 Year: 2017 Volume: 15 Issue: 32 Pages: 13-20
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The effect of approaching nozzle jet from the deposition surface on structural, optical and morphology properties of copper oxide thin films was studied. The film was prepared by homemade fully computerized CNC spray pyrolysis deposition technique at preparations speed(3,4,5,and 6mm/sec). The repeated line mode was used at deposition temperature equal 450 °C whereas the spraying time was in the range of (15-30 min) according to the deposition speed. The film exhibit polycrystalline structure with preferred orientation along (-111), (022) and (011), (002) at a 2θ value of (35.63o) and (38.8o) respectively. Optical band gaps were recorded at these speed shows variance in value from (1.53-2.08 eV). Films thickness were found to be in the range (128-412 nm) which depends on preparation speed.

تم دراسة تأثير قرب المسافة بين جهار التذرية من سطح الترسيب على الخصائص التركيبية، والبصرية، والتجانس لأغشية أوكسيد النحاس. تم تحضير الاغشية بواسطة منظومة الرش الكيميائي الحراري المتكاملة والمحوسبة بواسطة السيطرة العددية للكومبيوتر المصنعة محليا عند سرع تحضير (3، 4، 5و 6) ملم/ثا. استخدم نمط الطلاء المتكرر عند درجة حرارة التحضير 450 درجه مئوية حيث كان زمن الرش في المدى (15-30) دقيقه تبعا لسرعة الترسيب المستخدمة.الأغشية أظهرت تركيب بلوري متعدد عند اتجاهات مميزه كانت ((-111، (022) و(011)، (002) عند القيمة زاوية (35,63) و (38,8) تباعا. سجلت قيمة فجوة الطاقة البصرية عند سرع الترسيب المستخدمة وكانت قيمها بداء من (.531-2.08). سمك الأغشية وجدت في المدى (128-412) نانومتر اعتمادا على سرع الترسيب المستخدمة.

Listing 1 - 10 of 18 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (18)


Language

English (18)


Year
From To Submit

2017 (18)