research centers


Search results: Found 2

Listing 1 - 2 of 2
Sort by

Article
Production of Structural Light-Weight Aggregate Concrete Using Different Types of Iraqi Local Crushed Materials as Coarse Aggregate

Authors: Wissam Nadir Najim --- Maryam Hameed Naser Al-Mamoori --- Fatimah Hameed Naser Al-Mamoori
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 1 Pages: 375-362
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

Structural Lightweight Concrete (SLWC), Porcelanite Rocks, Pumice Stone, Clay Brick, Thermestone, Non-destrictive Tests

تقدم هذه الدراسة التحري العملي لإنتاج خرسانة انشائية خفيفة الوزن باستخدام ثلاثة أنواع من الركام الخفيف الذي يمكن الحصول عليه من مصادر مختلفة من المواد الطبيعية والنفايات والمواد المعاد تدويرها في العراق ومقارنتها بالخرسانة الاعتيادية المصنوعة من الركام الطبيعي (الحصى).استخدمت في هذه الدراسة صخور البورسلانيت الطبيعية المتوفرة في الصحراء الغربية في العراق كركام خشن في الخلطة الاولى. أما الخلطة الثانية فتحتوي على حجر الخفاف الذي يمكن الحصول عليه من شمال العراق. الخلطة الثالثة للخرسانة الانشائية خفيفة الوزن انتجت باستخدام مزيج من الركام الخشن الذي يتكون من 75٪ من الطابوق الطيني العراقي المحلي المعاد تدويره و 25٪ من نفايات الثرمستون. كل هذه الخلطات قورنت مع الخرسانة الاعتيادية المصنوعة باستخدام الركام الطبيعي (الحصى) باستخدام نفس النسب لمكونات الخلطة الخرسانية والتي تضمنت استخدام المضافات المعدنية والكيميائية.في هذا البحث، تم دراسة خصائص الخرسانة في الحالتين الطرية والصلبة. وفي الحالة الصلبة للخرسانة تم اجراء الفحوصات الاتلافية واللااتلافية بعمر 28 يوم.من نتائج هذه الدراسة, يمكن الاستنتاج بإمكانية انتاج خرسانة خفيفة الوزن انشائية بكثافة جافة اقل من 2000 كغم/م3 واقل مما يقابلها من استخدام الركام الطبيعي بنسبة تتراوح بين (25% - 27.4% ) وبمقاومة انضغاط للأسطوانة تتراوح بين (25.3-36.1) ميكا باسكال بعمر 28 يوما باستخدام صخور البورسلينايت, حجر الخفاف ومزيج من كسر الثرمستون والطابوق الطيني المحلي المعاد تدويره كركام خشن خفيف الوزن.في هذه الدراسة تم اقتراح العديد من العلاقات لإيجاد بعض الخواص الميكانيكية للخرسانة خفيفة الوزن الانشائية. كما تمت مقارنة النتائج المختبرية والعلاقات المقترحة مع معادلات معهد الخرسانة الامريكي ACI318, 2014 وبعض الدراسات والبحوث السابقة.


Article
STUDYING THE EFFECT OF LATERAL REINFORCEMENT ON CIRCULAR SHORT COLUMNS BEHAVIOR WITH/WITHOUT STEEL FIBERS
دراسة تأثير التسليح الجانبي على سلوك الاعمدة الخرسانية القصيرة مع وبدون تسليح الياف الحديدAli Hameed Naser Al-Mamoori

Authors: Ali Hameed Naser Al-Mamoori --- Fatimah Hameed Naser Al-Mamoori --- Maryam Hameed Naser Al-Mamoori
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2018 Volume: 16 Issue: 1 Pages: 232-249
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

In the present research, experimental study has been devoted to investigate the behavior of sixteen circular reinforced concrete short columns which have different lateral reinforcement and amount of steel fiber and they were tested under concentric compression till failure in order to discover the best confining column system and optimum steel fiber ratio. These columns are categorized into four groups; each group has four specimens, the first specimen without steel fiber and other specimens containing steel fiber with different ratio (0.5%, 0.75% and 1.0%).All specimens have the same geometry and longitudinal reinforcement but differ, in the type of lateral reinforcement divided in three groups (no lateral reinforcement, tied lateral reinforcement and spiral lateral reinforcement; the spiral and tied reinforcement have approximately the same amount of reinforcement.) Also, these specimens compared with no longitudinal and no laterals reinforcement (plain concrete columns) as control specimens in the first group.In this study, a crushed recycled concrete was used as a coarse aggregate combinations with natural aggregate (25% replacement of natural aggregate by a crushed recycled concrete) to produce concrete without any chemical and mineral additions.The experimental results indicated that the use of steel fiber in columns caused increase rate in ultimate load are higher than normal concrete column but at certain limit less or equal 0.75%. The combined effect of steel fibers and tied stirrups resulted in increasing the ultimate load in columns by about (7.39% - 23.34%) with respect to the same columns without lateral reinforced. While it's shown that the columns with steel fibers and spiral stirrups resulted in increasing the ultimate load by about (15.06% - 25.56%) with respect to the same columns without lateral reinforced. Also, it was observed that the behavior of spiral lateral reinforced concrete columns with or without steel fibers gives the best result when compared with other cases.

تتضمن الدراسة الحالية التحري العملي لسلوك ستة عشر نموذج من الاعمدة الخرسانية المسلحة القصيرة الدائرية المقطع الحاوية على نوعين من التسليح الجانبي (تسليح الحصر) ونسب مختلفة من الالياف الفولاذية تحت تأثير حمل مركز عند مركز العمود حتى الفشل من اجل الوصول لأفضل نظام حصر وللوصول للنسبة المثلى لألياف الفولاذ المضافة. وتصنف هذه الأعمدة إلى أربع مجموعات؛ كل مجموعة تحتوي على 4 نماذج ، النموذج الاول بدون الياف فولاذية وبقية النماذج تحتوي على نسب مختلفة من الالياف الفولاذية (0.5, 0.75, 1.0) %.جميع النماذج لها نفس الابعاد والتسليح الطولي ولكنها تختلف، في نوع التسليح الجانبي مقسمة إلى ثلاث مجموعات (بدون تسليح جانبي ، التعزيز الجانبي المقيد، تسليح جانبي مقيد (حلقي) وتسليح جانبي حلزوني لهما تقريبا نفس الكمية من التسليح.) هذه النماذج يتم مقارنتها ايضا مع نماذج من الاعمدة الخرسانية التي لا تحتوي على تسليح طولي او جانبي (عينات السيطرة او العينات المرجعية) في المجموعة الأولى.في هذه الدراسة، تم استخدام الخرسانة المعاد تدويرها كركام خشن مع الركام الطبيعي (بنسبة استبدال مقدارها 25٪ من الركام الطبيعي باستخدام الخرسانة المعاد تدويرها كركام خشن) لإنتاج خرسانة دون أي إضافات كيميائية ومعدنية.بينت النتائج أن استخدام الألياف الفولاذية في الأعمدة أدى إلى زيادة معدل الحمل النهائي أعلى من عمود الخرسانة العادي ولكن عند حد معين أقل أو يساوي 0.75٪.وأدى التأثير المشترك للألياف الفولاذية والتسليح الجانبي الحلقي إلى زيادة الحمل النهائي في الأعمدة بنحو (7.39٪ - 23.34٪) عند المقارنة بنفس الأعمدة دون تسليح جانبي. في حين تبين أن الأعمدة ذات الألياف الفولاذية والتسليح الجانبي الحلزوني أدى إلى زيادة الحمل النهائي بنحو (15.06٪ - 25.56٪) عند المقارنة بنفس الأعمدة دون تسليح جانبيكما لوحظ أن سلوك أعمدة الخرسانة المسلحة بالتسليح الجانبي الحلزوني مع الألياف الفولاذية أو بدونها يعطي أفضل النتائج عند مقارنتها مع الحالات الأخرى.

Keywords

Listing 1 - 2 of 2
Sort by
Narrow your search

Resource type

article (2)


Language

Arabic (1)

English (1)


Year
From To Submit

2018 (2)