Article
Experimental Investigation of Short Square Normal and Hybrid Fiber Reactive Powder Concrete Columns Subjected to Chloride Solution Attack
التصرف العملي للأعمدة الخرسانية القصيرة مربعة المقطع ذات الخرسانة العادية والمساحيق الفعاله المسلحة بالياف هجينة والمعرضة لهجوم محلول الكلورايد

Authors: Mohammed Mosleh Salman محمد مصلح سلمان --- . Husain Khalaf Jarallah حسين خلف جارالله --- Raed Satar Al-Behadili رائد ستار البهادلي
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2018 Volume: 24 Issue: 7 Pages: 75-94
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

In this research, the structural behavior of reinforced concrete columns made of normal and hybrid reactive powder concrete (hybrid by steel and polypropylene fibers) subjected to chloride salts with concentration was 8341.6 mg/l. The study consists of two parts, the first one is experimental study and the second one is theoretical analysis. Three main variables were adopted in the experimental program; concrete type, curing type and loading arrangement. Twenty (120x120x1200) mm columns were cast and tested depending on these variables. The samples were reinforced using two different bars; Ø8 for ties and Ø12 with minimum longitudinal reinforcement (0.01Ag). The specimens were divided into two main groups based on curing type: The first group consists of casting and testing of ten columns that cured in tap water for 28 days with two types of concrete (normal and hybrid), five columns for each type. While the second group consists of ten columns that direct cured and fully immersed in chloride water (8341.6 mg/l) 6 months with two types of concrete (normal and hybrid), five columns for each type. The specimens were tested under three types of loading, the first one is axial load, the second one is eccentric load with three different eccentricities (50,100 and 150) mm and where (e/h) are (0.42, 0.83 and 1.25) respectively from the center of column while the third type of loading is tested the specimens as beam.The experimental results showed an increase in ultimate load capacity and higher chlorides resisting for hybrid reactive powder concrete in comparison with normal concrete in both types of curing (tap and chloride water) through studying strain profile. Interaction diagram charts were obtained from different types of loading for each specimen. These charts showed high values for hybrid reactive powder concrete in comparison with normal concrete.

في هذا البحث تم دراسة التصرف الانشائي للاعمدة الخرسانية والمعرضة للاملاح الكلوريدية و (بتركيز 8341.6 ملغملتر) في نوعين من الخرسانة العادية وذات المساحيق الفعاله والمهجنة بالالياف ((steel and polypropylene fibers. تم اجراء ( جانبين في البحث الاول الجانب العملي والثاني الجانب النظري. يتضمن الجانب العملي ثلاث متغيرات هي نوع الخرسانة ونوع المعالجة ونوع التحميل, حيث تم صب وفحص 20 عمود خرساني بابعاد (120 × 120) ملم وبارتفاع 1200 ملم واستخدام نوعين من الاقطار لحديد التسليح Ø8 للاطواق المقاومة للقص و Ø12 التسليح الطولي وبنسبة 1%, تم تجزئة الجانب العملي الى جزئين: الجزء الاول وهو صب 10 اعمدة ومعالجتها في المياه العادية لمدة 28 يوم بنوعين من الخرسانة العادية والمهجنة 5 اعمدة لكل نوع خرسانة اما الجزء الثاني هو صب 10 اعمدة ومعالجتها بالمياه الكلوريدية و (بتركيز 8341.6 ملغملتر) وغمرها كليا لمدة 6 اشهر وايضا بنوعين من الخرسانة ولكل نوع 5 اعمدة.في الفحص تم تسليط ثلاث انواع من الحمل وهي الحمل المحوري واللامحوري وهي (50, 100, 150) ملم ونسبة ( (e/h0.42 , 0.83 و 1.25 ) من سنتر العمود والحمل الاخير هو فحص النموذج كعتبة.اظهرت النتائج العملية زيادة في الحمل والمقاومة في كلا المعالجة العادية والكلوريدية للخرسانة المهجنة مقارنة بالخرسانة العادية من خلال الحصول على interaction diagram chart, strain profile من خلال اختلاف نوع الحمل لكل نموذج حيث اظهرت النتائج الارقام العالية لرسم ال chart للخرسانة المهجنة مقارنة بالعادية.


Article
STRUCTURAL BEHAVIOR OF REACTIVE POWDER CONCRETE VOIDED CYLINDRICAL SHELL SEGMENTS

Authors: Ashraf Abdulhadi Alfeehan --- Fatima Ismail Al-Zubaidi
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2018 Volume: 22 Issue: 2 (Part-5) Pages: 30-40
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Voided cylindrical shell is a sustainable reinforced concrete roof system. Two directions of the voids system with two types of the voids shape in each direction had been used in this experimental work. Circular and squared void shapes used as continuous voids in the uniaxial direction while spherical and cubic void shapes used as separate voids in the biaxial direction. The diameter of the circular or spherical void is (70mm) and an equivalent side length of about (62.5mm) was used for the squared or cubic voids. The experimental variables were included the type of the shell, direction of the voids, shape of the voids and a number of the steel reinforcing layers (bottom or top and bottom) . The cylindrical shells tested as simply supported under one-point load at the crown of the shell. By (37%) maximum reduction in the concrete volume, the ultimate load capacity decreased by (35%). As well as, use of the voids in the biaxial direction improved the structural behavior in comparison with the use of voids in the uniaxial direction as a hollow core section. The use of square section or cubic void shape gave a better structural performance than the use of circular section or spherical void shape in both directions.


Article
EFFECT OF STEEL FIBERS RATIO ON THE STRUCTURAL BEHAVIOR OF DOMES
تأثير نسبة الألياف الفولاذية على السلوك الهيكلي للقباب

Authors: Mohammed Mohammed Rasheed --- Layth Abdulbari Al-Jaberi --- Nadiyah Kherallah Abd
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2018 Volume: 22 Issue: 5 Pages: 118-129
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

The main objective of the current paper is to investigate the effects of the ratio of steel fibers on structural behavior of reinforced concrete hemispherical domes. Three reinforced concrete domes were experimentally implemented, two of them made fully of reactive powder concrete and the last one made of ferrocement concrete. All specimens have 800 mm diameter, 400 mm height and 20 mm thickness, and they reinforced with welded wire meshes. The experimental program included casting and testing the domes, by applied a single point load at the center of dome, until the failure is happened. The first cracking load, ultimate load, load deflection curves, and crack pattern for all tested domes were included in this study. In general, the effects of concrete type and the ratio of steel fiber are obviously important on the behavior and ultimate strength of the domes.


Article
STRUCTURAL BEHAVIOR OF THIN RPC WALL PANELS WITH VARYING STEEL REINFORCEMENT AND ASPECT RATIO SUBJECTED TO AXIAL ECCENTRIC UNIFORMLY DISTRIBUTED LOADING

Authors: Saad Khalaf Mohaisen --- Layth Abdulbari Al-Jaberi --- Aya Haqi Ismael
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2018 Volume: 22 Issue: 4 Pages: 25-38
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

This paper presents experimental study of structural behavior of thin Reactive Powder Concrete (RPC) wall panels subjected to axial eccentric uniformly distributed loading with varying steel reinforcement ratio (ρ) and aspect ratio (AR= H/L). The experimental program included testing of six two-way thin RPC wall panels, fixed at all sides and applying the load axially with eccentricity equal to (t/6). The results indicates that the ultimate strength of the RPC wall panel decreases with increase in AR from (1.25 to 2.00) for panels with H/t = 18.75. The decreasing in ultimate load for RPC wall panels is about 16% and 38.7%, for an increase in AR from 1.25 to 2.0 for panels with ρ = 0.012566, and about 6.38% and 36.2%, for an increase in AR from 1.25 to 2.0 for panels with ρ = 0.007854.The ultimate strength of RPC wall panel increases with an increase of percentage of steel reinforcement ratio (ρ). For an increase in reinforcement ratio from ρ = 0.007854 to ρ = 0.012566 the increase is about (6.4, 4.76 and 2.22) % for walls with AR (1.25, 1.50 and 2.00) respectively. The lateral deflection decrease with the increase of percentage of steel reinforcement ratio from (0.007854 to 0.012566) under two-way in plane loading, When AR= 1.25 the reduction about (1.22 times) and When AR= 2.00 the reduction about (1.11 times). The lateral deflection of RPC wall panels decrease with the increase in aspect ratio.


Article
Behavior of Hybrid Reactive Powder Concrete Columns Exposed to Chloride Attack
تصرف الاعمدة ذات الخرسانة الفعاله المهجنة المعرضة لهجوم الكلورايد

Authors: Mohammed M. Salman محمد مصلح سلمان --- Husain K. Jarallah حسين خلف جارالله --- Raed Satar Al-Behadili رائد ستار ورور
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2018 Volume: 21 Issue: 3 Pages: 327-343
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

In this paper, the cross section behavior of reinforced concrete columns made of normal and hybrid reactive powder concrete (hybrid by steel and polypropylene fibers) under concentric and eccentric vertical load was study. The casted columns were cured in two different type tap water for 28 days and chloride water for six months. Chloride salts with concentration was 8341.6 mg/l. Three variables were adopted in the experimental program; concrete type, curing type and the eccentricity of vertical load. Twenty (120x120x1200) mm columns were casted and tested depending on these variables. The different eccentricities were (0, 50,100 and 150) mm and where (e/h) were (0, 0.42, 0.83 and 1.25) respectively from the center of column, the other types of loading are tested the specimens as beam.The experimental results showed increasing in ultimate load capacity and higher chlorides resisting for hybrid reactive powder concrete in comparison with normal concrete in both types of curing (tap and chloride water). Through studying load deflection, test results for Normal Strength Concrete (NSC) and Hybrid Fiber Reactive Powder Concrete (HFRPC) columns that deflection for columns cured in chloride water more than tap water when compared at the same load that also by increase eccentricity leads to an increase in deflection for both cured and The neutral axis depth for HFRPC columns is more than NSC at the same load also when eccentricity increases, the compression zone decreases and neutral axis also decrease by increase eccentricity. These results occur when columns are cured in tap and chloride water.

في هذا البحث تم دراسة تصرف المقاطع للاعمدة الخرسانية المسلحة والمصنوعة من نوعين من الخرسانة العادية وذات المساحيق الفعالة والمهجنة بالالياف (steel and polypropylene fiber) تحت تأثير الحمل المحوري واللامحوري , تم صب الاعمدة ومعالجتها في نوعين مختلفين الاولى في المياه العادية ولمدة 28 يوم والثانية في المياه الكلوريدية ولمدة 6 اشهر و بتركيز ( 8341.6 ملغملتر) . يتضمن الجانب العملي ثلاث متغيرات هي نوع الخرسانة ونوع المعالجة ونوع التحميل, حيث تم صب وفحص 20 عمود خرساني بابعاد (120 × 120) ملم وبارتفاع 1200 ملم. في الفحص تم تسليط ثلاث انواع من الحمل وهي الحمل المحوري واللامحوري وهي (0, 50, 100, 150) ملم ونسبة (, 0) (e/h0.42 , 0.83 و 1.25 ) من سنتر العمود والحمل الاخير هو فحص النموذج كعتبة.اظهرت النتائج العملية زيادة في الحمل والمقاومة في كلا المعالجة العادية والكلوريدية للخرسانة المهجنة مقارنة بالخرسانة العادية من خلال الحصول على منحنيات القوى-الانفعال, نتائج الفحص للخرسانة العادية والمهجنة ومن خلال الرسوم تم استنتاج بأن الانفعال للخرسانة العادية والمهجنة عند معالجتها في المياه الكلوريدية هي اكثر من الانفعال لنفس الخرسانة عند معالجتها في المياه العادية. وكذلك بزيادة اللامحورية يزداد التشوه للخرسانة. وبنت النتائج بأن عمق المنطقة الانضغاطية للخرسانة ذات المساحيق الفعاله والمهجنة بالالياف هي اكثر من الخرسانة العادية عند نفس الحمل وكذلك بزيادة اللامحورية فان منطقة الانضغاط تقل وعمق المنطقة كذلك يقل وهذه النتائج تنطبق على كلا المعالجتين العادية والكلوريدية.


Article
Theoretical Study of Reactive Powder Concrete Deep Beams

Authors: Ragheed Fatehi Makki --- Ali TalibJassem --- Aseel Sultan Ridha
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 7 Pages: 299-313
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In the present work, the nonlinear finite element method (FEM) analysis by using package ANSYS V.11 has been carried out to analyze eleven tested RPC deep beams, have dimensions 150mm width, 400 mm depth and 1250 mm total length.The present research objective is to analyze the tested RPC deep beams by using three-dimensional nonlinear finite element (ANSYS Version 11.0) computer program was used in this work. Eight-node brick elements (SOLID 65) are used to represent the concrete and three dimensional (LINK 180) is a spar (or truss) element are used torepresent the steel reinforcement and element (SOLID 185) is used for the steel plates modeling. This compare between the numerical and experimental conclusion assured well airworthiness from this numerical analysis and this methodology developable in this study where this maximal distinction rate in this ultimate loading was about below 4.2% to total this tested and analyzed RPC deep beams.

في هذا العمل، تم اجراء تحليل لا خطيا بالعناصر المحددة باستخدام برنامجANSYS V.11 لأحدى عشرمن الأعتابالعميقة من خرسانة المساحيق الفعالة المفحوصة مختبريا، لها أبعاد 150 ملم عرض، 400 ملم عمق و1250 ملم الطول العتب.الهدف من البحث هو استعمال التحليل اللاخطي بواسطة العناصر المحددة(FiniteElements) ثلاثية الأبعاد كوسيلة عددية لدراسة وتحري تصرف هذه العتبات الخرسانية العميقة للمساحيق الفعالة باستخدام البرنامج (ANSYS¸ V.11) حيث تم في هذا البرنامج تمثيل الجزء الخرساني باستخدام العناصر الطابوقية ذات الثمانية عقد (Solid 65) وتم استخدام عنصر ثلاثي الابعاد (LINK180) لتمثيل حديد التسليح وتماستخدامعنصرثلاثيالابعاد (LINK185) لتمثيل صفيحة (بليت) حديد. تمت المقارنة ما بين النتائج العملية المستحصلة من الفحوصات المختبرية السابقة مع تلك النتائج النظرية المستحصلة من التحليل اللاخطي بواسطة العناصر المحددة ثلاثية الابعاد حيث اظهرت النتائج النظرية توافقا" جيدا" مع تلك النتائج العملية، حيث كانتأكبر نسبة مئوية للفرق في التحميل الأقصى للانحناء اقل من (4.2%).


Article
Bond Stresses between Reinforcing Bar and Reactive Powder Concrete
اجهادات الترابط بین قضیب التسلیح و خرسانۃ المساحيق الفعالة

Authors: Hussein Al-Quraishi حسين القريشي --- Nada Sahmi ندى سهمي --- Maha Ghalib مها غالب
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2018 Volume: 24 Issue: 11 Pages: 84-100
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A good performance of reinforced concrete structures is ensured by the bond between steel and concrete, which makes the materials work together, forming a part of solidarity. The behavior of the bond between the reinforcing bar and the surrounding concrete is significant to evaluate the cracking control in serviceability limit state and load capacity in the ultimate limit state. In this investigation, the bond stresses between reinforcing bar and reactive powder concrete (RPC) was considered to compare it with that of normal strength concrete (NSC). The push-out test with short embedment length is considered in this study to evaluate the bond strength, bond stress-slip relationship, and bond stress-crack width relationship for reactive powder concrete members. The compressive strength of concrete, the nominal diameter of reinforcement, concrete cover, and amount of steel fibers and embedded length of reinforcement were considered as variables in this study.The test results show that the ultimate bond stress increased with increasing of the compressive strength of concrete, decreasing the nominal diameter of the reinforcing bar, increasing the concrete cover and increasing steel fiber content. In a bond stress-slip relationship, the NSC specimen shows a very short softening zone after reaching the peak point in comparisons with RPC specimen. In RPC, bond stress-slip relationship shows stiffer behavior when the steel fiber content was increased. RPC shows stepper softening zone due to the presence of steel fiber, and the absence of steel fiber cause push-out failure without descending part after peak point. Using NSC instead of RPC in anchorage between reinforcement and concrete, decrease the crack width produced due to radial tensile stresses through the push-out of reinforcing bar. In RPC, the absence of steel fiber, decrease the nominal diameter of the reinforcing bar, increase the concrete cover, decrease the embedded length of reinforcing bar cause push-out failure and vice versa cause splitting failure.

الاداء الجيد للخرسانة المسلحة مضمون بالترابط بين خرسانة وحديد التسليح والذي يجعل المادة تعمل كقطعة واحدة .لمعرفة تصرف الترابط بين الخرسانة وحديد التسليح هو مهم للسيطرة على التشققات بالحدود الخدمية وبقوة التحمل بحدود المقاومة القصوى. في هذه الدراسة, اجهادات الترابط لخرسانة المساحيق الفعالة وحديد التسليح تم اخذها ومقارنتها مع الخرسانة العادية. تم اخذ فحص اجهاد الدفع لدراسة اجهادات الترابط, علاقة اجهاد الترابط مع التزحلق، علاقة اجهاد الترابط مع عرض التشقق. مقاومة الانضغاط، القطر الاسمي لحديد التسليح، الغطاء الخرساني، كمية الياف الحديد، طول التثبيت للقضيب تم اخذها كمتغيرات لهذه الدراسة. النتائج اظهرت ان اجهاد الترابط يزيد مع زيادة مقاومة الانضغاط، مع نقصان قطر القضيب، زيادة الغطاء الخرساني، مع زيادة كمية الياف الحديد. نموذج الخرسانة العادية اظهر نزول صغير بعد وصوله لاعلى نقطة مقارنة بخرسانة المساحيق الفعالة. علاقة اجهاد الترابط مع التزحلق اظهرت صلادة عالية للنموذج الذي يحتوي على اعلى نسبة الياف. خرسانة المساحيق الفعالة اظهرت نزول تدريجي بعد الوصول لاعلى نقطة بسبب وجود الياف الحديد، وبغيابه فشل الدفع لحديد التسليح سوف يحصل وبدون اي نزول بمنحني اجهاد الترابط-النزحلق. استخدام الخرسانة العادية بدل خرسانة الباودر التفاعلي سوف يقلل من عرض التشقق السطحي. في خرسانة الباودر التفاعلي غياب الياف الحديد، نقصان قطر القضيب، زيادة الغطاء الخرساني، نقصان طول الغرز للقضيب تؤدي الى فشل الدفع الخارجي والعكس يسبب فشل التشظي.


Article
Non- Distractive Testing of Reactive Powder Concrete

Authors: Mohammed Mosleh Salman --- Salwa Rahman Rasheed
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 6 Pages: 118-127
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

This research focuses on estimating of three important properties of reactive powder concrete; the distractive, anon-distractive testingandstatistical analysis suggest mathematical model. The ultrasonic pulse velocity test (NDT) method to study the properties of concrete.Fifty cubes withsize(150mm), fifty cylinders with diameter (150mm), height (300 mm), andfiftyprisms of dimensions (100*100*500) mm.,Statistical analysis was used to estimate the mechanical properties of reactive powder concrete (RPC),compressive strength, splitting tensile strength and flexural strength. Results showed that it is possible to estimate the mechanical properties using a mathematical model.

يهدف هذا البحث الى تخمين ثلاثة من اهم خواص خرسانة المساحيق الفعالة باستخدام فحوصات إتلافيه وفحوصات لإتلافيهبالإضافة الى برنامج تحليل الاحصائيلغرض اقتراح موديل رياضي لتخمين مقاومة انضغاط، مقاومة الانثناء، ومقاومة الشد الانفلاقي لخرسانة المساحيق الفعالة. تم صب 50 مكعب خرساني مقاس 150 مم , 50 اسطوانة بقطر 150 مم وارتفاع 300 مم وايضا صب 50 موشور بأبعاد (100*100*500مم) وبعد معالجتها معالجة اعتيادية في الماء لمدة 28 يوم تم فحصها فحصا لا ا تلافيا بوسطةفحص الامواج الفوق الصوتية كفحوصات لإتلافيه ومن ثم فحصها اتلافيا" لإيجاد مقدار مقاومة الانضغاط والشد والانثناء، وبعد ادخال قيم الفحص الاتلافي والائتلافي في برنامج التحليل الاحصائي تم التوصل الى امكانية تخمين الخواص الميكانيكية باستخدام المعادلات الرياضية المستنتجة.