Design and Implementation of an Automatic Control for Two Axis Tracking System for Applications of Concentrated Solar Thermal Power
تَصميم وتنفيذ تَحكّم آلي لمنظومة تَتبع ذاتُ محورين لتطبيقات الطاقة الحرارية الشمسية المُرَّكزة

Loading...
Loading...
Abstract

The present work presents design and implementation of an automated two-axis solar tracking system using local materials with minimum cost, light weight and reliable structure. The tracking system consists of two parts, mechanical units (fixed and moving parts) and control units (four LDR sensors and Arduino UNO microcontroller to control two DC servomotors). The tracking system was fitted and assembled together with a parabolic trough solar concentrator (PTSC) system to move it according to information come from the sensors so as to keep the PTSC always perpendicular to sun rays. The experimental tests have been done on the PTSC system to investigate its thermal performance in two cases, with tracking system (case 1) and without tracking system (case 2). The experimental results showed that the average solar radiation falling on the PTSC prototype in the two cases during the same time was 854 and 701 watt/m2, respectively, which means an increase in the solar radiation about 21.8 % when using tracking system. It was found that the average useful heat gain output of solar collector was equal to (376.2, 252.6 watt) for the two cases, respectively, so there was an increase of about 48.9 % when using the tracking system. Also, the average thermal efficiency of the PTSC was found to be (20.7, 26.5 %) for the two cases, respectively, which means an increase in the average efficiency by 28% with use of tracking system compared to the fixed case.

يُمثل العمل الحالي تصميم و منظومة تتبع شمسي ذاتية الحركة ذات محوريين بأستخدام مواد محلية وتنفيذها بأقل كلفة وأخف وزناً وموثوقية بناء. منظومة التتبع تتألف من جزأين: الوحدات الميكانيكية (الأجزاء الثابتة والمتحركة) ووحدات التحكم الكهربائية (من اربعة متحسسات ضوئية من نوع LDR ومسيطر دقيق نوع أردوينو الذي يقوم بالسيطرة على محركيين نوع ذاتي الحركة يعملان بالتيار المستمر) . إنّ منظومة التتبع ثنائية المحاور تأتي متُلائمة ومُجمتعة سوية مع المُركّز الشمسي ذي القطع المكافىء لتحريك المُركز وبحسب المعطيات القادمة من المتحسسات الضوئية لكي تُبقى المُركز الشمسى بشكل دائم عمودياً على الاشعة الساقطة من الشمس .أجريت الأختبارات التجربية على المُركز الشمسي لتقويم الأداء الحراري في حالتين: (الحالة الأولى) بأستخدام منظومة التتبع الشمسي و(الحالة الثانية) عند عدم استخدامها. بَيّنت النتائج التجريبية المستحصلة بأن مُعدل أشعة الشمس الساقطة على المُركز الشمسي في الحالتين هي على التوالي (854 واط/متر2 و 701 واط/متر2) وهذا يعني زيادة في معدل الأشعاع الشمسي حوالى 21.8 % عند استخدام منظومة التتبع. لقد وُجدَ بأن معدل الحرارة المفيدة المكتسبة للمُركز الشمسي للمدة نفسها وللحالتين أعلاه هي على التوالي (376.2 واط و 252.6 واط) وهذا يعني زيادة حوالى 48.9 % عند استخدام منظومة التتبع وكما وجد بأن مُعدل الكفاءة الحرارية للمُركز الشمسي في حالتي التتبع كانت على التوالي (26.5% و 20.7%) وهذا يعني زيادة بمقدار 28 % عند استخدام منظومة التتبع ثنائي المحاور بالمقارنة مع المنظومة الثابتة.


Article
Experimental Investigation on Flat Plate Solar Collector with Integrated Wickless Heat Pipe
دراسة عملية على مجمع شمسي نوع فلات بليت باستخدام الانبوب الحراري

Authors: Mohammed Hasan Abbood --- Ahmed Jabbar Hasan
Journal: journal of kerbala university مجلة جامعة كربلاء ISSN: 18130410 Year: 2018 Volume: 16 Issue: 1 Pages: 182-191
Publisher: Kerbala University جامعة كربلاء

Loading...
Loading...
Abstract

An experimental study is carry out to investigate the effectiveness of a flat plate solar collector (FPSC) through replacing the riser tubes by integrated wickless heat pipe (WHP) heat exchanger. The study show the effect of working fluid filling charge of the WHP, the tilt angle, and inlet coolant temperature on the solar system performance. A FPSC with area of (0.76*0.96) m2 built with copper WHP of 19mm evaporator tubes outer diameter and single horizontal condenser of 28mm outer diameter using distilled water with (40, 60, and 80) % filling ratios as a working fluid inside the WHP. The collector efficiency was directly affected by the filling ratio of the WHP while tilt angle is contributed to solar radiation more than WHP performance.

دراسة عملية للتحقق من فعالية المجمع الشمسي ذو اللوح المسطح من خلال استبدال الانابيب الناقلة بأنبوب حراري (بلا فلتيلة ) متكامل كمبادل حراري. تظهر الدراسة تأثير نسبة ملئ مائع التشغيل في الانبوب الحراري, زاوية الميلان, ودرجة حرارة الدخول لمائع التبريد على اداء المنظومة الشمسية. تم تصنيع المجمع الشمسي بمساحة (0.76*0.96) م2 مع انبوب حراري من النحاس بقطر خارجي للمبخر 19 ملم وانبوب افقي كمكثف بقطر خارجي 28 ملم واستخدام الماء كمائع تشغيل داخل الانبوب الحراري بنسب ملئ (40,60,80) % . وجد ان كفاءة المجمع تتأثر بشكل مباشر بنسبة ملئ مائع التشغيل للأنبوب الحراري بينما زاوية الميلان تتأثر بشدة الاشعاع الشمسي اكر من اداء الانبوب الحراري


Article
EXPERIMENTAL STUDY THE EFFECT OF ABSORBING TUBE DIAMETER ON THE PERFORMANCE OF COMPOUND PARABOLIC CONCENTRATOR SOLAR COLLECTOR

Authors: Talib Zghayer Farge --- Abdul Aziz Ali --- Hiba Ali Hussein
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2018 Volume: 22 Issue: 4 Pages: 247-255
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

A system of test rigs of solar collectors with the compound parabolic concentrator (CPC) have designed to study the performance namely (heat flux and efficiency) for all the solar collectors. The acceptance angle of the CPC taken at 45⁰ for all the solar collectors. The system used to study the effect of absorbing tube diameter on the solar collector performance. A halogen light used as energy source with different absorber tube diameters (0.75, 1, and 1.5) inch used. It has observed that the relationship between the time with the readings of water temperature inside the absorber tube and the performance results show that there are three regions for variation for all collectors. The variation for the water temperature, heat flux and efficiency in the first region varied sharply, in the second region varied gradually and in the third region remained constant. The compering performance results between the different solar collectors with different absorber tube diameters show that the collector with 1.5-inch absorber tube diameter gives the best performance than the others. Where the percentage increase in the temperature for the collector with absorber tube diameter of 1.5 inch compering with the other diameters ( 0.75 , 1 ) inch are (28.3 and 20.7) respectively While in case of heat flux are (69.8 and 53.4) and for the efficiency are (68.8 and 28).


Article
NUMERICAL AND EXPERIMENTAL STUDY OF HEAT TRANSFER ENHANCEMENT FOR DIFFERENT BASE FLUIDS USING AL2O3 ON F.P.S.C UNDER SOLAR SIMULATION

Authors: Abbas S. Shareef --- Ali A. Dibs
Journal: KUFA JOURNAL OF ENGINEERING مجلة الكوفة الهندسية ISSN: 25230018 Year: 2018 Volume: 9 Issue: 3 Pages: 37-51
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

In this research paper, the solar irradiance of flat plate solar collector was evaluated using experimental and numerical analysis. In the experiment, an automatic solar simulator was designed and built to simulate the solar irradiance. The simulator was controlled by an Arduino board. The light source and fabrication of the simulator were used for a wide range of testing and the comparison was made between different cases. The test was performed on a flat plate double glazing solar collector with different base fluids; ethylene glycol (EG), glycerine, and water. To enhance the heat transfer, Al2O3 nanoparticles having a diameter of 20 nm were added. In order to investigate the effect of volume fraction on the heat absorption, three-volume fractions, 0.2%, 0.45, and 0.6%, were used in this study. Laminar flow was considered with a flow rate of 1 L/min. Solar irradiance was measured from 11:00 to 13:00 on September 25th, 2016. COMSOL 5.2a was used in a numerical analysis of flat plate solar collector. A good agreement between numerical and experimental for all cases was observed. The maximum temperature difference between inlet and outlet was found when the (water/ Al2O3) was used as a working fluid at a volume fraction of 0.6%.


Article
THERMAL PERFORMANCE OF PARABOLIC TROUGH SOLAR COLLECTOR
ألاداء الحراري لمجمع شمسي نوع قطع مكافئ خطي

Loading...
Loading...
Abstract

This work presents design, instrumented and test of a parabolic trough solar collector under Baghdad climate conditions (of latitude 33.33o N, of longitude 44.4o E). The parabolic trough solar collector consists of: a mirror matrix or tapes which work as reflective surface of (2m *1m), absorber copper tube (receiver), two axis tracking system. Water is used as a heat transfer medium. The setup is tested within clear days from June, to September 2017. The collector heat gain, efficacy and temperature of absorber were presented for absorber five different circulating mass flow rates of (0.15, 0.2, 0.3, 0.4, 0.5) 1pm. The results show that the maximum thermal efficiency of the parabolic trough solar collector is 80.26%. The maximum outlet temperature of the absorber tube reaches 81 oC at the noon when water flows at (0.15) 1pm. The maximum obtained heat gain is (1619W) for (0.5) 1pm flow rate of water.

هذا العمل تمثل بتصميم وتجهيز المنظومة باجهزة القياس والفحص لمجمع شمسي نوع قطع مكافئ (مركز) في ظل الظروف المناخية لبغداد العراق (خط عرض 33,3شمالا وخط طول 44,2o شرقا). يتكون المجمع الشمسي من مصفوفات او الاشرطة من المرايا التي تعمل كسطح عاكس (1 م * 2 م), انبوب سطح المستلم النحاسي ومنظومة تعقب ثنائية المحاور. استخدم الماء كوسيط لنقل الحرارة. تم اجراء التجارب في ايام مشمسة من شهر حزيران الى شهر ايلول 2017. تم عرض الحرارة المتجمعة المستفاة , كفاءة المجمع الشمسي, درجة حرارة انبوب السطح الماص لخمس قيم من معدل تدوير الماء والتي كانت (0,15- 0,2- 0,3- 0,4- 0,5) لتر/دقيقة. اظهرت النتائج المستحصلة من التجارب العملية ان اقصى كفاءة للمجمع الشمسي هي 80,26%. اقصى درجة حرارة خروج للمائع من انبوب الماص 81 درجة مئوية في منتصف الظهيرة عندما كان معدل تدويرالماء 0,15 لتر/دقيقة. اقصى حرارة متجمعة مستفادة تم الحصول عليها هي (1619 واط) نما كان معل تدوير الماء 0,5 لتر/دقيقة.


Article
The Variation Effect of Collector Tilt Angle on the Heat Pipe Solar Collector Performance
تأثير تغير زاوية ميل المجمع الشمسي على اداء المجمع الشمسي الذي يعمل بمبدأ الانبوب الحراري

Author: Abdulsalam D. M.Hassan عبد السلام داود
Journal: Wasit Journal of Engineering Sciences مجلة واسط للعلوم الهندسية ISSN: 23056932 Year: 2018 Volume: 6 Issue: 2 Pages: 21-27
Publisher: Wassit University جامعة واسط

Loading...
Loading...
Abstract

The thermal performance of FPHPSC has been studied experimentally and theoretically. The collector consists of copper absorber plate, single glass cover, glass wool insulation and aluminum case, ten wickless heat pipes of 12.7 mm inner diameter. The experimental studies of collector performance have been performed on four different CTA (22°, 32°, 45° and 60°). The relation between the solar intensity and the collector energy losses are also discussed. The collector are tested under the climate condition of Kut city (32.602 latitude and 45.752 longitude). It is investigated that the increasing of CTA increase the efficiency of collector up to certain limit after that the efficiency decreases with the increasing of tilt angle of collector. A computer program which is based on VISUAL BASICE language (version 6) is made for the theoretical analysis. The experimental results agree reasonably with the theoretical predictions.

أجريت دراسة نظرية وعملية لتحديد ألأداء الحراري لمجمع الطاقة الشمسية مسطح يعمل بمبدأ الانبوب الحراري. ويتكون المجمع من لوح امتصاص من النحاس ,غطاء زجاجي منفرد, عازل من الصوف الزجاجي , صندوق من الألومنيوم , وعشرة أنابيب حرارية بقطر داخلي. (12.7 mm) أجريت الدراسات التجريبية على أداء المجمع بأستخدام أربعة زوايا ميل للمجمع عن المستوي الافقي (tilt angles) هي (22 °، 32 °، 45 ° ,60) درجة. و تمت دراسة العلاقة بين شدة الاشعاع الشمسي وكمية الخسائر الحرارية للمجمع تحت حالة المناخ لمدينة الكوت/جمهورية العراق(32) درجة شمالا. اظهرت ألنتائج بأن زيادة زاوية ميل المجمع تزيد كفاءة المجمع الى حد معين بعدها تبدأ كفاءة المجمع بالنقصان مع استمرار زيادة زاوية ميل المجمع. تم بناء برنامج للحاسوب يعتمد على لغة (VISUAL BASIC) الاصدار السادس لغرض التحليل النظري لأداء المجمع أتفقت النتائج التجريبية بشكل معقول مع التوقعات النظرية.


Article
Experimental Study of Solar Collector Performance with Serpentine Mini-Channel

Authors: Zainab H.Naji1 --- Mohammed Fowzi M --- Maryam Ali A.Ameer
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 6
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In this paper, experimental has been executed to investigate thermal performance of modified design of mini-channel plate solar collector. For the application of mini-channel heat exchangers, it is necessary to have perfect design tools for prophesy pressure drop and heat transfer. Experimental setup were carried out in Baghdad city from (July) with a tilt angle of (30º) to the south under sunny weather condition. The working fluid is propylene glycol in the laminar regime is used for experimental investigation at constant fluid inlet temperature (15ºC - 20 ºC)and at different flow rates (4.6L/h, 5.77L/h, 7.96L/h, 11.2L/h, and 18.35L/h). The mini- channel solar collector performance is evaluated in terms of heat transfer coefficient, pressure drop, friction factor pumping power, and working fluid temperature difference between the outlet and the inlet .In this paper study the test rig with selective coating and with cover glass The experimental results show that an increase in mass flow rate the heat transfer coefficient is also increased while the friction factor is decreased. Also, increase in mass flow rate lead to the temperature difference between the outlet and the inlet working fluid decreases.

الهدف من هذه الدراسة تنفيذ التجريبية للتحقيق في الأداء الحراري للوح مجمع طاقة شمسية يعمل ع اساس قناة مصغرة. لتطبيق المبادلات الحرارية قناة صغيرة، فمن الضروري أن يكون أدوات تصميم مثالية لتنبأ انخفاض الضغط ونقل الحرارة. جميع التجارب العملية اجريت في مدينة بغداد خلال (تموز) عند زاوية ميلان (°30) درجة باتجاه الجنوب تحت ظروف الطقس المشمس. تم استخدام مائع عمل هو بروبلين كلايكول في جريان طباقي خلال تحقق التجارب العملية عند درجة حرارة دخول ثابتة (20) Cº-15)) ولمعدلات تدفق مختلفة (4.6 لتر/ساعة،5.77لتر/ساعة ،7.96لتر/ساعة ،11.2لتر/ساعة و18.35لتر/ساعة). تم تقييم اداء المجمع الشمسي من حيث معامل انتقال الحرارة، انخفاض الضغط، عاملالاحتكاك، طاقة الضخ، وفرق درجات حرارة الدخول والخروج. في هذه الدراسة تم اختبار الجهاز جود طلاء انتقائي وجود غطاء زجاجي بينت النتائج العملية ان زيادة معدل التدفق تؤدي الى زيادة معامل انتقال الحرارة بينما معامل الاحتكاك يقل. ايظا زيادة معدل التدفق تؤدي الى نقصان الفرق درجات الحرارة لمائع العمل بين الدخول والخروج.


Article
Heat Transfer Analysis of Modified Solar Collector Plate with Mini-Channel

Authors: Zainab H.Naji1 --- Mohammed Fowzi M. --- Maryam Ali A. Ameer
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2018 Volume: 26 Issue: 7 Pages: 314-330
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

In this paper, experimental and numerical analyses have been executed to investigate the thermal performance of modified design of mini-channel plate solar collector. For the application of mini-channel heat exchangers, it is necessary to have perfect design tools for predictingthe pressure drop and heat transfer.A numerical model combining solar radiation with convective heat transfer to the absorber plate based on mini-channel has been developed. Reynolds number ranged from 70 to 300 at the fluid flow rate ranged from 4.6L/h to 18.35L/h is used for experimental investigation at fluid inlet temperature (20°C); the working fluid is propylene glycol. The mini channel solar collector performance is evaluated in terms of heat transfer coefficient, Nusselt number, friction factor, and pumping power. The result revealed that when there is an increase in the mass flow rate of flowing fluid, the convective heat transfer coefficient is increased, while the friction factor is decreased.

الهدف من هذه الدراسة تنفيذ التحليلات العملية والعددية للتحقيق في الأداء الحراري للوح مجمع طاقة شمسية يعمل على اساس قناة مصغرة. لتطبيق المبادلات الحرارية قناة صغيرة، فمن الضروري أن يكون أدوات تصميم مثالية لتنبأ انخفاض الضغط ونقل الحرارة. النموذج الرقمي يجمع بين الإشعاع الشمسي مع نقل الحرارة الحمل إلى لوحة امتصاص على أساس قناة صغيرة وكان عدد رينولد يتراوح بين 70 و 300 في معدل تدفق السوائل تراوحت من (4.6لتر/ساعة الى 18.35 لتر/ساعة)يستخدم للتحقيق التجريبي في درجة حرارة مدخل السائل (℃20 درجة مئوية). كان السائل العامل البروبيلين جلايكول. يتم تقييم أداء قناة تجميع الطاقة الشمسية البسيطة من حيث معامل انتقال الحرارة، عدد نسلت، عامل الاحتكاك وضخ الطاقة. وتكشف النتيجة أنه عندما يكون هناك زيادة في معدل تدفق الكتلة من السائل المتدفق، فإن معامل انتقال الحرارة الحراري يزداد أيضا في حين ينخفض معاملالاحتكاك.


Article
Numerical Simulation of Thermal-Hydrodynamic Behavior within Solar Air Collector
المحاكاة العددية للسلوك الحراري الهيدروديناميكي داخل مجمع الهواء الشمسي

Authors: Mustafa T. Mustafa مصطفى طارق مصطفى --- Ayad T. Mustafa اياد طارق مصطفى
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2018 Volume: 24 Issue: 3 Pages: 29-41
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Solar collectors, in general, are utilized to convert the solar energy into heat energy, where it is employed to generate electricity. The non-concentrating solar collector with a circular shape was adopted in the present study. Ambient air is heated under a translucent roof where buoyant air is drawn from outside periphery towards the collector center (tower base). The present study is aimed to predict and visualize the thermal-hydrodynamic behavior for airflow under inclined roof of the solar air collector, SAC. Three-dimensional of the SAC model using the re-normalization group, RNG, k−ε turbulence viscus model is simulated. The simulation was carried out by using ANSYS-FLUENT 14.5. The simulation results demonstrated that at same insolation; airflow, ground and air temperatures increase when the collector radius decreases towards the collector center. The ground temperature and air velocity increase, while airflow temperature decreases when the inclination angle increases from 0° to 20° due to changing in airflow movement. More decreasing in airflow temperature has been occurred when the inlet height increases from 0.1m to 0.25m. The simulation results were validated by comparing with the experimental data. In conclusions, the obtained results showed the capability of producing warm airflow to generate electricity in Baghdad city.

تستخدم المجمعات الشمسية, بشكل عام, لتحويل الطاقة الشمسية إلى طاقة حرارية, حيث ينتفع بها لتوليد الكهرباء. المجمع الشمسي الغير التركيزي ذو الشكل الدائري هو الذي اعتمد في الدراسة الحالية. يتم تسخين الهواء المحيط تحت مظلة شفافة حيث يسحب الهواء الطافي من المحيط الخارجي نحو مركز المجمع (قاعدة البرج). تهدف الدراسة الحالية إلى تنبؤ واظهار السلوك الحراري-الهيدروديناميكي لتدفق الهواء تحت سقف مائل لمجمع هواء شمسي. نموذج مجمع الهواء الشمسي باستخدام نموذج اللزوجة المضطرب RNG k−ε تم محاكاته. تم تنفيذ المحاكاة باستخدامANSYS FLUENT 14.5 . أظهرت نتائج المحاكاة أنه لنفس الاشعاع الشمسي: تدفق الهواء, درجة حرارة الهواء والارض تزداد عندما يتناقص نصف قطر المجمع تجاه مركزه. درجات حرارة الارض وسرعة الهواء تزداد, بينما درجات حرارة الهواء تنخفض عندما تزداد زاوية الميل من 0° الى 20° نتيجة لتغير حركة تدفق الهواء. انخفاض اكثر في درجات حرارة الهواء حدث عندما ازداد ارتفاع مدخل المجمع من 0.1 م الى 0.25 م. تم التحقق من صحة نتائج المحاكاة بالمقارنة مع البيانات التجريبية. كشفت الاستنتاجات من النتائج المستخلصة على مقدرة الهواء الساخن المنتج من المجمع الشمسي على توليد الكهرباء في مدينة بغداد.


Article
The Effect of using different Nano fluids on Heat Transfers through Flat Plate Solar Collector
تأثير إستخدام موائع نانوية مختلفة على انتقال الحرارة خلال مجمع شمسي مسطح

Authors: Zahraa Basim Abdel-Mohsen زهراء باسم عبد المحسن --- Abbas Sahi Shareef عباس ساهي شريف
Journal: Wasit Journal of Engineering Sciences مجلة واسط للعلوم الهندسية ISSN: 23056932 Year: 2018 Volume: 6 Issue: 2 Pages: 46-55
Publisher: Wassit University جامعة واسط

Loading...
Loading...
Abstract

In this paper investigation experimentally the effect of CuO-water and Al2O3/water nanofluids on heat transfer in flat plate solar collector. The volume fraction was used (0.125,0.25 and 0.5) % for flow flow rate of working fluid equal to (1 L/min) and the particles size was 20 nm. The experiments are conducted in Kerbala, Iraq with the latitude of 32.60 N. The result shows that the maximum outlet-inlet temperatures difference obtained at (0.5 vol. %) nanofluid are (16.2 0C) for (Al2O3/water), (15.5 0C) for (CuO/water) nanofluid, and (10.2 0C) for pure water. Also, Al2O3 shows high heat transfer compared to CuO, this lead to improve the performance of the solar fat-plate collector.

وتضمن البحث التحقق عمليا تأثير (الجزيئات النانوية من أوكسيد النحاس و أوكسيد الالمنيوم مع الماء) علي عملية انتقال الحرارة في المجمع الشمسي لوح مسطح. التراكيز الحجمية المستخدمة هي 0.125,0.25 and 0.5))% لمعدل جريان (1 lpm) وعند قطر جزيئة (20 nm). التجارب أٌجريت في كربلاء، العراق مع خط عرض (32.60 شمالا). أظهرت النتائج أن الحد الأقصى لفروق درجات الحرارة بين الدخول والخروج تم الحصول عليه عند تركيز (0.5 vol. %) هو (16.2 0C) لمائع النانوي) اوكسيد الالمنيوم مع الماء) (15.50 C), لمائع النانوي (اوكسيد النحاس مع الماء) و (10.2 0 C) للماء. أيضا, جزيئات النانوية لاوكسيد الالمنيوم تبين انها تملك نقل حراري عالي بالمقارنة مع جزيئات النانوية لاوكسيد النحاس هذا يؤدي إلى تحسين أداء المجمع الشمسي لوح مسطح.