Effect of photo chemical etching and electro chemical etching on the topography of porous silicon wafers surfaces
تأثير التنميش الكيميائي الضوئي والتنميش الكهروكيميائي على طبوغرافية سطوح شرائح السليكون المسامي

Author: Amjad Hussein Jassem امجد حسين جاسم
Journal: Tikrit Journal of Pure Science مجلة تكريت للعلوم الصرفة ISSN: 18131662 Year: 2019 Volume: 24 Issue: 4 Pages: 52-56
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

In This research we study the effect of photo chemical etching and electrochemical etching on topography of porous silicon surfaces, the results showed that photo chemical etching produced roughness silicon layer which can have thickness be less of porous silicon layer which is produced by electro chemical etching When all the wafers have same etching time and hydrofluoric solution (HF) concentration, the wafers have same resistance (10 Ω.cm).Also the results showed the roughness of porous silicon layers produced by electro chemical method which is bigger than the roughness of porous silicon layers produced by photo chemical method and the results of roughness of porous silicon layers, Pore diameter and porous layer thickness were produced by electro chemical method (1.55(µm) ((0.99(µm)) and ((1.21(µm) respectively), the results of roughness of porous silicon layers, Pore diameter and porous layer thickness were produced by photo chemical method 0.63)) nm -1.55)) (µm) ),so the (84.9 (nm)- and (3.94(nm) respectively .This is reinforces because of using the electro chemical to etching the wafer surf ace of bulk silicon and changing it to roughness silicon surface be share in success of many practicalities.

تم في هذا البحث دراسة تأثير التنميش الكيميائي الضوئي والتنميش الكهروكيميائي على طبوغرافية سطوح السليكون المسامي، اذ اظهرت النتائج ان التنميش الكيميائي الضوئي انتج طبقة سطحية ذات خشونة اقل سمكا مما انتجه التنميش بالطريقة الكهروكيميائية وعند ظروف التصنيع نفسها من تركزHF و زمن تنميش ومقاوميه نفسها (.cm Ω 10).كما تبين ان الخشونة كانت اكبر لسطوح شرائح السليكون المسامي المنتجة بالطريقة الكهروكيميائية مما هي عليه سطوح السليكون المسامي المنتجة بالطريقة الكيميائية الضوئية اذ اظهرت النتائج ان قيم الخشونة وقطر المسام وسمك الطبقة المسامية للسطوح السليكونية المنتجة بالطريقة الكهروكيميائية كانت (1.55(µm) و(mµ)(0.99) و(mµ)(1.21) على التوالي، بينما اظهرت النتائج ان قيم الخشونة وقطر المسام وسمك الطبقة المسامية للسطوح السليكونية المنتجة بالطريقة الفوتوكيميائية كانت nm) (0.63) و ( (nm)(84.9) و(nm)(3.94) على التوالي.وهذا يعزز من امكانية استعمال الطريقة الكهرو كيميائية الضوئية لحفر سطوح شرائح السليكون الكتلي وتحويلها الى شرائح سليكون ذات سطوح خشنة تسهم في انجاح عدة تطبيقات عملية.


Article
Compression and Wear Properties of Biocompatible Commercially Pure Titanium and (Titanium-Silicon) Alloys

Authors: Emad S. Al-Hassania --- Jamal J. Dawood --- Balsam M. Al-Sabe’a
Journal: Anbar Journal of Engineering Sciences مجلة الأنبار للعلوم الهندسية ISSN: 19979428 Year: 2019 Volume: 8 Issue: 1 Pages: 54-60
Publisher: University of Anbar جامعة الانبار

Loading...
Loading...
Abstract

The porous Titanium is characterized by high permeability which can assure the ingrowth of bone tissues, and consequently results in a good bonding between the metallic implant and the bone. In this work, Silicon element was added to the Commercially Pure Titanium at different weight percent of (2, 4, 6, 8 and 10) to investigate its effect on the porosity percentage, mechanical properties of the resulted samples. XRD analysis stated that at (Si) content lower than (2 wt%) the alloy is single phase (α- Ti alloy), as the Silicon content increased, in addition to (αphase), (Ti5Si3) intermetallic compound developed in the alloy. Porosity measurement results showed that the porosity percentage increases with the increase in Silicon content. Wear results stated that the wear rate increases with the increase in silicon content due to the increase in porosity percentage while the hardness results stated that there is no significant effect for Ti5Si3 intermetallic compound on improving the hardness of the samples. This is attributed to its low percent and the major effect of porosity on hardness which declined the effect of Ti5Si3 by reducing the hardness of the alloy compared with the master sample. The obtained results of the (yield strength, ultimate compressive strength and Young’s modulus) were within the values that match bone’s properties. This means these materials are suitable for biomedical application


Article
Characterization and In Vitro evaluation of a novel coated nanocomposite porous 3D scaffold for bone repair
التوصيف والتقييم في المختبر للسقالة الثلاثية الأبعاد المسامية المركبة النانوية الأصيلة والمغلفة لإصلاح العظام

Loading...
Loading...
Abstract

The aim of this study is to tissue engineer a 3D scaffold that can be used for load bearing segmental bone defects (SBDs) repair. Three different scaffolds were fabricated using cockle shell-derived CaCO3 aragonite nanoparticles (CCAN), gelatin, dextran and dextrin with coated framework via Freeze-Drying Method (FDM) labeled as 5211, 5211GTA+Alginate, 5211PLA. Scaffolds were assessed using Scanning Electron Microscopy (SEM). The cytocompatibility of the organized scaffolds was assessed using cells multiplication and alkaline phosphatase (ALP) concentration via In Vitro cell culture using human Fetal OsteoBlast cells line (hFOB). The results showed a substantial difference in ALP concentrations between the cultures of different scaffolds leachable medium during the study period. The biological evaluation also showed that three scaffolds did enhanced the osteoblast proliferation rate and improved the osteoblast function as demonstrated by the significant increase in ALP concentration. Engineering analyses showed that scaffolds possessed 3D interconnected homogenous porous structure with a porosity ranging 6%-49%, pore sizes ranging 8-345 µm, mechanical strength ranging 20-65 MPa, young’s modulus ranging 166-296 MPa and enzymatic degradation rate between 16%-38% within 2-10 weeks. The in vitro evaluation revealed that the scaffold 5211, 5211GTA+Alginate and 5211PLA fulfill all the main requirements to be considered as an ideal bone replacement.

هدفت هذه الدراسة هو تصميم سقالة نسيجية ثلاثية الأبعاد والتي يمكن استخدامها لإصلاح عيوب قطعية الحاملة للعظام.تم تحضير ثلاثة أنواع مختلفة من السقالات باستخدام جسيمات نانوية أراغونيت من كربونات الكالسيوم المشتقة من القواقع ممزوجة مع الجيلاتين، ديكستران والدكسترين والمغلفة بإطار عبر التجفيف بالتجميد وتم تسميتها 5211 و 5211 GTA+Alginate و 5211PLA. تم تقييم السقالات باستخدام الفحص بالميكروسكوب الإلكتروني وجرى تقييم التوافق الهيولي للسقالات باستخدام معدل تكاثر الخلايا وتركيز الفوسفاتيز القلوية عن طريق زراعة الخلايا العظمية الجنينية البشرية داخلها. أظهرت النتائج وجود اختلاف كبير في تركيز ALP بين أوساط ارتشاحات السقالات المختلفة خلال فترة الدراسة. أظهر التقييم البيولوجي أيضا أن السقالات الثلاثة عززت معدل انتشار الخلايا العظمية وحسنت وظيفة الخلايا بانية العظم من خلال زيادة الكبيرة في تركيز ALP. أظهرت التحليلات الهندسية أن السقالات تمتلك بنية مترابطة متجانسة مسامية ثلاثية الأبعاد بمسامية تتراوح بين 6-49٪، أحجام مسام تتراوح ما بين 8-345 مايكرون، والقوة الميكانيكية تتراوح بين 20-65 ميجا باسكال، معامل يونغ تراوح بين 166-296 ميجا باسكال ومعدل التحلل الأنزيمية بين 16-38 ٪ خلال 2-10 أسابيع. كشف التقييم في المختبر أن السقالات الثلاثة بإمكانها تلبية جميع المتطلبات الرئيسية التي يمكن من خلالها اعتبارها بديلا مثاليا للعظام.


Article
Influence of Varying Temperature and Concentration on MHD Peristaltic Transport for Jeffrey Fluid with Variable Viscosity through Porous Channel

Authors: Dheia G. Salih Al-Khafajy --- Ahmed A .Hussein Al-Aridhee
Journal: Journal of Al-Qadisiyah for Computer Science and Mathematics مجلة القادسية لعلوم الحاسوب والرياضيات ISSN: 20740204 / 25213504 Year: 2019 Volume: 11 Issue: 3 Pages: Math Page 38-49
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

The present paper deals with the peristaltic motion of Jeffrey fluid with varying temperature and concentration through a porous medium in a coaxial uniform circular tube. The fluid is assumed to be non-Newtonian, namely Jeffrey fluid. The inner tube is uniform, while the outer flexible tube has a sinusoidal wave traveling down its wall. The analytical formulas of the velocity and temperature have been obtained in terms of the Bessel function of first and second kinds. The numerical formula of the axial velocity, temperature and concentration are obtained as functions of the physical parameters of the problem (Darcy number, magnetic parameter, thermal Grashof number, Reynolds number, Prandtl number, and Schmidt number) with other physical parameters are obtained. The Influence of physical parameters of the problem on this formula are discussed numerically and illustrated graphically through a set of figures.


Article
The Porosity Effect of Stainless Steel Balls on Forced Convection Pipe Flow
تأثير مسامية كرات الفولاذ المقاوم للصدأ على تدفق الأنبوب الحراري القسري

Authors: Ayser Munner Flayh أيسر منير فليح --- Sajida Lafta Ghashim ساجدة لفته غشيم
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2019 Volume: 22 Issue: 2 Pages: 102-108
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

An experimental study has been carried out to investigate the effects of stainless-steel balls on forced convection flow in pipe under uniform heat flux. Water is used as the working fluid and stainless-steel balls as a porous media. The Reynolds number range from (5000 to 9000) based on the diameter of the pipe. The experiments were conducted on three various numbers of stainless-steel balls (N) with various diameters (dp), which give various porosity (0.33, 0.38 and 0.41). These are (N= 2400, dp=1mm), (N=1600, dp=3mm) and (N= 750, dp=5mm). Results show that, heat transfer coefficient increases with the decrease in the porosity due to the reduction in the space between balls. This led to an increase in turbulence and produced eddies. Furthermore, enhancement in heat transfer coefficient reached its maximum value of (45%) for ball diameter with (dp=1mm) and water flow rate (9 L/min). New Correlation equations for the average heat transfer coefficient were obtained for three different diameters of balls (1, 3 and 5 mm).

اجريت دراسة عملية للتحقيق في تاثير كرات الفولاذ المقاوم للصدأ على التدفق الحراري القسري في الأنابيب تحت تدفق فيض حراري منتظم. يستخدم الماء كسائل العمل وكرات الفولاذ المقاوم للصدأ كوسط مسامي. يتراوح عدد رينولدز من (5000 إلى 9000) بناءً على قطر الأنبوب. أجريت التجارب على ثلاثة انواع من الكرات المختلفة في العدد والقطر ( , القطر=1ملم , عدد الكرات= 2400 كرة ( ، (القطر =3 ملم ، عدد الكرات=1600 كرة )، (القطر= 5ملم ، عدد الكرات = 750 كرة) والتي تعطي مسامية مختلفة (0.33 ، 0.38 ، . (0.41 تظهر النتائج أن معامل انتقال الحرارة يزداد مع انخفاض المسامية بسبب انخفاض المسافة بين الكرات وهذا أدى إلى زيادة الاضطراب والدوامات المتولدة. بالاضافة الى ذلك ، فقد تم تحسين معامل انتقال الحرارة إلى أقصى قيمة له بمقدار (45٪) لقطر الكرة ( 1ملم( ومعدل تدفق الماء (9 لتر/ دقيقة.( تم الحصول على معادلات تصحيحية جديدة لمتوسط معامل انتقال الحرارة لثلاثة أقطار مختلفة من الكرات (1 ، 3 ،5 ) ملم .


Article
MHD Stagnation-Point Flow of Non-Newtonian Fluid and Heat Transfer over Stretching/Shrinking Sheet in a Porous Medium

Authors: Ala'a Abdul-Raheem Hammodat --- Anas Ihsan Basheer
Journal: JOURNAL OF EDUCATION AND SCIENCE مجلة التربية والعلم ISSN: 1812125X Year: 2019 Volume: 28 Issue: 1 Pages: 71-82
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

In this work, we study the stagnation point flow of Casson fluid andheat transfer phenomena in presence of thermal radiation and magnetic field. We used the suitable similarity transformation to reduce governing partial differential equations into ordinary differential equations, these equations are solved numerically using Rang-Kutta method. Effects of non-dimensional parameters on velocity, temperature are discussed and presented through graphs as well as coefficient of skin friction and local Nusselt numbers is investigated stretching/shrinking cases.


Article
The Performance Prediction of The Mixed Convection In an Inclined Circular Tube Filled Porous Media Based on an Intelligent Control

Author: Musa Mustafa Weis
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2019 Volume: 26 Issue: 2 Pages: 9-14
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

The porous media has a significant impact on the heat transfer and storage properties. The present study focuses on the heat transfer of the mixed convection through a circular tube that filled with a porous media at different angles using a neural network. An experiment had been performed for the Rayleigh number range from 108.54 to 907.73 and the Peclet number range 30.3.-510 using three tests for the heat flux. The result shows the mean relative error about 7.913% and the coloration coefficient (R2) Is 99.18% for the train data. The mean relative error about 6.641% and the R2 is 99.46%, for the test data. The results showed that effectiveness of ANN in the predicted thermal performance in thermal engineering applications such as heat transfer modeling using porous media with airflow.


Article
Experimental Study ofForced Convection Heat Transfer Porous Media inside a Rectangular Duct atEntrance Region

Authors: Moayed R.Hasan --- SuhadA.Rasheed --- Ali Najeh Mahdi
Journal: Journal of University of Babylon مجلة جامعة بابل ISSN: 19920652 23128135 Year: 2019 Volume: 27 Issue: 1 Pages: 157-210
Publisher: Babylon University جامعة بابل

Loading...
Loading...
Abstract

This work presents experimental investigation of flow and heat transfer characteristics for entry length of turbulent flow in a rectangular duct fitted with porous media and air as the working fluid. Rectangular duct (300×30 mm) with a hydraulic diameter (54.54 mm) was subjected to constant heat flux from lower surface (1.5 ×102 –1.8 ×102w/m2) and Reynolds number ranged (3.3x104 up to 4.8x104). Copper mesh inserts (as porous media) with screen diameter (54.5 mm) for vary distance between two adjacent screens of (10 mm), (15 mm) and (20 mm) in the porosity range of (0.98 - 0.99) are considered for experimentation. The effect of porous height ratio (full and partial) are also considered. It is observed that the enhancement of heat transferby using mesh inserts when compared to a plain surface is more by a factor of (2.2) times where the skin fraction coefficient is about (5) times. An Empiricalcorrelation for Nusselt number and friction factor are developed for the mesh inserts from the obtained results.

يعرض هذا العمل بحثًا تجريبيًا عن خصائص التدفق وانتقال الحرارة في منطقة تطور الجريان عندما يكون الجريان مضطربا في قناة مستطيلة محشوة بوسط مسامي وباستخدام الهواء كمائع عامل. عرضت القناة المستطيلة (300 × 30 مم) مع القطر الهيدروليكي (54.54 ملم) إلى تدفق مستمر للحرارة من السطح السفلي (1.5 × 102 - 1.8 × 102 واط/م2) وتراوحت أرقام رينولدز (3.3 × 104 - 4.8 × 104). تم استخدام شبكة نحاسية بقطر (54.4 ملم) كوسط مسامي ولمسافات مختلفة (15,10و20 ملم)للعمل ضمن مدى المسامية (0.99 الى 0.98). اثناء اجراء التجارب العملية، وتم دراسة تاثير نسبة ارتفاع المسامية (كون التعبئة كاملة وجزئية). كما بينت النتائج العملية ان استخدام الوسط المسامي يحسن انتقال الحرارة بمقدار (2.2) مرة مصحوب بزيادة من معامل الاحتكاك بمقدار (5) مرات.تم استنتاج العلاقات الرياضية لقيم عدد نسلت وعامل الاحتكاك في حالة استخدام الشبكة المسامية من النتائج المستحصل عليها.