research centers


Search results: Found 15

Listing 11 - 15 of 15 << page
of 2
>>
Sort by

Article
Determination of the Biological Kinetics for Diyala River at Al-Rustimiyah WWTP's
حساب محددات الحركة البايولوجية لنهر ديالى مقابل محطات معالجة المياه الثقيلة في الرستمية

Loading...
Loading...
Abstract

Activated sludge process is considered one of the most common and highly effective methods used in aerobically biological treatment systems. The design of such systems is usually based on the biological kinetic approach considerations. The present study is concerned in determining the biological kinetic of the last part of Diyala River at AL-Rustimiyah WWTP's, Baghdad, Iraq. A completely mixed continuous flow lab-scale reactor without recycling was used for this purpose. Various detention times were adopted during the experimental work ranging from 0.723 to 3.809 days. Influent and effluent BOD5, MLVSS and MLSS for the aeration tank, among other tests were performed at different detention times, after reaching the steady state conditions, in order to generate the required data for bio-kinetic coefficients. The biological kinetics k, Y, Kd, and Ks for the last part of Diyala River at AL-Rustimiyah WWTP's were found to be 5.68 d-1, 0.75, 0.06 d-1, and 70 mg/l, respectively. These values were compared with the bio-kinetics of different types of wastes and were found to be within the typical ranges of bio-kinetic parameters for activated sludge process treating domestic wastewater, which indicates that the water at the river reach of interest is rather wastewater than pure river water.

تعتبر طريقة الحمأة المنشطة احدى اهم الطرق واكثرها شيوعا واستخداما في انظمة المعالجات البايولوجية الهوائية, وتصميم هكذا انظمة يأخذ بنظر الاعتبار قيم محددات الحركة البايولوجية للمياه المعالجة. تهتم الدراسة الحالية بحساب قيم محددات الحركة البايولوجية للجزء الاخير من نهر ديالى مقابل محطات معالجة المياه الثقيلة في الرستمية, بغداد, العراق. تم استخدام مفاعل مختبري ذو تصريف مستمر وبدون ارجاع لهذا الغرض,كما وتم اعتماد عدة ازمان للمكوث خلال التجارب العملية تتراوح بين 0.723 و 3.809 يوم. تم اجراء عدة فحوص للمياه الداخلة والخارجة من المفاعل منها: BOD5, MLVSS, MLSS وغيرها. هذه الفحوص تم اجراءها بعد الوصول الى حالة الاستقرار للمفاعل وتم تكرارها لكل زمن مكوث. بالاعتماد على هذه الفحوص, تم استخراج محددات الحركة البايولوجية للجزء الاخير من نهر ديالى لتكون كالتالي: k=5.68d-1, Y=0.75, Kd=0.06d-1, Ks=70mg/l . عند مقارنة النتائج المستحصلة من هذا البحث مع نتائج سابقة لإنواع مختلفة من المخلفات, وجد انها تقع ضمن حدود محددات الحركة البايولوجية لمياه المجاري, مما يدل على ان مياه نهر ديالى في جزءه الاخير هو مياه ثقيلة اكثر مما هو مياه نهر نقية.


Article
Early Prediction Of Toxic Shocks Happening In Activated Sludge Biological Systems
التنبؤ المبكر في حدوث الصدمات السمّية في أنظمة المعالجة البيولوجية التي تعمل بأسلوب الحماة المنشطة

Authors: Ma'an Hashim Mahmood معن هاشم محمود --- Ahmed Y. Shehab أحمد ياسين شهاب --- Riyadh M. Saleh Al- Obaidi رياض محمود صالح
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2010 Volume: 18 Issue: 1 Pages: 26-35
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

Abstract:The shocks became an important issue in operating wastewater treatment plant, because it may lead to biological unit damage in a short time. This study had been done to experience two separated ways in toxic shock happening prediction. Two glass basin (10L volume) used to conduct the study. The work was with completely mixed activated sludge. The studied ways of prediction were 1-the specific oxygen uptake rate (SOUR) of biomass in aeration tank , and 2-microscopic images monitoring. Two types of toxic material were used , the first was phenol (organic) and cyanide (inorganic inhibitors) with 40mg/l concentration in each of the basin separately. The results revealed that the two ways were useful in shock prediction. SOUR has raised with phenol shock in a short time , and has sharp dropped with cyanide shock (about 15 min.). the microscopic images revealed that filamentous growth happened in the bioflocs after short time of phenol shock. While a dispersed growth and pinpoint flocculation has appeared after short time of cyanide shock (leading to the biomass damage).Key words:activated sludge, toxic shock, shocks early predictionالمقدمة

الخلاصة:تُعدّ الصدمات الحاصلة في وحدات الحمأة المنشطة من المشاكل المهمة التي قد تضر بعمل المحطة البايولوجية. لذلك جرى في هذه الدراسة اختبار طريقتين منفصلتين للتنبؤ المبكر بحصول الصدمة. الأولى تتمثل بحساب استهلاك الأوكسجين في الكتلة الحية Specific Oxygen Uptake rate SOUR والثانية تتمثل بمراقبة الصور المجهرية لنماذج من الحمأة المأخوذة من حوض التهوية. وتم العمل مختبرياً باستخدام أحواض زجاجية بحجم 10 لتر (تعمل بأسلوب الحمأة المنشطة- المزج التام) وتسليط نوعين من المواد السمية احدها عضوي (الفينول) والأخر لا عضوي (السيانيد). أثبتت الدراسة بان طريقتي التنبؤ كانتا ناجحتين في الكشف عن مقدمة صدمة إذ حصل تغاير كبير في مؤشر SOUR (تصاعد حاد عند تسليط الفينول وانخفاض حاد عند تسليط السيانايد) في وقت وجيز (15 دقيقة) مما يدل على صلاحية الطريقة في تخمين حدوث صدمة في حوض التهوية. اما الطريقة الصورية فقد اثبت النتائج تغير شكل نمو اللبادات البايولوجية اعتماداً على نوع الصدمة (اذ تحولت من النمو المتكتل الى النمو الخيطي بشكل ملحوظ عند تسليط الفينول والى النمو المتشتت العصوي عند تسليط السيانيد) ذلك بوقت وجيز ايضاً لا يزيد على نصف ساعة. الكلمات الدالة : الحمأة المنشطة، الصدمة السمية، التنبؤ المبكر للصدمات.


Article
Investigate the Effects of F/M, MLSS, and Metal/MLSS Ratio on the Removal of Cd and Pb in the Activated Sludge Units,
تحري تأثير كل من الحمل العضوي وتركيز الحمأة ونسبة تركيز المعدن إلى تركيز الحمأة على إزالة الكادميوم والرصاص في وحدات الحمأة المنشطة

Loading...
Loading...
Abstract

AbstractThe objective of this research is to investigate the effect of each of the average organic load, the mixed liquor suspended solids(MLSS) in aeration tank and the ratio of concentration of metal to the MLSS on removal of cadmium and lead in activated sludge unit. Bench scale unit was used to conduct this study. Four glasses container were used, one for monitoring and others for examination of specific doses of lead and cadmium (5,10,20)mg/l. The capacity of sludge for metal under conditions of study were calculated. Dynamic constant of removal was computed depending on the result of study demonstrated as Frendlich and Langmuir equations, it is clearly shown that the relationship between capacity of sludge for cadmium to organic load is strong at three initial doses while lead was less correlated at the upper initial doses. As a result concentration of metals doesn't affect the removal efficiency of organic material at the range of the organic load used.Keywords: Cadmium, Lead, Activated sludge, Frendlich Equation, Langmuir Equation, Organic load

الخلاصة يهدف البحث إلى تحري تأثير كل من معدل الحمل العضوي وتركيز الحمأة في حوض التهوية ونسبة تركيز المعدن إلى تركيز الحمأة على إزالة الكادميوم والرصاص في وحدة حمأة منشطة ، وقد تم الاعتماد على العمل بالحجم ألمختبري لتحقيق أهداف الدراسة ، وذلك من خلال استخدام أربعة أحواض زجاجية ، احدها للمراقبة والأخرى تم فيها تسليط تراكيز ابتدائية معينة من كل من معدن الرصاص والكادميوم (5، 10، 20) ملغم/لتر، وقد تم احتساب معدلات استيعاب الحمأة للمعدن في ظل ظروف الدراسة، وقد جرى من خلال نتائج الدراسة حساب الثوابت الحركية للإزالة متمثلة بمعادلتي فرندلج ولانكمير كل على حدة ، وقد أظهرت الدراسة ارتباطا قويا بين سعة استيعاب الحمأة للكادميوم على الحمل العضوي بشكل كبير عند التراكيز الابتدائية الثلاثة، بينما للرصاص فقد اظهر اعتمادا قليلا عند التراكيز الابتدائية العليا المسلطة للمعدن ، وأخيرا لم يكن لتركيز المعدن تأثير واضح على كفاءة إزالة المواد العضوية ضمن مدى الحمل العضوي المتبع في هذه الدراسة . الكلمات الدالة : الكادميوم ، الرصاص ، الحمأة المنشطة ، معادلة فرندلج ، معادلة لانكمير ، الحمل العضوي


Article
The Role of Filamentous Bacteria Streptomyces sp. in Reduction of Some Nutrients Concentrations in AL- Restomia Waste water Treatment Plant, Baghdad -Iraq
دور البكتريا الخيطية sp. Streptomyces في خفض مغذيات مياه الصرف الصحي لمحطة الرستمية في مدينة بغداد

Loading...
Loading...
Abstract

The role of filamentous bacteria represented by Streptomycessp was studied as biological treatment for activated sludge AL- Restomia treatment unit in Baghdad city. The result shows reducing in phosphate concentration where apprise in started entrance the treatment unit 12.083 mg/L fast the unit stages reached to 8.426 mg /L where nitrate concentration apprises 3.59 mg/l and ending in 2.43 mg/L The concentration of ammonia apprises 1358 mg/L and reached to 140 mg/L. also the TDS concentration reduced from 1426 to 1203 mg/L where nutrient which represented (SO4, Mg, Ca, Na, K) reduced by range 30.883- 23.337 , 194- 121 , 440- 321 , 109.03- 101.53 and 16.85- 15.4mg/L respectively COD reduce from427.263- 82mg/L with absorbance0.018- 0.027 nm.

درس دور البكتيريا الخيطية sp. Streptomycesضمن الحماة المنشطة لمحطة معالجة الرستمية في مدينة بغداد . بينت النتائج أنخفاضاً في تركيز الفوسفات إذ بلغت في بداية دخولها المنظومة 12.083 ملغم / لتر وبمرورها بمراحل المنظومة وصلت الى 8.426 ملغم /لتر أما النترات فقد كانت 3.59 وانتهت بالتركيز 2.43 ملغم / لتر ، وبلغ تركيز الامونيا من 1358 ملغم /لتر وصولا الى 140 ملغم / لتر ، كما أنخفض TDS من 1426 الى 1203 ملغم / لتر أما الاملاح المتمثلة بالكبريتات ، المغنيسيوم ، الكالسيوم ، الصوديوم ، البوتاسيوم فقد انخفضت من 30.883 الى 23.337 و 194 الى 121 و 440 الى 321 ومن 109.03 الى 101.53 و 16.85 الى 15.4 ملغم / لتر على التوالي ، أما المتطلب الكيميائي للأوكسجين فأنخفض من 427.263 الى 82 ملغم / لتر وبأمتصاصية بلغت 0.018 – 0.027 نانوميتر .


Article
Advance Wastewater Treatment; Biological Removal of Eutrophic Nutrients
المعالجة المتقدمة لمياه الصرف الصحي , الازالة البايولوجية لمغذيات الاثراء الغذائي

Authors: Marwa F. Abed --- Mohammed Y. AL- Ani --- Faris H. Al-Ani
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2015 Volume: 33 Issue: 5 Part (A) Engineering Pages: 1131-1142
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this study, a lab scale different activated sludge configurations methods were used to treat a municipal wastewater from effluent of; primary sedimentation tank of Al-Rustamiya wastewater treatment plant located near Baghdad city to remove organic load, nitrogen and phosphorus from the period of 15 July 2012 to 22 May 2013.Biological treatment systems were conventional activated sludge (CAS) , extended aeration , anaerobic-anoxic-aerobic( A2O) , anoxic-aerobic (MLE) and anaerobic –oxic(A/O). During the operation periods, the average removal efficiency of BOD5, COD and TSS is 81.9, 77.7 and 85.8 respectively regardless of the fluctuation in influent quality. In addition the results show removal efficiency of ammonia, nitrate, nitrite and phosphorus with ranges (61-85.8), (34-81.7) , (35-81.4) (32.3-85.54) % respectively. The biological treatment systems produced high quality effluent which can achieve the Iraqi limitations of rivers maintenance for all measured parameters.

في هذه الدراسة، على نطاقالمختبر تم استخدام تشكيلات أنظمة معالجةحمأة منشطة مختلفة لمعالجة مياه الصرف الصحي البلدية والخارجة من حوض الترسيب الاولي لمحطة معالجة الرستمية الواقعة بالقرب من مدينة بغداد لازالة الاحمال العضوية,النتروجين والفسفور في الفترة من 5 يوليو 2012 الى 22 مايو 2013. انظمة المعالجة البايولوجية هي الحماة المنشطة التقليدية ,التهوية المطولة ,(اللاهوائي –هوائي محدد – هوائي) ,( هوائي محدد – هوائي) و (اللاهوائي - هوائي) .أثناءفترات العمل، فإن متوسط كفاءة الإزالة لكل من الاوكسجين المطلوب حيويا ، الاوكسجين المطلوب كيميائيا والمواد االعالقة الكلية هو81.9، 77.7و 85.8 %على التواليبغض النظر عنالتذبذب فينوعية المياه الواردة. بالإضافةالى ان النتائج تظهر إزالةللأمونيا,النترات ,النتريت والفوسفورضمن مدى(61- 85.8) ,(34-81.7) ,(35-81.4) و (32.3-85.54) %على التوالي.أن أنظمةالمعالجة البيولوجية انتجت نوعيةتصريف خارج بنوعية ممتازة والتييمكن أن تحققحدود المواصفاتالعراقيةلصيانة الانهارو لجميعالمعايير التي تم قياسها.

Listing 11 - 15 of 15 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (15)


Language

Arabic (8)

English (4)

Arabic and English (3)


Year
From To Submit

2018 (1)

2017 (2)

2015 (3)

2014 (1)

2013 (2)

More...