research centers


Search results: Found 15

Listing 11 - 15 of 15 << page
of 2
>>
Sort by

Article
EXPERIMENTAL STUDY FOR BEHAVIOR OF (WASTE CONCRETE FILLED STEEL TUBULER) COLUMNS SUBJECTED TO A STATIC AXIAL LOADS

Author: Zaid Ali Kadhim Alzaidi
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2017 Volume: 10 Issue: 3 Pages: 291-298
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

In this study, composite columns have been tested under axial load. The steel tubes were filled with waste concrete to perform the composite action. The specimens divided into two groups; square and circular columns. The diameter of the circular hallow columns was 7.5 cm with 2mm thickness, while the dimension of the square hallow columns was (7.5 cm × 7.5 cm) with 2mm thickness. For each group a column without waste concrete filled steel tubular (W.C.F.S.T) was tested to act as a reference column. Load-deflection curves were constructed for all specimens. The results indicate that the waste concrete filled steel tube has more capacity due to the composite action. The pattern of failure in circular sections was different from the failure pattern of the square ones.


Article
STRUCTURAL BEHAVIOR OF THIN RPC WALL PANELS WITH VARYING STEEL REINFORCEMENT AND ASPECT RATIO SUBJECTED TO AXIAL ECCENTRIC UNIFORMLY DISTRIBUTED LOADING

Authors: Saad Khalaf Mohaisen --- Layth Abdulbari Al-Jaberi --- Aya Haqi Ismael
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2018 Volume: 22 Issue: 4 Pages: 25-38
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

This paper presents experimental study of structural behavior of thin Reactive Powder Concrete (RPC) wall panels subjected to axial eccentric uniformly distributed loading with varying steel reinforcement ratio (ρ) and aspect ratio (AR= H/L). The experimental program included testing of six two-way thin RPC wall panels, fixed at all sides and applying the load axially with eccentricity equal to (t/6). The results indicates that the ultimate strength of the RPC wall panel decreases with increase in AR from (1.25 to 2.00) for panels with H/t = 18.75. The decreasing in ultimate load for RPC wall panels is about 16% and 38.7%, for an increase in AR from 1.25 to 2.0 for panels with ρ = 0.012566, and about 6.38% and 36.2%, for an increase in AR from 1.25 to 2.0 for panels with ρ = 0.007854.The ultimate strength of RPC wall panel increases with an increase of percentage of steel reinforcement ratio (ρ). For an increase in reinforcement ratio from ρ = 0.007854 to ρ = 0.012566 the increase is about (6.4, 4.76 and 2.22) % for walls with AR (1.25, 1.50 and 2.00) respectively. The lateral deflection decrease with the increase of percentage of steel reinforcement ratio from (0.007854 to 0.012566) under two-way in plane loading, When AR= 1.25 the reduction about (1.22 times) and When AR= 2.00 the reduction about (1.11 times). The lateral deflection of RPC wall panels decrease with the increase in aspect ratio.


Article
Effct of Hoops and Column Axial Load on Shear Strength of High-Strength Fiber Reinforced Beam-Column Joints
تاثير الأطواق وحمل العمود المحوري على مقاومة القص لمفصل العتبة-العمود المصنّع من خرسانة عالية المقاومة والمسلحة بالألياف

Authors: Zaid M. Kani --- Jamal A. Farhan
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2012 Volume: 18 Issue: 3 Pages: 350-363
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A reinforced concrete frame is referred as "RIGID FRAMES". However, researches indicate that the Beam-Column joint (BCJ) is definitely not rigid. In addition, extensive research shows that failure may occur at the joint instead of in the beam or the column. Joint failure is known to be a catastrophic type which is difficult to repair.This study was carried out to investigate the effect of hoops and column axial load on the shear strength of high-strength fiber reinforced Beam-Column Joints by using a numerical model based on finite element method using computer program ANSYS (Version 11.0). The variables are: diameter of hoops and magnitude of column axial load.The theoretical results obtained from ANSYS program are in a good agreement with previous experimental results.

يطلق على الهياكل في المنشات الخرسانية المسلحة مصطلح " الهياكل الجاسئة ". في حين أظهرت البحوث بشكل جلي أن مفصل العتبة-عمود ليس جاسئا. بالاضافة الى ذلك فان البحوث المكثفة اوضحت أن الفشل قد يحدث في المفصل بدلا من العمود أو العتبة وهذا النوع من الفشل يصعب أعادة تأهيله. في هذه الدراسة تمت دراسة تأثير الاطواق والحمل المحوري للعمود على مقاومة مفاصل عمود- عتبة عالية المقاومة ومسلحة بالالياف باستخدام نموذج عددي باعتماد طريقة العناصر المحددة وباستخدام برنامج (ANSYS) الاصدار الحادي عشر. وقد كانت المتغيرات قطر قضيب الطوق, مقدار الحمل المحوري. لقد أظهرت النتائج المستحصلة من برنامج (ANSYS) والنتائج العملية من بحوث سابقة توافقا جيدا.


Article
EXPERIMENTAL STUDY ON STRUCTURAL BEHAVIOR OF THIN WALL CONCRETE PANELS SUBJECTED TO AXIAL ECCENTRIC UNIFORMLY DISTRIBUTED LOADING
دراسة السلوك الإنشائي للألواح الجدارية الخرسانية النحيفة المعرضة الى تحميل محوري لامركزي منتشر

Authors: Aya Haqi Ismael --- Layth A. Al-Jaberi --- Saad Khalaf Mohaisen
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2017 Volume: 21 Issue: 1 Pages: 51-64
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Due to the current popularity of reinforced concrete (RC) wall construction, and the new published of codes of concrete, RC walls have become just as an important structural elements as beam, slabs and columns. This paper presents an experimental study of structural behavior of thin concrete wall panels subjected to axial eccentric uniformly distributed loading with varying aspect ratio (AR=H/L) and concrete type (concrete strength (f 'c)). The experimental program included testing of six two-way thin concrete wall panels, fixed at all sides and applying the load axially with eccentricity equal to wall thickness/6).The results indicate that the load carrying capacity of the normal strength concrete (NSC) wall panels decreased with the increase in AR (H/L) from 1.25 to 2.00, the ultimate load reduced from 37.5% to 14.6 % when AR decreased from 2.00 to 1.25. For Reactive Powder Concrete (RPC), the ultimate load reduced from 38.7% to 16% when AR decreased from 2.00 to 1.25. The strength of the concrete wall increases with the increase in concrete strength (f 'c) from 33.5 MPa to 120.4 MPa , the increase is about (212.5, 207.3, 206.67) % for panels with H/L = (1.25, 1.50, 2.00) respectively. The lateral deflections of concrete wall panels depend on the aspect ratio (H/L) where, the increase in aspect ratio (H/L) from 1.25 to 2.00 of NSC panels causes increasing the lateral deflection of the concrete wall panels, while for Reactive Powder Concrete (RPC) wall panels the increase in aspect ratio (H/L) from 1.25 to 2.00 causes decreasing in the lateral deflection of the concrete wall panels. Also the lateral deflection depends on concrete type (concrete strength (f 'c)), when strength of the concrete wall panel increases from 33.5 to 120.4 MPa, the lateral deflection decreases.

نظرا للانتشار الأخير للبناء بالجدران الخرسانية المسلحة, والمدونات الجديدة الأميركية المنشورة لمعهد الخرسانة الأميركي ACI-Code, أصبحت الجدران الخرسانية عنصر انشائي هام مثل العتبات، والسقوف والأعمدة. هذا البحث يقدم دراسة للسلوك الانشائي للألواح الجدارية الخرسانية النحيفة المعرضة الى تحميل محوري لامركزي موزع بانتظام مع نسب مختلفة من نسبة الارتفاع على العرض(Aspect Ratio) ونوعية الخرسانة ( مقاومة الخرسانة (f 'c)). البرنامج يتضمن فحص ستة نماذج من الألواح الجدارية (two-way action) الخرسانية النحيفة المثبتة بكل الجوانب وتسليط الحمل محوريا مع لا مركزية مساويه الى السمك مقسم على ستة (t/6). النتائج تشير إلى أن مقاومة الجدران الخرسانية (مقاومة الحمل العمودي) ذات المقاومة الاعتيادية تقل مع الزيادة في نسبة الارتفاع على العرض (H/L) من (1.25 الى 2.00), ), الحمل الاقصى انخفض من 37.5٪ إلى 14.6٪ عندما انخفضت نسبة (H/L) من 2.00 الى 1.25. ولجدران خرسانة المساحيق الفعالة (RPC)، الحمل الاقصى انخفض من 38.7٪ إلى 16٪ عندما انخفضت نسبة (H/L) من 2.00 الى 1.25. المقاومة للجدران الخرسانية تزداد مع الزيادة في مقاومة الخرسانة للانضغاط (f 'c) من 33.5 (MPa) إلى 120.4 (MPa). كانت الزيادة (212.5، 207.3، 206.67) ٪ للجدران مع H/L = (1.25 ، 1.50، 2.00) على التوالي. الازاحة الجانبية للألواح الجدارية الخرسانية يعتمد على نسبة الارتفاع على العرض (H/L) حيث أن الزيادة في نسبة الارتفاع على العرض (H/L) من 1.25 الى 2.00 لجدران المقاومة الاعتيادية (NSC) يسبب زيادة الازاحة الجانبية للألواح الجدارية الخرسانية، في حين أن جدران خرسانة المساحيق الفعالة RPC)) الزيادة في نسبة الارتفاع على العرض من 1.25 الى 2.00 يسبب تناقص في الازاحة الجانبية للألواح الجدارية الخرسانية. الازاحة الجانبية يعتمد أيضا على نوع الخرسانة (مقاومة الخرسانة للانضغاط (f 'c))، عندما تزداد مقاومة الخرسانة من (33.5 الى 120.4) (MPa)، يقلل من الازاحة الجانبية.


Article
Behavior of Reinforced Concrete Columns Subjected to Axial Load and Cyclic Lateral Load
سلوك الاعمدة الخرسانية المسلحة المعرضة لحمل محوري مع حمل جانبي ترددي

Authors: Akram Ghulam Awazli أكـرم غـلام عـوازلي --- Rafaa Mahmood Abbas رافع محمود عباس
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2017 Volume: 23 Issue: 2 Pages: 21-40
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Columns subjected to pure axial load rarely exist in practice. Reinforced concrete columns are usually subjected to combination of axial and lateral actions and deformations, caused by spatially‐complex loading patterns as during earthquakes causes lateral deflection that in turn affects the horizontal stiffness. In this study, a numerical model was developed in three-dimensional nonlinear finite element and then validated against experimental results reported in the literatures, to investigate the behavior of conventionally RC columns subjected to axial load and lateral reversal cyclic loading. To achieve this goal, numerical analysis was conducted by using finite element program ABAQUS/Explicit. The variables considered in this study were axial load index, concrete compressive strength, column aspect ratio, longitudinal and transverse reinforcement ratios. According to numerical case studies, the results revealed that axial load index and longitudinal reinforcement ratio have the most impact on the column response. Also, increasing concrete compressive strength and reducing column aspect ratio resulted in increasing strength capacity of the column. Moreover, increasing lateral confinement by transverse reinforcement at the column ends increases the flexural strength of a flexure-controlled RC columns.

ان الأعمدةُ المعرضة إلى حملِ محوريِ فقط قليلة جدا في الواقع العملي. حيث تتعرض الأعمدة الخرسانية المسلحة في الاغلب إلى تأثيرات تضم قوى محورية وجانبية والى تشوهاتِ، سببها أنماط تحميل معقدة في الفضاء (ثلاثية الابعاد) اثناء زلزال مثلا، مُسَبِّبة الازاحة الجانبية التي تُؤثّرُ بدورها على الجسائة الأفقية. في هذه الدراسة، تم تطويرُ نموذجَ لا خطّي ثلاثي الأبعادِ من نماذجِ العناصرِ المحدودةِ ِ ومن ثم التثَبَّتَ من صحة النتائج بالمقارنة مع النتائج التجريبية المثبتة بأدبيات البحوث، للتعرف على سلوك الاعمدة الخرسانية المسلحة الشائعة المعرضة لأحمال محورية وجانبية عكسية ترددية. ولتحقيق الهدف، اجري التحليل العددي باستخدام طريقة العناصر المحددة بواسطة برنامج ABAQUS/Explicit. المتغيرات التي تم دراستها في هذا البحث هي مؤشر الحمل المحوري، قوة انضغاط الخرسانة، ونسبة الارتفاع الى العرض، ونسبة التسليح الطولي والعرضي. وفقا للدراسة العددية، اظهرت النتائج ان مؤشر الاحمال المحورية ونسبة التسليح الطولي لهما التأثير الاهم على استجابة العمود. كما ان زيادة قوة انضغاط الخرسانة اوتقليل نسبة الارتفاع الى العرض للاعمدة فأن ذلك يؤدي الى زيادة في قدرة مقاومة العمود. بالاضافة لذلك ان زيادة الحصر الجانبي بواسطة التسليح المستعرض في نهايات العمود يؤدي لزيادة مقاومة الانثناء للاعمدة التي يغلب عليها فشل الانثناء.

Listing 11 - 15 of 15 << page
of 2
>>
Sort by
Narrow your search

Resource type

article (15)


Language

English (14)

Arabic (1)


Year
From To Submit

2019 (2)

2018 (1)

2017 (5)

2016 (1)

2014 (1)

More...