Design And Implementation Of A Biomedical Signals Generator Based On Microcontroller
تصميم وتنفيذ مولد أشارات حيوية بالاعتماد على المسيطر الدقيق

Loading...
Loading...
Abstract

Biomedical signals are one of the most important parameters in the diagnosis, so the doctors and clinical trainers must be familiar with these signals. Biomedical signals generator is an electronic device used to simulate such signals for the above mentioned purpose. The biomedical signals generator (BIO-SG) is a useful tool for biomedical signals devices for calibration , monitoring and incorporate in educational tasks and clinical environments. a biomedical signals generator based on microcontroller and also we use a digital to analog convertor and an amplifier to act as a conditioning circuit for the signal and made it easy to show on an oscilloscope. The device is based on a microcontroller to generate the basic ECG wave and EMG wave, these signals can used as an input to the ECG and EMG machines. the results shows that the generated waves with low error rate compared with the biomedical standard waves.

الإشارات الطبية الحيوية هي واحدة من أهم المعايير في التشخيص، وبالتالي فإن الأطباء والمدربين السريرين يجب أن يكونوا على دراية مع هذه الإشارات. مولد الإشارات الطبية الحيوية هو جهاز إلكتروني يستخدم لمحاكاة مثل هذه الإشارات لغرض المذكورة وهو أداة مفيدة للأجهزة الطبية الحيوية لرصد إشاراتها للمعايرة وتدرج في المهام التعليمية والبيئات السريرية. مولد الإشارات الطبية الحيوية يعتمد على متحكم وأيضا نستخدم المحول الرقمي التناظري إلى ومكبر للإشارات ليكون بمثابة دائرة تكييف للإشارة، وجعل من السهل أن تظهر على راسم الذبذبات. ويستند الجهاز على متحكم ليولد الأساسية ECG موجة وموجة EMG، يمكن استخدام هذه الإشارات كمدخل للآلات ECG وEMG. النتائج تظهر أن الموجات المتولدة مع نسبة الخطأ منخفضة مقارنة مع مستوى موجات الطبية الحيوية القياسية.


Article
ECG Arrhythmias Classification by Combined Feature Extraction Method and Neural Network
تصنيف عدم الانتظام بإشاره قلب الانسان باستخدام أسلوب مركب والشبكه العصبونيه

Author: Khalooq Y. Al Azzawi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 3 Part (A) Engineering Pages: 586-596
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

Electrocardiogram (ECG) became one of the most crucial tool for heart status diagnosis. Generally, several arrhythmias may appear based on different heart rate or ECG signal morphology variation. In this paper, a novel combined feature extraction method to present ECG arrhythmias is proposed. The combination between Wavelet Packet Transform (WPT) entropies and Power Spectrum Density (PSD) is suggested. For classification, Feed Forward Backpropagation Neural Network (FFBPN) is utilized. The experimental results showed that the proposed method can be beneficial for ECG signal arrhythmias classification. MIT-BIH Arrhythmia Database was used for algorithm testing. The proposed method was compared with three state of art methods, where was of better performance reached about 80%. The proposed method as well as other methods was tested in noisy environment for comparison investigations. The suggested method is promising approach for arrhythmias classification. However, enormous testing data set might significantly improve the results.

إشارة تخطيط القلب أصبحت واحدة من أكثر الأدوات الحاسمة في تحليل حالة القلب بشكل عام . قد تظهرمعالم للعديد من عدم إنتظام ضربات القلب بناء على معدل ضربات القلب المختلفةأو شكل إشارة تخطيط القلب .في هذا البحث تم إقتراح طريقة لأستخراج الملامح ( Feature Extraction Method) لعدم انتظام ضربات القلب . وقد جمع بين الإنتروبيا لتحويلة المويجات وكثافة طيف الطاقة لغرض التصنيف,حيث أظهرت النتائج التجريبية أن الطريقة المقترحة يمكن أن تكون مفيدة لتمييز حالات عدم انتظام ضربات القلب, حيث تم استخدام قاعدة بيانات معهد ماساتشوستس للتكنولوجيا لأختبار الخوارزمية , وقد تم الحصول على أداء أفضل من الأساليب الاعتيادية بحصوله على النسبة 80%.

Keywords

ECG --- Wavelet --- PSD --- Arrhythmia. FFBPN


Article
Stress Detection Based on ECG Using Discrete Wavelet Transform
الكشف عن الإجهاد معتمداً على إشارةECG باستخدام محول المويجات المتقطع DWT

Authors: Mousa Kadhim Wali موسى كاظم والي --- Nabil K.AL-Shamma نبيل كاظم رؤوف الشماع --- Qais M.Ali Al-hakarchi قيس محمد علي الشكرجي
Journal: Al-Ma'mon College Journal مجلة كلية المامون ISSN: 19924453 Year: 2014 Issue: 23 Pages: 290-306
Publisher: AlMamon University College كلية المامون الجامعة

Loading...
Loading...
Abstract

Acute stress is the most common form of stress. It comes from demands and pressures of the recent past and anticipated demands and pressures of the near future. This research studied the stress on female students due to mathematical exercises in a noisy environment. Detection of this stress is important because it contributes to diverse pathophysiological changes including sudden death, ischemic diseases (myocardial infarction, angina), and wall motion abnormalities (the motion of a region of the heart muscle is abnormal), as well as to alterations in cardiac regulation as indexed by changes in sympathetic nervous system activity and hemostasis (process which causes bleeding to stop in order to keep blood within a damaged blood vessel unlike hemorrhage). Stress level is difficult to manage because it cannot be measured in a consistent and timely way. One current method to characterize an individual’s stress level is to conduct an interview or to administer a questionnaire during a visit with a physician or psychologist. HRV (Heart rate variability) can be analyzed using both time domain and frequency domain features. Selection of features which vary with the changes of the stress levels is significant and it is important to show relatively reliable behavior. Overall, heart rate variability spectra during baseline conditions related to Left ventricular hypertrophy and congestive heart failure are dominated by high frequency activity. Stress is accompanied by an increase in the Power Spectrum Density (PSD) of Low Frequency (LF) and decrease in PSD of High Frequency (HF). Data (ECG signal) was collected by AD (Data acquisition) Instrument from ten female subjects, in the age range of 20 to 24 years were of asked to perform three levels difficulties of arithmetic tasks. A total of ten statistical features were used in this research extracted through wavelet transform, including: Mean, Maximum, Minimum, Standard deviation, Variance, Mode, Median, power spectral density (PSD), energy, entropy and hybrid of them. The SVM (support vector machines) classifier give highest accuracy of 79.5 based on hybrid feature and ribo 3.7 wavelet through LF range.

يعد الإجهاد الحاد هو اكثر أنواع الإجهاد شيوعاً ويحصل من الضغوطات والاحتياجات ألحاليه والمستقبلية.تم في هذا البحث دراسة الإجهاد على ألطالبات نتيجة حل ألمسائل الرياضية في أجواء صاخبة. الكشف عن الإجهاد مهم لأنه يسهم في تطور التغيرات المرضية في جسم المريض المتنوعة بما في ذلك الموت المفاجئ، نقص ألترويه ألمؤدي الى أما احتشاء عضلة القلب أو الذبحة ألصدريه ، الحركات غير الطبيعية لجدار القلب (لمنطقه في عضلة ألقلب) ، فضلا عن التغييرات في تنظيم حركة القلب التي تسببها التغيرات في نشاط الجهاز العصبي الودي والأرقاء. مستوى الإجهاد من الصعب تحديده لأنه لا يمكن قياسه بطريقة متناسقة وفي الوقت المناسب. أسلوب واحد مستخدم لتوصيف مستوى إجهاد الفرد هو أجراء مقابلة أو تحليل بيانات محدده تؤخذ خلال زيارة الطبيب أو الطبيب النفساني.معدل تغير ضربات القلب HRV يمكن تحليله بدراسة التغيرات الحاصلة بالتردد لفترة زمنيه محدده باستخدام طريقة time domain and frequency domain. تحليل البيانات المتغيرة التي يمكن ملاحظتها في مستويات التوتر المختلفة مهم في تحديد العلاج المناسب. وعموما، يهيمن على معدل ضربات القلب تقلب أطياف الترددات العالية لخط الأساس المتعلق بالبطين الأيمن وفشل ألقلب . الإجهاد يصاحبه زيادة في كثافة القدرة (PSD) للترددات المنخفضة (LF) ويقابله انخفاض في كثافة القدرة للترددات العالية . (HF) بيانات إشارة الراسم القلبي (ECG) تم جمعها من قبل جهاز تجميع البيانات أخذت من عشر أناث من الفئة العمرية من 20 إلى 24 سنة تم تعريضهن لثلاثة مستويات من صعوبات المسائل الرياضية الحسابية. تم استخدام ما مجموعه عشر نتائج احصائية في هذا البحث أخذت عن طريق تحويل المويجات، بما في ذلك : الحدود المتوسطة ، الحدود العليا ، الحدود الدنيا ، ومعدل الانحراف المعياري ، التباين، الواسطة، والمتوسط، وكثافة القدرة (PSD)، والطاقة، مقياس الطاقة الهجين. المصنف SVM يعطي أعلى دقة 79.5 على أساس الميزة HYPRID و 3.7 للمويجات نوع RIBO من خلال مجموعة الترددات الواطئة LF .

Keywords

Stress --- ECG --- SVM --- KNN --- DWT


Article
ECG Changes After Alteplase Therapy in Patients with Acute Myocardial Infarction

Author: Zaid A.MustafaAl-Najjar* ,Zahraa H.Ismaeel**, Amar Zedan Omran
Journal: Iraqi Academic Scientific Journal المجلة العراقية للاختصاصات الطبية ISSN: 16088360 Year: 2016 Volume: 15 Issue: 2 Pages: 158-162
Publisher: The Iraqi Borad for Medical Specialization المجلس العراقي للاختصاصات الطبية

Loading...
Loading...
Abstract

ABSTRACT:BACKGROUND: Acute myocardial infarction is a major cause of death throughout the world. Many important advances have become available to Coronary Care Units enabling them to reduce mortality and improve the prognosis, Reperfusion therapy is one of these important advances. OBJECTIVE: This study sought to identify the Electro-cardiographic (ECG ) changes which occur after receiving Alteplase therapy and its relation to response to thrombolytic therapy. METHODS : Seventy-three patients with ST- elevation Acute Myocardial Infarction (AM I) who received Alteplase within 12 hours from the start of symptoms in coronary care unit were included in this study. Electro-cardiographic (ECG) was done to all patients at time of arrival to the coronary care unit(CCU), Alteplase therapy was given to all patients plus heparin intravenously, followed by electro-cardiographic (ECG ) every 30 minutes for 2 hours.RESULTS:Fifty-seven and half percent of our patients showed 50% reduction in the ST segment elevation in the worst lead after 2 hours from starting Alteplase therapy and regarded as responders. Other ECG changes like rapid appearance of Q wave, T inversion, accelerated idioventricular rhythm (AIVR) are found to be specific for reperfusion with a high predictive value when the gold standard criteria was reduction 50 % in the ST segment elevation Resolution of reciprocal changes is sensitive and specific with high predictive value. CONCLUSION :Some ECG changes after thrombolytic therapy can predict the response in addition to the already known changes. .


Article
Ventricular ectopic beats in structurally normal heart: When to stop investigations
دقات خارج الرحم البطيني في القلب الطبيعي هيكليا: متى لوقف التحقيقات

Author: Sabah Z. Zangana
Journal: Zanco Journal of Medical Sciences مجلة زانكو للعلوم الطبية ISSN: 19955588/19955596 Year: 2015 Volume: 19 Issue: 1 Pages: 910-914
Publisher: Hawler Medical Univeristy جامعة هولير الطبية

Loading...
Loading...
Abstract

Background & Objectives: Ventricular ectopic beats (extra systoles, premature beats) are frequently found in healthy people. Ectopic beats in patients without apparent heart disease are more prominent at rest and disappear with exercise. Treatment is not necessary unless the patient is highly symptomatic. Methods: Patients having ventricular ectopic beats were assessed clinically, by ECG and by echocardiography. Those with normal structure hearts underwent exercise ECG and among those we selected 50 patients whose ectopics were suppressed by exercise then followed them for 5 years. The study started from 2000 to 2010. Results: During 5-year follow-up of the above mentioned patients, relevant complications such as dangerous ventricular arrhythmias, ischemic heart diseases or heart failure were not recorded. Conclusions: In patients having ventricular ectopic beats and structurally normal heart, the suppressibilty of the ectopic by exercise indicated their benign origin and may preclude further invasive investigations and even specific treatment.

Keywords

Heart --- Arrhythmia --- Ectopic --- ECG --- Kirkuk


Article
Two years experience in pacemaker implantation in AL-Kadhemia university hospital and review of its indications and related early complications.
سنتا خبرة في زرع النابض الكهربائي القلبي في مستشفى الكاظمية الجامعي وتبيان دواعي الزرع ومضاعفاته الأولية

Author: Majid abd-AL-Amee
Journal: KUFA MEDICAL JOURNAL مجلة الكوفة الطبية ISSN: 1993517X Year: 2008 Volume: 11 Issue: 2 Pages: 114-126
Publisher: University of Kufa جامعة الكوفة

Loading...
Loading...
Abstract

ABSTRACTBackground: More than 400000 pacemakers are implanted each year. Subclavian vein is accessed by Seldinger technique This procedure is accomplished in catheterization laboratory or x-ray room, under local anesthesia;. Generally patients stay in hospital for one night. Aim of study: To register 2 years experience of Pace maker (PM.) implantation in Al-Kadhimiah University hospital in 290 patients, emphasizing its indications and related complications. Patients and methods: 290pat. had been retrospectively reviewed for 302 implanted PM. devices, mainly due to Complete heart Block( CHB) with wide QRS. (180 pat.). 302 PM. devices were implantedn AL-Kadhemiah university hospital by an experienced medical team, supervised by Prof. Dr. Ammar Al- Hamdi in a period of 2 year, from 82003-82005. Results: 170 of them were males (mean age 75 years); the remaining 120 pat. were females (mean age: 62 years). Their main chief complaint was syncope (135 pat.) , and dizzy spells (81 pat). Their main Echo. findings were dilated LV. (18 pat.), dilated LA. (32 pat.), and LV. wall hypokinesia (15 pat.). The main indication for implantation was CHB. (221), and SND. (45). The main implanted mode was DDD. (228) and VVI. (45). Temporary PM. has been indicated in 62 pat. presented with bradycardia with ventricular rate ≤30 bpm. (including 2 emergency procedures). Ambulatory Holter monitoring was useful in approaching recurrent unexplained syncope in 48 pat, especially to document atrial- tachycardia, sinus pauses, and to exclude ventricular arrhythmia. EPS. was helpful in approaching 4 pat. with unexplained recurrent syncope (with nondiagnostic Holter). Main and serious complication was pocket –related infection (13), 12 of their lead systems and boxe had been successfully removed by cautious gradually increasing pulling force under fluoroscopy. 5 old pacing systems were smoothly extracted due to End Of Life (EOL) of SorinTM, and new systems were reimplanted, but 2 lead coils were cut with ligation of insulating part. 3 procedures were early complicated by hematoma, managed by simple needle aspiration. System upgrading was performed in 4 SorinTM reimplanted systems (from VVI. to DDD.) Conclusions: Temporary PM. implantation is not essential, except in those presenting with ventricular rate ≤30 bpm. 24 hour ambulatory ECG. monitoring is of paramount importance in approaching pat. with recurrent unexplained syncope, especially in suspected Sinus Node Dysfunction (SND).. Diabetes mellitus(DM.) was the main pat. - related risk factor to PM. infection.

الخلاصة تمهيد:يزرع أكثر من4000 نابض سنويا في العالم , وتتم هذه العملية في مختبر القسطرة أو في غرفة الأشعة السينية, تحت التخدير الموضعي. ويدخل إلى الوريد تحت الترقوي بطريقة سلدنجر.ويبقى المريض في المستشفى ليلة واحدة بعدها. الأهداف: لتوثيق سنتين من الخبرة في زراعة النابض الكهربائي في م. الكاظمية الجامعي ل 290 مريضا,موضحا دواعي الزرع والمضاعفات الأولية. الطرق: درست حالات 290 مريضا (رجعيا)زرع فيهم 302 نابضا, لداعي انحصار الحزمة القلبية الكامل خاصة مع توسع في QRS.(عند180 مريضا). زرع هذه النوابض فريق طبي متخصص بإشراف الأستاذ الدكتورعمار الحمدى من الفترة 82003-8 2005. النتائج: 170 مريضا كانوا رجالا(معدل أعمارهم 75 سنة)؛والمتبقىمنهم0120 مريضا) كن نساء(ومعدل اعمارهن62 سنة).وكان العرض الشائع هو فقدان الوعي المؤقت(135 مريضا),ونوبات من الدوخة(81 مريضا).وأشار فحص الصدى القلبي غالبا إلى توسع البطين الأيسر (18 مريضا), وتوسع الأذين الأيسر(32 مريضا),وقلة حركة احد الجدر للبطين الأيسر(15 مريضا). وكان أهم دواعي الزرع هو انحصار الحزمة القلبية الكامل(عند221 منهم),ومرض العقدة الجيبية(عند45 منهم).أكثر صنفين زرعا هما DDD(228 مريضا),وVVI (45 منهم).زرع نابض مؤقت ل 62 مريض عانوا من بطئ النبض(>30 ن.ف.د),من ضمنهم حالتان طارئتان.استفيد من نظام هولتر لتخطيط القلب المتحرك في مقاربة48 مريضا كان يعانى من حالات متكررة وغير مفسرة لفقدان الوعي المؤقت,ولتوثيق حالات التسارع الاذينى ,والتوقف الجيبى ,ولإسقاط احتمالية التسارع البطينى.كذلك,ساعد جهاز فحص الكهربائية الفسلجية في مقاربة 4 مرضى عانوا من حالات متكررة وغير مفسرة لفقدان الوعي المؤقت( إن كان فحص الهولتر سلبيا).إن أهم واخطر المضاعفات كان التهاب الجيب الجراحي (عند 13 مريضا), أزيل 12 صندوقا مع هواديه بنجاح بواسطة قوة ساحبة تزداد تدريجيا وبحذر وبمراقبة المنظار الوهجى.وأزيل بسلاسة 5 نوابض قديمة (من نوع سورين) لانتهاء بطاريتها,وزرعت نوابض بديلة لهم,لكن قطع عمدا هاديين مع تثبيت الأجزاء العازلة.ثلاث حالات تبعتها تجمع دموي كمضاعفات أولية ,عولج تحفظيا بالسحب الابرى.أجريت 4 ترقيات للصنف (لنوع سورين) منVVI إلى DDD.

Keywords

Syncope --- Bradycardia --- ECG. --- Holter --- PM. --- Indications --- Complications


Article
Reproductive performance improvement in primiparous lactating Holstein cows by different hormonal treatments
تحسين ألاداء التناسلي في أبقار الهولشتاين الحلوب احادية الولادة بعلاجات هرمونية مختلفة

Author: T. M. Al-Hamedawi طالب موسى عبد الله الحميداوي
Journal: Iraqi Journal of Veterinary Sciences المجلة العراقية للعلوم البيطرية ISSN: 16073894 Year: 2012 Volume: 26 Issue: 2 Pages: 85-87
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

This study was aimed to evaluate different hormonal treatments during early postpartum period on reproductive efficiency on 42 primiparous Holstein cows in the experimental farm of college of Agriculture, University of Baghdad, aged 3-3.2 y. during the period from 2010-2012. These cows were divided randomly into four groups according to hormonal treatment at day 50 postpartum. The 1st group included 11 cows and was injected with GnRH 0.0126mg/IM, the 2nd group (10 cows) injected with eCG 1000 IU/IM, the 3rd group (11 cows) administrated by hCG 1500 IU/IM and the 4th group (10 cows) without treatment as a control group. The results of this study revealed that the responsive cows (estrus behaviors) were 10 (90.9%), 8 (80%), 9 (81.8%) and 9 (90%) in the 1st, 2nd, 3rd and 4th group respectively and these results were recorded superior significant (P<0.01) for group 2 compared with group 1 and 3 related with duration from initiation of estrus, but no significant differences (P<0.01) between all groups about services per conception and number of conceived animal while the days open and calving interval was recorded significant differences (P<0.01) between the 1st, 2nd and 3rd groups compared with control group (4th group). It could be concluded that using hormonal treatment which indicated to produce improvement in certain parameters of reproductive performance provided early post partum breeding.

لقد استهدفت الدراسة تاثيراستخدام انظمة علاجية هرمونية مختلفة خلال الفترة المبكرة بعد الولادة على الكفاءة التناسلية على 42 بقرة هولشتاين حلوب احادية الولادة في الحقل الحيواني التجريبي التابع لكلية الزراعة/ جامعة بغداد وتراوحت اعمارها بين 3-3,2 سنة وذلك خلال الفترة من 2010-2012. وقد قسمت هذه الابقار عشوائيا الى اربعة مجاميع طبقا لنوع التعامل الهرموني لها. وضمت المجموعة الولى 11 بقرة وقد حقنت بهرمون ال GnRH وبجرعة 0,0126 ملغم في العضلة أما المجموعة الثانية (10 أبقار) فتم حقنها ب 1000 وحدة دولية من هرمون eCG فيما حقنت المجموعة الثالثة بـ 1500 وحدة دولية من هرمون hCG وكان عددها 11 بقرة، اما المجموعة الرابعة والتي مثلت مجموعة السيطرة فقد ضمت 10 أبقار ولم تتم معاملتها بأي معاملة هرمونية. كانت نسب الاستجابة (ظهور الصراف) للعلاج 90,9%، 80% و 81,8% للمجاميع الأولى والثانية والثالثة على التوالي بينما أظهر الشبق بنسبة 90% بالنسبة للمجموعة الرابعة ولكن بعد فترة 48 يوم من بدء المعاملة للمجاميع الاخرى، أما فترة الاستجابة فكانت قد سجلت فارق معنوي بمستوى (P<0.01) لصالح المجموعة الثانية مقارنة مع المجاميع الاخرى وكذلك اتضح الفارق الكبير بين المجاميع المعاملة هرمونيا مع مجموعة السيطرة. أما المقاييس التناسلية الاخرى فقد حصلنا على عدم وجود فارق معنوي بين المجاميع فيما يخص عدد التلقيحات اللازمة للحمل ولكن سجل فارق معنوي بمستوى (P<0.01) لصالح المجاميع الثلاثة الاولى مقارنة مع مجموعة السيطرة وعليه فقد تم الاستنتاج من هذه الدراسة بانه يمكن تحسين الاداء التناسلي لهذه الابقار وبفترة مبكرة باستخدام معاملات هرمونية عما عليه لو تركت بدون تداخل.

Keywords

Holstein --- Reproductive performance --- GnRH --- hCG --- eCG.


Article
Classification of Cardiac Arrhythmia using ID3 Classifier Based on Wavelet Transform
تصنيف الاضطرابات القلبية بأستخدام المصنف ID3 وتحليل المويجة

Authors: Ahmed T. Sadiq احمد طارق صادق --- Nidhal H. Shukr نضال حميد شكر
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2013 Volume: 54 Issue: 5 Pages: 1167-1175
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

Accurate detection of Electro Cardio Graphic (ECG) features is an important demand for medical purposes, therefore an accurate algorithm is required to detect these features. This paper proposes an approach to classify the cardiac arrhythmia from a normal ECG signal based on wavelet decomposition and ID3 classification algorithm. First, ECG signals are denoised using the Discrete Wavelet Transform (DWT) and the second step is extract the ECG features from the processed signal. Interactive Dichotomizer 3 (ID3) algorithm is applied to classify the different arrhythmias including normal case. Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) Arrhythmia Database is used to evaluate the ID3 algorithm. The experimental result shows that the accuracy of ID3 is 92% in the case of Haar transform and 94% with Daubeshies4 transform.

في الاغراض الطبية يكون الكشف الدقيق لخصائص الاشارة القلبية (ECG) مطلبا مهما لذلك نحتاج الى خوارزمية دقيقة لكشف تلك الخواص. في هذا البحث, في هذا البحث تم اقتراح نهج لكشف وتصنيف الاضطرابات القلبية بالاعتماد على تحليل المويجات. في الخطوة الاولى تم تقليل الضوضاء في الاشارة بأستخدام تحليل المويجات المتقطع (DWT) وفي الخطوة الثانية تم استخلاص الخصائص من الاشارة القلبية ثم طبقنا خوارزمية ID3 لتصنيف مختلف الاضطرابات القلبية مع الحالة الطبيعية للقلب. لتعليم واختبار الخوارزمية تمت الاستفادة من قاعدة البيانات MIT-BIH وللحصول على الاشارات الخاصة بالاضطرابات القلبية. ان النتائج العملية تبين ان دقة تصنيف الخوارزمية هو 92% عند استخدام تحويل Harr و94% بأستخدام تحويل Duabechies4.


Article
The Relationship between P-Wave Morphology and Atrial Fibrillation

Authors: Ziad T. Al-Dahan --- Abbas. F.Al-Hashimi --- Natiq. A. Al-Asady
Journal: AL-NAHRAIN JOURNAL FOR ENGINEERING SCIENCES مجلة النهرين للعلوم الهندسية ISSN: 25219154 / eISSN 25219162 Year: 2017 Volume: 20 Issue: 3 Pages: 701-708
Publisher: Al-Nahrain University جامعة النهرين

Loading...
Loading...
Abstract

The objective of this paper is to develop an efficient P-wave detection algorithm based on the morphology characteristics of arrhythmias using time domain analysis. ECG from normal subjects, and patients with atrial fibrillation were studied. After baseline wander cancellation, power line interference filtration, the step of QRS detection using the pan- Tompkins algorithm is utilized to calculate R peak which represent the reference point to detect P peak. The algorithm was tested with experiments using MIT-BIH arrhythmia database which included Paroxysmal Atrial Fibrillation PAF prediction challenge, Massachusetts Institute of Technology MIT-BIH normal sinus rhythm, long term Atrial Fibrillation AF and MIT-BIH atrial fibrillation where every P-wave was extracted.The results reveal that the algorithm is accurate and efficient to detect and classify arrhythmias resulted from atrial fibrillation.

الهدف من هذه البحث هو تطوير كفاءة خوارزمية الكشف موجة- P استنادا إلى خصائص مورفولوجية عدم انتظام ضربات القلب باستخدام تحليل نطاق الزمن .وتضمنت التجارب العادية اشخاص طبيعين و و تشخاص يعانون من ارتجاف اذيني بعد معالجة الانحراف عن خط الاساس و الغاء او فلتره تاثير مصدر الطاقة . تم استخدام خوارزمية تومبكينزالمستخدمه للكشف عن موجة QRS لحساب قمة موجة R التي تمثل نقطة المرجع للكشف عن قمة الموجة P . تم اختبار الخوارزمية في التجارب باستخدام قاعدة بيانات عدم انتظام ضربات القلب لمعهد ماساتشوستس للتكنولوجيا والتي شملت نوبات الرجفان الأذيني المؤقت والايقاع الطبيعي للنبض و الارتجاف الاذيني المزمن و الارتجاف الاذيني حيث تم استخراج كل موجة P .. بينت النتائج أن خوارزمية دقيقة وفعالة لكشف وتصنيف عدم انتظام ضربات القلب الناتجة عن الرجفان الأذيني

Keywords

Atrial Fibrillation --- P-wave --- QRS --- ECG


Article
ECG Analysis Using DWT and Wavelet Coefficient to Reduce the Feature and SVM-ICP for Classification and Matching

Author: Janan A. Mahdi
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2018 Volume: 36 Issue: 8 Part (A) Engineering Pages: 925-929
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

The Electrocardiogram (ECG) considered as one of the important issue in the medical field (hospitals and clinics), which is used to represent the health of a heart. Increasing patients of heart has supposed to design an automatic computerization technique to classify various abnormalities of the heart activities; to reduce the analysis time and detection mistakes. This research focusing on achieve high performance of classifying abnormal ECG by applying different methods. The first method is Discrete Wavelet Transform (DWT) with 4-level to transform the ECG signal and extract the feature extraction and Wavelet Energy (WE) during feature extraction as feature vector. In classification phase has used Support Vector Machine (SVM) to train datasets and classify the test samples, in matching phase, find closest vector of test to the training datasets method has used by applying Iterative Closest Point (ICP).

Keywords

ECG --- DWT --- Wavelet Energy --- SVM --- ICP