Experimental and Numerical Investigation to Enhance the Performance of Helical Coiled Tube Heat Exchanger by Using Turbulators
دراسة عملية وعددية لتحسين أداء مبادل الحراري ذو أنبوب ملتف حلزوني باستخدام العوائق

Loading...
Loading...
Abstract

In the present work, numerical and experimental investigation is carried out to evaluate the performance of helical coiled tube heat exchanger with wire coil insert. Experimental work included design of wire coiled and inserted into a vertically positioned plain copper helical tube heat exchanger. The effects of wire coil insert with different parameters on heat transfer and friction loss in the helical tube were examined with Dean number ranging from 700 to 2000.The experiments of coiled wire were performed, firstly with three different pitches (P= 15, 20 and 30)mm with constant circular cross section(a=1mm), secondly with different cross section (circular and square) at constant pitch 15mm, and thirdly with two different square wire thickness (a =1, 2) mm at constant pitch 15mm. The numerical analysis was carried out to simulate the flow and heat transfer in a helical coil tube with wire coil insert at pitch (15mm) with different flow rates by using ANSYS FLUENT package 14.0. The experimental results showed that the use of tubular leads to a considerable increase in heat transfer and friction loss over those of a smooth coiled tube. The Nusselt number increases with the increasing of Dean number and the reduction in pitch for wire coils. The coiled square wire provides higher heat transfer than the circular one under the same conditions. A new empirical correlations have been developed to predict Nusselt number of the helical coil heat exchanger. Also the comparisons between numerical and experimental results show good agreement.

في البحث الحالي دراسة عددية وعملية لتقييم اداء مبادل حراري ذو انبوب حلزوني بداخله سلك حلزوني شبيهه بالنابض كأداة محسنة لانتقال الحرارة ومقارنة أداؤها في الأنابيب مع الأنابيب الملساء. شمل العمل التجريبي تصميم سلك ملفوف وضع داخل أنبوب حلزوني موضوع بشكل عمودي تم دراسة تأثير أبعاد مولد الدوامات على انتقال الحرارة ومعامل الاحتكاك ضمن رقم دين (700 -2000) .تم اجراء الاختبارات عند متغيرات عديدة للسلك الحلزوني(مولد الدوامات),اولا عند استخدام سلك ذو مقطع دائري بثلاثة ابعاد مختلفة من الخطوة (15و20و30 p=)ملم, ثانيا عند استخدام سلك بمقطعين (دائري ومربع)لخطوة ثابتة(p=15mm)وثالثا عند استخدام سلك ذو مفطع مربع بطول ضلع a=1,2mm))لخطوة ثابتة قدرها((p=15mm.تضمن الجانب العددي نمذجة لسلوك الجريان وانتقال الحرارة للمبادل الحراري باستخدام برنامج حاسوبيANSYS FLUENT 14))لتحديد تأثير السلك الحلزوني بخطوة ثابتة ((P=15mm أظهرت النتائج التجريبية أن استخدام مولدات الدوامة يؤدي إلى زيادة كبيرة في نقل الحرارة وفقدان الاحتكاك اكثر من تلك أنبوب الحلزوني الاملس . يزداد عدد نسلت مع زيادة عدد دين ونقصان الخطوة للسلك الحلزوني. لقد بينت المقارنة بين النتائج العملية والنظرية حصول تطابق جيد بينهما. طورت معادلة تجريبية لتوقع عدد ناسلت لأنبوب حلزوني مع إضافة السلك الحلزوني بالداخل.


Article
Finite Element Analysis of Fins with Convection and Radiation Heat Transfer
تحليل انتقال الحرارة من الزعانف بالحمل والإشعاع باستخدام طريقة العناصر المحددة

Author: Mohammed HamzaAbdulsada محمد حمزة عبد السادة
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2015 Volume: 8 Issue: 2 Pages: 242-258
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

One dimensional analysis of heat transfer from fin is simple when only heat transfer by convectionfrom fin surface. However, in some cases heat transfers by combined phenomena (convection andradiation), this makes the governing differential equation of heat transfer non-linear and the analyticalsolution becomes hard to solve. This paper uses an approximate method to solve the problem withhigh-quality results based on finite element technique. The method can be used for different types offins and for different shapes. The results show suitable agreement between semi-exact solution andnumerical solution

التحليل ببعد واحد لانتقال الحرارة للزعنفة بسيط عندما تنتقل الحرارة من الزعنفة بواسطة الحمل فقط ولكن عندما تنتقلالحرارة من الزعنفة بواسطة التأثير المشترك للحمل والإشعاع، المعادلة التفاضلية لانتقال الحرارة سوف تصبح غير خطيةوسوف يكون الحل التحليلي لها صعب.هذه الورقة استعملت طريقة تقريبية لحل هذه المشكلة مع ظهور نتائج جيدة. والتيهي تعتمد أساسا على تقنية العناصر المحددة. أن الطريقة المستخدمة يمكن أن تطبق على أنواع مختلفة وأشكال مختلفة منالزعانف. النتائج تشير الى توقف مناسيب بين الحل التحليلي والحل العددي


Article
Study the Effect of the Flow on the Performance of a shell and Tube Type Heat Exchanger Using Experimental Design Technique

Authors: Zuher Hassan Abdullah --- Saad Sami Farhan --- Thamer K. Salem
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2016 Volume: 23 Issue: 2 Pages: 38-45
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

In the current research an experimental study was done to show the effect of pulse flow on the effectiveness of shell and tube type heat exchanger. the study was in the case of steady and pulse flows with a changing mass flow rate of hot water flowing inside the pipes of the heat exchanger for the range between (0.0273-0.0819 kg / s) at fix mass flow rate of cold water that flows through the shell and on the outer surface of the pipes when (0.0416 kg / s), to obtain pulsing a used was solenoid valve. The research aims to measure the percentage effect of independent factors which were presenting the mass flow rate of hot water, flow type and the surrounding environment conditions of the experimental side upon shell and tube type heat exchanger performance using experimental design technique at the significant level (0.05).The results derived from the experimental tests showed that pulse flow leads to increase internal heat transfer coefficient (hi) comparing with its value in the steady flow and the highest increase was by (9.75%) at a mass flow rate of hot water (0.0416 kg / s) and increases the overall heat transfer coefficient (U), where the highest percentage was by )4.68%) at a mass flow rate of hot water (0.0416kg/s). The results also showed increasing both the number of transmitted units (NTU) and the effectiveness of the shell and tube type heat exchanger ( ) in the case of pulse flow of its value in the steady flow and the highest percentage of increase occurring was (4.75%) and (1.85%), respectively, and at the mass flow rate of hot water (0.0416 kg / s). Percentage effect of mass flow rate of hot water was (97%, 97.42%, 95.5%, 99.48%) and the percentage effect of each flow type and the errors were (2.8%, 2.25%, 2.44%, 0.4%) and (0. 2, 0.33%, 2.06%, 0.12) respectively.


Article
EXPERIMENTAL AND NUMERICAL STUDY OF ENHANCEMENT HEAT TRANSFER COEFFICIENT IN SPIRAL FLUTED TUBE HEAT EXCHANGER WITH NANOFLUID
دراسة عملية و عددية لتحسين أنتقال الحرارة في انبوب لولبي مخدد بوجود المائع النانوي

Authors: Muna S. Kassim --- Fouad A. Salah --- Ahmed O.Samarmad
Journal: Journal of Engineering and Sustainable Development مجلة الهندسة والتنمية المستدامة ISSN: 25200917 Year: 2015 Volume: 19 Issue: 6 Pages: 165-183
Publisher: Al-Mustansyriah University الجامعة المستنصرية

Loading...
Loading...
Abstract

Experimental and numerical investigation has been performed in this work to study enhancement of heat transfer coefficient in spiral fluted tube heat exchanger with Nanofluid. The shell side was made from galvanized tube of (65 mm) outer diameter. The tube was made from copper material of (1000 mm) length having (16 mm) equivalent inner diameter and (17 mm) outer diameter, it was inserted inside the shell. Steam was used, as a heating source where constant wall temperature condition (110˚C) was achieved, and TiO2 /water nanofluid with various volume concentrations (0.08%, 0.1%, 0.2%, and 0.3%) by volume at Reynolds numbers (7000 to 15000) has been employed, as working fluid flows through the inner tube. Fiber glass has been utilized to cover the outer surface of the shell for reducing heat losses. The performance of spiral fluted tube heat exchanger with and without nanofluid was investigated experimentally. Experimental results reveal that the use of spiral fluted tube without nanofluid leads to increase (28-33) % in heat transfer coefficient compared with smooth tube, and the maximum increase in heat transfer coefficient occurs when using spiral fluted tube with nanofluid at 0.3% volume concentration was about (25-28) % higher than the pure water in spiral fluted tube. Empirical correlations for water, nanofluid were represented by Nusselt number. Numerical simulation has been carried out on present heat exchanger to analyze both flow field and heat transfer using ANSYS 14, FLUENT package. The comparison between experimental and numerical results showed good agreement.

في هذا العمل تم انجاز دراسة عملية وعددية لتحسين انتقال الحرارة باستخدام انبوب لولبي مخدد بوجود المائع النانوي. القشرة مصنوعةمن الحديد المغلون 65 مليمتر قطر خارجي. الانبوب مصنوع من النحاس بطول 1000 مليمتر ، 16 مليمتر قطر داخلي مكافئ و 17 مليمتر قطرخارجي تم تثبيته داخل القشرة. استخدم البخار كمصدر حراري على السطح الخارجي للانبوب حيث تم الحصول على درجة حرارة ثابتة لسطحالانبوب ) °C110 (، المائع النانوي من نوع اوكسيد التيتانيوم /ماء مقطر بتراكيز حجمية مختلفة ) 0.08 ، 0.1 ، 0.2 ، 0.3 (% و يمر داخلالانبوب عند عدد رينولدز يتراوح بين ) 7000 - 15000 (. تم عزل القشرة من الخارج بعازل حراري لتقليل الحرارة المفقودة.تمت دراسة اداءالمبادل الحراري ذو الانبوب اللولبي المخدد بدون ومع المائع النانوي. بينت النتائج العملية زيادة في معامل انتقال الحرارة بمقدار) 28 - 33 (% عنداستخدام الانبوب اللولبي المخدد بدون المائع النانوي مقارنه بالانبوب الاملس،تم الحصول على اقصى زيادة في معامل انتقال الحرارة عند استخدامالانبوب اللولبي المخدد بوجود المائع النانوي وبتركيز 0.3 % بمقدار ) 25 - 28 (%مقارنه باستخدام الماء في الانبوب اللولبي المخدد.تم ايجادعلاقات تجريبية للماء و المائع النانوي بدلالة رقم نيسلت.تم انجاز محاكاة عددية للمبادل الحراري لتحليل جريان المائع و انتقال الحرارة باستخدامالبرنامج المختص .ANSYS 14, FLUENT package هناك تطابق مقبول عند المقارنة بين النتائج العملية والعددية


Article
Dynamics and Control of Heat Exchanger Networks
السلوك الديناميكي و السيطرة على شبكة المبادلات الحرارية

Authors: Duraid Fadhil Ahmed --- Cizan A. Ali
Journal: Engineering and Technology Journal مجلة الهندسة والتكنولوجيا ISSN: 16816900 24120758 Year: 2014 Volume: 32 Issue: 2 Part (A) Engineering Pages: 465-480
Publisher: University of Technology الجامعة التكنولوجية

Loading...
Loading...
Abstract

In this paper dynamics of plate heat exchanger networks is given by combining dynamic models of plate heat exchangers in the network. A mathematical model for plate heat exchanger is developed based on energy balance. Dynamic simulation of plate heat exchanger networks to different step changes in flow rate of both process fluid and utility fluid is conducted using MATLAB simulink. Plate heat exchanger networks has been controlled using split range control method with two manipulated variables which are process fluid and utility fluid. The simulation results showed that split range controller is the best action and gives better response compared with conventional controller.

تم في البحث الحصول على النموذج الديناميكي لشبكة المبادلات الحرارية الصفائحية من خلال الجمع بين النموذج الديناميكي لمبادلات الحرارية الصفائحية الموجودة في الشبكة. تم تطوير نموذج رياضي لمبادل الحراري الصفائحي بالاعتماد على موازنة الطاقة. أجريت محاكاة ديناميكية لشبكة المبادلات الحرارية الصفائحية باستخدام برنامج ماتلاب من خلال اجراء اضطراب درجي في معدل الجريان لمائعي العملية والخدمات. تمت السيطرة على شبكة المبادلات الحرارية الصفائحية باستخدام مسيطر المدى المنفصل ذو متغيرين للمعالجة و أظهرت نتائج المحاكاة بأن مسيطر المدى المنفصل هو أفضل أداء وأعطت استجابة جيدة مقارنة مع المسيطر التقليدي.


Article
OPEN CIRCUIT HEAT EXCHANGER DYNAMICS DURING FLOW REDUCTION TRANSIENT IN THEIR SECONDARY LOOPS

Author: Akram. W. Ezzat
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2011 Volume: 17 Issue: 6 Pages: 1502-1516
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An experimental and theoretical analysis was conducted for simulation of open circuit cross flow heat exchanger dynamics during flow reduction transient in their secondary loops. Finite difference mathematical model was prepared to cover the heat transfer mechanism between the hot water in the primary circuit and the cold water in the secondary circuit during transient course. This model takes under consideration the effect of water heat up in the secondary circuit due to step reduction of its flow on the physical and thermal properties linked to the parameters that are used for calculation of heat transfer coefficients on both sides of their tubes. Computer program was prepared for calculation purposes which cover all the variables that affect such type of transient mechanisms. The effect of the power density in the primary circuit and the water flow reduction percentage on the average temperature build up of the water in the primary circuit was investigated. The elapsed time required for the primary circuit average temperature to reach a steady state value was also calculated. These calculations were supported with experimental measurements conducted on a standard cross flow heat exchanger apparatus. The experimental results were compared with the theoretical results for certain power density value at different flow reduction percentages which show a reliable agreement. This relative agreement was necessary to consider the mathematical model with certain assurance for calculating transient parameters for higher power densities that are out of apparatus ranges. The results proved that water average temperature build up in the primary circuit has sharp tendency when the percentage of flow reduction in the secondary circuit reach 25% of its nominal values

تم أجراء تحليل عملي ونظري لمحاكاة ديناميكية المبادل الحراري من نوع الجريان المتقاطع أثناء الحالات غير المستقرة لنقصان جريان المبرد في دوراتها الثانوية. حيث تم أعداد موديل رياضي مبني على الفروقات المحددة لتغطية ميكانيكية عملية التبادل الحراري ما بين الماء الحار في الدورة الأساسية والماء البارد في الدورة الثانوية. أخذ الموديل بنظر الأعتبار تأثير زيادة تسخين الماء في الدورة الثانوية بسبب النقصان الدرجي لجريانه على الخصائص الفيزياوية والحرارية ذات العلاقة بالحدود المستخدمة في أحتساب معاملات التبادل الحراري على جانبي أنابيب المبادل الحراري. تم أعداد برنامج حسابي على الحاسوب الذي يغطي جميع العوامل المؤثرة لمثل هكذا نوع من ميكانيكية الحالات غير المستقرة. تم بحث تأثير كثافة الطاقة في الدورة الأساسية والنسبة المئوية لنقصان معدل جريان المبرد في الدورة الثانوية على زيادة معدل درجة حرارة الماء في الدورة الأساسية. تم كذلك حساب الزمن المستغرق لوصول معدل درجة حرارة الماء في الدورة الأساسية الى قيم مستقرة. هذه الحسابات تم تدعيمها بقياسات عملية تم اجرائها على جهلز مختبري لمبادل حراري من نوع الجريان المتقاطع. تم أجراء مقارنة بين الحسابات العملية والنظرية لكثافة طاقة معينة لنسب أنخفاض في معدلات جريان مختلفة وكانت نتائج المقارنة مقبولة. هذا التطابق النسبي كان ضروريا لأعتماد الموديل والبرنامج الرياضي في أحتساب النتائج لقيم كثافات طاقة أعلى من حدود تحمل الجهاز. النتائج برهنت أن زيادة معدل درجة حرارة الماء في الدورة الأساسية تأخذ ميلا حادا عند وصول قيم النسب المئوية لأنخفاض معدل الجريان الى 25% من قيمها الطبيعية.


Article
Experimental study of plate heat exchanger air cooler
دراسة تجريبية لمبادل حراري صفائحي كمبرد هواء

Author: احمد أديب عبد الواحد
Journal: Journal of Engineering مجلة الهندسة ISSN: 17264073 25203339 Year: 2010 Volume: 16 Issue: 4 Pages: 975- 988
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

As cooling air using water injection was limited by a range of humidity ratio so indirect humidification for air consider , this research take the study of heat transfer through a perpendicular plate heat exchanger to discover the influence optimum conditions on dehumidification efficiency and the amount of heat transfer energy across the plates of heat exchanger so calculating dehumidification efficiency and the amount of heat transfer energy across the plates of heat exchanger depending on the change of primary and secondary air flow rate using an experimental apparatus with an instruments for measuring air flow rate , dry bulb temperature and wet bulb temperature on air entry and exit sections , experimental procedure by fixing primary air mass flow rate with changing secondary air mass flow rate once and the condition of entering primary air another time , also fixing secondary air mass flow rate with primary air mass flow rate once and the condition of entering primary air another time . Results show that the increasing of both the dehumidification efficiency and the amount of heat transfer energy across the plates of heat exchanger depend on the increasing of secondary and decreasing of primary air flow rate , percentage of increasing dehumidification efficiency 16 when secondary air mass flow rate increase from 0 to 0.2 kg/s and percentage of increasing heat transfer 35 with above flow rate , percentage of decreasing dehumidification efficiency 12 when primary air mass flow rate increasing percentage 12 and percentage of increasing heat transfer 21 with above flow rate

لكون تبريد الهواء بإضافة الماء يكون محدداً بمدى معين من الرطوبة التي نستطيع إضافتها إليه والتي بدورها تعتمد على المحتوى الرطوبي للهواء لذلك يتم اللجوء إلى طريقة تبريد الهواء بالترطيب غير المباشر لذا يهدف البحث الحالي إلى دراسة موضوع انتقال الحرارة عبر أسطح مبادل حراري صفيحي متعامد الجريان ومعرفة الظروف المثلى المؤثرة على كفاءة الترطيب ومقدار الطاقة الحرارية المنتقلة عبر أسطح المبادل . تم حساب فعالية الترطيب ومقدار الطاقة الحرارية المنتقلة عبر أسطح المبادل ومدى تأثرهما بكل من تياري الهواء الرئيسي والثانوي حيث تم تثبيت كمية الهواء الثانوي مع تغيير كمية الهواء الرئيسي مرةً وتغيير ظروف الهواء الرئيسي الداخل عند معدل تدفق معين للهواء الرئيسي مرةً أخرى بعدها يتم تثبيت كمية الهواء الرئيسي مع تغيير كمية الهواء الثانوي مرةً وتغيير ظروف الهواء الرئيسي الداخل عند معدل تدفق معين للهواء الرئيسي مرةً أخرى , وللوصول إلى هذا الهدف تم استخدام جهاز مختبري تتوفر فيه إمكانية قياس معدلات تدفق الهواء ودرجات الحرارة للبصلتين الجافة والرطبة عند مقاطع الدخول والخروج لكلا التيارين الرئيسي والثانوي . وجد إن زيادة كلاً من فعالية الترطيب ومقدار الطاقة الحرارية المنتقلة عبر أسطح المبادل ترتبط بزيادة تدفق الهواء الثانوي ونقصان تدفق الهواء الرئيسي حيث تزداد فعالية الترطيب بنسبة 16% لتصل إلى 51%عند تغيير معدل تدفق الهواء الثانوي من صفر إلى 0.2kg/s وكذلك الحال بالنسبة لمقدار الطاقة الحرارية حيث تزداد بنسبة 35% لتصل إلى 1.15kW , كما إن فعالية الترطيب تقل بنسبة 12% عند زيادة معدل تدفق الهواء الرئيسي بنسبة 12% وكذلك الحال بالنسبة لمقدار الطاقة الحرارية حيث تقل بنسبة 21% لنفس نسبة النقصان في معدل التدفق أعلاه .


Article
AN EXPERIMENTAL STUDY ON A VAPOR COMPRESSION REFRIGERATION CYCLE BY ADDING INTERNAL HEAT EXCHANGER
دراسة عملية لدورة التثليج الأنضغاطية بإضافة مبادل حراري داخلي

Author: Muhammad Asmail Eleiwi
Journal: Tikrit Journal of Engineering Sciences مجلة تكريت للعلوم الهندسية ISSN: 1813162X 23127589 Year: 2008 Volume: 15 Issue: 4 Pages: 63-78
Publisher: Tikrit University جامعة تكريت

Loading...
Loading...
Abstract

This paper presents practical study to improve the indication COP of a vapor compression refrigeration cycle in instrumented automobile air conditioner by designing internal heat exchanger and installing it in the vapor compression refrigeration cycle. Two cases of vapor compression refrigeration cycle were taken in this paper: the first case is that the vapor compression refrigeration cycle without internal heat exchanger and in the second case the vapor compression refrigeration cycle with heat exchanger ; in these two cases, the temperature at each point of a vapor compression refrigeration cycle, the low and the high pressure ,the indoor temperature and the outdoor temperature were measured at each time at compressor speed 1450 rpm and 2900 rpm for each blower speed 1, blower speed 2 and blower speed 3.The refrigerant fluid was used in the vapor compression refrigeration cycle without IHE and with IHE is R134a..

أن هذا ا البحث يقدم دراسة عملية لتحسين معامل أداء منظومة التثليج الأنضغاطبة لجهاز تكيف سيارة بتصميم مبادل حراري داخلي وتنصيبة في دورة التثليج ألأنضغاطية.حالتان تم ألأخذ بها في دورة التثليج ألأنضغاطية, الحالة ألأولى هي دورة التثليج ألأنضغاطية بدون إضافة مبادل حراري والحالة الثانية هي دورة التثليج الأنضغاطية بإضافة مبادل حراري داخلي ; في تلك الحالتين سيتم قياس درجة الحرارة عند كل نقطة من دورة التثليج ألأنضغاطية وفي كل وقت ,الضغط العالي والضغط الواطئ سيتم قياسهم عند كل وقت, درجة الحرارة داخل الغرفة ودرجة الحرارة خارج الغرفة سيتم قياسهم عند كتل وقت أيضا عند سرعة 1450rpm و2900rpm للكومبريسر لسرعة بلور 1 , سرعة بلور 2 وسرعة بلور 3.مائع التبريد المستخدم في دورة التثليج ألأنضغاطية بدون المبادل الحراري الداخلي ومع المبادل الحراري الداخلي هو R134a.


Article
Numerical Study of the Unsteady State Cross Flow Heat Exchanger with Variable Fluid Parameters
نموذج رياضي لمبادّلِ حراري متقاطع الجريان غير مستقر مع مائع ذو خصائص متغيره

Loading...
Loading...
Abstract

ABSTRACTA numerical model for the unsteady state cross flow heat exchanger withvariable fluid parameters is presented. The model contains many sophisticatedassumptions that always avoided in the traditional analyzing of cross flow heatexchanger like variation of fluid properties (density, viscosity, thermal conductivityand convection heat transfer coefficient) and three dimensions unsteady state. Thehydrodynamic properties for both fluids are taken as fluid temperatures dependence.The heat transfer from the hot fluid to the surrounding cold fluids, and the heatexchanged between the cold fluid and the surrounding hot fluids channels andsurrounding cold fluids ducts are taken in account. The air is used as cold fluid, whilethe water as hot fluid. A numerical analysis by using Finite difference method is usedto solve the governing equations for both hot and cold fluids. The results shows that atsmall values of dimensionless X-xis (X = ΔX - 3ΔX) (ΔX = 0.021625), the hot fluidtemperature decreases at a constant value of dimensionless Y-Axis (height). The hotand cold fluid temperature lines are curved and lower values of the temperature in theleft side (X = ΔX - 3ΔX) and higher values of the temperature in the right side (X =5ΔX - 8ΔX). The hot and cold overall effectiveness of the system increase withincrease number of the cold duct per pass (ncp).

الخلاصةالنموذج العددي لانتقال الحرارة الغير مستقر داخل مبادّلِ حراري متقاطع الجريان ذو خصائصمتغيره تم وضعه. ھذا النموذج يحتوي على العديد مِنْ الفرضياتِ المعقده التي يتم إھمالھا عادتا في التَحليلالتقليديِ للمبادّلِ الحراري متقاطع الجريان مثل تغير الخصائص للسائلين (الكثافة، الزوجة، التوصيل حراريومعامل التوصيل الحراري) وكذلك ألحاله الغير مستقرة للمائع ثلاثي الأبعاد. تم الأخذ بنظر الاعتبار بانالخصائص الھيدروديناميكية للمائعين تتغير مع درجه حرارة المائع. عملية انتقال الحرارة من السوائل الساخنةإلى السوائل الباردة المحيطة بھا ، والحرارة المتبادلة بين السوائل الباردة والساخنة ا مع قنوات السوائل الباردةلمحيطة بھا تم أخذھا بنظر الاعتبار. يستخدم الھواء كسائل باردة ، في حين المياه كسائل ساخنة. طريقةِ الفروقاتاستعملت لحل معادلات السيطره لكلا من السائل الحار والبارد. النتائج (Finite Difference) المحدودةِفان ،(ΔX = 0.021625) (X = ΔX - 3ΔX) (X) أوضحت بأنه عند قيم صغيرة من القيمة اللابعدية لمحورخطوط درجات الحرارة .(Y) درجة الحرارة للسائل الساخن تنخفض عند قيم ثابتة من القيمة اللابعدية لمحور(X = ΔX - للسائل الساخن والبارد تكون منحنيه وتكون قيم درجات الحرارة المنخفضة في الجانب الأيسرالفاعلية الكليه للمائع الساخن . (X= 5ΔX - 8ΔX) 3 وقيم درجات الحرارة ألمرتفعه في الجانب الأيمن ΔX).( Ncp ) والبارد تزداد بزيادة عدد القنوات للمائع البارد


Article
Experimental Investigation of Using Evaporative Air Cooler for Winter Air-Conditioning in Baghdad
دراسة عملية باستخدام مبردة الهواء التبخيرية لغرض تكييف الهواء شتاءاً في بغداد

Authors: Zainab Hasson Hassan زينب حسون حسن --- Zainab Hassan Hanash زينب حسن حنش
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2012 Volume: 8 Issue: 4 Pages: 62-73
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

This paper presents an efficient methodology to design modified evaporative air-cooler for winter air-conditioning in Baghdad city as well as using it for summer air-conditioning by adding a heating process after the humidification process. Laboratory tests were performed on a direct evaporative cooler (DEC) followed by passing the air on hot water through heat exchanger placed in the coolers air duct exit. The tests were conducted on the 2nd of December /2011 when the ambient temperature was 8.1°C and the relative humidity was (68%). The air flow rate is assumed to vary between 0.069 to 0.209 kg/s with constant water flow rate of 0.03 kg/s in the heat exchanger. The performance is reported in terms of effectiveness of DEC, saturation efficiency of DEC, outlet temperature of air and cooling capacity. Heat transfer rate in heat exchanger mode is also estimated. The paper presents the mathematical development of the equations of thermal exchanges through DEC and HE. Prediction of air condition that exits o this system show that the present system could bring the air stream to a comfortable winter zone .

هذا البحث يقدّم نموذج بسيط وفعّال لتطوير مبردة هواء لغرض استخدامها للتدفئة في فصل الشتاء وبما يلائم المناخ في مدينة بغداد، ويتم ذلك بإضافة عملية تسخين بعد عملية الترطيب. تم تصميم وبناء منظومة لهذا الغرض واخذ القراءات المختبرية، حيث تتكون هذه المنظومة من مبردة هواء مرتبطة بمجرى للهواء مثّبت في نهايته مبادل حراري. تم أجراء التجارب في الثاني من شهر كانون الثاني لسنة 2011 حيث كانت درجة حرارة الهواء 8.1°C والرطوبة النسبية 68% ومعدل تدفق الهواء الداخل للمنظومة تتغير بين 0.069 to 0.209 kg/s مع ثبوت تدفق الماء للمبادل الحراري0.03 kg/s . تم الحصول على النتائج على هيئة فعالية مبردة الهواء، كفاءة مبردة الهواء، درجة حرارة الهواء الخارج من المنظومة وسعة التبريد وكذلك تم حساب انتقال الحرارة خلال المبادل الحراري . ان هذا البحث يقدم نموذج رياضي لمعادلات التبادل الحراري خلال مبردة الهواء والمبادل الحراري. على ضوء النتائج التي تم الحصول لظروف الهواء عند خروجه من المنظومة، فقد أثبتت هذه المنظومة فعاليتها وكفاءتها حيث تم الحصول على ظروف مريحة للهواء لفصل الشتاء.

Listing 11 - 20 of 79 << page
of 8
>>
Sort by
Narrow your search

Resource type

article (79)


Language

English (65)

Arabic and English (10)

Arabic (4)


Year
From To Submit

2019 (5)

2018 (11)

2017 (8)

2016 (9)

2015 (8)

More...