research centers


Search results: Found 54

Listing 11 - 20 of 54 << page
of 6
>>
Sort by

Article
New Mode for the On-Line Determination of Amiloride in Pure and Pharmaceutical Preparation Using CFIA Via the Use of Linear Array from Six LED (Snow White) with One Solar Cell in a Homemade Ayah 6Sx1-T-1D Solar CFI Analyser
نمط جديد للتقدير الاني للاميلورايد في المستحضرات الصيدلانية والنقية باستخدام التحليل بالحقن الجرياني المستمر عن طريق مصفوفة خطية لـ ست ثنائي وصلة باعث للضوء الابيض الثلجي مع خلية شمسية في محلل لقياس التعكرية Ayah 6Sx1-T-1D solar CFI

Author: Issam M.A. Shakir عصام محمد علي شاكر
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2014 Volume: 55 Issue: 4B Pages: 1708-1720
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A newly flow injection-turbidimetric method characterized by it is speed and sensitivity has been developed for the determination of Amiloride in pure and pharmaceutical preparations. It is based on the formation of yellowish white precipitate for the Amiloride-phosphomolybidic acid ion pair in aqueous medium. Turbidity was measured by Ayah 6Sx1-T-1D solar cell CFI analyser via the attenuation of incident light from the surfaces precipitated particles at 0-180. The Chemical and physical parameters were investigated. Linear dynamic range for the attenuation of incident light versus Amiloride concentration was of 0.005-10 mmol.L-1, with the correlation coefficient (r) of 0.9986 , while the percentage linearity (r2%) was 99.71%. The L.O.Q was of 23.14 µg/sample, while L.O.D (S/N=3) =5.74 ng/sample from the stepwise dilution for the minimum concentration in the calibration graph. The R.S.D% at 3, 9 mmol.L-1 Amiloride is less than 0.5% (eight replicates) using 50 µL sample volume. Through put was of 40 sample.hr-1. The method was applied successfully for the determination of Amiloride in pharmaceutical preparations. A comparison was made using the standard additions method via the use paired t-test. It showed that there was no significant difference between the quoted value of each individual paired t-test with calculated t-value at 95% confidence interval from developed method. In addition to comparison between two methods and calculate t-value, it was noticed that there was no significant difference between the two methods at =0.05 (95% confidence level).

طورت طريقة جديدة بالحقن الجرياني لقياس التعكرية وتميزت بالسرعة والحساسية لتقدير الاميلورايد في المستحضرات الصيدلانية والنقية. استندت على تكوين راسب ابيض مصفر للمزدوج الايوني: اميلورايد-حامض موليبدات الفسفوريك في الوسط المائي. تم قياس التعكرية بوساطة محلل الحقن الجرياني المستمرAyah 6Sx1-T-1D solar cell-CFI analyser عن طريق توهين الضوء المسلط من على سطوح دقائق الراسب بزاوية 0-180. تم دراسة الظروف الفضلى من المتغيرات الفيزيائية والكيميائية. المدى الخطي الفعال لعلاقة توهين الضوء الساقط ضد تركيز الاميلورايد 0.005-10 مللي مول.لتر-1 مع معامل ارتباط (r): 0.9986 ونسبة الخطية (r2%)=99.71%. معامل التقدير الكمي (L.O.Q) : 23.14 مكغم/انموذج بينما حد الكشف (S/N=3) L.O.D 5.74 نانوغرام/انموذج من التخفيف التدريجي لاقل تركيز في منحني المعايرة. الانحرافالقياسي النسبي المئوي لتركيز 3 و9 مللي مول.لتر-1 من الاميلورايد اقل من 0.5% (تكرارية لثمان مرات) باستخدام حجم لانموذج محقن 50 مايكرولتر. معدل النمذجة 40 انموذج/ساعة. طبقت الطريقة بنجاح لتقدير الاميلورايد في المستحضرات الصيدلانية. اجريت مقارنة باستخدام منحني الاضافات القياسية و اختبار-t المزدوج ولوحظ عدم وجود فرق جوهري بين القيمة الرسمية للاختبارات الانفرادية وقيمة t-المحسوبة عند فاصل ثقة 95% للطريقة المطورة بالاضافة الى اجراء مقارنة بين الطريقتين ولوحظ عدم وجود فرق جوهري بينها عند =0.05 (مستوى الثقة 95%).


Article
Determination of hydrogen peroxide in some local pharmaceutical disinfectants by continuous flow injection analysis via turbidimetric (T180o) and scattered light effect at two opposite positions (2N90o ) using Ayah 4SW-3D-T180o -2N90o -Solar - CFI Analyser
تقدير بيروكسيد الهيدروجين في بعض المطهرات الصيدلانية باستخدام تحليل الحقن الجرياني المستمر عن طريق قياس التعكريه (T180° ) وتأثير استطاره الضوء عند اتجاهين متعاكسين (2N90° ) باستخدام المحلل Ayah 4SW-3D-T180o -2N90o -Solar - CFI

Authors: Nagam S. Turkey Al-Awadie نغم شاكر تركي العوادي --- Ahmed F. Khudhair أحمد فاضل خضير
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 1C Pages: 577-592
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

An indirectly method is used to determine hydrogen peroxide. The method based on oxidation of chromium (III) ion by hydrogen peroxide in basic medium to form chromate ion which react with barium (II) ion to produce a yellow precipitate (BaCrO4). Under the optimum established conditions, the linear range of 0.50-25.00 mmol L-1 along with correlation coefficient (r) of 0.9992, Limit of detection (LOD) 0.68 µg / 100 µL, precision expressed as relative standard deviation for six replication measurements at 5.0 mmol.L-1 H2O2 of less than 2% were obtained for hydrogen peroxide. The developed method was successfully applied for the estimation of H2O2 in three pharmaceuticals preparation of different companies using continuous flow injection or stop-flow injection technique.

تم التقدير غير المباشر لبيروكسيد الهيدروجين من خلال تكوين راسب أصفر من كرومات الباريوم الناتج من اكسدة آيون الكروم (III) بأستعمال بيروكسيد الهيدروجين في الوسط القاعدي لتكون آيون الكرومات الذي يتفاعل مع آيون الباريوم(II) اذ كان مدى الخطية لمحلول بيروكسيد الهيدروجين بين (0.50-25.00) مللي مول.لتر-1 مع معامل الارتباط (r) 0.9992 , تم الحصول على حد كشف (L.O.D) 0.68 مايكروغرام 100 مايكرولتر و الانحراف القياسي النسبي المئوي لتركيز 5.0 مللي مول.لتر-1 أقل من 2% (n = 6). طبقت الطريقة بنجاح لتقدير بيروكسيد الهيدروجين في ثلاث مستحضرات صيدلانيه( شركات مختلفه) باستخدام جريان مستمر او جريان توقف.


Article
Turbidimetric Determination of Metoclopramide Hydrochloride in Pharmaceutical Preparation via the Use of A new Homemade Ayah 6SX1-T-2D Solar Cell-Continuous Flow Injection Analyser
التقديرالتعكري لميتاكلوبراميد هايدروكلوريد في المستحضرات الصيدلانية من خلال استخدام محلل جديد مصنع محليا للحقن الجرياني المستمر Ayah 6SX1-T-2D Solar cell

Authors: Nagam S. Turkie Al-Awadie نغم شاكر تركي العوادي --- Kefah H. Ismael Al-saadi كفاح حسن اسماعيل الساعدي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2015 Volume: 56 Issue: 2B Pages: 1224-1240
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A newly developed analytical method characterized by its speed and sensitivity for the determination of metoclopramide hydrochloride (MCP-HCl) in pure and pharmaceutical preparation via turbidimetric measurement (0-180o) by Ayah 6SX1-T-2D Solar cell-CFI Analyser. The method was based on the reaction of phosphomolybdic acid with metoclopramide hydrochloride in acidic medium to form yellowish white precipitate for the ion-pair complex. Turbidity was measured via the reflection of incident light that collides on the surface precipitated particles at 0-180o. Chemical and physical parameters were studied and optimized. The calibration graph was linear in the range of 0.0005-3 or 0.0005- 4 mMol.L-1, with correlation coefficient r = 0.9947&0.9845 respectively. The limit of detection 3.543 ng/sample from the step wise dilution for the minimum concentration in the linear dynamic ranged of the calibration graph with RSD% lower than 0.3% for 1, 3 mMol.L-1 (n=8) concentration of metoclopramide hydrochloride . The method was successfully applied to the determination of metoclopramide hydrochloride in three pharmaceutical drugs. A comparison was made between the newly developed method analysis with the classical method (HANNA instrument for turbidity measurement) using the standard addition method via the use of t-test. It was noticed that there was no significant difference between two methods at 95 % confidence level.

طورت طريقة تحليلية جديدة ,تميزت بالسرعة والحساسية لتقدير الميتاكلوبراميد هيدروكلورايد بشكلة النقي او على هيئة مستحضرات صيدلانية عن طريق قياس التعكرية 0-180º بوساطة محلل الحقن الجرياني المستمرAyah 6SX1-T-2D Solar cell .استندت الطريقة على تكوين راسب ابيض مصفر لمزدوج ايوني بين الميتاكلوبراميد هيدروكلورايد وحامض مولبدات الفسفوريك في الوسط الحامضي . تم قياس التعكرية عن طريق انعكاس الضوء المسلط والمصطدم بسطوح دقائق الراسب بزاوية 0-180º. تم دراسة كافة المتغيرات الكيميائية والفيزيائية . مدى الخطية لمنحني المعايرة للميتاكلوبراميد هيدروكلورايد تمتد 0.0005 - 3 أو 0.0005 - 4 مللي مول. لتر-1 بمعامل ارتباط =0.9947 و 0.9845 على التوالي .حدود الكشف 3.543 نانوغرام /نموذج من التخفيف التدريجي لأقل تركيز في منحني المعايرة مع انحراف قيايس نسبي مئوي اقل من 0.3% لتركيز1,3 مللي مول .لتر -1 (n=8) من الميتاكلوبراميد هيدروكلورايد . طبقت الطريقة بنجاح لتعيين الميتاكلوبراميدهيدروكلورايد في ثلاثة مستحضرات صيدلانية . اجريت المقارنة بين الطريقة المستحدثة للتحليل والطريقة التقليدية لقياس التعكرية باستخدام الاضافات القياسية بوساطة اختبار t المزدوج ولوحظ انه لايوجد فرق جوهري بين الطريقتين عند مستوى قناعة 95 %.


Article
Determination of Mefenamic Acid Using a New Mode of Irradiation (Array of Six Identical LEDs) and Detection( Twin Solar Cells) Through Turbidity Measurement by CFIA
تقدير حامض الميفيناميك باستخدام نمط جديد من التشعيع (مصفوفة متشابهة لستة ثنائيات وصلة باعثة) والتحسس ( اثنان من الخلايا الشمسية) خلال قياس التعكرية بوساطة التحليل بالحقن الجرياني المستمر

Authors: Nagam S. Turkie Al-Awadie نغم شاكر تركي العوادي --- Mustafa K. Kadhim Al-Saeedi مصطفى كريم كاظم السعيدي
Journal: Iraqi Journal of Science المجلة العراقية للعلوم ISSN: 00672904/23121637 Year: 2016 Volume: 57 Issue: 2B Pages: 1052-1070
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

A newly developed analytical method characterized by its speed and sensitivity for the determination of mefenamic acid (MFA) in pure and pharmaceutical preparation is established via turbidimetric measurement (0-180o) by Ayah 6SX1-ST-2D Solar cell CFI Analyser . The method was based on the reaction of phosphomolybdic acid with mefenamic acid in aqueous medium to form blue color precipitate as an ion-pair complex . Turbidity was measured via the reflection of incident light that collides on the surface precipitated particles at 0-180o . The chemical and physical parameters were studied and optimized. The calibration graph was linear in the range of 0.3-7 or 0.3-10 mMol.L-1, with correlation coefficient r = 0.9907 or 0.9556 respectively. The limit of detection 4.92 µg/sample from the step wise dilution for the minimum concentration in the linear dynamic ranged of the calibration graph with RSD% lower than 0.3% for 3 and 5 mMol.L-1 ( n= 6,10 respectively ) concentration of mefenamic acid. The method was successfully applied to the determination of mefenamic acid in four pharmaceuticals . A comparison was made between the newly developed method analysis and the classical method , in addition to between four different pharmaceutical preparations (UV- spectrophotometry at wave length 288 nm) using the standard additions method via the use of t-test. It was noticed that there was no significant difference between two methods at 95 % confidence level and significant difference between four drugs.

طورت طريقة تحليلية جديدة ,تميزت بالسرعة والحساسية لتقدير حامض الميفيناميك بشكله النقي او على هيئة مستحضرات صيدلانية عن طريق قياس التعكرية (0-180º) بواسطة محلل الحقن الجرياني المستمر 6SX1-ST-2D Solar cell Ayah. استندت الطريقة على تكوين راسب ازرق اللون لمزدوج ايوني بين حامض الميفيناميك وحامض مولبدات الفسفوريك في الوسط المائي. تم قياس التعكرية عن طريق انعكاس الضوء المسلط والمصطدم بسطوح دقائق الراسب بزاوية0-180º. تم دراسة كافة المتغيرات الكيميائية والفيزيائية. مدى الخطية لمنحني المعايرة لحامض الميفيناميك يمتد 0.3-7 أو 0.3-10 مللي مول.لتر-1 بمعامل ارتباط=0.9907 و0.9556 على التوالي. كان حد الكشف 4.92 مايكروغرام/انموذج من التخفيف التدريجي لأقل تركيز في منحني المعايرة مع انحراف قياسي نسبي معنوي اقل من 0.3% للتراكيز 3 و5 مللي مول.لتر-1 (n=10,6 على التوالي) من حامض الميفيناميك. طبقت الطريقة بنجاح لتعيين حامض الميفيناميك في اربعة مستحضرات صيدلانية. اجريت المقارنة بين الطريقة المستحدثة للتحليل والطريقه التقليديه للقياس الطيفي عند λmax=288 نانومتر بأستخدام منحني الأضافات القياسية بالاضافة الى المقارنه بين اربعة مستحضرات صيدلانية بوساطة اختبار t المزدوج ولوحظ انه لايوجد فرق جوهري بين الطريقتين عند مستوى قناعة 95 % مع فرق جوهري بين المستحضرات الصيدلانيه الاربعة.


Article
Evaluating the Performance of Sharq Dijila Water Treatment Plant
تقيم اداء محطة ماء شرق دجلة

Authors: Wassel Kadum واصل كاظم --- Faris Hammoodi Al-Ani فارس حمودي محمد
Journal: Al-Khwarizmi Engineering Journal مجلة الخوارزمي الهندسية ISSN: 18181171 23120789 Year: 2011 Volume: 7 Issue: 2 Pages: 55-67
Publisher: Baghdad University جامعة بغداد

Loading...
Loading...
Abstract

The study aims mainly to evaluate the performance of Sharq Dijila water treatment plant in removing turbidity for the period of 1-4-2001 to 31-3-2004. Daily data for turbidity of raw, clarified, filtered, and supplied water were analyzed. The results of the study showed that there is a wide variation in turbidity levels of raw water fluctuating between 10-1000 NTU with mean value of 41.3 NTU. Turbidity values of the clarified water varied between 1.4-77 NTU. Based on the turbidity value of 10 NTU and 20 NTU (the design maximum turbidity) the readings gave an acceptable percentage of 32.4% and 86% respectively. The turbidity of filtered water ranged between 0.2-4.5 NTU which are completely in compliance with Iraqi and WHO standards. In accordance with the American Environmental Protection Agency (USEPA) and based on the analysis of 2-day moving average of 5 NTU and 30-day moving average of 1 NTU, it was found that the filters operated at acceptable percentage of 100% and 45% respectively. Turbidity value of the supplied water averaged between 0.4-9.5 NTU which is higher than the turbidity of the filtered water due to the mixing of the water from all other filters. Also turbidity values from the unwashed filters are higher than the washed filters and the precipitation in the treated water reservoir. Based on the Iraqi Drinking Water Standard, USEPA 2-day and 30-day moving average, the supplied water was within the permissible limits of 98%, 98.6%, and 98.6% respectively.

إن الهدف من هذه الدراسة هو تقيم اداء محطة تصفية ماء شرق دجلة في ازالة العكورة للفترة من 1-4-2001 ولغاية 31-4-2004 تم تحليل قياسات العكورة للمياه الخام، المياه المرسبة، المياه المرشحة، والمياه المجهزة. بينت نتائج الدراسة ان هناك اختلاف كبير في درجة العكورة للماء الخام تراوحت بين 1-1000 وبمعدل41,3 وحدة قياس العكورة . قيم العكورة للمياه المرسبة كانت 1.4-77 وحدة و بالاعتماد على قيمة عكورة 10 و20 (التصميمية) نرى ان القراءات اعطت نسبة قبول مقدارها 32.4% و86% على التوالي. اما العكورة للمياه المرشحة فتراوحت بين 0.2-4.5 وحدة والتي تتوافق كليا مع مواصفة القياسبة العراقية ومواصفة منظمة الصحة العالمية. وبالمقارنة مع مواصفة منظمة حماية البيئة الامريكية وبالاعتماد على تحليل 2- يوم معدل متغير (5 وحدة ) و30- يوم معدل متغير (1وحدة ) وجد ان الفلاتر تعمل بنسبة قبول قدرها 100%و45% على التوالي.واما المياه المجهزة تراوحت العكورة بين 0.4-9.5 وحدة وهي اعلى من عكورة المياه الراشحة وهذا نتيجة للخلط الحاصل بين مياه جميع المرشحات كون العكورة للمرشحات الغير مغسولة اكبر من المرشحات المغسولة اضافة للترسبات الطينية داخل الخزان الارضي للمياه المجهزة. وبالاعتماد على المواصفات القياسبة العراقية، 2- يوم معدل متحرك، و30- يوم معدل متحرك فأن المياه المجهزة كانت 98%، 98.6%، 98.6% ضمن الحدود المسموح بها على التوالي


Article
IRAQI WATER TREATMENT PLANTS PROCESS CONTROL BY MEASURING EFFLUENT TURBIDITY
السيطرة على وحدات معالجة مياة الشرب في العراق بقياس كمية العكورة الناتجة

Authors: Jwad Khadhum. Ghaziy م.م. جواد كاظم غازي --- Ali H. GHAWI1 د.علي هادي غاوي
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2010 Volume: 3 Issue: 4 Pages: 373-381
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

The Al-Dewanyia Water General Authority (DWGA) operates and maintains four water treatment plants to produce potable water for 300,000 inhabitations in Al-Dewanyia city. Surface water from Al-Dewanyia river is treated by aluminum sulphate (alum) coagulation, flocculation, sedimentation, filtration, and chlorine disinfection (clearwell). DWGA has set goals for turbidity for clarified and filtered water. These goals pertain to water inside the Water Treatment Plant (WTP), outside the water treatment plant, and in the distribution system, DWGA continues to meet the Iraqi Ministry of Health Standard of 5 NTU. Each day at DWGA WTPs, chemists measure the turbidity of water from each individual clarifier and from each individual filter. The WTP Manager reviews this data and uses it to make process control decisions about chemical dosage and filter backwash. This paper explains DWGA’s Turbidity Goal for filtered water, presents recent data, and describes how WTP managers use this data for process control. Any water treatment plant in Iraq can use these procedures. The results can be better process control and higher quality water

مديرية ماء الديوانية تشغل و تصين اربعة محطات لمعالجة مياه الشرب في مدينة الديوانية و التي تخدم 300,000 ألف نسمة. ان مصدر المياه المعالج هو نهر الديوانية و تستخدم وسائل التلبيد (إضافة الشب) و التخثير و الترسيب و الترشيح و التعقيم في تصفية المياه. مديرية ماء الديوانية و ضعت أهداف لإزالة العكورة من حوضي الترسيب و الترشيح. هذة الأهداف تتمثل بالحصول على ماء صالح للشرب و مطابق للمواصفات العراقية و البالغة NTU 5 . تم قياس تركيز العكورة يوميا من أحواض الترسيب و أحواض الترشيح. المهندسين المسئولين عن تشغيل المشروع قاموا بتحليل تلك القياسات لاتخاذ قرار حول مقدار الشب المضاف و عملية غسل الفلاتر. من خلال هذا البحث تم توضيح وسيلة فعالة من خلال القياسات اليومية لتركيز العكورة للحصول على ماء مطابق للمواصفات العراقية.ان هذة التقنية يمكن استخدامها في أي محطة معالجة لمياه الشرب في العراق.


Article
PERFORMANCE EVALUATION OF AL-DEWANYIA WATER TREATMENT PLANT IN IRAQ
تقيم أداء محطة معالجة مياه الشرب في مدينة الديوانية

Author: د . علي هادي غاوي,د. عباس عليوي الجبوري
Journal: Al-Qadisiyah Journal for Engineering Sciences مجلة القادسية للعلوم الهندسية ISSN: 19984456 Year: 2009 Volume: 2 Issue: 4 Pages: 664-677
Publisher: Al-Qadisiyah University جامعة القادسية

Loading...
Loading...
Abstract

In order to design and operate an effective water treatment system, a thorough understanding of the process of coagulation-flocculation and filtration is essential in the delivery of water of the greatest clarity and lowest possible turbidity in the finished water. This research outlines the finding of investigation of the treatment plant in Al-Dewanyia in Iraq. Performance of Al-Dewanyia Water Treatment Plant in Iraq is an essential parameter to be monitored and evaluated to better understanding of design and operating difficulties in water treatment plants. The conclusions of these evaluations may determine required recommendations and highlight modification requirements for continuous design and operating schemes. The evaluation conducted in this research was carried out by reviewing the engineering design to assure matching of standards and codes. Also, physical (turbidity and TSS) , and biological, analysis were conducted to investigate water quality. The conclusions drawn from this research outlines the importance of accurate engineering design and need for continuous monitoring and analysis of each unit performance. Finished water is not conforming to World Health Organization (WHO) Standard for Drinking water.

لتصميم و تشغيل محطات معالجة مياه الشرب بكفاءة عالية, يتطلب أدراك شامل لعمليات و مراحل معالجة مياه الشرب من تخثير, تلبيد و ترشيح لغرض أنتاج مياه صالحة للشرب و تقليل العكورة إلى أدنى حدود مسموحه. يلخص هذا البحث تقيم أداء محطة معالجة مياه الشرب في مدينة الديوانية في العراق. يعتبر تقييم أداء محطة معالجة مياه الشرب في مدينة الديوانية عامل ضروري و مهم لمراقبة و تقيم و فهم صعوبات التصميم و التشغيل لمحطات معالجة مياه الشرب في العراق لان معظم محطات المعالجة في العراق لها نفس التصميم الهيدروليكي ومصدر المياه هو النهر (مياه سطحية) و لكن تختلف في مقدار التدفق. في هذا البحث تم تقييم التصميم الهندسي لمحطة المعالجة لغرض التأكد من مطابقته للمحددات التصميمية. و لغرض تقييم نوعية الماء الناتج من المحطة تم قياس العكورة, المواد الصلبة العالقة, و الملوثات الحيوية في مختبر محطة المعالجة. و من أهم نتائج هذه الدراسة هو وجوب الاهتمام بتصميم محطات المعالجة و المراقبة المستمرة لمراحل المعالجة و تحليل أداء كل مرحلة. ان نوعية الماء الناتج ن محطة المعالجة لا يتوافق مع معاير ومحددات منظمة الصحة العالمية لمياه الشرب.


Article
Behavior Assessment Of Various Filters Configuration In Removing Water Low Turbidity: A Statistical Treatment
تقييم سلوكية مختلف أنواع المرشحات في إزالة العكورة الواطئة: معالجة إحصائية

Loading...
Loading...
Abstract

Abstract The research focuses on the behavior of laboratory bench-scale filters that receive low-turbidity raw water. The filters have different configuration in terms of materials type, materials size and thickness. These filters operate under in-line and direct mode of filtration with different doses of alum and coagulant aid. A total of 200 filter runs were conducted. Statistical methods had been used in the determination of best configurations of tried filters. Analysis of variance (ANOVA) and Duncan multiple range test had been employed for this purpose. The results showed the superiority of filters operating under direct filtration mode compared to those of in-line filtration mode. It was thought that flocculation played a role in this result. Fine sand media of 0.56 mm E.S appeared to surpass the coarse media due to more trapping of impurities at pore spaces. The effect of coagulant aid addition was detected to act positively only with capping media filters, where an improvement in performance did occur. However, such improvement was low and did not justify importation of anthracite coal and coagulant aids and add an economic burden. Keywords: Filtration modes, Filtration, Water turbidity, Water treatment.

الخلاصة يركز البحث حول أداء مجموعة من المرشحات المختبرية في معالجة مياه قليلة العكورة. هذه المرشحات ذات اوساط مختلفة المواد والاعماق والاحجام المؤثرة . تعمل المرشحات بطريقتي الترشيح بالمسار والترشيح المباشر وتتغذى بجرع متغايرة التركيز من الشب ومساعدات التخثير. جرى تحليل النتائج احصائيا باتباع طريقة تحليل التباين واختبار دنكن بقصد تحديد أفضل تركيبة من هذه المرشحات. وقد أظهرت النتائج تفوق المرشحات العاملة بطريقة الترشيح المباشر على نظيرتها العاملة بطريقة الترشيح بالمسار، ويعتقد ان لعملية التلبيد في الترشيح المباشر دورا مهما في هذا التفوق . كما وجد ان المرشحات المتكونة من أوساط من الرمل ذي الحجم المؤثر (0.56) ملم أظهرت كفاءة أفضل من مرشحات الرمل ذات الحجم المؤثر الأكبر وهذا يعود الى تاثير حجم الفراغات بين حبيبات الرمل في اقتناص المزيد من الشوائب. كما وجد ان استخدام مساعدات التخثير يفيد فقط في حالة استخدام مرشحات ثنائية الوسط إذ تتحسن أداء المرشحات في إزالة العكورة. وبنفس الوقت فان استخدام الأنثراسيت أو مساعدات التخثُير لا يبرر استيراد هاتين المادتين لان الفرق ضئيل في مدى التحسن الحاصل في كفاءة الازالة.


Article
The Effect Burnt Alum To Removing Turbidity From Water
تاثير حرق الشب على ازالة العكورة من الماء

Authors: Lilian Yaqup Matt ليليان يعقوب متي --- Soad Abid Abawi سعاد عبد عباوي
Journal: AL Rafdain Engineering Journal مجلة هندسة الرافدين ISSN: 18130526 Year: 2006 Volume: 14 Issue: 3 Pages: 43-52
Publisher: Mosul University جامعة الموصل

Loading...
Loading...
Abstract

AbstractThe research focuses on the use of ordinary and burnt alum to remove thelight turbidity (10 NTU) and reduces the medium ones (75NTU) by adding ofdifferent doses of ordinary alum Al2(SO4)3.16H2O and compare the results withthese obtained from the burned alum at varying temperatures (200, 300, 400, 500,600) C0.Jar test is used to find the change in the water characteristics of turbidity, pH, ECat the conditions. The study revealed that 10mg/l of burnt alum at 200Co and moregive, final turbidity of about (2NTU), while it gives NTU between (7-8) in thecase of using ordinal alum in removing of the light turbidity of (10NTU). In thecase of reduction of the medium turbidity it find that 10mg/l of burned alum at200Co reduces the final turbidity to about (3NTU).It appears also that the alum consumption is about 14% in case of using burntalum as compared with the ordinary alum especially in reducing of the mediumturbidity to 5NTU.key word (burnt alum, remove the light turbidity, Jar test)

حرقه في إزالة العكورة المنخفضة من الماء والتي هي اقل من75 ) وذلك باضافة جرع NTU) 10 ) وخفض العكورة المتوسطة في الماء والتي هي بحدود NTU)ومقارنتها مع نفس الجرع من هذا الشب بعد حرقه Al2 (SO4)3 .16H2O مختلفة من الشب العاديبدرجات حرارية مختلفة شملت ( 600، 500، 400، 300، 200 ) درجة مئوية ومتابعة التغيير في(Jar Test) والتوصيل الكهربائي من خلال أجراء فحص الجرة pH ، خصائص الماء ومنها الكدرةعلى العينات تحت نفس الظروف التشغيلية.وقد أظهرت نتائج البحث ان جرعة ( 10 ) ملغم/لتر من الشب المحروق بدرجة 200 مئوية فاكثر تعطي2) بينما تعطي نفس الجرعة من الشب العادي كدرة نهائية NTU) كدرة نهائية مقدارها بحدود10 ) . آما في حالة خفض الكدرة NTU ) 7-8 ) في حالة إزالة الكدرة المنخفضة )NTU بحدود75 ) فقد وجد ان جرعة 10 ملغم /لتر من الشب المحروق بدرجة 200 درجة مئوية NTU) المتوسطة.( 3 NTU) تخفض الكدرة الى حدودكما اثبت البحث ان هناك جدوى اقتصادية في كميات الشب المستهلكة تعادل (% 14 ) من حالة استخدام.( 5NTU) الشب المحروق بد ً لا من الشب العادي في خفض العكورة المتوسطة الى كدرة نهائية اقلالكلمات الدالة: (الشب المحروق، ازالة العكورة الواطئة،فحص الجرة


Article
Performance of Dual-Media Down-Flow Rapid Gravity Filters

Loading...
Loading...
Abstract

The present study was conducted to evaluate the effect of variation of influent raw water turbidity, bed composition, and filtration rate on the performance of mono (sand) and dual media (sand and anthracite) rapid gravity filters in response to the effluent filtered water turbidity and head loss development. In order to evaluate each filter performance, sieve analysis was made to characterize both media and to determine the effective size and uniformity coefficient. Effluent filtered water turbidity and the head loss development was recorded with time during each experiment.

Listing 11 - 20 of 54 << page
of 6
>>
Sort by
Narrow your search

Resource type

article (54)


Language

English (42)

Arabic (6)

Arabic and English (5)


Year
From To Submit

2018 (2)

2017 (2)

2016 (8)

2015 (6)

2014 (12)

More...